Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (11)
- Electrical and Computer Engineering (9)
- Biomedical (7)
- Life Sciences (7)
- Biochemistry, Biophysics, and Structural Biology (4)
-
- Diseases (4)
- Physical Sciences and Mathematics (4)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (3)
- Biochemistry (3)
- Computer Sciences (3)
- Medical Sciences (3)
- Signal Processing (3)
- Anatomy (2)
- Bioimaging and Biomedical Optics (2)
- Biomechanics and Biotransport (2)
- Cardiovascular Diseases (2)
- Cardiovascular System (2)
- Cell and Developmental Biology (2)
- Exercise Science (2)
- Kinesiology (2)
- Molecular Biology (2)
- Theory and Algorithms (2)
- Bacterial Infections and Mycoses (1)
- Biochemical Phenomena, Metabolism, and Nutrition (1)
- Bioelectrical and Neuroengineering (1)
- Biomechanical Engineering (1)
- Biomechanics (1)
- Keyword
-
- Biochemical markers (3)
- Biocompatibility (2)
- Biosensors (2)
- Electrocardiography (2)
- Laser induced graphene (2)
-
- Motion artifacts (2)
- Tactile sensor (2)
- Wearable technology (2)
- AC (1)
- Accelerometers (1)
- Acoustic surface wave devices (1)
- Acute myeloid leukemia (1)
- Adherens junction (1)
- Alanine (1)
- Algorithms (1)
- Arterial pulse measurement (1)
- Arterial pulse signal (1)
- Arterial pulse waveform (1)
- Aspartate (1)
- Auscultation (1)
- Baseline drift (1)
- Basement membrane (1)
- Biochemistry (1)
- Biomarker (1)
- Biomarkers (1)
- Biomedical devices (1)
- Biomedical materials (1)
- Biomimetic material (1)
- Biopsy (1)
- Biosensor (1)
- Publication Year
- Publication
-
- Electrical & Computer Engineering Theses & Dissertations (5)
- Mechanical & Aerospace Engineering Faculty Publications (4)
- Bioelectrics Publications (3)
- Center for Bioelectronics Publications (3)
- Biomedical Engineering Theses & Dissertations (1)
-
- Cardiovascular Research Symposium (1)
- Computational Modeling & Simulation Engineering Theses & Dissertations (1)
- Dental Hygiene Faculty Publications (1)
- Graduate Student Government Association Research Conference (1)
- Human Movement Studies & Special Education Theses & Dissertations (1)
- Mathematics & Statistics Faculty Publications (1)
- Modeling, Simulation and Visualization Student Capstone Conference (1)
- School of Medical Diagnostics & Translational Sciences Publications (1)
- Publication Type
Articles 1 - 24 of 24
Full-Text Articles in Biomedical Devices and Instrumentation
Mxene-Enabled Wearable Biosensors: A Design Framework For Autonomous Biosensing, Jegan Rajendran, Gymama Slaughter
Mxene-Enabled Wearable Biosensors: A Design Framework For Autonomous Biosensing, Jegan Rajendran, Gymama Slaughter
Center for Bioelectronics Publications
MXenes, a rapidly expanding family of two-dimensional transition metal carbides and nitrides, have emerged as leading materials for wearable bioelectronics due to their metallic conductivity, termination-rich surfaces, mechanical compliance, and tunable interlayer structures. However, wearable biosensor performance does not arise from conductivity alone, but from coupled interactions among surface termination chemistry, heterointerface engineering, hierarchical architecture, and device integration under dynamic physiological conditions. This review establishes a predictive structure-interface-device framework linking MXene chemistry to system-level performance across electrochemical, mechanical, gas, optical, and energy-storage modalities. We analyze how termination-controlled adsorption governs charge transfer and selectivity, how heterojunction formation modulates carrier density and …
Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao
Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
Aim: This study investigates the feasibility of using radial and carotid arterial pulse signals to assess cardiovascular (CV) function at rest and during post-exercise recovery in a heart transplant (HTx) patient. Method: Two micro-fabricated tactile sensors were used to simultaneously acquire arterial pulse signals at the radial artery (RA) and carotid artery (CA). Measurements were taken at rest and at multiple time points post-exercise on three subjects: an HTx patient, a percutaneous coronary intervention (PCI; coronary stent) patient and a healthy control. An SDOF-TF-based time-frequency analysis algorithm was applied to extract a comprehensive set of CV parameters, including heart rate …
Novel Percutaneous Repair Of Femoral Pseudoaneurysms Using Perclose Proglide™: A Case Series, Ryan Mancoll, Emily Burnett, Nicholas Bandy, Benjamin Samberg, Thomas Cook, Jacob Hoffman, Christopher Murter, Matthew Rossi, David Dexter, Hosam El Sayed, Animesh Rathore Md
Novel Percutaneous Repair Of Femoral Pseudoaneurysms Using Perclose Proglide™: A Case Series, Ryan Mancoll, Emily Burnett, Nicholas Bandy, Benjamin Samberg, Thomas Cook, Jacob Hoffman, Christopher Murter, Matthew Rossi, David Dexter, Hosam El Sayed, Animesh Rathore Md
Cardiovascular Research Symposium
BACKGROUND - This case series details the novel use of the Perclose ProGlide closure device to successfully repair three separate cases of iatrogenic femoral pseudoaneurysms (PSAs) without attempting other modalities first. Conventional treatment methods of ultrasound-guided compression, duplex-directed thrombin injection (DDTI), or open surgical repair were contraindicated in these patients due to unique anatomy or advanced comorbidities.
