Upper Extremity Mobility Device, Timothy J. Grassi, Jacob R. Miller Jan 2020

Upper Extremity Mobility Device, Timothy J. Grassi, Jacob R. Miller

Williams Honors College, Honors Research Projects

The goal of this project was to evaluate a clinical problem, explore possible solutions, and produce a functioning prototype that would conform to all the established guidelines and requirements. The project focused on developing an upper extremity mobility device for a singular client with limited muscle activity in his arms due to childhood polio. Our design process was governed by an adapted form of the FDA Design Control Process, 21 CFR 820.30 [1]. The outcome of this project was a functioning prototype that utilized the concept of a motorized pulley system remote controlled using a key fob. This research project …


A Novel Approach To Mid-Foot Reconstruction Surgery In Patients With Charcot Arthropathy, Jessi Martin, Deborah Falokun Jan 2020

A Novel Approach To Mid-Foot Reconstruction Surgery In Patients With Charcot Arthropathy, Jessi Martin, Deborah Falokun

Williams Honors College, Honors Research Projects

This honors project details the design and development of an internal orthopedic implant that surgically corrects the midfoot fracture and subsequent arch collapse in patients with Charcot arthropathy. The client of the project is Dr. David Kay, an orthopedic surgeon with the Crystal Clinic in Akron, Ohio. He presented a problem surrounding surgical implants meant to repair Charcot arthropathy. Implants that repair the midfoot fracture failed at a rate of about 60%. A team of senior biomedical engineering students attending the University of Akron developed a goal to design a new surgical implant that would reduce the failure rate of …


All-Wheel-Ukraine, Sofiya Rakovska, Hannah Mcculloch, Andrey Garasimchuk, Ahmad Alsaihati Jan 2020

All-Wheel-Ukraine, Sofiya Rakovska, Hannah Mcculloch, Andrey Garasimchuk, Ahmad Alsaihati

Williams Honors College, Honors Research Projects

We are working with a non-profit organization in Ukraine that provides wheelchairs/strollers to families of disables children who cannot afford them. Their current preferred solution is a baby stroller. The organization asked us to create a wheelchair that is cost efficient, light and collapsible to be used for children ages up to thirteen years old. We will be creating an alpha prototype wheelchair by modifying a basic wheelchair that we purchased. This modifications include adding a headrest that is adjustable and provides a sufficient support for children within the age group given to us and diverse levels of disabilities. We …


Lower Extremity Exoskeleton, Kelly Haslett, Jacalyn Everhart Jan 2020

Lower Extremity Exoskeleton, Kelly Haslett, Jacalyn Everhart

Williams Honors College, Honors Research Projects

Develop a lower extremity device that provides assistance, support, and gait correction for children with cerebral palsy who display crouch gait as a symptom. The device will be designed for children ages 7-12. The device will be adjustable to accommodate varying levels of gait irregularity, weakness and human growth. The device would assist walking and stair climbing by providing bilateral support at hips, knees and ankle joints. The device will be designed for ease of donning and doffing. Battery, drive and control electronics will be designed to reside in a minimalistic backpack (outside the scope of this project).


Artificial Reverse Shoulder Arthroplasty Joint Project, Michael Rosen, Bailei Hoyng Jan 2020

Artificial Reverse Shoulder Arthroplasty Joint Project, Michael Rosen, Bailei Hoyng

Williams Honors College, Honors Research Projects

This proposed project will be developing an artificial reverse shoulder arthroplasty joint that focuses on improvements to the Zimmer Biomet Comprehensive Reverse System by freating a unique feature, or features, to the humeral component that focuses on the prevention of dislocation by not limiting the range of motion of men from ages 45 to 65 years.

The development of the this project will utilize the Food and Drug Administration (FDA) medical device design process. This project will involve a total of four Biomedical Engineering students from the University of Akron. Two students, Michael and Bailei, are in the Honors college …


Enhancement Of The Syncardia Total Artificial Heart For Pediatric Use, Margaret Clark, Madison Marks Jan 2020

Enhancement Of The Syncardia Total Artificial Heart For Pediatric Use, Margaret Clark, Madison Marks

Williams Honors College, Honors Research Projects

Pediatric patients with disorders and diseases of the heart have limited options with regards to implantable devices. Many of these implants are ventricular assist devices, which is not always suitable for a patient. Total artificial hearts (TAHs) have supported many adult patients until transplantation, and we believe that they could do the same for pediatric patients. SynCardia has the only Food and Drug Administration (FDA) approved TAH devices. Since SynCardia is the only company with FDA approved TAHs, we decided to modify the design of the SynCardia TAH for use in pediatric patients without compromising the function of the current …


Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi Jan 2020

Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi

Electronic Theses and Dissertations

Transcatheter mitral valve replacement (TMVR) is being developed to become a substitute therapy for surgery in prohibitive or high surgical risk patients to treat severe mitral regurgitation. A limited number of TMVR systems are under clinical evaluation. However, transcatheter mitral valve (TMV) long-term durability and hemodynamic performance is not known. TMV durability and hemodynamics must match with that of surgical bioprostheses for potential commercialization of TMVR. Experimental and computational approaches were used to find the leaflets’ three-dimensional anisotropic mechanical properties in a transcatheter Edwards SAPIEN 3 valve and a surgical Carpentier-Edwards PERIMOUNT Magna mitral valve and finite element (FE) simulations …


Mems Biosensor For Water-Immersed Application, Kun-Lin Lee Jan 2020

Mems Biosensor For Water-Immersed Application, Kun-Lin Lee

Dissertations and Theses

Although many air-based sensing mechanisms exist, not all of them can be applied in the water-based environment. In order to obtain a cell-based biosensor, the sensing method needs to be reliable and repeatable in a liquid environment. Therefore, this study is focused on transforming existing air-based sensors to water-immersed applications. This study includes two types of sensors.

First, commercial quartz resonators are used to investigate live-cell activity in water-based toxic solutions. I perform toxicity tests using quartz crystal microbalance (QCM). The QCM used in the study has a resonant frequency of 10 MHz and consists of an AT-cut quartz crystal …


Comparative Performance Of The Nanoscan And The Classic Smps In Determining N95 Filtering Facepiece Efficiency Against Nanoparticles, Clothilde Brochot, Fariborz Haghighat, Ali Bahloul Jan 2020

Comparative Performance Of The Nanoscan And The Classic Smps In Determining N95 Filtering Facepiece Efficiency Against Nanoparticles, Clothilde Brochot, Fariborz Haghighat, Ali Bahloul

Études primaires

Nanoparticles are defined as particles with at least one dimension in the range of 1–100 nm. Due to the special properties of nanoparticles, they are used in many workplaces, thus leading to occupational exposure. Filtering facepieces (FFPs) are generally used in these workplaces to reduce the exposure. Many studies have measured FFP efficiency in laboratories using a scanning mobility particle sizer (SMPS). The aim of this study was to determine whether a NanoScan could be used to measure FFP efficiency against nanoparticles in workplaces for one type of N95 FFP. The results showed that the NanoScan gave maximum penetration and …


Binder Saturation, Layer Thickness, Drying Time And Their Effects On Dimensional Tolerance And Density Of Cobalt Chrome - Tricalcium Phosphate Biocomposite, John Ruprecht Jan 2020

Binder Saturation, Layer Thickness, Drying Time And Their Effects On Dimensional Tolerance And Density Of Cobalt Chrome - Tricalcium Phosphate Biocomposite, John Ruprecht

All Graduate Theses, Dissertations, and Other Capstone Projects

Traditional metals such as stainless steel, titanium and cobalt chrome are used in biomedical applications (implants, scaffolds, etc.) but suffer from issues such as osseointegration and compatibility with existing bone. One way to improve traditional biomaterials is to incorporate ceramics with these metals so that their mechanical properties can be similar to cortical bones. Tricalcium phosphate is such a ceramic with properties such that it can be used in the human body. This research explores the use of the Binder Jetting based additive manufacturing process to create a novel biocomposite made of cobalt chrome and tricalcium phosphate. Experiments were conducted …


On-Demand Electrically Induced Decomposition Of Thin-Film Nitrocellulose Membranes For Wearable Or Implantable Biosensor Systems, Benjamin M. Horstmann Jan 2020

On-Demand Electrically Induced Decomposition Of Thin-Film Nitrocellulose Membranes For Wearable Or Implantable Biosensor Systems, Benjamin M. Horstmann

Theses and Dissertations

Implantable or subcutaneous biosensors used for continuous health monitoring have a limited functional lifetime requiring frequent replacement and therefore may be highly discomforting to the patient and become costly. One possible solution to this problem is use of biosensor arrays where each individual reserve sensor can be activated on-demand when the previous one becomes inoperative due to biofouling or enzyme degradation. Each reserve biosensor in the array is housed in an individual Polydimethylsiloxane (PDMS) well and is protected from exposure to bodily fluids such as interstitial fluid ( ISF) by a thin-film nitrocellulose membrane. Controlled activation is achieved by decomposing …


Development Of A Torque-Based Device For The Quantification Of Arm Rigidity In Patients With Parkinson’S Disease, Georgina O. Miller Jan 2020

Development Of A Torque-Based Device For The Quantification Of Arm Rigidity In Patients With Parkinson’S Disease, Georgina O. Miller

Theses and Dissertations

Parkinsonian rigidity is caused by the inability of the muscles to relax and extend properly, due to reduced dopamine levels and often begins on one side of the body before spreading contralaterally. The current standard for determining joint rigidity in a clinical setting is a test completed by the clinician based on the feel of the relaxed wrist and elbow joints as they are passively flexed and extended and a series of ordinal rating scales, the Movement Disorder Society’s – Unified Parkinson’s Disease Rating Scale (MDS-UPDRS), Hoehn and Yahr Scale (H&Y), and Parkinson’s Disease Questionnaire-39 (PDQ-39). These methods are used …


Blood Glucose Predictor, Jessica Patterson Dec 2019

Blood Glucose Predictor, Jessica Patterson

Electrical Engineering

For my senior project, I perform data analysis using statistical methods to determine body metrics that correlate with blood glucose levels. Working with Dr. Tina Smilkstein, I take repeat measurements from 6 different volunteers to establish trends in bodily metric data. The data taken includes weight, body fat, pulse rate, VO2, blood glucose, blood pressure, hours slept, and quality of sleep. Using these values, I use the program MiniTab to view results.

A few examples of correlations with blood glucose found in this project are:

  • Systolic blood pressure for females had a regression line of 124.0 -0.3366*Blood Pressure. This indicates …


Quantitative Analysis Techniques For Assessing Organelle Organization And Dynamics In Individual Cells, Isaac Vargas Dec 2019

Quantitative Analysis Techniques For Assessing Organelle Organization And Dynamics In Individual Cells, Isaac Vargas

Graduate Theses and Dissertations

In biomedical optics and microscopy, the organization and morphology of organelles have been widely studied. In spite of novel imaging techniques, there is still a lack of quantitative tools to easily measure cellular characteristics from image data. Previous studies have explored multiple approaches to assess organelle organization and alignment, resulting in complicated and extensive algorithms that are both subject to multiple steps of image processing and influenced by non-cellular artifacts. In this thesis, a technique called the Modified Blanket Method (MBM) is introduced to quantify organelle organization through measurements of fractal dimension (FD) on a pixel-by-pixel basis. With the use …


The Design And Development Of A Device To Assist In Boosting Patients, Taylor A. Rieckhoff Dec 2019

The Design And Development Of A Device To Assist In Boosting Patients, Taylor A. Rieckhoff

Masters Theses

A common task a nurse is required to perform is called boosting patients. Boosting a patient is defined as lifting or sliding a patient back up in the bed after having slid down (Mannheim, Zieve, & Conaway, 2017). The current method for boosting patients involves a minimum of two personnel and an 11-step process. The 11-step process requires the person to manually lift and pull the patient using an existing half sheet on the bed (Mannheim, Zieve, & Conaway, 2017). Patients who cannot move or support themselves are moved every two to six hours or upon request (Bihn, Rieckhoff, Burkman, …


Single-Cell Impedance Spectroscopy, David Paul Lange Dec 2019

Single-Cell Impedance Spectroscopy, David Paul Lange

Master's Theses

Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Biofluidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS system, an impedance spectroscopy bioMEMS chip was fabricated in the Cal Poly Microfabcrication lab, software was developed to run IS experiments, and studies were run to validate the system. To explore IS optimization, Maxwell’s mixture theorem and the Schwartz-Christoffel transform were used to calculate an analytic impedance solution to the co-planar electrode system,a novel volume fraction to account for …


Fluid Shift And Fluid Resuscitation In Burn Patients With The Use Of Bio-Electrical Impedance Spectroscopy To Monitor Fluid Levels, Temitope D. Obielodan Nov 2019

Fluid Shift And Fluid Resuscitation In Burn Patients With The Use Of Bio-Electrical Impedance Spectroscopy To Monitor Fluid Levels, Temitope D. Obielodan

Honors College Theses

The purpose of this research is to explore the current methods of fluid resuscitation and other possible methods of measuring the body fluid levels of burn patients in order to fully understand the fluid increase patterns in the torso area. This will be done primarily by focusing on the concept of bio-electrical impedance spectroscopy to measure the fluid levels only in the human torso area. Three similar tests were carried out by measuring the resistance values after ingesting 500ml of water. This was repeated until a total of 1500ml of water was ingested. It was found that the resistance in …


A Review Of Materials For Managing Bone Loss In Revision Total Knee Arthroplasty, Romina Shafaghi, Omar Rodriguez, Emil H. Schemitsch, Paul Zalzal, Stephen D. Waldman, Marcello Papini, Mark R. Towler Nov 2019

A Review Of Materials For Managing Bone Loss In Revision Total Knee Arthroplasty, Romina Shafaghi, Omar Rodriguez, Emil H. Schemitsch, Paul Zalzal, Stephen D. Waldman, Marcello Papini, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

In 2014–2015, 61,421 total knee arthroplasties (TKAs) were performed in Canada; an increase of about 20% over 2000–2001. Revision total knee arthroplasties (rTKAs) accounted for 6.8% of TKAs performed between 2014 and 2015, and this is estimated to grow another 12% by 2025. rTKAs are typically more complicated than primary TKAs due to the significant loss of femoral and tibial bone stock. The escalating demand and limitations associated with total knee arthroplasty and their revision drives the development of novel treatments. A variety of materials have been utilized to facilitate regeneration of healthy bone around the site of a knee …


The Effect Of Tantalum Incorporation On The Physical And Chemical Properties Of Ternary Silicon–Calcium–Phosphorous Mesoporous Bioactive Glasses, Andrew Mendonca, Md Saidur Rahman, Adel Alhalawani, Omar Rodriguez, Reid C. Gallant, Heyu Ni, Owen M. Clarkin, Mark R. Towler Oct 2019

The Effect Of Tantalum Incorporation On The Physical And Chemical Properties Of Ternary Silicon–Calcium–Phosphorous Mesoporous Bioactive Glasses, Andrew Mendonca, Md Saidur Rahman, Adel Alhalawani, Omar Rodriguez, Reid C. Gallant, Heyu Ni, Owen M. Clarkin, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Synthesis and characterization of the first mesoporous bioactive glasses (MBGs) containing tantalum are reported here, along with their potential application as hemostats. Silica MBGs were synthesized using with the molar composition of (80-x)% Si, 15% Ca, 5% P, and x% Ta. It was found that incorporation of >1 mol % Ta into the MBGs changes their physical and chemical properties. Increasing Ta content from 0 to 10 mol % causes a decrease in the surface area and pore volume of ~20 and ~35%, respectively. This is due to the increase in nonbridging oxygens and mismatch of thermal expansion coefficient which …


Paper-Based Flexible Electrode Using Chemically-Modified Graphene And Functionalized Multiwalled Carbon Nanotube Composites For Electrophysiological Signal Sensing, Md Faruk Hossain, Jae Sang Heo, John Nelson, Insoo Kim Oct 2019

Paper-Based Flexible Electrode Using Chemically-Modified Graphene And Functionalized Multiwalled Carbon Nanotube Composites For Electrophysiological Signal Sensing, Md Faruk Hossain, Jae Sang Heo, John Nelson, Insoo Kim

Bioelectrics Publications

Flexible paper-based physiological sensor electrodes were developed using chemically-modified graphene (CG) and carboxylic-functionalized multiwalled carbon nanotube composites (f@MWCNTs). A solvothermal process with additional treatment was conducted to synthesize CG and f@MWCNTs to make CG-f@MWCNT composites. The composite was sonicated in an appropriate solvent to make a uniform suspension, and then it was drop cast on a nylon membrane in a vacuum filter. A number of batches (0%~35% f@MWCNTs) were prepared to investigate the performance of the physical characteristics. The 25% f@MWCNT-loaded composite showed the best adhesion on the paper substrate. The surface topography and chemical bonding of the proposed CG-f@MWCNT …


