Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Biomechanical Engineering

Multiphase Cfd Modelling And Piv Validation Of A Uasb Reactor, Camila D' Bastiani, Jéferson Luis Alba, Gabriel Tomazzoni Mazzarotto, Severino Rodrigues De Farias Neto, Lademir Luiz Beal, Anthony Reynolds, David Kennedy Jan 2019

Multiphase Cfd Modelling And Piv Validation Of A Uasb Reactor, Camila D' Bastiani, Jéferson Luis Alba, Gabriel Tomazzoni Mazzarotto, Severino Rodrigues De Farias Neto, Lademir Luiz Beal, Anthony Reynolds, David Kennedy

Conference Papers

Upflow anaerobic sludge blanket (UASB) reactors stand out as a feasible option for treating wastewaters while generating a valuable amount of biogas. It is known that the efficiency of UASB reactors is closely linked to its hydrodynamics. Therefore, understanding the role of each phase (solids, liquid and gas) in the mixing conditions inside the reactor and having validated numerical models for predicting the flow behavior has become fundamental for the design and optimization of UASB reactors. In this context this work aims to develop and validate a three phase Computational Fluid Dynamics (CFD) model of an UASB reactor. Eulerian-Eulerian laminar …


Characterization Of Piezoelectric Device For Implanted Pacemaker Energy Harvesting, Sunny Jay, Manuel Caballero, William Quinn, John Barrett, Martin Hill Jan 2016

Characterization Of Piezoelectric Device For Implanted Pacemaker Energy Harvesting, Sunny Jay, Manuel Caballero, William Quinn, John Barrett, Martin Hill

Conference Papers

Novel implanted cardiac pacemakers that are powered by energy harvesters driven by the cardiac motion and have a 40 year lifetime are currently under development. To satisfy space constraints and energy requirements of the device, silicon-based MEMS energy harvesters are being developed in the EU project (MANpower). Such MEMS harvesters for vibration frequencies below 50 Hz have not been widely reported. In this paper, an analytical model and a 3D finite element model (FEM) to predict displacement and open circuit voltage, validated through experimental analysis using an off-the-shelf low frequency energy harvester, are presented. The harvester was excited through constant …


A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien Sep 2014

A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien

Conference Papers

The field of heart valve biology and tissue engineering a heart valve continue to expand. The presentatio ns at this meeting reflect the advances made in both areas due to the multi-disciplinary approach taken by many laboratories.


Development Of A Robotic Platform For Upper Limb Rehabilitation, Stephen Curran, Nigel Kent, David Kennedy, James Conlon Jan 2012

Development Of A Robotic Platform For Upper Limb Rehabilitation, Stephen Curran, Nigel Kent, David Kennedy, James Conlon

Conference Papers

The aim of this project is to develop a rehabilitation robot intended for use in a non-specialised or domestic setting. Robots have been shown to have a positive effect on limb rehabilitation and developing rehabilitation robots for use outside of specialist rehabilitation centres could be beneficial in terms of access to, intensity and cost of treatment. The device is intended for the rehabilitation of the shoulder/elbow region of the upper limbs. The design requirements for such a device mean that it must be low cost, portable, robust and have a detailed focus on safety. Other areas of interest pertaining to …


Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane Jan 2011

Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane

Conference Papers

A crucial aspect of orthopaedic implant design is the prediction of surgical outcomes when the shape of a bone is necessarily altered by the addition of the implant. Matching native kinematics as closely as possible is generally considered a core aim of joint replacement surgery. The overall hypothesis behind this research is that soft tissue geometry, including cartilage thickness distribution and ligament attachment sites, influences kinematics in the knee joint. In order to enable investigation of possible links between geometry and kinematics, the ability to characterise the shape variation of the soft tissue relative to the underlying bony geometry must …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


An Analysis Of The Performance Of Foams Used In Hurling Helmets, Keith Norris, Stephen Tiernan May 2008

An Analysis Of The Performance Of Foams Used In Hurling Helmets, Keith Norris, Stephen Tiernan

Conference Papers

Abstract Head injuries can occur in most sporting activities. The seriousness of these injuries can vary greatly depending on the sport. Many sports such as American football, cricket, baseball and hurling try to reduce this risk by designing helmets that are suitable to be worn by the players. The National Standard Authority of Ireland (NSAI) has recently made great strides in this area with the introduction of the first comprehensive standard adopted for the sport I.S. 355:2006, which sets out new testing procedures that all new helmets must meet. The Gaelic Athletic Association (GAA) has also stated its intention to …