Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (17)
- University of Arkansas, Fayetteville (14)
- University of Nebraska - Lincoln (14)
- The University of Akron (13)
- Old Dominion University (11)
-
- University of Nevada, Las Vegas (10)
- Purdue University (9)
- University of Kentucky (8)
- Virginia Commonwealth University (8)
- Dartmouth College (7)
- University of Mississippi (7)
- Marquette University (5)
- University of Denver (5)
- University of New Mexico (5)
- Brigham Young University (4)
- City University of New York (CUNY) (4)
- Clemson University (4)
- University of Louisville (4)
- University of South Alabama (4)
- Wayne State University (4)
- West Virginia University (4)
- Embry-Riddle Aeronautical University (3)
- Loma Linda University (3)
- Louisiana State University (3)
- Technological University Dublin (3)
- The Texas Medical Center Library (3)
- University of Connecticut (3)
- University of Malaya (3)
- University of North Florida (3)
- Children's Health Medical Center Dallas (2)
- Keyword
-
- Biomedical engineering (9)
- Machine learning (6)
- Biomedical Engineering (5)
- Microfluidics (5)
- Biomechanics (4)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (4)
- Gait (4)
- Hydrogel (4)
- Motor control (4)
- Prosthetics (4)
- 3D printing (3)
- Angiogenesis (3)
- Arduino (3)
- Arthroplasty (3)
- Cardiovascular disease (3)
- Cochlear implant (3)
- Electro-larynx (3)
- Endothelial Dysfunction (3)
- Engineering (3)
- Ergonomics (3)
- Heart failure (3)
- Intelligibility (3)
- Laryngectomy (3)
- Neuromodulation (3)
- Parkinson's Disease (3)
- Radiotherapy (3)
- Sensors (3)
- Simulation (3)
- Wearable technology (3)
- 3D-Printing (2)
- Publication Year
- Publication
-
- Williams Honors College, Honors Research Projects (13)
- Electronic Theses and Dissertations (10)
- Master's Theses (10)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (9)
- Honors Theses (8)
-
- The Summer Undergraduate Research Fellowship (SURF) Symposium (7)
- Biomedical Engineering (6)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (6)
- Graduate Theses and Dissertations (6)
- Theses and Dissertations (6)
- Theses and Dissertations--Biomedical Engineering (5)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (4)
- All Theses (3)
- Biomedical Engineering ETDs (3)
- Biomedical Engineering Undergraduate Honors Theses (3)
- Biomedical Engineering Western Regional Conference (3)
- Conference Papers (3)
- Dartmouth College Master’s Theses (3)
- Loma Linda University Electronic Theses, Dissertations & Projects (3)
- Master's Theses (2009 -) (3)
- Mechanical & Aerospace Engineering Faculty Publications (3)
- Student Works (2020-2029) (3)
- 2026 (2)
- Annual Research Symposium (2)
- Bioelectrics Publications (2)
- Biology and Medicine Through Mathematics Conference (2)
- Center for Bioelectronics Publications (2)
- Dartmouth College Ph.D Dissertations (2)
- Department of Mechanical and Materials Engineering: Faculty Publications (2)
- Discovery Day - Daytona Beach (2)
- Publication Type
- File Type
Articles 1 - 30 of 236
Full-Text Articles in Biomedical Devices and Instrumentation
Comparative Analysis Of Takagi-Sugeno And Mamdani Fuzzy Inference Architectures With Anfis-Based Automated Rule Generation For Eeg-Based Cognitive State Monitoring, Amina Radončić, Mehrija Hasičić, Jasmin Kevrić
Comparative Analysis Of Takagi-Sugeno And Mamdani Fuzzy Inference Architectures With Anfis-Based Automated Rule Generation For Eeg-Based Cognitive State Monitoring, Amina Radončić, Mehrija Hasičić, Jasmin Kevrić
Communications of the IIMA
Fuzzy inference systems have demonstrated considerable promise for EEG-based cognitive state monitoring in neurodegenerative conditions. However, two design decisions significantly influence system performance and clinical applicability: the choice of inference architecture (Takagi-Sugeno vs Mamdani) and the method of rule and membership function generation (manual expert-driven vs data-driven automated). This paper presents a comparative analysis of both dimensions in the context of an EEG-based Alzheimer’s disease monitoring system operating on the ds004504 OpenNeuro dataset (88 subjects: 36 AD, 23 FTD, 29 HC). A Takagi-Sugeno system, implemented as a hybrid FSM-Fuzzy architecture, is compared against a Mamdani equivalent across four axes: inference …