METHODS – Details were gathered via a retrospective chart review.
RESULTS - In the first case, a 73-year-old female had an access site PSA off the superficial femoral artery (SFA) with concomitant arteriovenous fistula (AVF) and advanced cardiac disease. The ProGlide device was …
Ac Electric Fields Manipulate And Concentrate Dna Molecules On Electrodes, Akila Wijesinghe, Dharmakeerthi Nawarathna
Ac Electric Fields Manipulate And Concentrate Dna Molecules On Electrodes, Akila Wijesinghe, Dharmakeerthi Nawarathna
Graduate Student Government Association Research Conference
Point-of-care (POC) electric field-based biosensors have emerged as a promising tool to detect early cancer biomarkers such as circulating tumor DNA (ctDNA), microRNA (miRNA), and proteins. To be effective in screening in clinical settings, these biosensors must be simple and easy to use. In this study, we have studied the manipulation of short DNA molecules suspended in a sessile drop to achieve this goal. Alternative current (AC) electric fields were used to polarize DNA molecules and produce dielectrophoretic (DEP) force on DNA molecules. DEP force is used to manipulate polarized DNA molecules towards the higher electric field gradients (toward the …
Cost-Effective Hierarchical Cobalt Nanostructured Laser-Induced Graphene For Enhanced Uric Acid Detection, Anju Joshi, Gymama Slaughter
Cost-Effective Hierarchical Cobalt Nanostructured Laser-Induced Graphene For Enhanced Uric Acid Detection, Anju Joshi, Gymama Slaughter
Center for Bioelectronics Publications
This study presents an innovative, cost-effective strategy to develop a flexible, enzyme-free biosensor for the sensitive detection of uric acid (UA). Utilizing electrochemically modified cobalt nanostructured on laser-induced graphene electrodes (CoNCs/LIG), this approach surpasses traditional noble metal-based electrocatalysts in sensitivity and affordability. The one-step electrochemical modification method is efficient and straightforward, enabling the uniform deposition of hierarchical flower-like cobalt nanostructures. These structures synergistically enhance the performance of the LIG, resulting in a broad detection range of 5 to 700 µM with a sensitivity of 6.75 µA µM-¹ cm-² and a low detection limit of 3.66 µM for UA. …
An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part I: Accelerometers And Ppg Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao
An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part I: Accelerometers And Ppg Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
This paper, the first of two parts, presents an analytical model of motion artifacts (MAs) in measured pulse signals by accelerometers and photoplethysmography (PPG) sensors. As the transmission path from the true pulse signal in an artery to the sensor output (measured pulse signal), the tissue-contact-sensor (TCS) stack is modeled as a 1DOF (degree-of-freedom) system. MAs cause baseline drift of the mass and simultaneously time-varying system parameters (TVSPs) of the TCS stack. With arterial wall displacement and pulsatile pressure serving separately as the true pulse signal, an analytical model is developed to mathematically relate baseline drift and TVSP to a …
Laser-Induced Graphene For Early Disease Detection: A Review, Sri Ramulu Torati, Gymama Slaughter
Laser-Induced Graphene For Early Disease Detection: A Review, Sri Ramulu Torati, Gymama Slaughter
Center for Bioelectronics Publications
Electrochemical biosensors have been instrumental in early disease detection, facilitating effective monitoring and treatment. The emergence of graphene has significantly advanced sensor technology in various fields, including biomedicine, electronics, and energy. In this landscape, laser‐induced graphene (LIG) has emerged as a superior alternative to conventional graphene synthesis methods. Its straightforward fabrication process and compatibility with wearable devices boost its practicality and potential for real‐world applications. This review highlights the transformative potential of LIG in biosensing, showcasing its contributions to the development of next‐generation diagnostic tools for early disease detection. An overview of the LIG synthesis process and its applications in …
The Effects Of Dental Hygiene Instrument Handles On Muscle Activity Production, Jessica R. Suedbeck, Daniel Russell, Cortney Armitano Lago, Emily A. Ludwig
The Effects Of Dental Hygiene Instrument Handles On Muscle Activity Production, Jessica R. Suedbeck, Daniel Russell, Cortney Armitano Lago, Emily A. Ludwig
Dental Hygiene Faculty Publications
Purpose The objective of this study was to compare the effects of ten commercially available instrument handle designs’ mass and diameter on forearm muscle activity during a simulated periodontal scaling experience.
