Open Access. Powered by Scholars. Published by Universities.®

Biomedical engineering

Discipline
Institution
Publication Year
Publication
Publication Type

Articles 1 - 13 of 13

Full-Text Articles in Biomedical Devices and Instrumentation

Restoreband: An Electromyography Band For Tracking Forearm Muscle Action And Activation In Post-Stroke Adults, Mairin T. Mullen, Melody Nwagwu, Kosuke Nishimura, Benjamin Miramon Jun 2026

Restoreband: An Electromyography Band For Tracking Forearm Muscle Action And Activation In Post-Stroke Adults, Mairin T. Mullen, Melody Nwagwu, Kosuke Nishimura, Benjamin Miramon

Biomedical Engineering

This study involves the design of a non-invasive surface electromyography (EMG) band to estimate hand posture for individuals recovering from stroke and other neuromuscular disorders. The device is meant to measure forearm muscle activation to provide objective recovery data that can supplement traditional rehabilitation. Current EMG systems are often expensive, cumbersome, and difficult to use. The goal of this study is to develop an affordable, accurate, and easy to use solution that improves access to EMG motor monitoring.

The key stakeholders include stroke survivors, clinicians, and the project sponsor, Dr. Espinoza-Wade. This report includes project introduction, background, objectives, and project …


A Solution For Safe Pivot Transfers In A Population With Limited Mobility, Elizabeth A. Mitchell, Sean R. Giamportone May 2026

A Solution For Safe Pivot Transfers In A Population With Limited Mobility, Elizabeth A. Mitchell, Sean R. Giamportone

Honors Theses

Sit-to-stand pivot transfers are one of the most frequently performed movements for

individuals with limited mobility. This movement is very often performed in long-term care

facilities and clinics. Despite the commonality, this transfer poses a significant risk of injury to

both the patient and caregiver; falls, musculoskeletal injuries, and the reduction of independence

can result from issues associated with these transfers. Existing assistive devices, Hoyer lifts and

sliding boards, present limitations with cost, size, storage, and usability; thus, caregivers rely on

the hands-on manual transfer that increases the risk of injury. The goal of our team was to

address these …


Design And Development Of A Stethoscope Attachment For Instant Heart Murmur Detection, Caitlin K. Cherwin, Dillon Desai May 2025

Design And Development Of A Stethoscope Attachment For Instant Heart Murmur Detection, Caitlin K. Cherwin, Dillon Desai

Honors Theses

Heart murmurs are critical indicators of potential cardiovascular conditions yet their detection can often go unnoticed due limitations in equipment and is dependent on clinician experience. Cardiovascular disease remains a leading cause of death worldwide, therefore, early detection of heart murmurs play a crucial role in improving patient outcomes. Many established methods of detection are expensive and often unreliable allowing there to be room for a device which is more cost and result effective. This paper presents the development of a device that attaches onto a regular stethoscope and analyzes auscultatory sounds to diagnose the possibility of a present murmur. …


Towards A Wearable Device For Measuring Impedance Plethysmography Of The Radial Artery, Pritom Chowdhury Apr 2024

Towards A Wearable Device For Measuring Impedance Plethysmography Of The Radial Artery, Pritom Chowdhury

Dartmouth College Master’s Theses

Recent advancements in bioimpedance technology have demonstrated significant promise in the application of cardiac health monitoring. This research explores the design and development of a forearm-based wearable bioimpedance device for non-invasive measurement of heart rate and respiratory rate at an accuracy level comparable to medical-grade monitors. It utilizes a tetrapolar electrode configuration to analyze bioimpedance changes in the radial artery due to blood flow.

An ongoing aspect of this work involves the preliminary development of an embedded framework intended to integrate signal generation, acquisition, and processing within the device to achieve compact and efficient system design, anticipated to contribute to …


Effects Of Noise Electrical Stimulation On Proprioception, Force Control, And Corticomuscular Functional Connectivity, Li-Wei Chou, Shiang-Lin Hou, Hui-Min Lee, Felipe Fregni, Alice Yen, Vincent Chiun-Fan Chen, Shun-Hwa Wei, Chung-Lan Kao May 2023

Effects Of Noise Electrical Stimulation On Proprioception, Force Control, And Corticomuscular Functional Connectivity, Li-Wei Chou, Shiang-Lin Hou, Hui-Min Lee, Felipe Fregni, Alice Yen, Vincent Chiun-Fan Chen, Shun-Hwa Wei, Chung-Lan Kao

Engineering Science Faculty Publications

Sensory afferent inputs play an important role in neuromuscular functions. Subsensory level noise electrical stimulation enhances the sensitivity of peripheral sensory system and improves lower extremity motor function. The current study aimed to investigate the immediate effects of noise electrical stimulation on proprioceptive senses and grip force control, and whether there are associated neural activities in the central nervous system. Fourteen healthy adults participated in 2 experiments on 2 different days. In day 1, participants performed grip force and joint proprioceptive tasks with and without (sham) noise electrical stimulation. In day 2, participants performed grip force steady hold task before …


Advancing Prosthetic Design Using Neural And Mechanical Dynamics, Kacie E. Hanna Jan 2023

Advancing Prosthetic Design Using Neural And Mechanical Dynamics, Kacie E. Hanna

Graduate Theses, Dissertations, and Problem Reports (ETD)

Limb loss poses a significant challenge to mobility and the performance of daily activities. Currently, nearly half of the amputees using powered prosthetics abandon their device due to inadequate limb coordination and movement control abilities. In the healthy system, passive and neural dynamics facilitate the synchronized activation of muscles necessary for coordinated movement. However, in the amputee, the system is disrupted. The goal of this research is to use neural and mechanical dynamics to inform the design of prosthetic devices in order to restore intuitive control and coordinated limb movement.

The first aim of this research is to investigate neural …


Creating Reel Designs: Reflecting On Arthrogryposis Multiplex Congenita In The Community, Iris Layadi Oct 2021

Creating Reel Designs: Reflecting On Arthrogryposis Multiplex Congenita In The Community, Iris Layadi

Purdue Journal of Service-Learning and International Engagement

Because of its extreme rarity, the genetic disease arthrogryposis multiplex congenita (AMC) and the needs of individuals with the diagnosis are often overlooked. AMC refers to the development of nonprogressive contractures in disparate areas of the body and is characterized by decreased flexibility in joints, muscle atrophy, and developmental delays. Colton Darst, a seven-year-old boy from Indianapolis, Indiana, was born with the disorder, and since then, he has undergone numerous surgical interventions and continues to receive orthopedic therapy to reduce his physical limitations. His parents, Michael and Amber Darst, have hopes for him to regain his limbic motion and are …


Modified Stent Design For A Coronary Bifurcation Lesion, Abigail Nowell May 2020

Modified Stent Design For A Coronary Bifurcation Lesion, Abigail Nowell

Biological Sciences Undergraduate Honors Theses

Currently, 18.2 million adults aged 20 and older are diagnosed with Coronary Artery Disease (CAD) (Benjamin et al., 2019). Stenosis is the most common intervention. However, when a patient has a bifurcated artery, treatment becomes more difficult and is often unsuccessful. This project created a new stent and balloon complex that was tested in vitro using a gel phantom artery model. Two separate prototypes have been created and tested so far, with improvements made upon each. Testing is still underway with Prototype 2.


Enhancement Of The Syncardia Total Artificial Heart For Pediatric Use, Margaret Clark, Madison Marks Jan 2020

Enhancement Of The Syncardia Total Artificial Heart For Pediatric Use, Margaret Clark, Madison Marks

Williams Honors College, Honors Research Projects

Pediatric patients with disorders and diseases of the heart have limited options with regards to implantable devices. Many of these implants are ventricular assist devices, which is not always suitable for a patient. Total artificial hearts (TAHs) have supported many adult patients until transplantation, and we believe that they could do the same for pediatric patients. SynCardia has the only Food and Drug Administration (FDA) approved TAH devices. Since SynCardia is the only company with FDA approved TAHs, we decided to modify the design of the SynCardia TAH for use in pediatric patients without compromising the function of the current …


Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin Jul 2019

Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin

Honors Projects

A 3D printed hand and arm prosthetic was created from the idea of adding bionic elements while keeping the cost low. It was designed based on existing models, desired functions, and materials available. A tilt sensor keeps the hand level, two motors move the wrist in two different directions, a limit switch signals the fingers to open and close, and another motor helps open and close the fingers. All sensors and motors were built on a circuit board, programmed using an Arduino, and powered by a battery. Other supporting materials include metal brackets, screws, guitar strings, elastic bands, small clamps, …


Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre May 2019

Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre

Honors Scholar Theses

Abnormal ocular motility is a common manifestation of many underlying pathologies particularly those that are neurological. Dynamics of saccades, when the eye rapidly changes its point of fixation, have been characterized for many neurological disorders including concussions, traumatic brain injuries (TBI), and Parkinson’s disease. However, widespread saccade analysis for diagnostic and research purposes requires the recognition of certain eye movement parameters. Key information such as velocity and duration must be determined from data based on a wide set of patients’ characteristics that may range in eye shapes and iris, hair and skin pigmentation [36]. Previous work on saccade analysis has …


3d Printing In Healthcare, Caleb Branch May 2015

3d Printing In Healthcare, Caleb Branch

The Review: A Journal of Undergraduate Student Research

Technology is everywhere. Technology surrounds every aspect of 21st century life. It is in the cell phones we use, the cars we drive, and even the food we eat. A large portion of modern technology used is taken for granted and overlooked. Despite this, some technology fields continue to grow. Biomedical engineering, specifically 3D printing’s applications to healthcare, has been often overlooked until. Regardless of its status in the mainstream, 3D printing is prosperous in healthcare and its future looks bright. This piece analyzes 3D printing in healthcare. It hones in on the finer details of each specific topic, …


Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory May 2012

Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Adverse events due to medical errors are a leading cause of death in the United States exceeding the mortality rates of motor vehicle accidents, breast cancer and AIDS. Improvements can and should be made to reduce the rates of preventable surgical errors since they account for nearly half of all adverse events within hospitals. Although minimally invasive surgery has proven patient benefits such as reduced postoperative pain and hospital stay, its operative environment imposes substantial physical and cognitive strain on the surgeon increasing the risk of error. In order to mitigate errors and protect patients, a multidisciplinary approach was taken …