Assessing Non-Thermal Plasma In Cutaneous Regeneration, Arden Rodriguez, Meliah Martin, Graeme Grainger, Arineh Shahbazi
Assessing Non-Thermal Plasma In Cutaneous Regeneration, Arden Rodriguez, Meliah Martin, Graeme Grainger, Arineh Shahbazi
Discovery Day - Daytona Beach
Chronic and acute wounds remain a significant clinical challenge, particularly in austere and resource-limited environments where access to advanced care is restricted. Non-Thermal Plasma (NTP) has emerged as a promising, non-invasive modality with reported antimicrobial and regenerative properties; however, its mechanisms of action and effects on human skin tissue require further characterization. The scope of this project is to engineer and utilize a 3D human skin epithelial model to evaluate the effects of NTP on wound healing. We will first build a 3D epithelial tissue model that will simulate human skin, followed by modeling and evaluation of wound pathology and …
Simulating Pacemakers And Heartbeat Recovery Through Mathematical Modeling, Thomas Estrada, Jayla Edwards
Simulating Pacemakers And Heartbeat Recovery Through Mathematical Modeling, Thomas Estrada, Jayla Edwards
Discovery Day - Daytona Beach
Title: Simulating Pacemakers and Heartbeat Recovery Through Mathematical Modeling This study utilizes the Fitzhugh-Nagumo model to simulate cardiac electrical activity and the regulatory role of pacemakers through ordinary differential equations (ODEs). By defining the rate of change for membrane voltage, 𝑑𝑣/dt, and a recovery variable, 𝑑𝑤/dt, the model captures the heart's excitability and resting states. Central to the analysis is the stimulus current parameter, which represents the "kick" provided by a pacemaker to correct flatline conditions or weak heartbeats. Using Euler’s method for numerical integration, the research compares unstable cardiac rhythms against corrected periodic oscillations. Additionally, the project implements vector …
Evaluating Chest-Worn Light Logger Adherence: Development And Application Of A Wear/Non-Wear Model, Carlyn Patterson Gentile, Adah Thomas, Ryan Shah, Blanca Marquez De Prado, Nichelle Raj, Christina Szperka, Geoffrey Aguirre
Evaluating Chest-Worn Light Logger Adherence: Development And Application Of A Wear/Non-Wear Model, Carlyn Patterson Gentile, Adah Thomas, Ryan Shah, Blanca Marquez De Prado, Nichelle Raj, Christina Szperka, Geoffrey Aguirre
Student Papers, Posters & Projects
Light exposure plays an important role in overall health because it entrains circadian rhythms. Recent technological advances in wearable light loggers allow measurement daily light exposure habits. Using a chest-worn light logger, our goal was to (1) develop methodology for differentiating adherent versus non-adherent use, and (2) define differences in lighting intensity in indoor and outdoor environments, to improve data reliability in future clinical studies using this technology. Four testers used a 10-channel chest worn light logging device under different conditions of wear and non-wear (experiment 1), and another tester made measurements with the light logger across a variety of …
Transcranial Ac Modulation Of Cerebellar Nuclear Activity In Awake Animals, Nuran Kavakli
Transcranial Ac Modulation Of Cerebellar Nuclear Activity In Awake Animals, Nuran Kavakli
Dissertations
Entrainment of cerebellar nuclear (CN) cells via cerebellar transcranial alternating current stimulation (ctACS) has been reported in animals under ketamine/xylazine anesthesia. Our main objective was to demonstrate modulation of CN activity in unanesthetized, freely moving animals using ctACS. Multi-channel carbon-fiber electrodes were implanted into the interpositus nucleus for recording multi-unit (MU) activity, and thin-film electrodes were implanted subcutaneously over the posterior cerebellum for stimulation. A frequency-domain-based metric was developed to quantify modulation from MU signals. The results demonstrated modulation in a wide range of frequencies (4 Hz-300 Hz) as in anesthetized animals. In contrast, the amplitude of the peak in …
Characterizing Stiffness Dynamics Of Normal And Malignant Breast Spheroids Using Brillouin Microscopy, Razanne Rafat Zaghloul, Karlin Hilai, Chenjun Shi, Jitao Zhang
Characterizing Stiffness Dynamics Of Normal And Malignant Breast Spheroids Using Brillouin Microscopy, Razanne Rafat Zaghloul, Karlin Hilai, Chenjun Shi, Jitao Zhang
