Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Bioelectrical and Neuroengineering (6)
- Electrical and Computer Engineering (6)
- Biomechanics and Biotransport (5)
- Mechanical Engineering (5)
- Bioimaging and Biomedical Optics (4)
-
- Biomaterials (4)
- Medicine and Health Sciences (4)
- Nanoscience and Nanotechnology (4)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (3)
- Biomedical (3)
- Life Sciences (3)
- Molecular, Cellular, and Tissue Engineering (3)
- Other Biomedical Engineering and Bioengineering (3)
- Systems and Integrative Engineering (3)
- Biochemistry (2)
- Biochemistry, Biophysics, and Structural Biology (2)
- Chemistry (2)
- Computer Engineering (2)
- Diseases (2)
- Electromagnetics and Photonics (2)
- Hardware Systems (2)
- Materials Chemistry (2)
- Materials Science and Engineering (2)
- Nanomedicine (2)
- Nanotechnology (2)
- Nanotechnology Fabrication (2)
- Physical Sciences and Mathematics (2)
- Keyword
-
- Neuromodulation (3)
- Brain Stimulation (2)
- Acoustic Pressure Calibration (1)
- Alkali and transition metal filters (1)
- Anterior Cruciate Ligament (1)
-
- Arrayed sensor (1)
- Articulators (1)
- Assistive device (1)
- Automation (1)
- Avalanche photodiodes (1)
- BOLD fMRI (1)
- Biaxial (1)
- BioDent (1)
- Bioconjugation (1)
- Bioelectronic medicine (1)
- Bioheat Transfer FEM Modeling (1)
- Biomarkers (1)
- Biosensor (1)
- Blood glucose monitoring (1)
- Cancer (1)
- Cell characteristics (1)
- Cell impedance (1)
- Chemical stimulation (1)
- Compliance calibration (1)
- Compton scattering (1)
- Constitutive model (1)
- Coronary (1)
- Cruciform (1)
- DBS (1)
- DBS Tissue Interface (1)
- Publication Year
- Publication
- Publication Type
- File Type
Articles 1 - 25 of 25
Full-Text Articles in Biomedical Devices and Instrumentation
Visualization And Marker-Less Tracking Of User-Defined Pre-Processed Mri Articulator Data Using Deep Learning, Michael De George
Visualization And Marker-Less Tracking Of User-Defined Pre-Processed Mri Articulator Data Using Deep Learning, Michael De George
Student Theses
This thesis presents a comprehensive framework for the automated tracking and visualization of articulatory movements based on magnetic resonance imaging (MRI) data. A well-known data analysis tool for markerless pose estimation, known as DeepLabCut, is investigated for this purpose. The performance of this tool is enhanced through the design and implementation of a pre-processor. DeepLabCut is a markerless pose estimation toolbox based on deep learning, which overcomes the issue of making manual annotations frame-by-frame. Limitations from manually marking the MRI images are addressed by implementing transfer learning with convolutional neural networks to achieve accurate, user-defined articulator tracking without markers. Current …
Adaptation Of The Biodent For Spherical Microindentation To Determine Elastic Modulus In Small Rodent Bones, Mixame E. Jerome
Adaptation Of The Biodent For Spherical Microindentation To Determine Elastic Modulus In Small Rodent Bones, Mixame E. Jerome
Dissertations and Theses
Mechanical and material properties of bone are essential for understanding both normal skeletal function and the progression of bone-related diseases. Microindentation has become a widely used method for evaluating tissue mechanical properties of bone, as it samples the contributions of microarchitecture and composition. Microindentation using a standard pointed tip inherently introduces both elastic and plastic deformation into the material. In contrast, indentation with a spherical tip can be operated entirely in the elastic range, providing for a non-damaging test that has significant advantages over sharp indentation techniques. Moreover, a key advantage of using spherical indentation lies in its operation under …
Advancing Electrical Stimulation: Full-Head Mri Segmentation For Abnormal Brain Anatomy With Tdcs, Andrew Birnbaum
Advancing Electrical Stimulation: Full-Head Mri Segmentation For Abnormal Brain Anatomy With Tdcs, Andrew Birnbaum
Dissertations and Theses
Evaluating the effectiveness of transcranial direct current stimulation (tDCS) is essential for guiding its integration into therapeutic and performance-enhancement applications. In our laboratory, we investigate the efficacy of tDCS across multiple experimental models, including both animal and human studies. I have contributed significantly to the execution and analysis of these experiments, which include studies in rats and healthy human participants aimed at evaluating whether electrical stimulation of the motor cortex can enhance motor learning. These studies assess improvements in fine motor performance resulting from tDCS. In stroke patients, I contribute to our investigation of tDCS as a rehabilitative intervention, particularly …
Wearable Disposable Elecetrotherapy, Mohamad Fallahrad
Wearable Disposable Elecetrotherapy, Mohamad Fallahrad
Dissertations and Theses
Non-invasive electrotherapies offer promising treatments for a wide range of conditions such as pain, headaches, depression, addiction, cognitive decline, wound healing, and drug delivery. However, patient compliance remains low due to the high initial cost, cumbersomeness and inconvenience of existing technology compared to pharmaceuticals. Current electrotherapy devices are often bulky and require users to connect disposable electrodes, initiate programs, and manage charging cycles, which hinders widespread adoption.
