Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biomedical Engineering and Bioengineering (258)
- Biomedical Devices and Instrumentation (101)
- Biomechanics and Biotransport (86)
- Medicine and Health Sciences (85)
- Life Sciences (69)
-
- Electrical and Computer Engineering (64)
- Applied Mechanics (57)
- Computer-Aided Engineering and Design (57)
- Electro-Mechanical Systems (44)
- Materials Science and Engineering (44)
- Biomedical (43)
- Manufacturing (43)
- Physical Sciences and Mathematics (41)
- Other Biomedical Engineering and Bioengineering (37)
- Biomaterials (36)
- Biomechanics (33)
- Kinesiology (33)
- Other Mechanical Engineering (29)
- Engineering Science and Materials (26)
- Acoustics, Dynamics, and Controls (25)
- Computer Engineering (22)
- Molecular, Cellular, and Tissue Engineering (22)
- Computer Sciences (21)
- Biology and Biomimetic Materials (20)
- Medical Specialties (20)
- Polymer and Organic Materials (20)
- Rehabilitation and Therapy (20)
- Institution
-
- California Polytechnic State University, San Luis Obispo (103)
- Cleveland State University (76)
- University of Denver (41)
- University of Nevada, Las Vegas (31)
- Old Dominion University (30)
-
- University of Central Florida (27)
- University of Kentucky (26)
- University of Nebraska - Lincoln (26)
- Virginia Commonwealth University (20)
- Purdue University (17)
- University of Arkansas, Fayetteville (16)
- Michigan Technological University (15)
- Embry-Riddle Aeronautical University (12)
- The University of Akron (12)
- Boise State University (11)
- Clemson University (11)
- Technological University Dublin (11)
- Georgia Southern University (10)
- Louisiana State University (10)
- Department of Primary Industries and Regional Development, Western Australia (9)
- Portland State University (9)
- Southern Methodist University (9)
- Washington University in St. Louis (9)
- University of Louisville (8)
- Bucknell University (7)
- Marquette University (7)
- University of North Florida (7)
- City University of New York (CUNY) (6)
- West Virginia University (6)
- American University in Cairo (5)
- Keyword
-
- Biomechanics (53)
- Daniel Felix Ritchie School of Engineering and Computer Science (37)
- Mechanical and Materials Engineering (30)
- Prosthetic (17)
- Gait (15)
-
- Knee (14)
- Rehabilitation (14)
- Finite Element Modeling (13)
- Robotics (13)
- Kinematics (12)
- Engineering (11)
- Simulation (11)
- Design (10)
- Mechanical Engineering (10)
- CFD (9)
- Finite element analysis (9)
- 3D Printing (8)
- 3D printing (8)
- Electromyography (8)
- FEA (8)
- Musculoskeletal modeling (8)
- Optimal control (8)
- Optimization (8)
- Prosthesis (8)
- Finite Element Analysis (7)
- Osteoarthritis (7)
- Piezoelectric (7)
- Viscoelasticity (7)
- Wheelchair (7)
- Academic -- UNF -- Master of Science in Mechanical Engineering; Dissertations (6)
- Publication Year
- Publication
-
- Mechanical Engineering Faculty Publications (71)
- Mechanical Engineering (60)
- Electronic Theses and Dissertations (53)
- Master's Theses (34)
- Theses and Dissertations (26)
-
- UNLV Theses, Dissertations, Professional Papers, and Capstones (26)
- Mechanical & Aerospace Engineering Theses & Dissertations (20)
- Theses and Dissertations--Mechanical and Aerospace Engineering (20)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (17)
- Dissertations, Master's Theses and Master's Reports (12)
- Electronic Theses and Dissertations, 2020-2023 (12)
- Williams Honors College, Honors Research Projects (12)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (11)
- Dissertations and Theses (10)
- Doctoral Dissertations and Master's Theses (10)
- Honors Undergraduate Theses (10)
- Biomedical Engineering (8)
- Boise State University Theses and Dissertations (8)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (8)
- Mechanical Engineering Research Theses and Dissertations (8)
- College of Graduate Studies: Theses & Dissertations (7)
- Conference Papers (7)
- Graduate Theses and Dissertations (7)
- Journal of the Department of Agriculture, Western Australia, Series 4 (7)
- Mechanical & Aerospace Engineering Faculty Publications (7)
- UNF Graduate Theses and Dissertations (7)
- All Dissertations (6)
- Dissertations (6)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (6)
- LSU Doctoral Dissertations (6)
- Publication Type
- File Type
Articles 451 - 480 of 697
Full-Text Articles in Biomechanical Engineering
The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin
The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin
UNLV Theses, Dissertations, Professional Papers, and Capstones