Methods A convenience sample of 25 registered dental hygienists were recruited for this IRB-approved study. Ten commercially available instruments were categorized into four groups based on their masses and diameters: large diameter/light mass, small diameter/light mass, large diameter/heavy mass, and small diameter/heavy mass. Participants were randomized to four instruments with one from each group. Participants scaled with each instrument in a simulated oral environment while muscle activity was collected …
Senior Subject Gait Analysis Using Self-Supervised Method, Haben Yhdego, Michel Audette
Senior Subject Gait Analysis Using Self-Supervised Method, Haben Yhdego, Michel Audette
Modeling, Simulation and Visualization Student Capstone Conference
There are many issues regarding the technology used for fall detection gait analysis in the geriatric center of senior patients. The fall detection system used should examine the privacy of the patients and the flexibility of the system. Several researchers have developed fall detection using wearable sensors due to their flexibility and nature of privacy. Most of those developed methods are supervised deep learning methods. However, data annotation is expensive because we use camera video recording and playback of each participant’s recorded video to label the data. Moreover, labelling using a camera recording limits the flexible and private nature of …
Paper-Based Flexible Electrode Using Chemically-Modified Graphene And Functionalized Multiwalled Carbon Nanotube Composites For Electrophysiological Signal Sensing, Md Faruk Hossain, Jae Sang Heo, John Nelson, Insoo Kim
Paper-Based Flexible Electrode Using Chemically-Modified Graphene And Functionalized Multiwalled Carbon Nanotube Composites For Electrophysiological Signal Sensing, Md Faruk Hossain, Jae Sang Heo, John Nelson, Insoo Kim
Bioelectrics Publications
Flexible paper-based physiological sensor electrodes were developed using chemically-modified graphene (CG) and carboxylic-functionalized multiwalled carbon nanotube composites (f@MWCNTs). A solvothermal process with additional treatment was conducted to synthesize CG and f@MWCNTs to make CG-f@MWCNT composites. The composite was sonicated in an appropriate solvent to make a uniform suspension, and then it was drop cast on a nylon membrane in a vacuum filter. A number of batches (0%~35% f@MWCNTs) were prepared to investigate the performance of the physical characteristics. The 25% f@MWCNT-loaded composite showed the best adhesion on the paper substrate. The surface topography and chemical bonding of the proposed CG-f@MWCNT …
Effect Of Cold Atmospheric Plasma Treatment On The Metabolites Of Human Leukemia Cells, Dehui Xu, Ning Ning, Yujing Xu, Bingchuan Wang, Qingjie Cui, Zhijie Liu, Xiaohua Wang, Dingxin Liu, Hailan Chen, Michael G. Kong
Effect Of Cold Atmospheric Plasma Treatment On The Metabolites Of Human Leukemia Cells, Dehui Xu, Ning Ning, Yujing Xu, Bingchuan Wang, Qingjie Cui, Zhijie Liu, Xiaohua Wang, Dingxin Liu, Hailan Chen, Michael G. Kong
Bioelectrics Publications
Background
Acute myeloid leukemia (AML) is a typically fatal malignancy and new drug and treatment need to be developed for a better survival outcome. Cold atmospheric plasma (CAP) is a novel technology, which has been widely applied in biomedicine, especially in various of cancer treatment. However, the changes in cell metabolism after CAP treatment of leukemia cells have been rarely studied.
