Articles 1 - 30 of 41

Full-Text Articles in Biomedical Devices and Instrumentation

Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat Dec 2012

Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat

Master's Theses

MEASURING IMPEDANCE OF TISSUES USING A MICROFABRICATED MICROELECTRODE ARRAY By Ashwini Bhat

This thesis looks at the possibility of using impedance spectroscopy for differentiating tissue, using a microelectrode array (MEA). The thesis first discusses the background and the motivation for this thesis. It covers the certain basic concepts of the human skin starting from the top epidermis layer all the way to the deep dermis layers of the skin. Then it discusses different types of skin cancer and how they occur, in humans. It also discusses various microfabrication techniques such as oxidation, wet etching, sputtering and photolithography for the creation …


Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel Dec 2012

Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel

Mechanical Engineering

This report covers the design and construction of the recumbent racing tricycle for Mr. Robert T. Kelly, a disabled veteran. Unfortunately Rob’s right leg is five inches shorter than his left one and therefore is unable to properly operate standard cranks. Our team HandiTrike is composed of Sean Higginson, Kevin Howie, and Vinay Patel and our project requires us to come up with a design that is feasible to complete within the given three quarters, as well as allow Rob to gain full use of his tricycle. Currently Rob ‘s trike uses the standard crank set up found on most …


Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee Dec 2012

Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee

Master's Theses

Off-label use of traditional Oropharyngeal Airway (OPA) as a bite-block, and the subsequential procedure of force exertion of the device by physician has caused many cases of patient’s teeth damage and monetary loss, as the patient’s incisors were damaged while clenching on the OPA during an adverse scenario called “Emergency Clenching”. To remedy this harmful situation, Bardo OPA was developed by Dr. Theodore Burdumy. The Bardo airway has unique design to transfer the clenching force from incisor to the molar. However, the Bardo OPA is one-sized, and cannot fit most of the patients like the commonly-used OPAs, such as the …


Fabrication Of Cao-Nao-Sio2/Tio2 Scaffolds For Surgical Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler Dec 2012

Fabrication Of Cao-Nao-Sio2/Tio2 Scaffolds For Surgical Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

A series of titanium (Ti) based glasses were formulated (0.62 SiO2-0.14 Na2O-0.24 CaO, with 0.05 mol% TiO2 substitutions for SiO2) to develop glass/ceramic scaffolds for bone augmentation. Glasses were initially characterised using X-ray diffraction (XRD) and particle size analysis, where the starting materials were amorphous with 4.5 μm particles. Hot stage microscopy and high temperature XRD were used to determine the sintering temperature (̃700 °C) and any crystalline phases present in this region (Na2Ca3Si6O16, combeite and quartz). Hardness testing revealed that the Ti-free control (ScC- …


Morphometric, Biochemical, And Raman Spctral Analyses Of Muscle Damage In Patients With Peripheral Arterial Disease: Provising Objective Criteria For Diagnosis And Treatment Monitoring, Kim Cluff Dec 2012

Morphometric, Biochemical, And Raman Spctral Analyses Of Muscle Damage In Patients With Peripheral Arterial Disease: Provising Objective Criteria For Diagnosis And Treatment Monitoring, Kim Cluff

Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research

Peripheral arterial disease (PAD), which affects approximately 10 million Americans, is characterized by atherosclerosis of the non-coronary arteries. PAD produces a progressive accumulation of ischemic injury to the limbs that is reflected in a gradual worsening in the myofiber morphology and oxidative damage in the gastrocnemius muscle. In this study, we evaluated the hypothesis that quantitative morphological and biochemical parameters of gastrocnemius myofibers change in a consistent manner during the progression of PAD, provide an objective grading of muscle degeneration in the ischemic limb, and correlate to clinical stage of PAD. Myofiber morphometrics were determined precisely with mathematical equations that …


On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming Dec 2012

On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming

Department of Mechanical and Materials Engineering: Faculty Publications

The stent-artery interactions have been increasingly studied using the finite element method for better understanding of the biomechanical environment changes on the artery and its implications. However, the deployment of balloon-expandable stents was generally simplified without considering the balloon-stent interactions, the initial crimping process of the stent, its overexpansion routinely used in the clinical practice, or its recoil process. In this work, the stenting procedure was mimicked by incorporating all the above-mentioned simplifications. The impact of various simplifications on the stent-induced arterial stresses was systematically investigated. The plastic strain history of stent and its resulted geometrical variations, as well as …


Compression Transmission Collar For Fastening, Patrick Atkinson Nov 2012

Compression Transmission Collar For Fastening, Patrick Atkinson

Mechanical Engineering Patents

A compression transmission collar apparatus (20) for implantation into a bone (22) with a hole (28) having a hole wall (32) comprising an intramedullary nail (34) defining a bore (40) and a threaded fastener (42) and a compression transmission collar (58) including an exterior face (64) and a top edge (60) and a bottom edge (62) and a first end (70) intersecting the top edge (60) at an acute angle (α1) and …


Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier Oct 2012

Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier

Mechanical Engineering Patents

An intramedullary nail (20) for insertion into the medullary canal (26) in a bone (24) surrounded by the cortex (28) and defines a bore (34) extending transverse to the intramedullary nail (20). A threaded fastener (22) extends along a fastener axis (A) and has a compression portion (48) having a compression portion diameter (DCP), and a threaded portion (50) having a threaded portion diameter (DTP) extending through a near cortex hole (40) and a far cortex hole (42), both holes (40, 42) radially overlapping the bore (34) and the threaded portion diameter (DTP) threadedly engaging the bore (34). A compression …


Method And Apparatus For Utilizing Amplitude-Modulated Pulse-Width Modulation Signals For Neurostimulation And Treatment Of Neurological Disorders Using Electrical Stimulation, Jeffrey Hargrove, Theodore Stokes, Mary L. Esty Oct 2012

Method And Apparatus For Utilizing Amplitude-Modulated Pulse-Width Modulation Signals For Neurostimulation And Treatment Of Neurological Disorders Using Electrical Stimulation, Jeffrey Hargrove, Theodore Stokes, Mary L. Esty

Mechanical Engineering Patents

A computing device-controlled system is described for the generation of amplitude-modulated pulse-width modulation (AMPWM) signals for use in treating neurological dysfunction via cranial neurostimulation, where the AMPWM signal is specifically designed to minimize the electrical impedance of the tissues of the head. A low-frequency carrier signal is determined for the AMPWM signal by measuring EEG activity at a reference site or sites, generally corresponding with the location of suspected brain dysfunction. Carrier signal frequency is variably related to critical frequency components of the EEG power spectral density, determined from statistical analysis of amplitudes and variability, and dynamically changed as a …


A Low Cost Motion Analysis System Based On Kinect, Jonathan Michael Cardinale, Tracy N. Jennemann, Vitaliy Sinyuk, Sam Kenji Yokoyama Sep 2012

A Low Cost Motion Analysis System Based On Kinect, Jonathan Michael Cardinale, Tracy N. Jennemann, Vitaliy Sinyuk, Sam Kenji Yokoyama

Undergraduate Research Posters 2012

The project focused on the validation of using the Kinect sensor to build a low cost motion analysis system for physical therapy and rehabilitation, and the identification of the types of the motions that cannot be captured well by the Kinect sensor and are in need of inertial sensors.


Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar Sep 2012

Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar

Master's Theses

A continuous flow, passive separation device was designed using an equivalent circuit to create variable flow rates for hydrodynamic focusing to drain channels and collection outlets. By varying the diameter of the sample inlet connection into the reservoir, the particle position was influenced significantly, which enabled desired separations. Additionally it was noted that the relative, horizontal position of the inlet also had a significant influence on particle position within the device. A dimensionless number, the Characteristic Sample Inlet, was developed to relate geometric properties of the inlet reservoir to downstream particle distribution. It was found that a 2:1 ratio between …


Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam Sep 2012

Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam

Master's Theses

The following paper describes a fall detection and activity monitoring system with position detection based on Zigbee transceivers.The main objective is to reduce the time taken for emergency personnel to respond to falls among the elderly. Especially when the victim is unconscious or delirious, position tracking reduces location determination time within a busy hospital or nursing home environment and facilitates immediate treatment. Reduced response times correlate to decreased morbidity and mortality rates. Background is provided on the major wireless network advances currently deployed in a healthcare setting for asset and personnel tracking, etiology of falls, and several methods of detecting …


Developing Novel Prognostic Biomarkers For Multivariate Fracture Risk Prediction Algorithms, Ernest K. Poku, Mark R. Towler, Niamh M. Cummins, Jeff D. Newman Sep 2012

Developing Novel Prognostic Biomarkers For Multivariate Fracture Risk Prediction Algorithms, Ernest K. Poku, Mark R. Towler, Niamh M. Cummins, Jeff D. Newman

Chemical and Biochemical Engineering Faculty Research & Creative Works

Multivariate prediction algorithms such as FRAX® and QFracture Scores provide an opportunity for new prognostic biomarkers to be developed and incorporated, potentially leading to better fracture prediction. As more research is conducted into these novel biomarkers, a number of factors need to be considered for their successful development for inclusion in these algorithms. In this review, we describe two well-known multivariate prediction algorithms for osteoporosis fracture risk applicable to the UK population, FRAX and QFracture Scores, and comment on the current prognostic tools available for fracture risk; dual X-ray assessment, quantitative ultrasonography, and genomic/biochemical markers. We also highlight the factors …


Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence On Scan Direction And Velocity, Tiantian Xu Aug 2012

Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence On Scan Direction And Velocity, Tiantian Xu

Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research

Cardiovascular disease is the leading cause death in the United States. Although emergency surgery and medicine can be used for cardiovascular disease treatment, the survivors will suffer for it afterwards. Ultrasound blood flow measurement provides a noninvasive way for cardiovascular diseases diagnosis. In this dissertation, three algorithms for blood flow velocity measurements were investigated and optimized. Feature tracking has been previously proposed for vector velocity measurement. In Chapter 3, the optimal amplitude and time thresholds for feature extraction were investigated to minimize flow estimate variance while providing sufficient spatial and temporal coverage of flow area. A new method of lateral …


Gallium Containing Glass Polyalkenoate Anti-Cancerous Bone Cements: Glass Characterization And Physical Properties, A. W. Wren, A. Coughlan, L. Placek, Mark R. Towler Aug 2012

Gallium Containing Glass Polyalkenoate Anti-Cancerous Bone Cements: Glass Characterization And Physical Properties, A. W. Wren, A. Coughlan, L. Placek, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

A gallium (Ga) glass series (0.48SiO2-0.40ZnO-0.12CaO, with 0.08 mol% substitution for ZnO) was developed to formulate a Ga-containing Glass Polyalkenoate Cement (GPC) series. Network connectivity (NC) and X-ray Photoelectron Spectroscopy (XPS) was employed to investigate the role of Ga3+ in the glass, where it is assumed to act as a network modifier. Ga-GPC series was formulated with E9 and E11 polyacrylic acid (PAA) at 50, 55 and 60 wt% additions. E11 working times (Tw) ranged from 68 to 96 s (Lcon.) and 106 s for the Ga-GPCs (LGa-1 and LGa-2). Setting times (Ts) …


Experimental Composite Guidance Conduits For Peripheral Nerve Repair: An Evaluation Of Ion Release, X. F. Zhang, A. Coughlan, H. O'Shea, Mark R. Towler, S. Kehoe, D. Boyd Aug 2012

Experimental Composite Guidance Conduits For Peripheral Nerve Repair: An Evaluation Of Ion Release, X. F. Zhang, A. Coughlan, H. O'Shea, Mark R. Towler, S. Kehoe, D. Boyd

Chemical and Biochemical Engineering Faculty Research & Creative Works

Poly (lactide-co-glycolide) (PLGA) - Pluronic F127 - glass composites have demonstrated excellent potential, from the perspective of controlled mechanical properties and cytocompatibility, for peripheral nerve regeneration. In addition to controlling the mechanical properties and cytotoxicity for such composite devices, the glass component may mediate specific responses upon implantation via degradation in the physiological environment and release of constituent elements. However, research focused on quantifying the release levels of such therapeutic ions from these experimental medical devices has been limited. To redress the balance, this paper explores the ion release profiles for Si4+, Ca2+, Na+, …


Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi Jul 2012

Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Laparo-Endoscopic Single Site (LESS) Robotics Surgery is an advanced technology in the field of Minimally Invasive Surgery (MIS). The LESS surgical robots significantly improve the surgeon’s accuracy, dexterity and visualization, and reduce the invasiveness of surgical procedure results in faster recovery time and improved cosmetic results. In a standard robotic endosurgery, the palpation of tissues is performed by laparoscopic graspers located at the end effectors. The master-slave configuration in robotic surgery leads in remote access to the operation site. Therefore, surgeon’s ability to perceive valuable sensory information is severely diminished. Sensory information such as haptics, which is essential for safe …


Development And Characterization Of An In-House Custom Bioreactor For The Cultivation Of A Tissue Engineered Blood-Brain Barrier, Amin Hadi Mirzaaghaeian Jul 2012

Development And Characterization Of An In-House Custom Bioreactor For The Cultivation Of A Tissue Engineered Blood-Brain Barrier, Amin Hadi Mirzaaghaeian

Master's Theses

The development of treatments for neurological disorders such as Alzheimer’s and Parkinson’s disease begins by understanding what these diseases affect and the consequences of further manifestation. One particular region where these diseases can produce substantial problems is the blood-brain barrier (BBB). The BBB is the selective diffusion barrier between the circulating blood and the brain. The barrier’s main function is to maintain CNS homeostasis and protect the brain from the extracellular environment. The progression of BBB research has advanced to the point where many have modeled the BBB in vitro with aims of further characterizing and testing the barrier. Particularly, …


The Structural Characterization Of Ga 2o 3-Na 2o-Cao-Zno-Sio 2 Bioactive Glasses, T. J. Keenan, A. W. Wren, A. Coughlan, M. M. Hall, Mark R. Towler Jun 2012

The Structural Characterization Of Ga 2o 3-Na 2o-Cao-Zno-Sio 2 Bioactive Glasses, T. J. Keenan, A. W. Wren, A. Coughlan, M. M. Hall, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

The characterization of bioactive glasses in which zinc (Zn) has been incrementally replaced by gallium (Ga). © 2012 IEEE.


Silver Coated Bioactive Glass Particles For Wound Healing Applications, P. Hassanzadeh, A. W. Wren, Mark R. Towler Jun 2012

Silver Coated Bioactive Glass Particles For Wound Healing Applications, P. Hassanzadeh, A. W. Wren, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Hench and colleagues discovered that bone could bond chemically to certain glass compositions in 1969 [1]. This group of glasses is known as bioactive glasses [1]. Some special compositions of bioactive glasses will bond to soft tissues as well as bone [1]. One of the important characteristics of bioactive glasses is their ability to release beneficial ions such as Ca2+, Na+, Zn2+, Sr2+, and PO 43- in the body, which promote self-healing [2]. Bioactive glasses generally contain much less glass former (e.g., SiO2, B2O3 etc.) than conventional …


Increasing The Quantity Of Silver In Zinc-Based Glass Polyalkenoate Cement: Is There An Improvement In Antibacterial Efficacy?, A. Coughlan, S. M. Breed, C. Ashraf, J. A. Cardinale, M. M. Hall, Mark R. Towler Jun 2012

Increasing The Quantity Of Silver In Zinc-Based Glass Polyalkenoate Cement: Is There An Improvement In Antibacterial Efficacy?, A. Coughlan, S. M. Breed, C. Ashraf, J. A. Cardinale, M. M. Hall, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Bone cements should have the ability to chemically bond to both bone and surgical metals, exhibit no chemical or thermal necrosis, and have no significant shrinkage or exotherm upon setting. Taking these properties into consideration, glass polyalkenoate cements (GPCs) have potential as bone cements. GPCs are formed by the reaction between an ion-leachable glass and an aqueous solution of polyacrylic acid (PAA) [1] and have proven antibacterial and cariostatic properties [2], which are related to their ability to release beneficial amounts of ions over time [3, 4]. The GPCs can be formulated to release ions that can have a therapeutic …


Gallium Containing Glass Polyalkenoate Bone Cements: Glass Characterization And Physical Properties, L. Placek, A. W. Wren, A. Coughlan, Mark R. Towler Jun 2012

Gallium Containing Glass Polyalkenoate Bone Cements: Glass Characterization And Physical Properties, L. Placek, A. W. Wren, A. Coughlan, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Gallium (Ga) glasses were developed to formulate a Glass Polyalkenoate Cement (GPC) series with both E9 and E11 polyacrylic acid (PAA) at 50, 55 and 60wt% additions. Working times (T w), setting times (T s), compression (σ c), and biaxial flexural (σ f) strength testing were evaluated to determine the GPCs potential use in orthopedics. © 2012 IEEE.