Many studies have demonstrated clinical applications for the use of dental pulp stem cells (DPSC) for the treatment of various conditions. This has driven medical and scientific interest in the collection, isolation and banking of DPSC tissues for research into these potential therapies. Few studies to date have evaluated the viability of DPSC following long-term cryopreservation. The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and …
Flex-Ro: Design, Implementation, And Control Of Subassemblies For An Agricultural Robotic Platform, Jared Patrick Werner
Flex-Ro: Design, Implementation, And Control Of Subassemblies For An Agricultural Robotic Platform, Jared Patrick Werner
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Automation technology in agriculture is growing, making agricultural robotics viable. Innovative field usable multi-purpose robotic platforms are needed for the successful progression of agricultural robotics. Furthermore, the field of agricultural robotics would benefit from a robotic platform design allowing for variable height, thus accommodating navigation throughout various crop growth stages. A variable height machine, Flex-Ro was developed to accommodate this feature. Multiple sub-assemblies were designed and implemented for Flex-Ro. An electronic control unit (ECU) enabled engine was used to power Flex-Ro. An embedded application program was developed to control engine speed using proprietary Controller Area Network (CAN) messages in conjunction …
Fluid Dynamic Factors As A Cause And Effect Of Biofilm Formation Of Staphylococcus Aureus Biofilms, Erica Sherman
Fluid Dynamic Factors As A Cause And Effect Of Biofilm Formation Of Staphylococcus Aureus Biofilms, Erica Sherman
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Staphylococcus aureus bacteria are able to form biofilms and distinctive tower structures that facilitate their ability to tolerate treatment and to spread within the human body. The formation of towers, which break off, get carried downstream and serve to initiate biofilms in other parts of the body are of particular interest here. It is known that flow conditions play a role in the development, dispersion and propagation of biofilms. The influence of flow on tower formation and what factors lead to tower formation is not at all understood The hypothesis being examined is that tower structures form within a specific …
Development And Implementation Of High Fidelity Human Models For The Investigation Of Blast And Non-Penetrating Projectile Impact, Candice F. Cooper
Development And Implementation Of High Fidelity Human Models For The Investigation Of Blast And Non-Penetrating Projectile Impact, Candice F. Cooper
Mechanical Engineering ETDs
Military operations abroad have highlighted the effects of several types of physical traumas including traumatic brain injury and behind armor blunt trauma. While previous approaches toward understanding and mitigating trauma caused by blast or blunt impact relied upon physical testing of animal subjects, post mortem human subjects, or human tissue surrogates, recent advances in computational capability have spurred a growing area of research in computational investigations into wound injury and its mitigation. The development of high-fidelity human torso and head-neck-torso models are presented here. These models are employed in blast and non-penetrating projectile impact simulations in order to demonstrate the …
Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee
Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee
The Summer Undergraduate Research Fellowship (SURF) Symposium
Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …
Movement And Distribution Of Bacteria Near Surfaces, Daniel A. Quinkert, Adib Ahmadzadegan, Arezoo M. Ardekani
Movement And Distribution Of Bacteria Near Surfaces, Daniel A. Quinkert, Adib Ahmadzadegan, Arezoo M. Ardekani
The Summer Undergraduate Research Fellowship (SURF) Symposium
Bacteria are found everywhere in nature, including within human/animal bodies, biomedical devices, industrial equipment, oceans and lakes. They can be found in planktonic state within a bulk liquid phase or attached to surfaces with the potential to form biofilms. In this study we are interested in the movement and distribution of bacteria near surfaces. The concentrations and fluid interactions of bacteria were characterized at various distances from a surface. Psuedomonas putida F1 was observed in a suspension near a surface. Bacteria movements were visualized with an inverted microscope at 40x magnification. P. putida F1 exhibited greater density in close proximity …
Microfluidic Platform For Impedance Characterization Of Endothelial Cells Under Fluid Shear Stress., Vanessa Velasco
Microfluidic Platform For Impedance Characterization Of Endothelial Cells Under Fluid Shear Stress., Vanessa Velasco
Electronic Theses and Dissertations
Endothelium dysfunction has been associated with many pathophysiological processes leading to cardiovascular diseases. Studying endothelium behavior is vital to understand the onset, prevention, and treatment of such diseases. Electrical impedance spectroscopy has been shown to provide a real-time in vitro evaluation of cell behavior including cell monolayer permeability. However, the majority of published work has been primarily with static cell culture models or macro-scale models that do not properly represent the physiological sizes, structures, and environmental conditions of human blood vessels. Within this dissertation, the design, fabrication, characterization, and application of a microfluidic impedance platform is presented for the in …
Strain Energy Absorption Corresponds To Decreased Incidence Of Ventricular Fibrillation In A Commotio Cordis Model, Kayt E. Frisch, Mark S. Link, John Van Weelden
Strain Energy Absorption Corresponds To Decreased Incidence Of Ventricular Fibrillation In A Commotio Cordis Model, Kayt E. Frisch, Mark S. Link, John Van Weelden
Faculty Work Comprehensive List
A healthy teenage boy is playing high school baseball, when he is struck in the chest by the ball; minutes later, his heart is experiencing ventricular fibrillation (VF) and the only way to resuscitate him is to use a defibrillator. This phenomenon, is known as Commotio Cordis (CC), and occurs as many as 20 times each year in the United States. CC most frequently occurs in sports with small balls (e.g. baseball or lacrosse) and requires a specific set of circumstances–a projectile with a certain amount of energy that impacts directly over the left ventricle of the heart during a …
Biomimetic Seal Flipper Test Rig, Gordon D. Belyea, Laura Kawashiri, Dylan Rinker, Kurt Beske
Biomimetic Seal Flipper Test Rig, Gordon D. Belyea, Laura Kawashiri, Dylan Rinker, Kurt Beske
Mechanical Engineering
No abstract provided.
Non-Puncturing, No Slip Thv Leaflet Gripper, Brooks Kelly, Eric Nagaoka, Johnny Phane
Non-Puncturing, No Slip Thv Leaflet Gripper, Brooks Kelly, Eric Nagaoka, Johnny Phane
Mechanical Engineering
Confidential
Low-Cost Prosthetic Transfemoral Socket, Emelie Deans, Joshua Ledgerwood, Leah Moore, Shaina Jung, Kristen Temnyk
Low-Cost Prosthetic Transfemoral Socket, Emelie Deans, Joshua Ledgerwood, Leah Moore, Shaina Jung, Kristen Temnyk
Mechanical Engineering
The goal of this senior project was to design and fabricate a low-cost adjustable prosthetic socket for above the knee amputees. This low-cost consideration was incorporated with the original intent to be used in Fiji, however, this changed to the Dominican Republic. It became clear that the need for an adjustable socket was more as a transitional socket. This transitional socket would be used for the first 6 -12 months upon amputation because this when the most amount of volume fluctuation occurs. The project sponsor, LIM Innovations, has already designed the Infinite Socket which contains four main functioning parts: baseplate, …
Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai
Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai
Mechanical Engineering
A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …
The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco
The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco
Master's Theses
Osteoarthritis (OA) is a degenerative disease of cartilage and bone tissue and the most common form of arthritis, accounting for US$ 10.5 billion in hospital charges in 2006. Obesity (OB) has been linked to increased risk of developing knee OA due to increased knee joint loads and varus-valgus misalignment. Walking is recommended as a weight-loss activity but it may increase risk of knee OA as OB gait increases knee loads. Cycling has been proposed as an alternative weight-loss measure, however, lack of studies comparing normal weight (NW) and OB subjects in cycling and gait hinder identification of exercises that may …
Numerical Modeling Of Fluid-Porous Structure Interaction In Arteries, Rana Zakerzadeh, Paolo Zunino
Numerical Modeling Of Fluid-Porous Structure Interaction In Arteries, Rana Zakerzadeh, Paolo Zunino
Biology and Medicine Through Mathematics Conference
No abstract provided.
Walking Simulator Mechanism, Titus Lungu, Igor Tachynskyy, Omri Tayyara
Walking Simulator Mechanism, Titus Lungu, Igor Tachynskyy, Omri Tayyara
The Downtown Review: An Interdisciplinary Journal Written and Peer-Reviewed by Mandel Honors College Students at Cleveland State University
This paper presents the design, simulation, and kinematic evaluation of a mechanism aimed at simulating both the motion and ground reaction forces produced by a human foot while walking. Such a mechanism can be used to test the durability of shoes through life cycle analysis. In attempting to mimic the physical motion of the human foot as closely as possible, the forces experienced by the human foot were also accurately replicated through the incorporation of a non-stationary testing platform. As is shown in the paper, this testing environment allows for simple adjustments to be made in order to simulate different …
Atomic Force Microscopy Based Dna Analysis, Drew Creighton
Atomic Force Microscopy Based Dna Analysis, Drew Creighton
Mechanical Engineering Undergraduate Honors Theses
This report explores dry and wet scanning of a surface and DNA pickup using an AFM, as well as fluorescent staining of DNA. Dry and wet scans of DNA were obtained using a cantilever AFM tip in tapping mode. Dry scans were found to be clearer than wet scans; however, the drying process was found to decrease the thickness of DNA 2–4 times less than its original thickness. Alternately, wet scans were found to be less clear than dry scans and introduced more noise into the images obtained. Additionally, DNA kept its initial thickness during wet scanning. DNA was capable …
Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li
Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li
UNLV Theses, Dissertations, Professional Papers, and Capstones
An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …
Mild Traumatic Brain Injury: Combined In Silico And In Vitro Studies, Yi Hua
Mild Traumatic Brain Injury: Combined In Silico And In Vitro Studies, Yi Hua
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Mild traumatic brain injury (TBI) is a significant public health concern worldwide and has attracted significant attention due to high-impact sport as well as improvised explosive devices used in military conflicts. The earliest sign of mild TBI is associated with cognitive, behavioral and physical/somatic changes, which are commonly invisible to existing medical techniques. Thus it is essential to target mechanisms of mild TBI and its associated damage measures for earlier diagnosis/treatment and enhanced protection strategies.