Methods
In this study, we investigated the metabolite profiling of plasma treatment on leukemia cells based on Gas Chromatography Tandem Time-of-Flight Mass Spectrometry (GC-TOFMS). Simultaneously, we conducted a series of bioinformatics analysis of metabolites and metabolic pathways with significant …
Antimicrobial Efficacy And Safety Of A Novel Gas Plasma-Activated Catheter Lock Solution, Sudhir Bhatt, Poonam Mehta, Chen Chen, Dayle A. Daines, Leonard A. Mermel, Hai-Lan Chen, Michael G. Kong
Antimicrobial Efficacy And Safety Of A Novel Gas Plasma-Activated Catheter Lock Solution, Sudhir Bhatt, Poonam Mehta, Chen Chen, Dayle A. Daines, Leonard A. Mermel, Hai-Lan Chen, Michael G. Kong
Bioelectrics Publications
Antimicrobial lock solutions are important for prevention of microbial colonization and infection of long-term central venous catheters. We investigated the efficacy and safety of a novel antibiotic-free lock solution formed from gas plasma-activated disinfectant (PAD). Using a luminal biofilm model, viable cells of methicillin-resistant Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and Candida albicans in mature biofilms were reduced by 6 to 8 orders of magnitude with a PAD lock for 60 min. Subsequent 24-h incubation of PAD-treated samples resulted in no detectable regrowth of viable bacteria or fungi. As a comparison, the use of a minocycline-EDTA-ethanol lock solution for 60 …
Thermally Assisted Pulsed Electric Field Ablation For Cancer Therapy, James Michael Hornef
Thermally Assisted Pulsed Electric Field Ablation For Cancer Therapy, James Michael Hornef
Biomedical Engineering Theses & Dissertations
Pulsed Electric Fields (PEF) have promised improved treatment results in a variety of cancer types including melanoma, pancreatic and lung squamous cancer. Recent studies show that PEF-based cancer therapy may be improved further with the assistance of moderate heating of the target. Experiments were performed to design, calibrate and implement a feedback-looped infrared laser irradiation system that could maintain specified temperatures during the treatment. The exact treatment area, penetration depth and thermal distribution of a 980-nm laser fiber were quantified using several methods, including the knife-edge technique and a tissue optical property study. In vivo and in vitro experiments using …
Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu
Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu
Mechanical & Aerospace Engineering Faculty Publications
The cell membrane is the interface that volumetrically isolates cellular components from the cell's environment. Proteins embedded within and on the membrane have varied biological functions: reception of external biochemical signals, as membrane channels, amplification and regulation of chemical signals through secondary messenger molecules, controlled exocytosis, endocytosis, phagocytosis, organized recruitment and sequestration of cytosolic complex proteins, cell division processes, organization of the cytoskeleton and more. The membrane's bioelectrical role is enabled by the physiologically controlled release and accumulation of electrochemical potential modulating molecules across the membrane through specialized ion channels (e.g., Na⁺, Ca2+, K⁺ channels). …
A Microfluidic-Based Tactile Sensor For Palpating Mice Tumor Tissues, Yichao Yang, Garett Johnson, Dean Krusienski, Siqi Guo, Cheng Lin, Zhili Hao
A Microfluidic-Based Tactile Sensor For Palpating Mice Tumor Tissues, Yichao Yang, Garett Johnson, Dean Krusienski, Siqi Guo, Cheng Lin, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
In light of the need of tissue palpation for Robotics-assisted Minimally Invasive Surgery (RMIS), this paper presents a microfluidic-based tactile sensor for palpating mice tissues for tumor localization. The core of the sensor is a 3x3 sensing-plate/transducer array built into a single polydimethylsiloxane (PDMS) microstructure, with a transducer spacing of 3.75mmx1.5mm. Mounted on a robot, the sensor is pressed against a tissue region with a pre-defined indentation depth pattern, and consequently the stiffness distribution across the tissue region translates to the deflection distribution of the sensing-plate array and is captured by the transducer array underneath as resistance changes. Thus, the …
Impairment Of Continuous Insulin Delivery Therapy And Analysis From Graeco-Latin Square Design Model, Norou Diawara, Ayodeji Demuren, Eric Gyuricsko
Impairment Of Continuous Insulin Delivery Therapy And Analysis From Graeco-Latin Square Design Model, Norou Diawara, Ayodeji Demuren, Eric Gyuricsko
Mathematics & Statistics Faculty Publications
The desire to deliver measured amount of insulin continuously to patients with type I diabetes, for glycemic control, has attracted a lot of attention. Continuous subcutaneous insulin infusion has seen some success in recent years. However, occlusion of insulin delivery may prevent the patient from receiving the prescribed dosage, with adverse consequence. An in vitro study of insulin delivery is performed, using different insulin pumps, insulin analogs and operating conditions. The aim is to identify incidences of occlusion due to bubble formation in the infusion line. A detailed statistical analysis was performed on the data collected to determine any significant …
The Effect Of Posterior Foot Positions On Electromyography, Joint Kinetics And Energetics During A Sit-To-Stand In Young And Older Adults, Eric A. Pitman
The Effect Of Posterior Foot Positions On Electromyography, Joint Kinetics And Energetics During A Sit-To-Stand In Young And Older Adults, Eric A. Pitman
Human Movement Studies & Special Education Theses & Dissertations