A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle Jun 2012

A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …


A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen Jun 2012

A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen

Master's Theses

A new detection reagent that could possibly augment or replace antibodies research and diagnosis methods are aptamers. Aptamers are ssDNA, RNA or polypeptide constructs that function like active antibodies. Antibodies and aptamers both specifically bind to selected target molecules, and as such they enable the detection or targeting of the presence or absence of a specific antigen.

In order to ensure that ssDNA aptamers perform similarly to antibodies, anti-VEGF-A polyclonal antibody and anti-VEGF-A ssDNA aptamer were evaluated against vascular endothelial growth factor A (VEGF-A) using Surface Plasmon Resonance (SPR). It was hypothesized that the anti-VEGF-A aptamer had the same, if …


Impedance Sensing Of N2a And Astrocytes As Grounds For A Central Nervous System Cancer Diagnostic Device, Fraser Traves Smith Grove Jun 2012

Impedance Sensing Of N2a And Astrocytes As Grounds For A Central Nervous System Cancer Diagnostic Device, Fraser Traves Smith Grove

Master's Theses

This thesis utilizes previously described manufacturing and design techniques for the creation of a PDMS-glass bonded microfluidic device, capable of electrochemical impedance spectroscopy (EIS). EIS has been used across various fields of research for different diagnostic needs. The major aim of this thesis was to capture cancerous and non-cancerous cells between micron sized electrodes within a microfluidic path, and to complete analysis on the measured impedances recorded from the two differing cell types. Two distinct ranges of impedance frequency were analyzed – the α dispersion range, which quantifies the impedance of the membranes of the cells of interest, and the …


Testing And Validation Of An Autostainer, Nicholas Hanne Jun 2012

Testing And Validation Of An Autostainer, Nicholas Hanne

Biomedical Engineering

Histology performed by Cal Poly students for research projects and labs are currently performed by hand using a dipping technique. This technique is time consuming, expensive, imprecise, and often unrepeatable. Central Coast Pathology donated a Dako Autostainer to the Biomedical Engineering Department that can perform immunohistological stains of up to 48 samples simultaneously using tightly controlled reagent volumes and incubation times. Protocols are programmed into the machine and can be repeated under the same conditions every time with minimal preparation and exposure to potentially dangerous reagents. The autostainer was repaired and validated by comparing PECAM & BBI stains performed on …


A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils May 2012

A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils

Master's Theses

Biomechanical risk factors are physical stressors that act on the neuromuscular structures of the human body and are present in all occupational settings. Repetition and intensity of tasks performed can magnify the effects of the biomechanical risks that a worker is exposed to.

After reviewing the current literature on ergonomics in laparoscopic surgery it was clear that a comprehensive approach to quantitatively reporting on the biomechanical risk factors associated with surgical hand tools had never been performed. Utilizing an opto-electronic motion capture system meant the exact surgeon posture was recorded during simulated surgical tasks. Electromyography was used to evaluate muscle …


Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory May 2012

Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Adverse events due to medical errors are a leading cause of death in the United States exceeding the mortality rates of motor vehicle accidents, breast cancer and AIDS. Improvements can and should be made to reduce the rates of preventable surgical errors since they account for nearly half of all adverse events within hospitals. Although minimally invasive surgery has proven patient benefits such as reduced postoperative pain and hospital stay, its operative environment imposes substantial physical and cognitive strain on the surgeon increasing the risk of error. In order to mitigate errors and protect patients, a multidisciplinary approach was taken …


Silver Coated Bioactive Glass Particles For Wound Healing Applications, A. W. Wren, A. Coughlan, P. Hassanzadeh, Mark R. Towler May 2012

Silver Coated Bioactive Glass Particles For Wound Healing Applications, A. W. Wren, A. Coughlan, P. Hassanzadeh, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Bioactive glass particles (0.42SiO2-0.15CaO-0.23Na 2O-0.20ZnO) of varying size (<90 >μm and 425-850 μm) were synthesized and coated with silver (Ag) to produce Ag coated particles (PAg). These were compared against the uncoated analogous particles (Pcon.). Surface area analysis determined that Ag coating of the glass particles resulted in increased the surface area from 2.90 to 9.12 m2/g (90 μm) and 1.09-7.71 m2/g (425-850 μm). Scanning electron microscopy determined that the Ag coating remained at the surface and there was little diffusion through the bulk. Antibacterial (Escherichia coli - 13 mm and Staphylococcus epidermidis …