Medical Student Research Symposium
Background: Breast cancer progression and metastasis are closely linked to alterations in the mechanical properties of tumor cells and their microenvironment. Softer, more deformable cells are often associated with higher metastatic potential. While atomic force microscopy (AFM) is the current gold standard for mechanical characterization, it is limited to surface measurements and can damage 3D cultures. It remains unclear how the mechanical properties evolve over time in normal versus malignant spheroids. This study utilizes Brillouin light-scattering microscopy, a non-contact and label-free optical technique, to assess stiffness changes in normal and malignant breast epithelial spheroids over time. Understanding these mechanical signatures …
Hyposense: Multimodal Physiologic And Voc Wearable For Early Hypoglycemia Detection, Nidhi R. Patel
Hyposense: Multimodal Physiologic And Voc Wearable For Early Hypoglycemia Detection, Nidhi R. Patel
Honors Theses
Hypoglycemia remains a significant safety concern for insulin-dependent individuals, especially when blood glucose declines rapidly during exercise, sleep, or periods of impaired hypoglycemia awareness. Current continuous glucose monitors and automated insulin delivery systems have helped to improve diabetes management, but these technologies primarily respond to glucose trends after they have already started and may not actually provide sufficient warning before symptoms occur. This thesis describes the development of HypoSense, a noninvasive wrist worn wearable concept that is designed to support earlier hypoglycemia risk detection through multimodal physiologic and volatile organic compound emission sensing. HypoSense combines volatile organic compounds/gas sensing with …
Effects Of A Passive Assistive Hamstring Device On Overground Running Kinematics And Hamstring Activation., Quinn Castner
Effects Of A Passive Assistive Hamstring Device On Overground Running Kinematics And Hamstring Activation., Quinn Castner
All Theses
Hamstring strain injuries are among the most common and recurring injuries in sports, occurring most often during the terminal swing phase of gait. Despite progress in rehabilitation, the incidence of injury has only increased, suggesting a need for a novel intervention. We designed a passive, assistive, wearable device with two specific criteria in mind: to offload the hamstrings during running, and do so without hindering normal kinematic patterns. The device consists of an adjustable elastic band anchored proximally at the waist and distally just above the ankle joint center. It stretches and shortens with the hamstrings, providing passive hip extension …
Modeling Structural Support To Facilitate Novel Treatments Of Degenerative Disc Disease, Jose Luis Calderon
Modeling Structural Support To Facilitate Novel Treatments Of Degenerative Disc Disease, Jose Luis Calderon
Poster Presentations
Over 600 million people worldwide suffered from low back pain in 2020, with projections for 2050 being over 800 million [1]. Annual costs associated with low back pain total over 450 billion dollars in the US alone [2]. This research serves as a proof-of-concept for the use of structural supports to facilitate intervertebral disc healing. This treatment would involve the implementation of these supports along with existing injection treatments to promote regeneration. In both models, along with the combined model, the ability for these supports to alleviate intervertebral disc height loss is shown. This indicates that these supports would serve …
Development Of Low-Cost Triaxial Force Sensor For Measurement Of Human-Exoskeleton Interaction Forces, Hamdan Khan Sarvathullah
Development Of Low-Cost Triaxial Force Sensor For Measurement Of Human-Exoskeleton Interaction Forces, Hamdan Khan Sarvathullah
All Theses
Contemporary research suggests that shear force is a major contributor to discomfort and pressure injury. However, the variation of shear forces during human-exoskeleton interaction dynamics is a highly unexplored field. The high cost of commercial triaxial force sensors may be a major factor in the notable lack of research in this field. Therefore, in this paper, we present a low-cost, 3D-printed triaxial force sensor designed specifically to measure the triaxial interaction forces between an exoskeleton and its user. The triaxial force sensor uses Carbon-Black/Silicone Rubber (CB/SR) strings to measure shear forces, whereas the normal force is measured with a Force …
Quantitative Fluorescence Imaging Using A Paired Agent Approach For Improving Surgical Decision Making, Sanjana Pannem
Quantitative Fluorescence Imaging Using A Paired Agent Approach For Improving Surgical Decision Making, Sanjana Pannem
Dartmouth College Ph.D Dissertations
Surgical resection remains to be the cornerstone of treatment for most solid tumors, where the primary objective is to remove all visible and microscopic disease. However, the extent of tumor resection is inherently limited by the surgeon’s ability to distinguish tumor from normal tissue, intraoperatively. As a result, positive surgical margins (PSM), where residual tumor remains after surgery, are a common occurrence and are associated with increased recurrence, need for adjuvant therapies, dismal patient outcomes, and high healthcare costs.
Fluorescence guided surgery (FGS) has emerged as a promising technique to enhance intraoperative visualization of tumors and may help reduce the …
A Treatise On Tool Development: The Arthroscope’S Cultural, Technological, And Metascientific Translation, Montgomery F. Waterer
A Treatise On Tool Development: The Arthroscope’S Cultural, Technological, And Metascientific Translation, Montgomery F. Waterer
Honors Theses
The arthroscope was a revolutionary development in the fields of medicine, engineering, and ethics. There are many valuable lessons to be learned from the story of its development and translation that are relevant to the future of medicine and society. Beginning with a brief description of the tool’s design, this paper will examine a period within the history of the arthroscope. This window contains multiple innovators and ends with the life and work of Dr. Robert Jackson. In examining the relevant historical facts of its development, this paper will then briefly address the importance of sports medicine in the development …
Robust Non-Invasive Cardiac Index Prediction Via Feature Integration And Data-Augmented Neural Networks, Chih-Hao Chang, Mei-Ling Chan, Yu-Hung Fang, Po-Lin Huang, Tsung-Yi Chen, Tsun-Kuang Chi, I Elizabeth Cha, Tzong-Rong Ger, Kuo-Chen Li, Shih-Lun Chen, Liang-Hung Wang, Jia-Ching Wang, Patricia Angela R. Abu
Robust Non-Invasive Cardiac Index Prediction Via Feature Integration And Data-Augmented Neural Networks, Chih-Hao Chang, Mei-Ling Chan, Yu-Hung Fang, Po-Lin Huang, Tsung-Yi Chen, Tsun-Kuang Chi, I Elizabeth Cha, Tzong-Rong Ger, Kuo-Chen Li, Shih-Lun Chen, Liang-Hung Wang, Jia-Ching Wang, Patricia Angela R. Abu
Department of Information Systems & Computer Science Faculty Publications
Concurrent with the rising consumption of ultra-processed, high-calorie diets and the decline in physical activity, obesity and related cardiovascular conditions among young adults have continued to increase, becoming an important global public health concern. This study integrates non-invasive Internet of Things (IoT) sensing devices, including the TERUMO ES-P2000 blood pressure monitor (Terumo Corp., Tokyo, Japan) and the PhysioFlow PF07 Enduro cardiac hemodynamic analyzer (Manatec Biomedical, Poissy, France), with an artificial neural network (ANN) for cardiac index (CI) prediction. Through appropriate data preprocessing and model training strategies, the generalization ability and stability of the proposed CI prediction model were significantly enhanced. …
Evaluation Of An Affordable Prosthetic Liner In Resource Limited Settings, Samerial Brown
Evaluation Of An Affordable Prosthetic Liner In Resource Limited Settings, Samerial Brown
Posters - 2026
The lower limb prosthesis is an important assistive technology for persons with limb amputations and differences. The interface (prosthetic liner) between the rigid prosthetic socket and the residual limb is often made of silicone, urethane or thermoplastic elastomer gel. This material provides cushioning and support as well as suspension for the transtibial (below knee) prosthetic leg. Unfortunately the cost of liners range from $3-$600. This cost precludes its use in resource limited settings such as Sri Lanka. As a result patients are fit with a foam liner which has less cushioning and suspension capabilities than a gel type liner. This …
Development Of An Automated Platform For Cell Biology Experiments, Dipendra Nepal
Development Of An Automated Platform For Cell Biology Experiments, Dipendra Nepal
Shelby Hall Graduate Research Forum Posters
Cell biology experiments involve repetitive tasks such as pipetting, sample preparation, and imaging, which are typically performed manually. These manual processes can introduce variability, reduce efficiency, and increase the cost of biomedical research. To address these challenges, our lab is developing a modular robotic platform, iEye™, to automate key steps in cell biology workflows [1]. The system is designed as self-contained modules, allowing flexible development and integration of different functionalities. In this work, we focus on a sample preparation module that integrates a 6-degree-of-freedom robotic arm, a motorized stage, and a pneumatic pipetter. This module is being developed to automate …
Orthopedic Bone Drill, Logan G. Schmid, Matthew T. Wold, May Geng
Orthopedic Bone Drill, Logan G. Schmid, Matthew T. Wold, May Geng
Biomedical Engineering
This project aims to design a bone drill for orthopedic procedures which alleviates the heat generated in the bone during drilling.
Volumetric Wear Analysis Of Polyethylene Orthopedic Liners Using Point Clouds, Gabriel Landi
Volumetric Wear Analysis Of Polyethylene Orthopedic Liners Using Point Clouds, Gabriel Landi
Dartmouth College Master’s Theses
In vivo wear of ultra-high molecular weight polyethylene (UHMWPE) orthopedic bearings represents a major problem in shoulder and knee arthroplasty, with significant amounts of devices failing due to the complication itself, and even more due to associated reasons for retrieval, including aseptic loosening. However, quantification of UHMWPE wear has largely been limited to linear and in vitro volumetric analyses, obscuring the understanding of the amount of clinically relevant material loss. This study proposes new methods to measure articular, rim, and backside surfaces of retrieved shoulder and knee UHMWPE liners, centered around the coordinate measuring machine (CMM)-based collection of high density …
Mxene-Enabled Wearable Biosensors: A Design Framework For Autonomous Biosensing, Jegan Rajendran, Gymama Slaughter
Mxene-Enabled Wearable Biosensors: A Design Framework For Autonomous Biosensing, Jegan Rajendran, Gymama Slaughter
Center for Bioelectronics Publications
MXenes, a rapidly expanding family of two-dimensional transition metal carbides and nitrides, have emerged as leading materials for wearable bioelectronics due to their metallic conductivity, termination-rich surfaces, mechanical compliance, and tunable interlayer structures. However, wearable biosensor performance does not arise from conductivity alone, but from coupled interactions among surface termination chemistry, heterointerface engineering, hierarchical architecture, and device integration under dynamic physiological conditions. This review establishes a predictive structure-interface-device framework linking MXene chemistry to system-level performance across electrochemical, mechanical, gas, optical, and energy-storage modalities. We analyze how termination-controlled adsorption governs charge transfer and selectivity, how heterojunction formation modulates carrier density and …
Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao
Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
Aim: This study investigates the feasibility of using radial and carotid arterial pulse signals to assess cardiovascular (CV) function at rest and during post-exercise recovery in a heart transplant (HTx) patient. Method: Two micro-fabricated tactile sensors were used to simultaneously acquire arterial pulse signals at the radial artery (RA) and carotid artery (CA). Measurements were taken at rest and at multiple time points post-exercise on three subjects: an HTx patient, a percutaneous coronary intervention (PCI; coronary stent) patient and a healthy control. An SDOF-TF-based time-frequency analysis algorithm was applied to extract a comprehensive set of CV parameters, including heart rate …
Preventing G-J Tube Dislodgement - A Device And Communication Innovation, Sarah Clark
Preventing G-J Tube Dislodgement - A Device And Communication Innovation, Sarah Clark
2026
Abstract
The Problem: G/J tube dislodgement is a frequent complication in pediatric patients.
Leads to:
- Emergency department visits
- Hospital admissions
- Delays in nutrition/medication
Impact on Patients & Families:
- IV placement (traumatic)
- Radiation exposure
- Overnight hospital stays
Impact on Nurses & System:
- Increased workload (admissions, coordination)
- Occupied inpatient beds for stable patients
- Inefficient care processes
Aims/Objectives Aim: Reduce unplanned G/J tube dislodgements and related hospital utilization.
Objectives: Develop a breakaway connector prototype
Implementation and Evaluation:
Setting: Pediatric inpatient & outpatient system
Participants: Nurses (bedside, GI, IR), caregiver, innovation team
Process: Roundtable discussions → identified workflow gaps Communication/workflow audit Developed …
A Chicken Model For Non-Invasive Diagnosis Of Infant Developmental Dysplasia Of The Hip (Ddh) Using Acoustic Transmission Measurements, Aliza Shah
Honors Undergraduate Theses
Developmental dysplasia of the hip (DDH) is a condition characterized by abnormal development and stability of the hip joint. In a healthy infant, the femoral head (ball) fits securely within the acetabulum (socket of the pelvis), allowing for proper joint function. In DDH, the relationship is disrupted, ranging from mild acetabular dysplasia to partial (subluxation) or complete dislocation of the femoral head. This condition represents a range of structural abnormalities that develop during early growth. The integrity of the hip joint is essential for physical mobility, and disruption of this structure can lead to significant functional impairment. DDH may result …
Preventing G/J Tube Dislodgement: A Device And Communication Innovation, Sarah Clark
Preventing G/J Tube Dislodgement: A Device And Communication Innovation, Sarah Clark
2026
The Problem
G/J tube dislodgement is a frequent complication in pediatric patients
Leads to:
- Emergency department visits
- Hospital admissions
- Delays in nutrition/medication
Impact on Patients & Families:
- IV placement (traumatic)
- Radiation exposure
- Overnight hospital stays
Impact on Nurses & System:
- Increased workload (admissions, coordination)
- Occupied inpatient beds for stable patients
- Inefficient care processes
Aims/Objectives
Aim: Reduce unplanned G/J tube dislodgements and related hospital utilization.
Objectives: Develop a breakaway connector prototype
Implementation and Evaluation
Setting: Pediatric inpatient & outpatient system
Participants: Nurses (bedside, GI, IR), caregiver, innovation team
Process:
Roundtable discussions → identified workflow gaps
Communication/workflow audit
Developed device …
Synthesis And Study Of Stable Organic Radicals For Mri Contrast Agents And New Materials, Sabina Dhakal
Synthesis And Study Of Stable Organic Radicals For Mri Contrast Agents And New Materials, Sabina Dhakal
Dissertations and Doctoral Documents, University of Nebraska-Lincoln, 2023–
The first part of this dissertation focuses on the design, synthesis, and characterization of a thermally robust S =1/2 phototetrazolinyl monoradical and the development of synthetic methodologies for a high-spin (S = 1) phototetrazolinyl diradical. Electrochemical studies of the phototetrazolium cation (precursor to the monoradical) revealed a remarkably narrow electrochemical band gap (Ecell ≈ 0.82 V), suggesting promising electrical conductivity. Thermal analysis of the monoradical demonstrated excellent stability, with the onset of decomposition at 232 °C. Building on the excellent thermal stability and promising properties for electrical conductivity of the monoradical, we developed two condensation-based synthetic routes that provide viable …
Comparative Assessment Of Lower Limb Neuromusculoskeletal Activation And Joint Kinematics In Normal And Impaired Gait, Jack Ryan Schule
Comparative Assessment Of Lower Limb Neuromusculoskeletal Activation And Joint Kinematics In Normal And Impaired Gait, Jack Ryan Schule
Theses and Dissertations
This thesis evaluates whether accessible and affordable technologies can provide clinically significant, quantifiable gait analysis comparable to traditional marker-based motion capture systems. Modern high-end systems offer excellent accuracy but remain financially and logistically inaccessible to many clinicians and researchers. To address this gap, a framework was developed using markerless pose estimation using the model, MediaPipe, inertial measurement units (IMUs) processed through an Extended Kalman Filter (EKF), and surface electromyography (sEMG) to measure joint kinematics and neuromuscular activity during gait. An experiment was performed where data was collected from participants with both normal gait and pathologies including: Osgood–Schlatter disease, Plica Band …
Development Of A Non-Faradaic Impedimetric Biosensor Based On Reduced Graphene Oxide For The Detection Of Brain-Derived Neurotrophic Factor (Bdnf), Mariana N. Martins
Development Of A Non-Faradaic Impedimetric Biosensor Based On Reduced Graphene Oxide For The Detection Of Brain-Derived Neurotrophic Factor (Bdnf), Mariana N. Martins
Electronic Theses and Dissertations
Neurological disorders affect millions of people worldwide. In the case of Alzheimer’s disease (AD), the rising number of cases significantly increases global healthcare costs. Therefore, early detection of biomarkers at the onset of the disease is essential for early diagnosis. This study presents an electrochemical biosensor designed for the detection of Brain-Derived Neurotrophic Factor (BDNF) in human plasma, incorporating reduced graphene oxide (rGO) to enhance signal sensitivity. Dielectrophoresis (DEP) was employed to deposit rGO flakes on the electrode surface, improving conductivity and sensor performance. Electrochemical impedance spectroscopy (EIS) was used to monitor changes in impedance associated with BDNF binding events, …
Novel Percutaneous Repair Of Femoral Pseudoaneurysms Using Perclose Proglide™: A Case Series, Ryan Mancoll, Emily Burnett, Nicholas Bandy, Benjamin Samberg, Thomas Cook, Jacob Hoffman, Christopher Murter, Matthew Rossi, David Dexter, Hosam El Sayed, Animesh Rathore Md
Novel Percutaneous Repair Of Femoral Pseudoaneurysms Using Perclose Proglide™: A Case Series, Ryan Mancoll, Emily Burnett, Nicholas Bandy, Benjamin Samberg, Thomas Cook, Jacob Hoffman, Christopher Murter, Matthew Rossi, David Dexter, Hosam El Sayed, Animesh Rathore Md
Cardiovascular Research Symposium
BACKGROUND - This case series details the novel use of the Perclose ProGlide closure device to successfully repair three separate cases of iatrogenic femoral pseudoaneurysms (PSAs) without attempting other modalities first. Conventional treatment methods of ultrasound-guided compression, duplex-directed thrombin injection (DDTI), or open surgical repair were contraindicated in these patients due to unique anatomy or advanced comorbidities.
METHODS – Details were gathered via a retrospective chart review.
RESULTS - In the first case, a 73-year-old female had an access site PSA off the superficial femoral artery (SFA) with concomitant arteriovenous fistula (AVF) and advanced cardiac disease. The ProGlide device was …
Vibration-Based Detection For The Monitoring Of Neonatal Bcpap Respiratory Support To Minimize Duration Of Disconnections, Kaitlyn G. Calabresi, Meera R. Bhat, Lavinia L. Kong, Eli J. Foster, Jonathan Wang, Sangeeta Koilada, Angela Mak, Aastha Kapadia, Niam Mohseni, W. Keith Leung, Suneetha Desiraju, Constanza Miranda
Vibration-Based Detection For The Monitoring Of Neonatal Bcpap Respiratory Support To Minimize Duration Of Disconnections, Kaitlyn G. Calabresi, Meera R. Bhat, Lavinia L. Kong, Eli J. Foster, Jonathan Wang, Sangeeta Koilada, Angela Mak, Aastha Kapadia, Niam Mohseni, W. Keith Leung, Suneetha Desiraju, Constanza Miranda
School of Medicine Faculty Publications
Bubble continuous positive airway pressure (bCPAP) is a minimally invasive respiratory support for neonates experiencing respiratory distress syndrome (RDS). It exerts continuous, oscillatory air pressure to encourage lung function and development. Neonates’ movement may cause disconnections at the nasal interface. These disconnections are characterized by the cessation of bubbling at the bCPAP respiratory circuit output and frequently go unnoticed until hypoxia develops. Common Neonatal Intensive Care Unit (NICU) bCPAP systems lack a built-in alarm or accessory device to monitor for disconnections. As a result, nursing personnel must exercise extreme caution utilizing current bCPAP procedure. If a neonate is disconnected, it …
Exploring The Effect Of Led-To-Photodetector Spacing On Subcutaneous Photoplethysmography For Continuous Blood Pressure Measurement, Dario Cabal, Brian Nguyen, David B. Green, Kevin Kilgore, Varun Thakkar, Michael J. Fu, Steve J. Majerus
Exploring The Effect Of Led-To-Photodetector Spacing On Subcutaneous Photoplethysmography For Continuous Blood Pressure Measurement, Dario Cabal, Brian Nguyen, David B. Green, Kevin Kilgore, Varun Thakkar, Michael J. Fu, Steve J. Majerus
Student Scholarship
Photoplethysmography (PPG) is widely used to measure heart rate, blood oxygenation, and more recently, blood pressure. Implanted PPG systems offer the possibility to measure similar real-time measures of cardiovascular health, however, the detection method may vary due to a lack of capillary vessels for PPG sensors to observe in muscle tissue. To improve volumetric blood detection in large muscles, without relying on the capillary density of skin, a flexible PPG sensor was developed. The sensor included multiple spacing of illuminating infrared (IR) light emitting diodes (LEDs) and a single IR photodetector. This arrangement was expected to enable detection of blood …
Acoustic And Hemodynamic Analysis Of Phantoms: Roughness And Flow Dynamics, Ethan Erik Olof Sundberg
Acoustic And Hemodynamic Analysis Of Phantoms: Roughness And Flow Dynamics, Ethan Erik Olof Sundberg
Master's Theses
The purpose of this study was to determine whether different vascular phantoms, with and without a surrogate arm, could serve as effective analogs to the human brachial artery for assessing endothelial dysfunction, an early indicator of cardiovascular disease, particularly atherosclerosis. Atherosclerosis is characterized by plaque buildup and endothelial damage, which precede more severe clinical events and are often detectable through changes in vascular function. A 40” water tower was used to simulate diastolic pressure, enabling water flow through each phantom. Strain gauge pressure transducers were placed at both ends of the phantoms to measure pressure drop, while a microphone captured …
Development Of A Light-Based Platform To Assess Cervical Mucus Barrier Function And Physical Mucus Properties, Elizabeth J. Buzbee
Development Of A Light-Based Platform To Assess Cervical Mucus Barrier Function And Physical Mucus Properties, Elizabeth J. Buzbee
McKelvey School of Engineering Graduate Student Theses & Dissertations
Preterm birth is the leading cause of neonatal morbidity and mortality worldwide, yet current clinical tools for predicting its risk lack specificity and reliability. Cervical mucus plays a crucial role in maintaining pregnancy by forming a barrier that protects the uterus against infection. This study investigates the use of laser speckle rheology as a noninvasive technique to assess cervical mucus biomechanics. Synthetic cervical mucus was fabricated at varying hydration levels and tested using a conventional rheometer that confirmed that the mechanical properties of the synthetic mucus samples were representative of physiological cervical mucus. These results were compared to the complex …