Measurement Of Adhesion Of Sternal Wires To A Novel Bioactive Glass-Based Adhesive, Varinder Pal Singh Sidhu, Mark R. Towler, Marcello Papini Sep 2019

Measurement Of Adhesion Of Sternal Wires To A Novel Bioactive Glass-Based Adhesive, Varinder Pal Singh Sidhu, Mark R. Towler, Marcello Papini

Chemical and Biochemical Engineering Faculty Research & Creative Works

Stainless steel wires are the standard method for sternal closure because of their strength and rigidity, the simplicity of the process, and the short healing time that results from their application. Despite this, problems still exist with sternal stability due to micromotion between the two halves of the dissected and wired sternum. Recently, a novel glass-based adhesive was developed which, in cadaveric trials and in conjunction with wiring, was shown to restrict this micromotion. However, in order to avoid complications during resternotomy, the adhesive should adhere only to the bone and not the sternal wire. In this study, sternal wires …


Bioactive Glass Fiber Fabrication Via A Combination Of Sol-Gel Process With Electro-Spinning Technique, Malvika Nagrath, Adel Alhalawani, Alireza Rahimnejad Yazdi, Mark R. Towler Aug 2019

Bioactive Glass Fiber Fabrication Via A Combination Of Sol-Gel Process With Electro-Spinning Technique, Malvika Nagrath, Adel Alhalawani, Alireza Rahimnejad Yazdi, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

No abstract provided.


Development Of A Statistical Shape-Function Model Of The Implanted Knee For Real-Time Prediction Of Joint Mechanics, Kalin Gibbons Aug 2019

Development Of A Statistical Shape-Function Model Of The Implanted Knee For Real-Time Prediction Of Joint Mechanics, Kalin Gibbons

Boise State University Theses and Dissertations

Outcomes of total knee arthroplasty (TKA) are dependent on surgical technique, patient variability, and implant design. Non-optimal design or alignment choices may result in undesirable contact mechanics and joint kinematics, including poor joint alignment, instability, and reduced range of motion. Implant design and surgical alignment are modifiable factors with potential to improve patient outcomes, and there is a need for robust implant designs that can accommodate patient variability. Our objective was to develop a statistical shape-function model (SFM) of a posterior stabilized implant knee to instantaneously predict output mechanics in an efficient manner. Finite element methods were combined with Latin …


Modification And Optimization Of Conducting Polymer-Modified, Redox-Magnetohydrodynamics (R-Mhd) Pumping For Enhanced And Sustained Microfluidics Applications, Md Foysal Zahid Khan Aug 2019

Modification And Optimization Of Conducting Polymer-Modified, Redox-Magnetohydrodynamics (R-Mhd) Pumping For Enhanced And Sustained Microfluidics Applications, Md Foysal Zahid Khan

Graduate Theses and Dissertations

In this work, a novel microfluidic pumping approach, redox-magnetohydrodynamics (R-MHD) has improved by materials and device optimization to use in lab-on-a-chip applications. In R-MHD, magnetic flux (B) and ionic current density (j) interacts to generate body force (FB) in between active electrodes, according to the equation FB = j×B. This unique fluid pumping approach is scalable, tunable, generates flat flow profile, and does not require any channels or valves. Pumping performance, such as speed scales with the ionic current density (j) and duration depends on the total charge (Q). The ionic current density (j) results from the conversion of electronic …


Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin Jul 2019

Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin

Honors Projects

A 3D printed hand and arm prosthetic was created from the idea of adding bionic elements while keeping the cost low. It was designed based on existing models, desired functions, and materials available. A tilt sensor keeps the hand level, two motors move the wrist in two different directions, a limit switch signals the fingers to open and close, and another motor helps open and close the fingers. All sensors and motors were built on a circuit board, programmed using an Arduino, and powered by a battery. Other supporting materials include metal brackets, screws, guitar strings, elastic bands, small clamps, …


Impedance-Based Microfluidic Platform For Quantitative Biology, Amin Mansoorifar Jul 2019

Impedance-Based Microfluidic Platform For Quantitative Biology, Amin Mansoorifar

Mechanical Engineering Research Theses and Dissertations

Dielectric properties of biological cells are functions of cellular structure, content, state, and phenotype. Dielectric spectroscopy (DS) is a nondestructive method to characterize dielectric properties by measuring impedance data over a frequency range. This method has been widely used for various applications such as counting, sizing, and monitoring biological cells and particles. Recently, this method has been suggested to be utilized in various stages of the drug discovery process due to its low sample consumption and fast analysis time.

In this thesis, we have developed a lab-on-a-chip device that uses an electro-activated microwells array for capturing, making DS measurements on, …


The Effect Of Radial Head Hemiarthroplasty Stem Fit On Radiocapitellar Contact Mechanics: Is Loose Fit Better Than Rigidly Fixed?, Jakub Szmit, Graham J.W. King, James A. Johnson, G. Daniel G. Langohr Jun 2019

The Effect Of Radial Head Hemiarthroplasty Stem Fit On Radiocapitellar Contact Mechanics: Is Loose Fit Better Than Rigidly Fixed?, Jakub Szmit, Graham J.W. King, James A. Johnson, G. Daniel G. Langohr

Western Research Forum

Background/Methods: Radial head hemiarthroplasty is commonly employed to manage comminuted displaced fractures. With regards to implant fixation, current designs vary with some prostheses aiming to achieve a tight 'fixed' fit, and others utilizing a smooth stem with an over reamed 'loose' fit. The purpose of the present study was to evaluate the effect of radial head hemiarthroplasty stem fit on radiocapitellar contact using a finite element model which simulated both fixed (size-for-size) and loose (1, 2 & 3mm over reamed) stem fits.

Hypothesis: It was hypothesized that a loose stem fit would improve radiocapitellar contact mechanics, with increased contact area …


Neurostimulator With Waveforms Inspired By Nature For Wearable Electro-Acupuncture, Jose Aquiles Parodi Amaya Jun 2019

Neurostimulator With Waveforms Inspired By Nature For Wearable Electro-Acupuncture, Jose Aquiles Parodi Amaya

LSU Doctoral Dissertations

The work presented here has 3 goals: establish the need for novel neurostimulation waveform solutions through a literature review, develop a neurostimulation pulse generator, and verify the operation of the device for neurostimulation applications.

The literature review discusses the importance of stimulation waveforms on the outcomes of neurostimulation, and proposes new directions for neurostimulation research that would help in improving the reproducibility and comparability between studies.

The pulse generator circuit is then described that generates signals inspired by the shape of excitatory or inhibitory post-synaptic potentials (EPSP, IPSP). The circuit analytical equations are presented, and the effects of the circuit …


Advanced Design And Fabrication Of Prosthetic And Medical Devices, Gaffar Gailani, Andy S. Zhang, Yu Wang, Sidi Berri Jun 2019

Advanced Design And Fabrication Of Prosthetic And Medical Devices, Gaffar Gailani, Andy S. Zhang, Yu Wang, Sidi Berri

Publications and Research

The department of Mechanical Engineering and Industrial Design Technology (MEIDT) at City Tech is seeking to strengthening the skills of its students in manufacturing and design to respond to the urgent needs of the manufacturing industry in general and the prosthetic and medical devices (P&MD) industry in particular to high-skilled engineers and technicians and to provide a national model for advanced technology education. Medical Devices will include: (a) Surgical and Medical Instruments; (b) Surgical Appliances and Supplies; and (c) Dental Equipment and Supplies. The educational merit of the project is that it motivates students to do engineering rather than studying …


A Physical And Computational Reverse-Engineering Approach To Determine Dimensional Change And Its Relationship To Oxidation In Retrieved Orthopedic Implants, Josephine Kalshoven Jun 2019

A Physical And Computational Reverse-Engineering Approach To Determine Dimensional Change And Its Relationship To Oxidation In Retrieved Orthopedic Implants, Josephine Kalshoven

ENGS 88 Honors Thesis (AB Students)

Oxidation of the Ultra-High Molecular Weight Polyethylene (UHMWPE) tibial inserts of total knee arthroplasty devices is a major factor underlying multiple modes of failure for these devices, including delamination, wear, and fracture. Previous research has demonstrated that oxidation of UHMWPE is driven by a high concentration of free radicals in the polyethylene. However, even new devices created with undetectable amounts of free radicals are oxidizing in vivo. One theory is that, in the absence of residual free radicals, oxidation is facilitated by absorbed species (e.g. lipids, ROS) delivered or exacerbated by contact stress. However, no method exists to comprehensively …