Healthy Aging In Place: An Integrated Smart Home Using Alexa-Compatible Technology, Tyler Kryst May 2021

Healthy Aging In Place: An Integrated Smart Home Using Alexa-Compatible Technology, Tyler Kryst

UNLV Theses, Dissertations, Professional Papers, and Capstones

The purpose of this research was to address current healthcare concerns among the aging population. Around the globe, the average life expectancy is projected to continue increasing resulting in a higher prevalence of age-related disease. With the ever-increasing capabilities of modern technology, it is necessary to apply this technology to increase the health and safety of older adults. This work had three objectives. The first objective was the establishment of an integrated smart home aimed at creating a healthy aging-in-place environment through the use of Alexa. The second objective was the development and integration of a completely custom health device …


Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney Mar 2020

Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney

Biomedical Engineering

This project report provides detailed information on designing and building a DIY Incubator. The device is indicated for growing and maintaining BSL-1 mammalian or bacterial cell culture with a temperature control in the range of 25-45°C ± 1°C. The device is made fully programmable via an Arduino, and is structurally designed to fit two T75 cell culture flasks at a time. The device is able to return to a specified temperature set point within 10 minutes and maintains 5% CO2 partial pressure conditions. The incubator has a small physical footprint, with an overall dimension of 22in x 16in x 15.5in …


Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin Jul 2019

Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin

Honors Projects

A 3D printed hand and arm prosthetic was created from the idea of adding bionic elements while keeping the cost low. It was designed based on existing models, desired functions, and materials available. A tilt sensor keeps the hand level, two motors move the wrist in two different directions, a limit switch signals the fingers to open and close, and another motor helps open and close the fingers. All sensors and motors were built on a circuit board, programmed using an Arduino, and powered by a battery. Other supporting materials include metal brackets, screws, guitar strings, elastic bands, small clamps, …


Neurostimulator With Waveforms Inspired By Nature For Wearable Electro-Acupuncture, Jose Aquiles Parodi Amaya Jun 2019

Neurostimulator With Waveforms Inspired By Nature For Wearable Electro-Acupuncture, Jose Aquiles Parodi Amaya

LSU Doctoral Dissertations

The work presented here has 3 goals: establish the need for novel neurostimulation waveform solutions through a literature review, develop a neurostimulation pulse generator, and verify the operation of the device for neurostimulation applications.

The literature review discusses the importance of stimulation waveforms on the outcomes of neurostimulation, and proposes new directions for neurostimulation research that would help in improving the reproducibility and comparability between studies.

The pulse generator circuit is then described that generates signals inspired by the shape of excitatory or inhibitory post-synaptic potentials (EPSP, IPSP). The circuit analytical equations are presented, and the effects of the circuit …


A Bioinstrumentation Active Learning Educational Module: The Design Of A Working Temperature Sensor Using A Ntc Thermistor, Baylor Bush May 2019

A Bioinstrumentation Active Learning Educational Module: The Design Of A Working Temperature Sensor Using A Ntc Thermistor, Baylor Bush

Biomedical Engineering Undergraduate Honors Theses

The Department of Biomedical Engineering at the University of Arkansas has continued to develop over the years, with more students enrolling in the program each year. Within the first biomedical engineering course, Introduction to Biomedical Engineering, various topics are introduced to students, and the topic of bioinstrumentation has been one of the most complex and difficult topics for students to comprehend through just a few lectures. In order to aid students in grasping these intricate concepts, an active learning module was developed in which students can work in groups to build a simple thermistor circuit as a temperature sensor. The …


Hydroband: The Continuous Hydration Monitoring System, Karina E. Atkinson, Catherine P. Benedict Jan 2016

Hydroband: The Continuous Hydration Monitoring System, Karina E. Atkinson, Catherine P. Benedict

Williams Honors College, Honors Research Projects

Dehydration is defined as a mild, moderate, or extreme loss of water in the body. It can result in fever, muscle cramps, headaches, dizziness, or heat stroke in athletes. Ways to determine hydration levels include analysis of the urine, blood, or sweat, body weight changes, skin elasticity tests, and increases in core temperature. Patent search, research journals, and outside studies in the health and fitness market showed that a convenient and continuous hydration monitoring system was not available. Changes in core body temperature proved to be the quickest way to measure hydration levels. The HydroBand system is geared towards athletes …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …