Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

2014

Discipline
Institution
Keyword
Publication
Publication Type

Articles 1 - 30 of 34

Full-Text Articles in Biomechanical Engineering

A Microstructural Constitutive Framework For Injured Ligament, Christina J. Stender, Evan Rust, Raquel J. Brown, Trevor J. Lujan Dec 2014

A Microstructural Constitutive Framework For Injured Ligament, Christina J. Stender, Evan Rust, Raquel J. Brown, Trevor J. Lujan

Biomedical Research Institute Student Presentations

No abstract provided.


Evaluation Of The Mass Transfer Effect Of The Stalk Contraction–Relaxation Cycle Of Vorticella Convallaria, Jiazhong Zhou Dec 2014

Evaluation Of The Mass Transfer Effect Of The Stalk Contraction–Relaxation Cycle Of Vorticella Convallaria, Jiazhong Zhou

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Vorticella convallaria is a genus of protozoa living in fresh water. It has a bell-shaped zooid equipped with adoral ciliary bands and a contractile stalk tethering the zooid to a substrate. Vorticella is regarded as a biological spring because its contractile stalk can pull the zooid towards the substrate at a remarkably high speed and then relaxes to its extended state much more slowly. However, reasons for Vorticella’s stalk contraction are still unknown. It is presumed that the flow field induced by the contraction-relaxation cycle of Vorticella would augment mass transfer effect near the substrate. We investigated this hypothesis …


Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder Dec 2014

Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder

UNLV Theses, Dissertations, Professional Papers, and Capstones

Actuators determine the performance of robotic systems at the most intimate of levels. As a result, much work has been done to assess the performance of different actuator systems. However, biomimetics has not previously been utilized as a pretext for tuning a series elastic actuator system with the purpose of designing an empirical testing platform. Thus, an artificial muscle tendon system has been developed in order to assess the performance of two distinct actuator types: (1) direct current electromagnetic motors and (2) ultrasonic rotary piezoelectric motors. Because the design of the system takes advantage of biomimetic operating principles such as …


Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young Dec 2014

Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young

UNLV Theses, Dissertations, Professional Papers, and Capstones

Mesenchymal stem cells are derived from a variety of human tissues and are being bioengineered and studied for possible uses in the advancement of medicine. Recent efforts are being focused on Dental Pulp Stem Cells (DPSC's) due to the accessibility of this tissue. Many factors influence DPSC quality and quantity, including the specific methods used to isolate, collect, concentrate, and store these isolates once they are removed. Ancillary factors, such as the choice of media, the selection of early versus late passage cells, and cryopreservation techniques may also influence the differentiation potential and proliferative capacity of DPSC isolates.

The objective …


Team Nathan Suspension, Frankie J. Wiggins, Alex D. Seitz, Justin P. Bautista Oct 2014

Team Nathan Suspension, Frankie J. Wiggins, Alex D. Seitz, Justin P. Bautista

Mechanical Engineering

Nathan Cooper is an 8-year old boy with Spinal Muscular Atrophy (SMA). SMA has affected Nathan’s muscle development and requires him to use the Standing Dani™ mobility device. The Standing Dani is a motorized standing wheelchair, or Wheelstand. Nathan controls and uses it to get around. Though the Standing Dani performs well for most functions, it has some distinct issues. The primary issue that this project addresses is its lack of suspension and the discomfort that Nathan feels as a result. After talking with our client, we developed several specifications generally related to geometry, safety, vehicle dynamics, and reliability. Many …


Within-Socket Myoelectric Prediction Of Continuous Ankle Kinematics For Control Of A Powered Transtibial Prosthesis, Samuel Farmer, M. Barbara Silver-Thorn, Philip A. Voglewede, Scott A. Beardsley Oct 2014

Within-Socket Myoelectric Prediction Of Continuous Ankle Kinematics For Control Of A Powered Transtibial Prosthesis, Samuel Farmer, M. Barbara Silver-Thorn, Philip A. Voglewede, Scott A. Beardsley

Biomedical Engineering Faculty Research and Publications

Objective. Powered robotic prostheses create a need for natural-feeling user interfaces and robust control schemes. Here, we examined the ability of a nonlinear autoregressive model to continuously map the kinematics of a transtibial prosthesis and electromyographic (EMG) activity recorded within socket to the future estimates of the prosthetic ankle angle in three transtibial amputees. Approach. Model performance was examined across subjects during level treadmill ambulation as a function of the size of the EMG sampling window and the temporal 'prediction' interval between the EMG/kinematic input and the model's estimate of future ankle angle to characterize the trade-off between model error, …


A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien Sep 2014

A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien

Conference Papers

The field of heart valve biology and tissue engineering a heart valve continue to expand. The presentatio ns at this meeting reflect the advances made in both areas due to the multi-disciplinary approach taken by many laboratories.


Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu Sep 2014

Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu

Department of Mechanical and Materials Engineering: Faculty Publications

A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …


A Method To Develop Neck Injury Criteria To Aid Design And Test Of Escape Systems Incorporating Helmet Mounted Displays, Jeffrey C. Parr Sep 2014

A Method To Develop Neck Injury Criteria To Aid Design And Test Of Escape Systems Incorporating Helmet Mounted Displays, Jeffrey C. Parr

Theses and Dissertations

HMDs are becoming common human-machine interface equipment in manned military flight, but introducing this equipment into the overall aircraft escape system poses new and significant system design, development, and test concerns. Although HMDs add capabilities, which improve operator performance, the increased capability is often accompanied by increased head supported mass. The increased mass can amplify the risk of pilot neck injury during ejection when compared to lighter legacy helmets. Currently no adequate USAF neck injury criteria exist to effectively guide the requirements, design, and test of escape systems for pilots with HMDs. This research effort presents a novel method to …


Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller Aug 2014

Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller

UNLV Theses, Dissertations, Professional Papers, and Capstones

Hypothermia is a life-threatening condition. Currently, active warming methods are the most effective treatment for dysthermic patients. The aim of this study is to investigate the use of computational fluid dynamics (CFD) in evaluating the thermal performance of a parallel/counter-parallel flow heat exchanger used as part of a fluid warmer to treat Hypothermia. The 3D model of the heat exchanger is divided into three regions; Infusate (fluid to be heated), Hot Water (heating fluid), and a Solid Region (wall). At the end of the heat exchanger, an elbow section is used to create the counter-parallel flow arrangement specific to this …


Understanding The Effects Of Blast Wave On The Intracranial Pressure And Traumatic Brain Injury In Rodents And Humans Using Experimental Shock Tube And Numerical Simulations, Aravind Sundaramurthy Jul 2014

Understanding The Effects Of Blast Wave On The Intracranial Pressure And Traumatic Brain Injury In Rodents And Humans Using Experimental Shock Tube And Numerical Simulations, Aravind Sundaramurthy

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

Blast induced neurotrauma (BINT) has been designated as the “signature injury” to warfighters in the recent military conflicts. In the past decade, conflicts in Iraq (operation Iraqi freedom) and Afghanistan (operation enduring freedom) as well as the increasing burden of the terrorism around the world resulted in an increased number of cases with blast Traumatic Brain Injury (bTBI). Recently, a lot of research has been done to study the neurological and neurochemical degenerations resulting from BINT using animal models especially rat models. However, it is not clear how and whether the biological outcomes from animal models can be translated to …


Real-Time Simulation Of Three-Dimensional Shoulder Girdle And Arm Dynamics, Edward K. Chadwick, Dimitra Blana, Robert F. Kirsch, Antonie J. Van Den Bogert Jul 2014

Real-Time Simulation Of Three-Dimensional Shoulder Girdle And Arm Dynamics, Edward K. Chadwick, Dimitra Blana, Robert F. Kirsch, Antonie J. Van Den Bogert

Mechanical Engineering Faculty Publications

Electrical stimulation is a promising technology for the restoration of arm function in paralyzed individuals. Control of the paralyzed arm under electrical stimulation, however, is a challenging problem that requires advanced controllers and command interfaces for the user. A real-time model describing the complex dynamics of the arm would allow user-in-the-loop type experiments where the command interface and controller could be assessed. Real-time models of the arm previously described have not included the ability tomodel the independently controlled scapula and clavicle, limiting their utility for clinical applications of this nature. The goal of this study therefore was to evaluate the …


Design Of A Passive Ankle Prosthesis With Powered Push-Off Using A Cam Timing Mechanism, Jacob J. Rice Jul 2014

Design Of A Passive Ankle Prosthesis With Powered Push-Off Using A Cam Timing Mechanism, Jacob J. Rice

Master's Theses (2009 -)

This thesis presents the design and simulation results of the CamWalk, a novel passive prosthetic ankle that has mechanical behavior similar to that for a natural ankle. The CamWalk uses a compression spring network that allows coupling between two degrees of freedom; one for translation along the leg and another for rotation about the ankle joint. When walking, potential energy from the person's weight is stored in the spring network in deflection along the leg. The energy is released by the network as rotation of the foot. The amount of translational work that is converted to rotational work about the …


Implementation Of Analytical Fatigue Models Into Opensim To Predict The Effects Of Fatigue On Anterior Cruciate Ligament Loading, Michael A. Samann Jul 2014

Implementation Of Analytical Fatigue Models Into Opensim To Predict The Effects Of Fatigue On Anterior Cruciate Ligament Loading, Michael A. Samann

Mechanical & Aerospace Engineering Theses & Dissertations

The anterior cruciate ligament (ACL) provides stability to the knee joint while performing activities such as a side step cut. Neuromuscular fatigue, a reduction in muscle force producing capabilities, alters lower extremity mechanics while performing a side step cut and may increase the risk of ACL injury, particularly in females. Musculoskeletal modeling allows for the measurement of muscle forces, which are difficult to measure in-vivo. Therefore, musculoskeletal modeling, may improve our understanding of the effects of neuromuscular fatigue on muscle force production and loading of the ACL. Therefore, the purpose of this study was to develop a musculoskeletal model which …


Relationship Between Jump Landing Kinematics And Peak Acl Force During A Jump In Downhill Skiing: A Simulation Study, D. Heinrich, Antonie J. Van Den Bogert, W. Nachbauer Jun 2014

Relationship Between Jump Landing Kinematics And Peak Acl Force During A Jump In Downhill Skiing: A Simulation Study, D. Heinrich, Antonie J. Van Den Bogert, W. Nachbauer

Mechanical Engineering Faculty Publications

Recent data highlight that competitive skiers face a high risk of injuries especially during off-balance jump landing maneuvers in downhill skiing. The purpose of the present study was to develop a musculo-skeletal modeling and simulation approach to investigate the cause-and-effect relationship between a perturbed landing position, i.e., joint angles and trunk orientation, and the peak force in the anterior cruciate ligament (ACL) during jump landing. A two-dimensional musculo-skeletal model was developed and a baseline simulation was obtained reproducing measurement data of a reference landing movement. Based on the baseline simulation, a series of perturbed landing simulations (n=1000) was generated. Multiple …


Low-Cost Strider For Guatemala, Nicole Catherine Cooper, Gonzalo Hernandez, Jared W. Tower Jun 2014

Low-Cost Strider For Guatemala, Nicole Catherine Cooper, Gonzalo Hernandez, Jared W. Tower

Mechanical Engineering

The purpose of this project was to create a strider, a type of standing rehabilitation device, for children in developing countries who have trouble walking and supporting their full body weight. The project was initially brought to us by Cal Poly professor Brian Self, who had visited a clinic in San Marcos and determined that there were children there who had difficulties with walking and were a need for a rehabilitation device. The team discussed the problem with Dr. Self, Matt Robinson (a local San Luis Obispo prosthetist), and Cal Poly physics professor Pete Schwartz, all of whom had visited …


2d Wireform Process Improvement, Katy Conlin, Carlo Ebora, Jordan Gamble Jun 2014

2d Wireform Process Improvement, Katy Conlin, Carlo Ebora, Jordan Gamble

Mechanical Engineering

The body of this work has been created for Edwards Lifesciences in conjunction with senior project requirements. As such, the information produced and contained within is under a non‐disclosure agreement. As per request by sponsor, the body of the work will not be submitted to any outside parties, and the title page will serve as proof of completion.


Semi-Automated Method Of Assembly For Physio Ii Ring, Cameron Anderson Deines, Kelsey Jean Engel, Christopher Kiuyen Wong Jun 2014

Semi-Automated Method Of Assembly For Physio Ii Ring, Cameron Anderson Deines, Kelsey Jean Engel, Christopher Kiuyen Wong

Mechanical Engineering

No abstract provided.


Folding Wheelchair Improvement, Matthew Edison Grace, Kevin Alan Miyamoto, Andrey Lee Oliveira Jun 2014

Folding Wheelchair Improvement, Matthew Edison Grace, Kevin Alan Miyamoto, Andrey Lee Oliveira

Mechanical Engineering

No abstract provided.


Multi-Muscle Fes Force Control Of The Human Arm For Arbitrary Goals, Eric M. Schearer, Yu-Wei Liao, Eric J. Perreault, Matthew C. Tresch, William D. Memberg, Robert F. Kirsch, Kevin M. Lynch May 2014

Multi-Muscle Fes Force Control Of The Human Arm For Arbitrary Goals, Eric M. Schearer, Yu-Wei Liao, Eric J. Perreault, Matthew C. Tresch, William D. Memberg, Robert F. Kirsch, Kevin M. Lynch

Mechanical Engineering Faculty Publications

We present a method for controlling a neuroprosthesis for a paralyzed human arm using functional electrical stimulation (FES) and characterize the errors of the controller. The subject has surgically implanted electrodes for stimulating muscles in her shoulder and arm. Using input/output data, a model mapping muscle stimulations to isometric endpoint forces measured at the subject’s hand was identified. We inverted the model of this redundant and coupled multiple-input multiple-output system by minimizing muscle activations and used this inverse for feedforward control. The magnitude of the total root mean square error over a grid in the volume of achievable isometric endpoint …


Application Of Limited Mixing In The Hele–Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman Apr 2014

Application Of Limited Mixing In The Hele–Shaw Geometry In Fabrication Of Janus Hydrogels, Md Mahmudur Rahman

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

It is widely accepted that cells behave differently responding to the stiffness of their extracellular matrix (ECM). Such observations were made by culturing cells on hydrogel substrates of tunable stiffness. However, it was recently proposed that cells may sense how strongly they are tethered to ECM, not the local stiffness of ECM. To investigate both hypotheses, we developed a method to fabricate Janus polyacrylamide (PAAM) gels. We squeeze two drops of different concentrations in the Hele-Shaw geometry to generate radial Stokes flow. When the drops coalesce, limited mixing occurs at the interface due to the narrow confinement, and diffusion normal …


Junior Design: Automatic Page Turner, Matthew Stewart, Jesse Mcintire, Seth Tilson, Hector Ortiz, Ed Meserve Apr 2014

Junior Design: Automatic Page Turner, Matthew Stewart, Jesse Mcintire, Seth Tilson, Hector Ortiz, Ed Meserve

Thinking Matters Symposium Archive

This project details the design and build process of an automatic pageturner. The primary goal of this project is to design and manufacture a product that not only has an efficient operation, but is easy to use for people with disabilities and minimal assistance. The device will consist of a mechanical structure to support the book, an electrical system to facilitate the turning of pages in both directions, and additional features to support comfort and readability, such as LED reading lights.


Hand Prosthesis, Tru Nguyen, Aaron Delano, Kyle M. Green, Jorge Maderal, Cody Poland Apr 2014

Hand Prosthesis, Tru Nguyen, Aaron Delano, Kyle M. Green, Jorge Maderal, Cody Poland

Thinking Matters Symposium Archive

This project deals with engineering students’ prosthetic hand design, submitted to the University of Southern Maine’s engineering department. The primary goal of the prosthetic hand design is to allow an impaired individual to grasp and hold everyday objects ranging from a toothbrush to a jug of milk. The project consists of three teams each designing their respective portion of the prosthetic device. The teams will deal with three specific design areas; computer aided design of the mechanism, electronic integration, and manufacturing implementation. The design team turns notebook doodles into virtual models in SolidWorks. The electronics team will control a battery …


Numerical And Experimental Investigation Of Orthopaedic Fracture Fixation, Bipinchandra Patel Apr 2014

Numerical And Experimental Investigation Of Orthopaedic Fracture Fixation, Bipinchandra Patel

Dissertations

Poor bone fracture fixation leads to malunion, delayed union, non-union, or infection. These malunited fractures affect a bone’s ability to carry loads. Patient outcomes regarding fixation quality can be affected by the healing environment and human factors such as bone quality and surgeons’ perception. Furthermore, the stiffness and strength of the screw-plate construct affect the healing environment. Therefore, this dissertation investigates the stiffness and strength of the non-locking (conventional) and locking (fixed angle) type screw-plate constructs and the factors that contribute to them, such as screw-plate interface, screw design, bone density, cortical bone thickness and load orientation. Additionally, the surgeon’s …


Expressing The Joint Moments Of Drop Jumps And Sidestep Cutting In Different Reference Frames – Does It Matter?, Eirik Kristianslunda, Tron Krosshauga, Kam-Ming Mok, Scott Mclean, Antonie J. Van Den Bogert Jan 2014

Expressing The Joint Moments Of Drop Jumps And Sidestep Cutting In Different Reference Frames – Does It Matter?, Eirik Kristianslunda, Tron Krosshauga, Kam-Ming Mok, Scott Mclean, Antonie J. Van Den Bogert

Mechanical Engineering Faculty Publications

Joint moments help us understand joint loading and muscle function during movement. However, the interpretation depends on the choice of reference frame, but the different reference frames have not been compared in dynamic, high-impact sporting movements. We have compared the magnitude and the resulting ranking of hip and knee joint moments expressed in the laboratory coordinate system, the local system of the distal segment and projected or decomposed to the Joint Coordinate System (JCS) axes. Hip and knee joint moments of drop jumps and sidestep cutting in 70 elite female handball players were calculated based on recordings from an eight-camera …


Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza Jan 2014

Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza

Theses and Dissertations

Muscle mechanical behavior potentially plays an important role in some of the most common bladder disorders. These include overactive bladder, which can involve involuntary contractions during bladder filling, and impaired contractility or underactive bladder, which may involve weak or incomplete contractions during voiding. Actin-myosin cross-bridges in detrusor smooth muscle (DSM) are responsible for contracting and emptying the bladder. The total tension produced by muscle is the sum of its preload and active tensions. Studies suggest that actin-myosin cross-links are involved in adjustable preload stiffness (APS), which is characterized by a preload tension curve that can be shifted along the length …


Modeling Acute Changes In Bladder Wall Tension, Shape And Compliance During Filling, Firdaweke Habteyes Jan 2014

Modeling Acute Changes In Bladder Wall Tension, Shape And Compliance During Filling, Firdaweke Habteyes

Theses and Dissertations

The bladder wall consists primarily of detrusor smooth muscle. Tension-sensitive nerves in the bladder wall are responsible for providing bladder fullness information that is interpreted as urgency. Bladder wall tension, and therefore nerve output, is a function of bladder volume, shape and material properties. Studies have shown that the bladder wall exhibits acutely regulated detrusor compliance. In addition, bladder shape throughout filling depends on intra-abdominal forces and material properties of the bladder wall, such as regulated detrusor compliance. This thesis focused on modeling the potential influence of acute changes in bladder compliance, shape and bladder wall tension during filling. Laplace’s …


Computational Investigation Of Injectable Treatment Strategies For Myocardial Infarction, Hua Wang Jan 2014

Computational Investigation Of Injectable Treatment Strategies For Myocardial Infarction, Hua Wang

Theses and Dissertations--Mechanical and Aerospace Engineering

Heart failure is an important medical disease and impacts millions of people throughout the world. In order to treat this problem, biomaterial injectable treatment injected into the myocardium of the failing LV are currently being developed. Through this treatment, the biomaterial material injections can reduce wall stresses during the cardiac remodeling process. By using computational techniques to analyze the effects of a treatment involving the injection of biomaterial material into the LV after MI, the material parameters of the hydrogel injections can be optimized. The results shows that the hydrogel injections could reduce the global average fiber stress and the …


Estimating Passive Material Properties And Fiber Orientation In A Myocardial Infarction Through An Optimization Scheme Using Mri And Fe Simulation, Dimitri Mojsejenko Jan 2014

Estimating Passive Material Properties And Fiber Orientation In A Myocardial Infarction Through An Optimization Scheme Using Mri And Fe Simulation, Dimitri Mojsejenko

Theses and Dissertations--Mechanical and Aerospace Engineering

Myocardial infarctions induce a maladaptive ventricular remodeling process that independently contributes to heart failure. In order to develop effective treatments, it is necessary to understand the way and extent to which the heart undergoes remodeling over the course of healing. There have been few studies to produce any data on the in-vivo material properties of infarcts, and much less on the properties over the time course of healing. In this paper, the in-vivo passive material properties of an infarcted porcine model were estimated through a combined use of magnetic resonance imaging, catheterization, finite element modeling, and a genetic algorithm optimization …


Fabrication Of Magnetic Two-Dimensional And Three-Dimensional Microstructures For Microfluidics And Microrobotics Applications, Hui Li Jan 2014

Fabrication Of Magnetic Two-Dimensional And Three-Dimensional Microstructures For Microfluidics And Microrobotics Applications, Hui Li

Theses and Dissertations--Mechanical and Aerospace Engineering

Micro-electro-mechanical systems (MEMS) technology has had an increasing impact on industry and our society. A wide range of MEMS devices are used in every aspects of our life, from microaccelerators and microgyroscopes to microscale drug-delivery systems. The increasing complexity of microsystems demands diverse microfabrication methods and actuation strategies to realize. Currently, it is challenging for existing microfabrication methods—particularly 3D microfabrication methods—to integrate multiple materials into the same component. This is a particular challenge for some applications, such as microrobotics and microfluidics, where integration of magnetically-responsive materials would be beneficial, because it enables contact-free actuation. In addition, most existing microfabrication methods …