Articles 1 - 30 of 37

Full-Text Articles in Biomedical Devices and Instrumentation

Effect Of Extracellular Matrix (Ecm) Protein Micropatterns On The Behavior Of Human Neuroblastoma Cells, Ishwari Poudel Dec 2011

Effect Of Extracellular Matrix (Ecm) Protein Micropatterns On The Behavior Of Human Neuroblastoma Cells, Ishwari Poudel

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

Recent advances in patterning techniques and emerging surface microtechnologies have allowed cell micropatterning to control spatial location of the cells on a surface as well as cell shape, attachment area, and number of contacting neighbor cells. These parameters play important roles in cell cellular behaviors. Cell micropatterning has thus become one of the most important strategies for biomedical applications, such as, tissue engineering, diagnostic immunoassays, lab-on-chip devices, bio-sensing, etc., and cell biology studies as well. For neuronal cells, there have been attempts to distribute neuronal cells on specific patterns to control cell-to-cell interaction. However, there have been very limited understanding …


Impedance-Based Detection Of Tissue Using A Multi-Electrode Device, Shane Killian Fleshman Dec 2011

Impedance-Based Detection Of Tissue Using A Multi-Electrode Device, Shane Killian Fleshman

Master's Theses

Melanoma skin cancer is the abnormal growth of the melanocytes – the pigmented cells located in the epidermis. The current gold standard diagnostic technique for determining whether a lesion is cancerous involves subjectively examining suspicious lesions and performing an invasive biopsy to confirm melanoma. This method may neglect some lesions or cause scarring from biopsies that turn out to be benign. Thus, impedance-based detection using a multi-electrode device was investigated as a noninvasive technique to diagnose melanoma skin cancer. The multi-electrode device was designed with 8 equally spaced Ag/AgCl electrodes surrounding one central electrode at a 5 mm radius. The …


Comparison Of Microwave And Conventionally Sintered Yttria-Doped Zirconia Ceramics, Colin J. Reidy, Thomas J. Fleming, Stuart Hampshire, Mark R. Towler Nov 2011

Comparison Of Microwave And Conventionally Sintered Yttria-Doped Zirconia Ceramics, Colin J. Reidy, Thomas J. Fleming, Stuart Hampshire, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

This paper reports on improvement of the physical and mechanical properties of Y2O3-ZrO2 ceramics through compositional optimization, the use of nanograined powders and utilization of microwave sintering. ZrO2 with 2-5 mol% Y2O3, prepared from nanopowders, was sintered in both conventional and microwave furnaces under exactly the same heating schedule. It was found that microwave sintering improves physical and mechanical properties of Y2O3-ZrO2 ceramics compared with conventional sintering. Compositions containing 2 mol% Y2O3 exhibit the greatest improvement due to retention of tetragonal ZrO …


Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz Aug 2011

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz

Master's Theses

ICSI (intra-cytoplasmic sperm injection) has attracted research interest from both biological and engineering groups. The technology is constantly evolving to perform this procedure with precision and speed. One such development is the contribution of this thesis. We focus on a relatively recent procedure called Ros-Drill© (rotationally oscillating drill), of which the early versions have already been effectively utilized for the mice. In the first part, we present a procedure to automate a critical part of the operation: initiation of the rotational oscillation, Visual feedback is used to track the pipette tip. Predetermined species-specific penetration depth is successfully utilized …


Sol-Gel Derived Silver-Incorporated Titania Thin Films On Glass: Bactericidal And Photocatalytic Activity, Betul Akkopru Akgun, Anthony W. Wren, Caner Durucan, Mark R. Towler, Nathan P. Mellott Aug 2011

Sol-Gel Derived Silver-Incorporated Titania Thin Films On Glass: Bactericidal And Photocatalytic Activity, Betul Akkopru Akgun, Anthony W. Wren, Caner Durucan, Mark R. Towler, Nathan P. Mellott

Chemical and Biochemical Engineering Faculty Research & Creative Works

Titanium dioxide (TiO2) and silver-containing TiO2 (Ag-TiO2) thin films were prepared on silica pre-coated float glass substrates by a sol-gel spin coating method. The bactericidal activity of the films was determined against Staphylococcus epidermidis under natural and ultraviolet (UV) illumination by four complementary methods; (1) the disk diffusion assay, (2) UV-induced bactericidal test, (3) qualitative Ag ion release in bacteria inoculated agar media and (4) surface topographical examination by laserscan profilometry. Photocatalytic activity of the films was measured through the degradation of stearic acid under UV, solar and visible light conditions. The chemical state and …