We address these challenges by designing and validating a novel electrotherapy platform that is single-use, disposable, low-cost, and wearable. Activated automatically upon skin contact, the device delivers a preset dose of controlled electrical …
Optimizing Transcranial Focused Ultrasound: Calibration, Neuro Navigation, And Bold Fmri Evidence Of Neuromodulation, Amilcar J. Malave
Optimizing Transcranial Focused Ultrasound: Calibration, Neuro Navigation, And Bold Fmri Evidence Of Neuromodulation, Amilcar J. Malave
Dissertations and Theses
This thesis presents the development, calibration, and initial implementation of transcranial focused ultrasound (tFUS) for neuromodulation in a human study. The primary objectives were to design a system capable of delivering precise and safe ultrasound stimulation to targeted brain regions and to conduct preliminary trials to assess its effects on brain activity. A custom calibration device was developed to ensure accurate measurement of acoustic pressure, addressing challenges such as voltage alterations caused by changes in system impedance. Additionally, a neuro-navigation tool was created to facilitate precise targeting of the right subgenual anterior cingulate cortex (right sgACC), enabling accurate placement of …
Compton Scattering Of Mammographic Soft X-Ray Beams By Alkali And Transition Metal Salt Filters Produce X-Ray Interference Zones That May Have Treatment Potential For Localized Cancer Lesions, Subhendra N. Sarkar, Eric Lobel, Sabina Rakhmatova, Derbie Desir, Somdat Kissoon, Daler Djuraev, Katie Tam
Compton Scattering Of Mammographic Soft X-Ray Beams By Alkali And Transition Metal Salt Filters Produce X-Ray Interference Zones That May Have Treatment Potential For Localized Cancer Lesions, Subhendra N. Sarkar, Eric Lobel, Sabina Rakhmatova, Derbie Desir, Somdat Kissoon, Daler Djuraev, Katie Tam
Publications and Research
In breast x-ray imaging scattered radiation adds 50% of harmful radiation dose from anisotropic Compton scattering mechanism. We have been working with double layered inorganic salt materials that can induce Compton scattering to the incident mammographic x ray beams (in 20-30 kVp range) with adequate isotropy (angular control). Typically metal nitrates and alkali halide salt layers are shown here to cause low energy radiation interference zones with high and low photon intensities and local flux heterogeneity in terms of flux covariance. Spatial variation of low energy photon flux creates concentrated and sparse radiation zones that may be used to induce …
Construction And Performance Optimization Of Bioconjugated Nanosensors For Early Detection Of Breast Cancer And Pro-Inflammatory Diseases, Pooja Gaikwad
Dissertations, Theses, and Capstone Projects
In recent years, nanosensors have emerged as a tool with strong potential in medical diagnostics. Single-walled carbon nanotube (SWCNT) based optical nanosensors have notably garnered interest due to the unique characteristics of their near-infrared fluorescence emission, including tissue transparency, photostability, and various chiralities with discrete absorption and fluorescence emission bands. Additionally, the optoelectronic properties of SWCNT are sensitive to the surrounding environment, which makes them suitable for in vitro and in vivo biosensing. Single-stranded (ss) DNA-wrapped SWCNTs have been reported as optical nanosensors for cancers and metabolic diseases. Breast cancer and cardiovascular diseases are the most common causes of death …
Use Of Bioheat Modeling To Characterize And Optimize Implantable Medical Devices And Neuromodulation Technologies, Adantchede Louis Zannou
Use Of Bioheat Modeling To Characterize And Optimize Implantable Medical Devices And Neuromodulation Technologies, Adantchede Louis Zannou
Dissertations and Theses
Medical device development includes prototyping, benchtop characterization, preclinical studies, and clinical trials. Understanding the limitations and potential adverse effects of medical devices prior to their administration in humans is a crucial first step. Optimizing medical devices is essential to employing technology and improving patients care. Computational modeling is widely adopted as a powerful tool to predict stimulation/recording parameter optimization, rapid electrode/device prototyping, investigating novel mechanism of action, and testing working principles of any medical devices. Many implantable neuromodulation technologies including Spinal Cord Stimulation (SCS), which provide substantial therapeutic benefit for patient population with lower back pain, produces heat via the …
Review Of Emerging Approaches Utilizing Alternative Physiological Human Body Fluids In Non- Or Minimally Invasive Glucose Monitoring, Sunghoon Jang, Yu Wang, Andre Jang
Review Of Emerging Approaches Utilizing Alternative Physiological Human Body Fluids In Non- Or Minimally Invasive Glucose Monitoring, Sunghoon Jang, Yu Wang, Andre Jang
Publications and Research
Diabetes can cause various acute as well as long-term complications in patients, with blood sugar levels of over 600 mg/dL, such as blindness, kidney disease, nervous & circulatory system disease, limb amputations, stroke, and cardiovascular disease (CVD). Frequent and regular blood glucose monitoring by diabetics and physicians is an essential step in the management of diabetes. Over the last five decades, there have been numerous attempts to develop viable painless non- or minimally invasive blood glucose monitoring techniques to replace all existing invasive methods, such as home blood glucose monitoring, which usually require drawing a blood sample by piercing the …
Impact Of Percutaneous Transluminal Intervention On Vascular Hypoxia And The Role Of Micro-Calcifications On Atherosclerotic Plaque Rupture, Andrea Corti
Dissertations and Theses
Atherosclerotic disease is initiated by cholesterol build-up beneath the endothelium, which evolves into a fibroatheroma, a lipid-rich plaque covered by a fibrous cap. Many of these plaques are considered as vulnerable, as they grow to occlude the luminal section of the artery (chronically stenotic) or become mechanically unstable with a higher chance of rupturing (rupture-prone). On one hand, chronically stenotic vulnerable plaques are symptomatic lesions that are often treated with Percutaneous Transluminal Intervention (PTI). Unfortunately, approximately 10% of PTI procedures are followed by severe Neointima Hyperplasia (NH), which causes a new occlusion and failure of the implant. A significant precursor …
Low-Intensity Ultrasonic Neuromodulation Of The Rat Hippocampus, Duc Nguyen
Low-Intensity Ultrasonic Neuromodulation Of The Rat Hippocampus, Duc Nguyen
Dissertations and Theses
Techniques to non-invasively modulate brain activity are important for mapping human brain circuits, and also for the treatment of a host of neurological and psychiatric disorders marked by aberrant brain activity. Though a wide range of techniques for non-invasive neuromodulation have been proposed, the conventional approaches suffer from significant limitations. Most notably, focal stimulation of deep brain regions is presently only possible with invasive optogenetic and chemogenetic approaches that require craniotomies and genetic access to the brain.
Transcranial focused ultrasound stimulation (tFUS) possesses many of the characteristics desirable from a neuromodulation approach: non-invasiveness, a spatial resolution in the order of …
Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand
Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand
Dissertations and Theses
Localized chemical delivery plays an essential role in the fundamental information transfers within biological systems. Thus, the ability to mimic the natural chemical signal modulation would provide significant contributions to understand the functional signaling pathway of biological cells and develop new prosthetic devices for neurological disorders. In this paper, we demonstrate a light-controlled hydrogel platform that can be used for localized chemical delivery in a high spatial resolution. By utilizing the photothermal behavior of graphene-hydrogel composites confined within micron-sized fluidic channels, patterned light illumination creates the parallel and independent actuation of chemical release in a group of fluidic ports. The …
Development Of A Biaxial Testing System For Research Of Soft Tissue Biomechanics Using Laboratory Models, Tariq Shameen
Development Of A Biaxial Testing System For Research Of Soft Tissue Biomechanics Using Laboratory Models, Tariq Shameen
Dissertations and Theses
The rupture of the cap tissue layer of a fibroatheroma in human coronary vessels is considered the key event leading to the formation of a thrombus and myocardial infarction, resulting in more than half a million deaths in the US every year. In this study, we are interested in investigating the biomechanics of different elastomer materials that can be used as laboratory models to replicate coronary arteries’ ultimate tensile stress (0.2 - 2.08 MPa). To this end, we developed a biomechanical testing system that allows us to characterize the material properties of small samples with high accuracy and precision. We …
Improve The Prototype Of Low-Cost Near-Infrared Diffuse Optical Imaging System, Chen Xu, Mohammed Z. Shakil
Improve The Prototype Of Low-Cost Near-Infrared Diffuse Optical Imaging System, Chen Xu, Mohammed Z. Shakil
Publications and Research
Diffuse Optical Tomography (DOT) and Optical Spectroscopy using near-infrared (NIR) diffused light has demonstrated great potential for the initial diagnosis of tumors and in the assessment of tumor vasculature response to neoadjuvant chemotherapy. The aims of this project are 1) to test the different types of LEDs in the near-infrared range, and design the driving circuit, and test the modulation of LEDs at different frequencies; 2) to test the APDs as a detector, and build the receiver system and compare efficiency with pre-built systems. In this project, we are focusing on creating a low-cost infrared transmission system for tumor and …
Mems Biosensor For Water-Immersed Application, Kun-Lin Lee
Mems Biosensor For Water-Immersed Application, Kun-Lin Lee
Dissertations and Theses
Although many air-based sensing mechanisms exist, not all of them can be applied in the water-based environment. In order to obtain a cell-based biosensor, the sensing method needs to be reliable and repeatable in a liquid environment. Therefore, this study is focused on transforming existing air-based sensors to water-immersed applications. This study includes two types of sensors.
First, commercial quartz resonators are used to investigate live-cell activity in water-based toxic solutions. I perform toxicity tests using quartz crystal microbalance (QCM). The QCM used in the study has a resonant frequency of 10 MHz and consists of an AT-cut quartz crystal …
Advanced Design And Fabrication Of Prosthetic And Medical Devices, Gaffar Gailani, Andy S. Zhang, Yu Wang, Sidi Berri
Advanced Design And Fabrication Of Prosthetic And Medical Devices, Gaffar Gailani, Andy S. Zhang, Yu Wang, Sidi Berri
Publications and Research
The department of Mechanical Engineering and Industrial Design Technology (MEIDT) at City Tech is seeking to strengthening the skills of its students in manufacturing and design to respond to the urgent needs of the manufacturing industry in general and the prosthetic and medical devices (P&MD) industry in particular to high-skilled engineers and technicians and to provide a national model for advanced technology education. Medical Devices will include: (a) Surgical and Medical Instruments; (b) Surgical Appliances and Supplies; and (c) Dental Equipment and Supplies. The educational merit of the project is that it motivates students to do engineering rather than studying …
The Modeling, Design, Fabrication, And Application Of Biosensor Based On Electric Cell-Substrate Impedance Sensing (Ecis) Technique In Environmental Monitoring, Xudong Zhang, William Wang, Sunghoon Jang
The Modeling, Design, Fabrication, And Application Of Biosensor Based On Electric Cell-Substrate Impedance Sensing (Ecis) Technique In Environmental Monitoring, Xudong Zhang, William Wang, Sunghoon Jang
Publications and Research
In this research, the modeling, design, fabrication, and application of ECIS sensors in environmental monitoringare studied. The ECIS sensors are able to qualify the water toxicity through measuring the cell impedance. A novel mathematical model is proposed to analyze the distribution of electric potential and current of ECIS. This mathematical model is validated by experimental data and can be used to optimize the dimension of ECIS electrodes in order to satisfy environmental monitors. The detection sensitivity of ECIS sensors is analyzed by the mathematical model and experimental data. The simulated and experimental results show that ECIS sensors with smaller radius …
The Application Of Electric Cell-Substrate Impedance Sensing (Ecis) Biosensors, Xudong Zhang, Sunghoon Jang
The Application Of Electric Cell-Substrate Impedance Sensing (Ecis) Biosensors, Xudong Zhang, Sunghoon Jang
Publications and Research
Electric cell-substrate impedance sensing (ECIS) is a label-free and non-invasive technique for analyzing the activities and morphologies of cells. The ECIS sensors are able to measure the impedance spectroscopy of cells attaching on the sensor substrates. The cell activities and morphologies influence the measure impedance directly. Traditional toxicity analysis has complicated processes compared to biosensor-based analysis. In this study, the toxicity analysis was performed with biosensor based on ECIS technique. The experimental results show that the ECIS sensor is able to quickly distinguish the toxic and non-toxic substance.
Impoved Hardware Design Of Iot Prosthetic Device, Yu Wang, Warren Hunter, Xiaolin Chen, Housney Ahmed, Haneefah Safo
Impoved Hardware Design Of Iot Prosthetic Device, Yu Wang, Warren Hunter, Xiaolin Chen, Housney Ahmed, Haneefah Safo
Publications and Research
Our previous IoT based prosthetic arm prototype used servo motors to control finger movement through an Arduino Mega, which is connected to the muscle, pulse, and temperature sensors. The Arduino Mega was also connected to a Raspberry Pi 3 model B to transfer data from/to an online web application. One major limitation encountered during testing this prosthetic device was the space occupied by these components, which makes the device bulky. In addition, these servo motors cannot control the movement of the prosthetic device precisely. In this paper, we propose to improve on the existing prosthetic limb prototype by transitioning the …
Collective Chemotaxis Of Retinal Neural Cells From Drosophila Melanogaster In Controlled Microenvironments, Stephanie Zhang
Collective Chemotaxis Of Retinal Neural Cells From Drosophila Melanogaster In Controlled Microenvironments, Stephanie Zhang
Dissertations and Theses
More than 172 million people are influenced by a retinal disorder that stems from either age-related or developmental causes. Of those, 1.5 million people endure a developmental retinal disorder. In the developing retina, neural cells undergo a series of highly complicated differentiation and migration process. A main cause of these diseases is abnormal collective migration of neural progenitors hindering the retinogenesis process. However, our grasp of collective migration and signaling molecules, critical to the developing retina, is incompletely understood. Understanding the molecular mechanisms, such as the fibroblast growth factor pathway, that regulate glial and neuronal migration provides decisive insights in …
Review Of Emerging Approaches In Non- Or Minimally Invasive Glucose Monitoring And Their Application To Physiological Human Body Fluids, Sunghoon Jang, Chen Xu
Review Of Emerging Approaches In Non- Or Minimally Invasive Glucose Monitoring And Their Application To Physiological Human Body Fluids, Sunghoon Jang, Chen Xu
Publications and Research
The frequent blood glucose monitoring by the diabetics and physicians is a very essential step in the management of the diabetes because this devastating disease can lead the patients to blindness, kidney disease, nervous & circulatory system disease, limb amputations, stroke and cardiovascular disease (CVD). There have been numerous attempts to develop viable painless non- or minimally invasive blood glucose monitoring techniques over the last five decades in order to replace all existing methods of home blood glucose monitoring require drawing a blood sample by piercing the skin. This review describes the principles of two main emerging general technologies such …
The Influence Of The Electrode Dimension On The Detection Sensitivity Of Electric Cell–Substrate Impedance Sensing (Ecis) And Its Mathematical Modeling, Xudong Zhang, William Wang, Anis Nurashikin Nordin, Fang Li, Sunghoon Jang, Ioana Voiculescu
The Influence Of The Electrode Dimension On The Detection Sensitivity Of Electric Cell–Substrate Impedance Sensing (Ecis) And Its Mathematical Modeling, Xudong Zhang, William Wang, Anis Nurashikin Nordin, Fang Li, Sunghoon Jang, Ioana Voiculescu
Publications and Research
Detection sensitivity is a crucial criterion in the design and application of ECIS sensors. The influence of sensing electrode dimension on detection sensitivity is investigated in this paper. Eight types of ECIS sensors were fabricated, and their experimental results reveal that smaller-radius working electrodes generate more sensitive impedance shift to cell density change. Also, the smaller radius of working electrodes yield higher impedance values, which improves signal-to-noise ratio. In a range from 1.0 mm to 3.5 mm, the distance between the working and counter electrodes does not affect impedance measurements. However, the distance should be large enough to prevent the …
Design Development And Performance Study Of A Novel Assistive Device For Mobility Of Toddlers And Children With Visual Impairments, Joowon Jun
Dissertations and Theses
Being able to see allows mankind tremendous access to learn about the world, and because so much learning comes visually, children with visual impairments are delayed in developing range of skills: learning own languages, doing activities, socializing with peers, and etc. While children with vision can do virtually all the activities and tasks for granted, children with visual impairment require different types of tools or materials to do same tasks most of time. Amongst all the disadvantages that children with visual impairment have, one of the most critical disadvantageous area that visual impairment brings to toddler is learning to walk. …
Effect Of Temporal Onset Of Mechanical Loading On Tendon To Bone Healing, Determined With A Novel In-Vivo Device, Mark E. Stasiak
Effect Of Temporal Onset Of Mechanical Loading On Tendon To Bone Healing, Determined With A Novel In-Vivo Device, Mark E. Stasiak
Dissertations, Theses, and Capstone Projects
Background: Exposure to tensile loading has been shown to maintain tendon/ligament homeostasis, with the tensile modulus of the tissue increasing in response to greater loading frequency, and even decreasing in the absence of load. However after injury or surgical repair the effect of tensile load is controversial, with many studies implicating mechanical loading with impaired healing. It is currently unknown when the tensile loading imparted during rehabilitation exercise, can be safely reintroduced after surgical tendon repair or ligament reconstruction, and at what time point it can most benefit the remodeling process. To investigate the effect of tensile loading protocols on …
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Publications and Research
Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.
Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.
Results …