The sit-to-stand (STS) movement, defined as standing up from a chair to an upright posture, is a common task performed daily. The inability to accomplish this task may lead to dependence, institutionalization and even death in older adults. A common strategy change for the STS is positioning the feet posteriorly by increasing flexion at the knee joint. This reduces the displacement of the center of mass to the base of support while increasing the joint moment of force at the knee while decreasing it at the hip. The aims of this study were to: 1) examine the joint kinetics, joint …
Alignment And Composition Of Laminin-Polycaprolactone Nanofiber Blends Enhance Peripheral Nerve Regeneration, Rebekah A. Neal, Sunil S. Tholpady, Patricia L. Foley, Nathan Swami, Roy C. Ogle, Edward A. Botchwey
Alignment And Composition Of Laminin-Polycaprolactone Nanofiber Blends Enhance Peripheral Nerve Regeneration, Rebekah A. Neal, Sunil S. Tholpady, Patricia L. Foley, Nathan Swami, Roy C. Ogle, Edward A. Botchwey
School of Medical Diagnostics & Translational Sciences Publications
Peripheral nerve transection occurs commonly in traumatic injury, causing deficits distal to the injury site. Conduits for repair currently on the market are hollow tubes; however, they often fail due to slow regeneration over long gaps. To facilitate increased regeneration speed and functional recovery, the ideal conduit should provide biochemically relevant signals and physical guidance cues, thus playing an active role in regeneration. To that end, laminin and lamininpolycaprolactone (PCL) blend nanofibers were fabricated to mimic peripheral nerve basement membrane. In vitro assays established 10% (wt) laminin content is sufficient to retain neurite-promoting effects of laminin. In addition, modified collector …
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Electrical & Computer Engineering Theses & Dissertations
The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …
Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi
Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi
Electrical & Computer Engineering Theses & Dissertations
This thesis presents a three-step method to predict prostate cancer (PCa) regions on biopsy tissue samples based on high confident, low resolution PCa regions marked by a pathologist. First, a prediction model is designed to predict PCa regions using matrix-assisted laser desorption mass spectrometry (MALDI-MS) tissue imaging data from one prostate tissue slice. Second, a texture analysis technique is applied to a high magnification optical image for the same purpose from an adjacent tissue slice. Finally, those two results are fused to obtain the PCa regions that will assist MALDI imaging biomarker analysis. Experiments show that the texture analysis based …
Ekg Tracking For Augmented Standardized Patient Virtual Pathology Stethoscope Heart Auscultation, Sujith Surendran
Ekg Tracking For Augmented Standardized Patient Virtual Pathology Stethoscope Heart Auscultation, Sujith Surendran
Electrical & Computer Engineering Theses & Dissertations
In recent years, a lot of research has focused on improving the clinical skills of medical students and medical practitioners using standardized patients. Standardized patients (SP's) are used by the medical students and physicians in place of mannequins for a more realistic experience. SP's are real people trained to simulate specific illnesses and conditions to a high degree of accuracy which makes it difficult for the medical students to distinguish them from real patients. This research will enhance the capabilities of the standardized patients by providing a non-invasive, natural, harmless and realistic appearing tracking method for placing virtual pathologies using …
Prostate Cancer Biomarker Identification: A Comparative Study, Wenjuan Jiang
Prostate Cancer Biomarker Identification: A Comparative Study, Wenjuan Jiang
Computational Modeling & Simulation Engineering Theses & Dissertations
With the current development of proteomics techniques, the discovery of potential molecular biomarkers for early detection of prostate cancer has been greatly improved. In this thesis, we implemented five classifiers including the support vector machine (SVM), Bayesian Classifier, Decision Tree, Random Forest and the Multilayer perceptron (MLP) to test their effectiveness in prostate cancer biomarker identification using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) tissue imaging data. The classifiers were utilized to discriminate cancer mass spectra from normal ones for the data collected at the Eastern Virginia Medical School (EVMS). There are 94 7 spectra from normal tissues and 27 from …
Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou
Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou
Electrical & Computer Engineering Theses & Dissertations
Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones from noise contaminated signals obtained from passive acoustic sensors. A nonlinear Teager energy operator is utilized for detection of the fetal heart tone event. Autocorrelation and a parallel redundancy correction algorithm derives fetal heart rates. A real time monitoring system is described which records and plots the time history of both the fetal heart rate and the acoustic fetal heart signal. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a …
Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii
Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii
Electrical & Computer Engineering Theses & Dissertations
Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively "trained" in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the …