Clinical Risk Factors For Osteoporosis In Ireland And The Uk: A Comparison Of Frax And Qfracturescores, N. M. Cummins, E. K. Poku, Mark R. Towler, O. M. O'Driscoll, S. H. Ralston Aug 2011

Clinical Risk Factors For Osteoporosis In Ireland And The Uk: A Comparison Of Frax And Qfracturescores, N. M. Cummins, E. K. Poku, Mark R. Towler, O. M. O'Driscoll, S. H. Ralston

Chemical and Biochemical Engineering Faculty Research & Creative Works

Recently two algorithms have become available to estimate the 10-year probability of fracture in patients suspected to have osteoporosis on the basis of clinical risk factors: the FRAX algorithm and QFractureScores algorithm (QFracture). The aim of this study was to compare the performance of these algorithms in a study of fracture patients and controls recruited from six centers in the United Kingdom and Ireland. A total of 246 postmenopausal women aged 50-85 years who had recently suffered a low-trauma fracture were enrolled and their characteristics were compared with 338 female controls who had never suffered a fracture. Femoral bone mineral …


A Silicon Nanoparticle-Based Polymeric Nano-Composite Material For Glucose Sensing, Qiang Liu, Munir H. Nayfeh, Siu-Tung Yau Jul 2011

A Silicon Nanoparticle-Based Polymeric Nano-Composite Material For Glucose Sensing, Qiang Liu, Munir H. Nayfeh, Siu-Tung Yau

Electrical and Computer Engineering Faculty Publications

A novel non-enzyme glucose sensing material has been prepared by incorporating ultrasmall (1–3 nm) silicon nanoparticles in polyaniline, a conducting polymer, as a nano-composite material (NCM). When deposited on electrodes, the composite material with three-dimensional loading of the nanoparticles showed a significantly enhanced amperometric response to glucose, compared to the nanoparticles deposited on bare electrodes and electrodes immobilized with the enzyme, glucose oxidase. The linear range of the glucose response of NCM electrodes covered both the hypo- and hyper-glycaemic glucose levels. The sensitivity of the NCM electrodes was 2.5 μA cm−2 mM−1. The NCM electrodes’ selectivity for …


Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni Jul 2011

Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni

Electrical & Computer Engineering Theses & Dissertations

The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …


Comparing Fbg And Pcf Force Sensors In A Laparoscopic Smart Surgical Scissor Instrument, Dean Callaghan, Ginu Rajan, Mark Mcgrath, Eugene Coyle, Yuliya Semenova, Gerald Farrell Jun 2011

Comparing Fbg And Pcf Force Sensors In A Laparoscopic Smart Surgical Scissor Instrument, Dean Callaghan, Ginu Rajan, Mark Mcgrath, Eugene Coyle, Yuliya Semenova, Gerald Farrell

Conference Papers

This paper presents a sensorized laparoscopic surgical scissor instrument using both a fiber Bragg grating (FBG) and a tapered photonic crystal fiber (PCF) as force sensors. The sensors are located on the blades for the detection of interaction forces generated between the instrument and tissue during cutting. The force sensitivity of each sensorized blade is examined. Results show that the scissor blade-PCF sensor arrangement outperforms the blade with the FBG during static loading calibration experimentation. Moreover, experiments show that the PCF based arrangement is less sensitive to temperature effects than its FBG counterpart. This negates the need for additional temperature …


The Effect Of Adding Organic Polymers To Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. Coughlan, N. M. Cummins, A. W. Wren, Mark R. Towler Jun 2011

The Effect Of Adding Organic Polymers To Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. Coughlan, N. M. Cummins, A. W. Wren, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

To conclude, the addition of polymers to GPCs resulted in little change to the Tw and Ts, however the compressive strength was found to decrease slightly. ASAP tests revealed that the cements may undergo some structural changes as a result of these additions. In the future perhaps the addition of organic polymers suspended in the liquid phase as part of the cement may yield improved results in this type of study. © 2011 IEEE.


Aluminium-Free Glass Polyalkenoate Spinal Cements, A. W. Wren, N. M. Cummins, Mark R. Towler Jun 2011

Aluminium-Free Glass Polyalkenoate Spinal Cements, A. W. Wren, N. M. Cummins, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Addition of Yitanium increased the Wt & St and the sf strength of these cements compared to the control (BT 101). © 2011 IEEE.


Detection Of Breathing And Infant Sleep Apnea, Brian Berg Jun 2011

Detection Of Breathing And Infant Sleep Apnea, Brian Berg

Computer Engineering

Sleep apnea is a condition where people pause while breathing in their sleep; this can be of great concern for infants and premature babies. Current monitoring systems either require physical attachment to a user or may be unreliable. This project is meant to develop a device that can accurately detect breathing through sound and issue appropriate warnings upon its cessation. The device produced is meant to be a standalone device and thus was developed as an embedded systems project on a Xilinx Spartan 6 FPGA.


A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell Jun 2011

A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell

Master's Theses

This project encompasses the design and development of a pretreatment microfluidic device for samples of physiological conductivity, namely a saline solution. The conductivity was reduced through the combination of dilution and ion removal using electric fields to enable downstream electro kinetic manipulations. The two major parts of this project include (1) designing a pretreatment protocol to reduce the conductivity of the sample solution to an acceptable level and (2) designing /fabricating a microchip that will effectively allow aim (1) to be performed on chip.

This project is one of the first to observe the effects of an electric field, used …


Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett Jun 2011

Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett

Master's Theses

Development of an Open Source Prosthetic Hand Platform

Scott Garrett

In the field of upper extremity prosthetic devices, advancements in technology drive the design of products which are becoming capable of restoring the lost functions of the native hand. While several dexterous devices have been developed to serve this purpose, they remain prohibitively expensive and thus are not a viable option for many upper extremity amputees. To address this problem a prosthetic hand platform was developed utilizing the open source Arduino microcontroller and off-the-shelf electrical components. Using these resources, a novel finger actuation mechanism was developed to show how …


Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus Jun 2011

Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus

Electrical Engineering

No abstract provided.


An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey Jun 2011

An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey

Biomedical Engineering

Microfluidic devices are diagnostic tools that are small, portable, and inexpensive. This makes them ideally suited for resource-limited settings. To construct a 3D device, each layer of patterned paper is stacked using double-sided tape with holes corresponding to the pattern. It is necessary to have a paste to fill the holes in the tape and provide a medium for the fluid to wick through. The powder used to make the paste is very expensive and must be bought in bulk (an estimated $1121 - $1231), so it is not convenient for the Biomedical (BMED) department to use. This project was …


Control System For Mass Spectrometer, Jian Xu May 2011

Control System For Mass Spectrometer, Jian Xu

Purdue Polytechnic Masters Theses

Mass spectrometry (MS) is a very popular analytical methodology that measures the mass of ions using a mass spectrometer. It is widely used for determining masses of chemicals, the elemental composition of a sample and molecule structure. The process of mass spectrometry normally consists of ionizing chemical compounds to ions and measuring their ratios of mass to charge for analysis.

MS instruments consist of three modules: Ionization, Analysis and detection. A LabVIEW system was developed to control the three modules of a mass spectrometer, giving the required signals in a right sequence. Experiments can be carried out by using the …


Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri May 2011

Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri

Master's Theses

The development, progression, and treatment of degenerative musculoskeletal diseases, such as carpal tunnel and shoulder impingement syndromes, may be better characterized when joint motions are assessed over long durations outside clinical, laboratory, or rehabilitation settings that involve standardized assessment, exercise protocols, and/or regimented movements. Assessment methods for human movement capture beyond laboratory or clinical experiments are typically limited to short capture times of less than one hour. Noninvasive, long-duration measurements of joint motion in occupational settings provides more insight into movement patterns and quantitative assessments regarding joint usage, which lead to a better understanding of the cumulative effects associated with …


A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman May 2011

A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman

Master's Theses

Hemoglobin can be measured on a variety of devices using different principles of operation. Noninvasive pulse CO-oximetry represents the latest development in hemoglobin measuring technology. The technology uses principles similar to pulse oximetry to measure total hemoglobin, oxyhemoglobin, reduced oxyhemoglobin, carboxyhemoglobin and methemoglobin. Similar to the introduction of pulse oximetry to the medical field, pulse CO-oximetry has been met with skepticism. Since the technology is noninvasive and provides continuous monitoring in comparison to invasive and discrete techniques used in other methods, CO-oximetry purportedly provides an advantage in patient care. The purpose of this research is threefold: (a) to review the …


Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette May 2011

Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette

Master's Theses

In today’s healthcare environment, networking of medical devices is becoming more and more prevalent. There is an increasing need for mobile technology to meet clinical needs. Wireless communication is essential for allowing medical devices to be able to move with the patient, while continuing to record and communicate patient data. A traditional example is telemetry monitoring, but other examples of wireless utilization include sending ECG test results to the EMR or remotely updating the drug library on numerous IV pumps. Each wireless application has varying demands on the connectivity infrastructure and will share radio frequency (RF) spectrum resources with a …


