Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Master's Theses

Discipline
Institution
Keyword
Publication Year

Articles 1 - 30 of 34

Full-Text Articles in Biomechanical Engineering

Design And Evaluation Of An Assistive Powered Hand Orthosis For Grasp Activities For People Post-Stroke, Sydney Alexander Jun 2026

Design And Evaluation Of An Assistive Powered Hand Orthosis For Grasp Activities For People Post-Stroke, Sydney Alexander

Master's Theses

After suffering a stroke, many survivors experience physical disability that affects their ability to complete daily tasks using their hands. Physical therapy is often pre scribed to people post-stroke, but is not fully effective at restoring hand function. The goal of this project was to design and fabricate an assistive device for people post-stroke to help with grasp and release. The device was designed to address com mon shortcomings of existing similar devices. State of the art devices in this domain were investigated to determine a set of design improvements. A novel motor-actuated hand orthosis was designed to decrease weight, …


3d Printed Microfluidic Fabrication Methodology, Characterization, Mechanical Design, And Applications In Electrostatic Artificial Muscles And Benthic Microbial Fuel Cells, Terak B. Hornik Nov 2024

3d Printed Microfluidic Fabrication Methodology, Characterization, Mechanical Design, And Applications In Electrostatic Artificial Muscles And Benthic Microbial Fuel Cells, Terak B. Hornik

Master's Theses

The fabrication of microfluidic devices often requires specialized methods. The development of these methods requires careful characterization and understanding of the processes involved. Using primarily PolyJet 3D printing technology, microfluidics offers a wide scope of applications such as microfluidic benthic microbial fuel cells (MBMFCs) and electrostatic artificial muscles. MBMFCs benefit from the confinement of the microbes resulting in close proximity between the electrode and the organisms. Using a modular design called the Sponge, assembly and upscaling is possible. Electrostatic artificial muscles benefit from a microfluidic approach due to the non-linearity of electrostatic attraction creating disproportionate benefits when miniaturized. When designed …


Validation Of Mobile Devices In Arbitrary Locations Against Force Plate Standard For Balance Assessment, German J. Ellsworth Sep 2024

Validation Of Mobile Devices In Arbitrary Locations Against Force Plate Standard For Balance Assessment, German J. Ellsworth

Master's Theses

With balance assessment being essential to the prediction of fall risk and detection and assessment of motor disorders, increasing clinical accessibility to objective balance metrics is essential. Work has been done validating center of mass (COM) acceleration metrics against well regarded force plate center of pressure (COP) position standards for mobile device data acquisition systems, but most research is restricted to devices being close to the COM or strapped in a harness configuration. Through the use of rigid body kinematics and the inverted pendulum model, this study develops novel methodology for calculating COM acceleration using mobile devices in arbitrary positions, …


Design And Implementation Of A Vision-Based Deep-Learning Protocol For Kinematic Feature Extraction With Application To Stroke Rehabilitation, Juan Diego Luna Inga Jun 2024

Design And Implementation Of A Vision-Based Deep-Learning Protocol For Kinematic Feature Extraction With Application To Stroke Rehabilitation, Juan Diego Luna Inga

Master's Theses

Stroke is a leading cause of long-term disability, affecting thousands of individuals annually and significantly impairing their mobility, independence, and quality of life. Traditional methods for assessing motor impairments are often costly and invasive, creating substantial barriers to effective rehabilitation. This thesis explores the use of DeepLabCut (DLC), a deep-learning-based pose estimation tool, to extract clinically meaningful kinematic features from video data of stroke survivors with upper-extremity (UE) impairments.

To conduct this investigation, a specialized protocol was developed to tailor DLC for analyzing movements characteristic of UE impairments in stroke survivors. This protocol was validated through comparative analysis using peak …


Development Of A Deep Learning Algorithm Using Electromyography (Emg) And Acceleration To Monitor Upper Extremity Behavior With Application To Individuals Post-Stroke, Nathan Dodd Jun 2024

Development Of A Deep Learning Algorithm Using Electromyography (Emg) And Acceleration To Monitor Upper Extremity Behavior With Application To Individuals Post-Stroke, Nathan Dodd

Master's Theses

Stroke is a chronic illness which often impairs survivors for extended periods of time,

leaving the individual limited in motor function. The ability to perform daily activities

(ADL) is closely linked to motor recovery following a stroke. The objective of

this work is to employ surface electromyography (sEMG) gathered through a novel,

wearable armband sensor to monitor and quantify ADL performance. The first contribution

of this work seeks to develop a relationship between sEMG and and grip

aperture, a metric tied to the success of post-stroke individuals’ functional independence.

The second contribution of this work aims to develop a deep …


Finite Element Analysis Of The Bearing Component Of Total Ankle Replacement Implants During The Stance Phase Of Gait, Timothy S. Jain Mar 2024

Finite Element Analysis Of The Bearing Component Of Total Ankle Replacement Implants During The Stance Phase Of Gait, Timothy S. Jain

Master's Theses

Total ankle replacement (TAR) implants are an effective option to restore the range of motion of the ankle joint for arthritic patients. An effective tool for analyzing these implants’ mechanical performance and longevity in-silico is finite element analysis (FEA). ABAQUS FEA was used to statically analyze the von Mises stress and contact pressure on the articulating surface of the bearing component in two newly installed fixed-bearing total ankle replacement implants (the Wright Medical INBONE II and the Exactech Vantage). This bearing component rotates on the talar component to induce primary ankle joint motion of plantarflexion and dorsiflexion. The stress response …


Analysis Of Gait Parameters And Knee Angles In Ultimate Frisbee Players: Implications For Balance And Injury, Ethan Nikcevich Oct 2023

Analysis Of Gait Parameters And Knee Angles In Ultimate Frisbee Players: Implications For Balance And Injury, Ethan Nikcevich

Master's Theses

Biomechanics research investigating gait and balance of ultimate frisbee players is an unexplored topic. Ultimate requires a wide range of motions that could improve balance and is also a sport prone to frequent injury. This study explores the impact of playing ultimate on gait parameters associated with balance and knee angles associated with joint injury. Gait trials were conducted on 8 ultimate players and 8 control participants between the ages of 18 and 23 to obtain total double support time, stance phase time, single support time, load response time, abduction-adduction (AA) angles, internal-external (IE) rotation angles, and flexion angles of …


A Proof Of Concept For Detection Of Palato-Lingual Contact Without Intraoral Electrodes In A Human Participant, Amitava Biswas May 2023

A Proof Of Concept For Detection Of Palato-Lingual Contact Without Intraoral Electrodes In A Human Participant, Amitava Biswas

Master's Theses

The author of this thesis conceived and investigated an unexpected electrical signal that may not be noticed during regular electroglottography (EGG) when electrodes are conventionally placed on the anterior surface of the throat. It appears that there is a measurable electrical signal from the EGG equipment when electrodes are placed over the frontal cheek (belly of zygomatic muscle), and the tongue is elevated to contact the hard palate, or the tongue is lowered to break the contact. Therefore, this phenomenon is designated as unconventional electroglottography (UEGG, Dr. Steven Cloud, private communication, July 17, 2022).

Two distinctive patterns of waveforms were …


Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones Nov 2022

Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones

Master's Theses

This paper describes the design, manufacturing, and testing of a novel controllable hypoxic incubator with fully functional oxygen gas control and temperature control in a humid environment. On the current market, a majority of the few hypoxic incubators use pre-mixed gas that does not offer precise control over gas concentration. The objective for this project was to create a chamber that allows the user to set the O2 concentration to varying set points of % O2 while maintaining the chamber at a constant body temperature, CO2 level, humidity, and sterility. To start the project, multiple concepts were developed for the …


Medial And Lateral Tibiofemoral Contact Forces For Individuals With High Body Mass Index In Gait And Cycling Training, Reymil Fernandez Dec 2021

Medial And Lateral Tibiofemoral Contact Forces For Individuals With High Body Mass Index In Gait And Cycling Training, Reymil Fernandez

Master's Theses

The prevalence of knee osteoarthritis, a degenerative joint disease characterized by the degradation of articular cartilage, is correlated with the rise in obesity. The rising rates of obesity in children and adults highlight the need for identifying a sustainable physical activity that promotes fitness while mitigating initiation and progression of osteoarthritis. The objective of this study was to determine an effective rehabilitation and lifelong fitness sustainment exercise regimen that minimize risk of osteoarthritis in individuals with high body mass index (BMI). The aim was to examine knee medial and lateral contact forces in gait and cycling training. Gait at self-selected …


Triangular Cosserat Point Element Method For Reducing Soft Tissue Artifact: Validation And Application To Gait, Jake Edward Deschamps, Stephen Klisch Dec 2021

Triangular Cosserat Point Element Method For Reducing Soft Tissue Artifact: Validation And Application To Gait, Jake Edward Deschamps, Stephen Klisch

Master's Theses

Human motion capture technology is a powerful tool for advancing the understanding of human motion biomechanics (Andriacchi and Alexander, 2000). This is most readily accomplished by applying retroreflective markers to a participant’s skin and tracking the position of the markers during motion. Skin and adipose tissue move independently of the underlying bone during motion creating error known as soft tissue artifact (STA), the primary source of error in human motion capture (Leardini et al., 2005).

(Solav et al., 2014) proposed and (Solav et al., 2015) expanded the triangular Cosserat point element (TCPE) method to reduce the effect of STA on …


Design And Implementation Of A Modular Human-Robot Interaction Framework, Michael J. Juri Jun 2021

Design And Implementation Of A Modular Human-Robot Interaction Framework, Michael J. Juri

Master's Theses

With the increasing longevity that accompanies advances in medical technology comes a host of other age-related disabilities. Among these are neuro-degenerative diseases such as Alzheimer's disease, Parkinson's disease, and stroke, which significantly reduce the motor and cognitive ability of affected individuals. As these diseases become more prevalent, there is a need for further research and innovation in the field of motor rehabilitation therapy to accommodate these individuals in a cost-effective manner. In recent years, the implementation of social agents has been proposed to alleviate the burden on in-home human caregivers. Socially assistive robotics (SAR) is a new subfield of research …


The Application Of Post-Hoc Correction Methods For Soft Tissue Artifact And Marker Misplacement In Youth Gait Knee Kinematics, Kaila L. Lawson Jun 2021

The Application Of Post-Hoc Correction Methods For Soft Tissue Artifact And Marker Misplacement In Youth Gait Knee Kinematics, Kaila L. Lawson

Master's Theses

Biomechanics research investigating the knee kinematics of youth participants is very limited. The most accurate method of measuring knee kinematics utilizes invasive procedures such as bone pins. However, various experimental techniques have improved the accuracy of gait kinematic analyses using minimally invasive methods. In this study, gait trials were conducted with two participants between the ages of 11 and 13 to obtain the knee flexion-extension (FE), adduction-abduction (AA) and internal-external (IE) rotation angles of the right knee. The objectives of this study were to (1) conduct pilot experiments with youth participants to test whether any adjustments were necessary in the …


Understanding The Effects Of Long-Duration Spaceflight On Fracture Risk In The Human Femur Using Finite Element Analysis, Keyanna Brielle Henderson Dec 2020

Understanding The Effects Of Long-Duration Spaceflight On Fracture Risk In The Human Femur Using Finite Element Analysis, Keyanna Brielle Henderson

Master's Theses

Long-duration spaceflight has been shown to have significant, lasting effects on the bone strength of astronauts and to contribute to age-related complications later in life. The microgravity environment of space causes a decrease in daily mechanical loading, which signals a state of disuse to bone cells. This affects the bone remodeling process, which is responsible for maintaining bone mass, causing an increase in damage and a decrease in density. This leads to bone fragility and decreases overall strength, posing a risk for fracture. However, there is little information pertaining to the timeline of bone loss and subsequent fracture risk.

This …


Use Of Body Composition Imaging To Calculate 3-D Inertial Parameters For Inverse Dynamic Analysis Of Youth Pitching Arm Kinetics, Dalton James Jennings Mar 2020

Use Of Body Composition Imaging To Calculate 3-D Inertial Parameters For Inverse Dynamic Analysis Of Youth Pitching Arm Kinetics, Dalton James Jennings

Master's Theses

The objectives of this study were to 1) calculate participant-specific segment inertial parameters using dual energy X-ray absorptiometry (DXA) data (referred to as full DXA-driven parameters) and compare the pitching arm kinetic predictions using full DXA-driven inverse dynamics vs scaled, DXA mass-driven (using DXA masses but scaled centers of mass and radii of gyration), and DXA scaled inverse dynamics(ID) (using the full DXA-driven inertial parameters averaged across all participants), 2) examine associations between full DXA-driven kinetics and body mass index (BMI) and 3) examine associations between full DXA-driven kinetics and segment mass index (SMI). Eighteen 10- to 11- year-olds pitched …


A Novel Fiber Jamming Theory And Experimental Verification, Jared Richard Chafetz Oct 2019

A Novel Fiber Jamming Theory And Experimental Verification, Jared Richard Chafetz

Master's Theses

This thesis developed a novel theory of fiber jamming and experimentally verified it. The theory relates the performance, which is the ratio between the stiff and soft states of a fiber jamming chamber, to three relative design parameters: the ratio of the wall thickness to the membrane inner diameter, the ratio of the fiber diameter to membrane inner diameter, and the number of fibers. These three parameters, when held constant across different chamber sizes, hold the performance constant. To test the theory, three different types of fiber jamming chambers were built in three different sizes. Each chamber was set up …


Hip And Knee Biomechanics For Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov Dec 2018

Hip And Knee Biomechanics For Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov

Master's Theses

Transtibial amputees are at increased risk of contralateral hip and knee joint osteoarthritis, likely due to abnormal biomechanics. Biomechanical challenges exist for transtibial amputees in gait and cycling; particularly, asymmetry in ground/pedal reaction forces and joint kinetics is well documented and state-of-the-art passive and powered prostheses do not fully restore natural biomechanics. Elliptical training has not been studied as a potential exercise for rehabilitation, nor have any studies been published that compare joint kinematics and kinetics and ground/pedal reaction forces for the same group of transtibial amputees in gait, cycling, and elliptical training. The hypothesis was that hip and knee …


Subject-Specific Finite Element Predictions Of Knee Cartilage Pressure And Investigation Of Cartilage Material Models, Michael G. Rumery Sep 2018

Subject-Specific Finite Element Predictions Of Knee Cartilage Pressure And Investigation Of Cartilage Material Models, Michael G. Rumery

Master's Theses

An estimated 27 million Americans suffer from osteoarthritis (OA). Symptomatic OA is often treated with total knee replacement, a procedure which is expected to increase in number by 673% from 2005 to 2030, and costs to perform total knee replacement surgeries exceeded $11 billion in 2005. Subject-specific modeling and finite element (FE) predictions are state-of-the-art computational methods for anatomically accurate predictions of joint tissue loads in surgical-planning and rehabilitation. Knee joint FE models have been used to predict in-vivo joint kinematics, loads, stresses and strains, and joint contact area and pressure. Abnormal cartilage contact pressure is considered a risk factor …


Human Knee Fea Model For Transtibial Amputee Tibial Cartilage Pressure In Gait And Cycling, Gregory Lane Jun 2018

Human Knee Fea Model For Transtibial Amputee Tibial Cartilage Pressure In Gait And Cycling, Gregory Lane

Master's Theses

Osteoarthritis (OA) is a debilitating disease affecting roughly 31 million Americans. The incidence of OA is significantly higher for persons who have suffered a transtibial amputation. Abnormal cartilage stress can cause higher OA risk, however it is unknown if there is a connection between exercise type and cartilage stress. To help answer this, a tibiofemoral FEA model was created. Utilizing linear elastic isotropic materials and non-linear springs, the model was validated to experimental cadaveric data. In a previous study, 6 control and 6 amputee subjects underwent gait and cycling experiments. The resultant knee loads were analyzed to find the maximum …


Knee Angles And Axes Crosstalk Correction In Gait, Cycling, And Elliptical Training Exercises, Jordan M. Skaro May 2018

Knee Angles And Axes Crosstalk Correction In Gait, Cycling, And Elliptical Training Exercises, Jordan M. Skaro

Master's Theses

When conducting motion analysis using 3-dimensional motion capture technology, errors in marker placement on the knee results in a widely observed phenomenon known as “crosstalk” [1-18] in calculated knee joint angles (i.e., flexion-extension (FE), adduction-abduction (AA), internal-external rotation (IE)). Principal Component Analysis (PCA) has recently been proposed as a post hoc method to reduce crosstalk errors and operates by minimizing the correlation between the knee angles [1, 2]. However, recent studies that have used PCA have neither considered exercises, such as cycling (C) and elliptical training (E), other than gait (G) nor estimated the corrected knee axes following PCA correction. …


The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco Jun 2016

The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco

Master's Theses

Osteoarthritis (OA) is a degenerative disease of cartilage and bone tissue and the most common form of arthritis, accounting for US$ 10.5 billion in hospital charges in 2006. Obesity (OB) has been linked to increased risk of developing knee OA due to increased knee joint loads and varus-valgus misalignment. Walking is recommended as a weight-loss activity but it may increase risk of knee OA as OB gait increases knee loads. Cycling has been proposed as an alternative weight-loss measure, however, lack of studies comparing normal weight (NW) and OB subjects in cycling and gait hinder identification of exercises that may …


Design And Analysis Of A Lift Assist Walker, Deep P. Shah Mar 2016

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


A Finite Element Analysis Of Tibial Stem Geometry For Total Knee Replacements, Aaron Isidro Bautista Jun 2015

A Finite Element Analysis Of Tibial Stem Geometry For Total Knee Replacements, Aaron Isidro Bautista

Master's Theses

The purpose of this study was to investigate the influence of tibial stem geometry on stress shielding of the tibia for patients with a total knee replacement. Finite element analysis was used to study different tibial stem geometry types, as well as a vast array of different geometric sizes. Both a peg and stem type geometry were analyzed and compared in order to determine what type geometry causes the least amount of stress shielding. A static loading condition with a dynamic loading factor of three was used for the system and the stress responses were analyzed at regions of interest …


Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla Jun 2015

Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla

Master's Theses

Osteoarthritis (OA) is a degenerative condition of articular cartilage that affects more than 25 million people in the US. Joint injuries, like anterior cruciate ligament (ACL) tears, can lead to OA due to a change in articular cartilage loading. Gait analysis combined with knee joint finite element modeling (FEM) has been used to predict the articular cartilage loading. To predict the change of articular cartilage loading during gait due to various ACL injuries, a tibiofemoral FEM was developed from magnetic resonance images (MRIs) of a 33 year male, with no prior history of knee injuries. The FEM was validated for …


Development And Validation Of A Human Knee Joint Finite Element Model For Tissue Stress And Strain Predictions During Exercise, Spencer D. Wangerin Dec 2013

Development And Validation Of A Human Knee Joint Finite Element Model For Tissue Stress And Strain Predictions During Exercise, Spencer D. Wangerin

Master's Theses

Osteoarthritis (OA) is a degenerative condition of cartilage and is the leading cost of disability in the United States. Motion analysis experiments in combination with knee-joint finite element (FE) analysis may be used to identify exercises that maintain knee-joint osteochondral (OC) loading at safe levels for patients at high-risk for knee OA, individuals with modest OC defects, or patients rehabilitating after surgical interventions. Therefore, a detailed total knee-joint FE model was developed by modifying open-source knee-joint geometries in order to predict OC tissue stress and strain during the stance phase of gait. The model was partially validated for predicting the …


Development And Validation Of A Human Hip Joint Finite Element Model For Tissue Stress And Strain Predictions During Gait, Jeffrey D. Pyle Dec 2013

Development And Validation Of A Human Hip Joint Finite Element Model For Tissue Stress And Strain Predictions During Gait, Jeffrey D. Pyle

Master's Theses

Articular cartilage degeneration, called osteoarthritis, in the hip joint is a serious condition that affects millions of individuals yearly, with limited clinical solutions available to prevent or slow progression of damage. Additionally, the effects of high-risk factors (e.g. obesity, soft and hard tissue injuries, abnormal joint alignment, amputations) on the progression of osteoarthritis are not fully understood. Therefore, the objective of this thesis is to generate a finite element model for predicting osteochondral tissue stress and strain in the human hip joint during gait, with a future goal of using this model in clinically relevant studies aimed at prevention, treatment, …


Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino Jun 2013

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino

Master's Theses

Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …


Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel Jun 2012

Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel

Master's Theses

Experimental results show that collagen fibers exhibit stress relaxation under tension and a highly anisotropic distribution. To further develop the earlier model of Stender [1], the collagen constituent was updated to reflect its intrinsic viscoelasticity and anisotropic distribution, and integrated with an existing mixture model with glycosaminoglycans and ground substance matrix. A two-term Prony series expansion of the quasi-linear viscoelastic model was chosen to model the viscoelastic properties of the collagen fibers. Material parameters were determined by using the simplex method to minimize the sum of squared errors between model results and experimental stress relaxation data of tissue in tension. …


Prediction Of Articular Cartilage Remodeling During Dynamic Compression With A Finite Element Model, Kevin Akira Yamauchi Jun 2012

Prediction Of Articular Cartilage Remodeling During Dynamic Compression With A Finite Element Model, Kevin Akira Yamauchi

Master's Theses

First, an in vitro growth experiment was performed to test the hypothesis that applying dynamic unconfined compression during culture produces het- erogeneous remodeling in newborn bovine articular cartilage explants. Het- erogeneous measures of cartilage microstructure were obtained by biochemical assays and quantified polarized light microscopy. Significant differences were measured between the GAG content in the inner and outer portions of the sam- ples stimulated with dynamic unconfined compression. The COL fiber network was found to be more highly aligned in the inner portion of the sample than in the peripheral region.

Next, a poroelastic finite element model with a remodeling …


Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz Aug 2011

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz

Master's Theses

ICSI (intra-cytoplasmic sperm injection) has attracted research interest from both biological and engineering groups. The technology is constantly evolving to perform this procedure with precision and speed. One such development is the contribution of this thesis. We focus on a relatively recent procedure called Ros-Drill© (rotationally oscillating drill), of which the early versions have already been effectively utilized for the mice. In the first part, we present a procedure to automate a critical part of the operation: initiation of the rotational oscillation, Visual feedback is used to track the pipette tip. Predetermined species-specific penetration depth is successfully utilized …