In this work, the mechanism of blast-induced mild TBI was inspected through integrated in silico and in vitro models. A three-dimensional (3D) human head model …
Design And Testing Of Robotic Capsule Biosensors In The Small Intestine, Zachary Bram
Design And Testing Of Robotic Capsule Biosensors In The Small Intestine, Zachary Bram
Robotics and Mechanical Systems Design
Biosensors are a tool that is growing in usage and is sought out by doctors and patients alike for being a non-invasive method to monitor health. The data that can be collected from these sensors can be analyzed by doctors that are away from patients, or even by patients that do not have the ability to see a doctor. The purpose of this work is to design and test a biosensor capsule that can attach itself to the inner wall of the small intestine for a short period of time before exiting the body. This research project was a continuation …
A Retrospective Study Of Amusement Ride Restraint And Containment Systems: Identifying Design Challenges For Statistically Rare Anthropometric Cases, Paula M. Stenzler
A Retrospective Study Of Amusement Ride Restraint And Containment Systems: Identifying Design Challenges For Statistically Rare Anthropometric Cases, Paula M. Stenzler
Engineering Management & Systems Engineering Theses & Dissertations
The intent of this project was to conduct a retrospective study of amusement ride restraint and containment systems’ failures to identify the challenges associated with existing design criteria to safely accommodate statistically rare groups that fall outside amusement industry standards. Innovations in ride technology provide an opportunity for injuries to occur if restraint and containment systems cannot properly accommodate unique patron anthropometry. It is paramount to understand how anthropometric features contribute to the patron’s ability to defeat ride restraint and containment systems. A systemic perspective was used based on industry accident data to frame the problem associated with restraint and …
Design And Analysis Of A Lift Assist Walker, Deep P. Shah
Design And Analysis Of A Lift Assist Walker, Deep P. Shah
Master's Theses
Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.
Assessment Of Force Coordination And Neuromuscular Quickness In Healthy Adults, Karen L. Haberland
Assessment Of Force Coordination And Neuromuscular Quickness In Healthy Adults, Karen L. Haberland
Theses and Dissertations
Throughout daily life, it is necessary to handle and control innumerable objects. To do so, one’s hands must be precisely regulated. To ensure that an object is effectively manipulated, an individual must apply a grip force (GF) perpendicular to the object’s surface to overcome load force (LF), which acts tangential to the surface to counteract the object’s weight and inertia. Previous studies have shown an elaborate coordination between GF and LF in a variety of object manipulation tasks in healthy populations. This kinetic analysis is clinically important because the GF-LF coordination is shown to deteriorate in aging and neurologically impaired …
Characterization Of Piezoelectric Device For Implanted Pacemaker Energy Harvesting, Sunny Jay, Manuel Caballero, William Quinn, John Barrett, Martin Hill
Characterization Of Piezoelectric Device For Implanted Pacemaker Energy Harvesting, Sunny Jay, Manuel Caballero, William Quinn, John Barrett, Martin Hill
Conference Papers
Novel implanted cardiac pacemakers that are powered by energy harvesters driven by the cardiac motion and have a 40 year lifetime are currently under development. To satisfy space constraints and energy requirements of the device, silicon-based MEMS energy harvesters are being developed in the EU project (MANpower). Such MEMS harvesters for vibration frequencies below 50 Hz have not been widely reported. In this paper, an analytical model and a 3D finite element model (FEM) to predict displacement and open circuit voltage, validated through experimental analysis using an off-the-shelf low frequency energy harvester, are presented. The harvester was excited through constant …
Efficiency Evaluation Of A Magnetically Driven Multiple Disk Centrifugal Blood Pump, Kayla H. Moody
Efficiency Evaluation Of A Magnetically Driven Multiple Disk Centrifugal Blood Pump, Kayla H. Moody
Theses and Dissertations
Heart failure is expected to ail over 8 million people in America by 2030 leaving many in need of cardiac replacement. To accommodate this large volume of people, ventricular assist devices (VADs) are necessary to provide mechanical circulatory support. Current VADs exhibit issues such as thrombosis and hemolysis caused by large local pressure drops and turbulent flow within the pump. Multiple disk centrifugal pumps (MDCPs) use shearing and centrifugal forces to produce laminar flow patterns and eliminate large pressure drops within the pump which greatly reduce risks that are in current VADs. The MDCP has a shaft drive system (SDS) …
Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon
Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon
Mechanical & Aerospace Engineering Faculty Publications
The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial …
Biventricular Finite Element Modeling And Quantification Of 3d Langragian Strains And Torsion Using Dense Mri, Zhanqiu Liu
Biventricular Finite Element Modeling And Quantification Of 3d Langragian Strains And Torsion Using Dense Mri, Zhanqiu Liu
Theses and Dissertations--Mechanical and Aerospace Engineering
Statistical data suggests that increased use of evidence-based medical therapies has largely contributed to the decrease in American death rate caused by heart disease. And my studies are about two applications of magnetic resonance imaging (MRI) as a non-invasive approach in evidence-based health care research. In my first study, the achievement of a pulmonary valve replacement surgery was assessed on a patient with tetralogy of Fallot (TOF). In order to evaluate the remodeling of right ventricle, two biventricular finite element models were built up for pre-surgical images and post-surgical images. In my second study, 3D Lagrangian strains and torsion in …
A Nocsae Drop Test/ 3d-Fem Study On The Relationship Between Kinematic Response Of The Head, Head Impact Contact Pressure (Hicp) And Kinetic Response Of The Brain To Delineate The Risk Of Traumatic Brain Injuries (Tbi)., Raghavendra Krishna Tej Bhamidipati
A Nocsae Drop Test/ 3d-Fem Study On The Relationship Between Kinematic Response Of The Head, Head Impact Contact Pressure (Hicp) And Kinetic Response Of The Brain To Delineate The Risk Of Traumatic Brain Injuries (Tbi)., Raghavendra Krishna Tej Bhamidipati
Dissertations, Master's Theses and Master's Reports
How many times have you seen a person slip and fall down and had a good laugh about it? How many times we slip and fall down on the floor and got up and walked away thinking everything is normal? Probably we might wonder “Are drops which occur at a small height dangerous?” Yes, they can be. Brain injuries are main reason for the fatality in youth [1], and low level falls are one of the most neglected and understated injuries.
The main objective of this study is to study the response of the brain for low level falls from …
Finite Element Modeling Of Active And Passive Behavior Of The Human Tibialis Anterior: A Preliminary Approach, David Joda
Dissertations, Master's Theses and Master's Reports
This research project serves as exploratory work in the field of computational human biomechanics. A connection between muscular force and intramuscular pressure (IMP) has been uncovered that could prove invaluable in medical diagnostics as a method to circumvent the use of electromyography.
Preliminary finite element simulations were conducted to model the human tibialis anterior muscle in passive lengthening and active contraction. These simulations, totaling over 50 unique runs, utilized a novel constitutive model developed within the IMP research group. Volumetric strain, reaction forces, and pressure gradients were compared to data acquired from ongoing in vivo human experiments. A mechanism for …
Finite Element And Probabilistic Analysis Of Soft Tissue Structures Of The Human Lumbar Spine, Dana Joseph Coombs
Finite Element And Probabilistic Analysis Of Soft Tissue Structures Of The Human Lumbar Spine, Dana Joseph Coombs
Electronic Theses and Dissertations
Human lumbar spine mechanics are influenced by soft tissue structures. Understanding and properly modeling these structures can help determine pathology, treatment, and implant design and performance. Finite element models of the L4-L5 level of the lumbar spine are often used, which include a representation of the intervertebral disc and spinal ligaments. Validation of these models are typically based on torque rotation data from a single subject or the models use average properties reported in literature. However, experimental testing reports variation up to 40% in ligament stiffness and even greater variability for annulus fibrosis properties. Probabilistic approaches enable consideration of the …
Statistical Modeling To Investigate Anatomy And Function Of The Knee, Lowell Matthew Smoger
Statistical Modeling To Investigate Anatomy And Function Of The Knee, Lowell Matthew Smoger
Electronic Theses and Dissertations
The natural knee is a hinge joint with significant functional requirements during activities of daily living; as a result, acute and chronic injuries can occur. Pathologies are influenced by joint anatomy and may include patellar maltracking, cartilage degeneration (e.g. osteoarthritis), or acute injuries such as meniscal or ligamentous tears. Population variability makes broadly applicable conclusions about etiology of these conditions from small-scale investigations challenging. The work presented in this dissertation is a demonstration of statistical modeling approaches to evaluate population variability in anatomy of the knee and function of its tibiofemoral (TF) and patellofemoral (PF) joints. Three-dimensional (3D) computational models …