Construction And Use Of A Direct Calorimeter To Estimate Energy Expenditure In Hibernators, Mark S. Burger, Frank Van Breukelen Apr 2011

Construction And Use Of A Direct Calorimeter To Estimate Energy Expenditure In Hibernators, Mark S. Burger, Frank Van Breukelen

Festival of Communities: UG Symposium (Posters)

Metabolic rates have traditionally been estimated through indirect calorimetry (gas exchange or respirometry) due to its ease and availability. Oxygen consumption neglects the contributions of anaerobic metabolism, while direct calorimetry (heat production) estimates both anaerobic and aerobic metabolism. Walsberg and Hoffman (2005) report anaerobic metabolism may be more important to small rodents than was previously thought. During the non-steady state of mammalian hibernation, we hypothesize that anaerobic processes may play an even greater role in fueling metabolism. To address this question, we constructed a very sensitive calorimeter that utilizes the Seebeck effect from a thermoelectric element (Peltier device). We describe …


Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler Apr 2011

Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Gas emboli are a clinical issue often encountered in the space exploration, marine construction, and medical fields.  Individuals involved with these disciplines will often have asympomatic gas emboli circulating throughout their bodies on a regular basis.  A study into the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis in humans is thus presented.  This research utilized a custom built cardiovascular flow simulator and accompanying data acquisition system to experimentally determine the influence of gas emboli under varied circumstances on the mean wall shear stress of a tube in-vitro.  A directly inverse relationship between gas embolus presence in …


Leaching Of Potential Hazardous Elements Of Coal Cleaning Rejects, Luis F.O. Silva, Maria Izquierdo, Xavier Querol, Robert B. Finkelman, Marcos L.S. Oliveira, Marcus Wollenschlager, Mark R. Towler, Rafael Pérez-López, Felipe Macias Apr 2011

Leaching Of Potential Hazardous Elements Of Coal Cleaning Rejects, Luis F.O. Silva, Maria Izquierdo, Xavier Querol, Robert B. Finkelman, Marcos L.S. Oliveira, Marcus Wollenschlager, Mark R. Towler, Rafael Pérez-López, Felipe Macias

Chemical and Biochemical Engineering Faculty Research & Creative Works

The geochemical characteristics of coal cleaning rejects (CCR) in Santa Catarina State, Brazil, were investigated. Around 3.5 million ton/ year of coal waste are dumped in Santa Catarina State. Coal beneficiation by froth flotation results in large amounts of CCR composed of coaly and mineral matter, the latter characterized by the occurrence of sulphide minerals and a broad array of leachable elements. The total and leachable contents of more than 60 elements were analyzed. Atmospheric exposure promotes sulphide oxidation that releases substantial sulphate loads as well as Ca2+, K+, Mg2+, Cl- and Al3+ …


Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do Mar 2011

Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do

Master's Theses

During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process.  In addition, some applications of UEP are incorporated into the official releases of the device product.  UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD).  This thesis covers the flexible and reusable …


Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel Feb 2011

Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel

Master's Theses

As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.

Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …


The Structural Role Of Titanium In Ca-Sr-Zn-Si/Ti Glasses For Medical Applications, A. W. Wren, F. R. Laffir, A. Kidari, Mark R. Towler Feb 2011

The Structural Role Of Titanium In Ca-Sr-Zn-Si/Ti Glasses For Medical Applications, A. W. Wren, F. R. Laffir, A. Kidari, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Glasses for medical applications are used in particulate form or as a cement component. This work was undertaken to determine structural changes in 0.48SiO2-0.36ZnO-0.12CaO-0.04SrO glass when the SiO2 is substituted with 5 mol% increments of TiO2. X-ray Diffraction (XRD) was used to determine the presence of crystallinity. This occurred after additions of 20 mol% TiO2. Differential Thermal Analysis (DTA) and Network connectivity (NC) calculations determined that by increasing the TiO2 content, the Tg and NC reduced (Tg 670 °C to 632 °C, NC 1.83 to -1.14) suggesting that TiO2 acts as …


Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre Feb 2011

Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre

Master's Theses

This thesis encompasses a feasibility study of using low-cost materials to manufacture microfluidic chips that can perform the same functions as chips manufactured using traditional methods within an acceptable range of efficiency of chips created with more exotic methods and materials. The major parts of the project are the selection and characterization of the fabrication methods for creating the channels for fluid flow, the methods for sealing the channels to create a usable chip and the electrophoretic separations of carboxylated microspheres of different potentials. In this work we seek to answer the question if laser-etched PMMA microfluidic chips are comparable …


Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle Jan 2011

Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …