Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (10)
- Electrical and Computer Engineering (7)
- Mechanical Engineering (7)
- Biomedical (6)
- Bioimaging and Biomedical Optics (5)
-
- Medical Specialties (5)
- Other Biomedical Engineering and Bioengineering (5)
- Biomaterials (4)
- Biomechanical Engineering (4)
- Chemical Engineering (4)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (3)
- Biochemical and Biomolecular Engineering (3)
- Bioelectrical and Neuroengineering (3)
- Life Sciences (3)
- Surgical Procedures, Operative (3)
- Cardiology (2)
- Cell and Developmental Biology (2)
- Computer Engineering (2)
- Computer Sciences (2)
- Electrical and Electronics (2)
- Medical Biotechnology (2)
- Medical Sciences (2)
- Microbiology (2)
- Molecular, Cellular, and Tissue Engineering (2)
- Neurology (2)
- Physical Sciences and Mathematics (2)
- Psychiatry (2)
- Institution
-
- University of Nebraska - Lincoln (8)
- California Polytechnic State University, San Luis Obispo (6)
- Kettering University (5)
- Marquette University (5)
- University of Arkansas, Fayetteville (5)
-
- Missouri University of Science and Technology (3)
- University of Kentucky (3)
- University of Nevada, Las Vegas (3)
- Minnesota State University, Mankato (2)
- Purdue University (2)
- City University of New York (CUNY) (1)
- Cleveland State University (1)
- Syracuse University (1)
- The Texas Medical Center Library (1)
- University of Arkansas Little Rock (1)
- Virginia Commonwealth University (1)
- Western Michigan University (1)
- Keyword
-
- Artery (2)
- Fracture (2)
- Hypertension (2)
- Kinematics (2)
- Mechanical stimuli (2)
-
- Medical Devices (2)
- Remodeling (2)
- Tissue mechanics (2)
- Wall stress (2)
- 3D Printing (1)
- Accident prevention (1)
- Accidents (1)
- Activities of Daily Living (1)
- Actuators (1)
- Angle Stable (1)
- Aptamer (1)
- Articular joint replacements (1)
- Artificial Gravity (1)
- Artificial Implants (1)
- Artificial implants (1)
- Artificial muscle (1)
- Automated device (1)
- Avian Influenza Virus H5N1 (1)
- Beamforming Optimization (1)
- Biocompatible (1)
- Biodetection (1)
- Biomaterials (1)
- Biomechanics (1)
- Biomedical Imaging (1)
- Biomimetics (1)
- Publication
-
- Graduate Theses and Dissertations (5)
- Master's Theses (2009 -) (4)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (3)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (3)
- Master's Theses (3)
-
- Theses and Dissertations--Biomedical Engineering (3)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (3)
- Biomedical Engineering (2)
- Department of Mechanical and Materials Engineering: Faculty Publications (2)
- Journal of Undergraduate Research at Minnesota State University, Mankato (2)
- Mechanical Engineering Patents (2)
- Mechanical Engineering Publications (2)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (2)
- Theses and Dissertations (2)
- Chemical Engineering Patents (1)
- Computer Engineering (1)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (1)
- Department of Psychology: Faculty Publications (1)
- Dissertations (1934 -) (1)
- Dissertations and Theses (Open Access) (1)
- Honors Theses (1)
- Publications and Research (1)
- Renée Crown University Honors Thesis Projects - All (1)
- School of Computing: Conference and Workshop Papers (1)
- Undergraduate Research Posters 2014 (1)
- Publication Type
Articles 1 - 30 of 49
Full-Text Articles in Biomedical Devices and Instrumentation
Neural Network Based Emg Driven Modeling And Control Of Human Walking, Alaa Muheddin Abdulrahman
Neural Network Based Emg Driven Modeling And Control Of Human Walking, Alaa Muheddin Abdulrahman
Theses and Dissertations
Human body modeling (HBM) offers the benefit of replicating human activity into robotics and rehabilitation devices. Gait impairment is a consequence of several diseases like stroke, spinal cord injury, or Parkinson' disease. The modeling techniques developed in robotics have been used to improve gait abnormalities in walking and in building Exoskeletal robots. HBM is resource intensive as it requires setting-up laboratory facilities and using expensive instruments. Further, the data acquired is limited to the number of the participants. In addition, the accuracy of the model is important as it is related to human pathology. In this research, several Matlab based …
Processing And Mechanical Testing Of Strontium-Substituted Hydroxyapatite/Glass Composites, Chokchai Yatongchai, Mark R. Towler, Anthony W. Wren
Processing And Mechanical Testing Of Strontium-Substituted Hydroxyapatite/Glass Composites, Chokchai Yatongchai, Mark R. Towler, Anthony W. Wren
Chemical and Biochemical Engineering Faculty Research & Creative Works
Sr-HA/Glass composites were produced. Phase composition of composites was evaluated. Their physical and mechanical properties were determined. Sintered composites mainly consisted of Sr-HA/β-TCP, or β-TCP/Ca2ZnSi2O7. The composites had porosity up to 4 times those of undoped Sr-HA. Compared to undoped Sr-HA, the Sr-HA/Glass composites had lower biaxial flexural strength and hardness. The Weibull modulus for the composites ranged from 2.77 to 18.74.
A Portable Impedance Biosensing System Based On A Laptop With Labview For Rapid Detection Of Avian Influenza Virus, Yixiang Wang
A Portable Impedance Biosensing System Based On A Laptop With Labview For Rapid Detection Of Avian Influenza Virus, Yixiang Wang
Graduate Theses and Dissertations
Avian Influenza Virus (AIV) H5N1 is a highly pathogenic virus found not only in birds but also in human. Rapid and sensitive detection method is needed to help prevent the spread of AIV H5N1. In this study, a portable impedance biosensing system based on a laptop with LabVIEW software was developed for detection of AIV H5N1. First, a virtual instrument was programmed with LabVIEW software to form a platform for impedance measurement, data processing and control. The audio card of a laptop was used as a function generator while a data acquisition card was used with the signal channels for …
Development Of A Heart Rate Variability Measurement System Using Embedded Electronics, Naresh Kumar Velmurugan
Development Of A Heart Rate Variability Measurement System Using Embedded Electronics, Naresh Kumar Velmurugan
Graduate Theses and Dissertations
Recent advances in embedded electronics have a remarkable influence on the health care system. One of the most important applications is to monitor the health care of the patients at anytime and anyplace. In the last two decades, many researchers have focused mainly on heart rate variability (HRV) measurements. Patient's heart rate variability should be continuously monitored to help them in case of emergency. Under these circumstances, patients are required to have a HRV measuring kit for a constant observation.
The proposed project focuses on the development of a heart rate variability measurement system with the use of embedded electronics. …
Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder
Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder
UNLV Theses, Dissertations, Professional Papers, and Capstones
Actuators determine the performance of robotic systems at the most intimate of levels. As a result, much work has been done to assess the performance of different actuator systems. However, biomimetics has not previously been utilized as a pretext for tuning a series elastic actuator system with the purpose of designing an empirical testing platform. Thus, an artificial muscle tendon system has been developed in order to assess the performance of two distinct actuator types: (1) direct current electromagnetic motors and (2) ultrasonic rotary piezoelectric motors. Because the design of the system takes advantage of biomimetic operating principles such as …
Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young
Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young
UNLV Theses, Dissertations, Professional Papers, and Capstones
Mesenchymal stem cells are derived from a variety of human tissues and are being bioengineered and studied for possible uses in the advancement of medicine. Recent efforts are being focused on Dental Pulp Stem Cells (DPSC's) due to the accessibility of this tissue. Many factors influence DPSC quality and quantity, including the specific methods used to isolate, collect, concentrate, and store these isolates once they are removed. Ancillary factors, such as the choice of media, the selection of early versus late passage cells, and cryopreservation techniques may also influence the differentiation potential and proliferative capacity of DPSC isolates.
The objective …
Development Of A Novel Device For The Perfusion Driven Decellularization Of Skeletal Muscle, Benjamin Kasukonis
Development Of A Novel Device For The Perfusion Driven Decellularization Of Skeletal Muscle, Benjamin Kasukonis
Graduate Theses and Dissertations
Decellularization of skeletal muscle is a process that removes cellular components of skeletal muscle tissue while leaving behind the intact extracellular matrix (ECM). Skeletal muscle ECM is currently being studied as a biologic scaffold for repairing volumetric muscle loss (VML) because the removal of cells greatly reduces the antigenicity of the donor tissue. Decellularization usually relies on passive diffusion of detergents, surfactants and/or osmotic solutions to strip cells from the ECM. However, passive diffusion alone is usually not sufficient for complete removal of cells from the interior of large pieces of skeletal muscle using detergents, such as sodium dodecyl sulfate …
Wear Resistant And Biocompatible Coatings For Medical Devices And Method Of Fabrication, Mary Gilliam, Susan Farhat, Ali Zand
Wear Resistant And Biocompatible Coatings For Medical Devices And Method Of Fabrication, Mary Gilliam, Susan Farhat, Ali Zand
Chemical Engineering Patents
Abstract: A method of forming a biocompatible or biologically inert article for use in an application in which the article will make contact with at least one tissue, organ, or fluid within a human or animal body is provided. The method generally comprises providing an article having an external sur face; selecting chemical precursors; using a means to direct one or more chemical precursors towards or to apply such chemical precursors to the ex ternal surface; activating the chemical precursors by exposing said precursors to atmospheric pressure plasma; and grafting and/or cross-linking the chem ical precursors to form a solid …
Characterization Of Bone Material Properties And Microstructure In Osteogenesis Imperfecta/Brittle Bone Disease, John Robert Jameson
Characterization Of Bone Material Properties And Microstructure In Osteogenesis Imperfecta/Brittle Bone Disease, John Robert Jameson
Dissertations (1934 -)
Osteogenesis imperfecta (OI) is a genetic disorder primarily associated with mutations to type I collagen and resulting in mild to severe bone fragility. To date, there is very little data quantifying OI cortical bone mechanics. The purpose of this dissertation was to investigate bone microstructure, mineralization, and mechanical properties in adolescents with OI. Characterization studies were performed on small osteotomy specimens obtained from the extremities during routine corrective surgeries. Nanoindentation was used to examine the longitudinal elastic modulus and hardness at the material level for mild OI type I vs. severe OI type III. Both modulus and hardness were significantly …
Applications Of Novel Mri Technologies In Tissue Engineering And Disease Diagnosis, Vahid Khalilzad-Sharghi
Applications Of Novel Mri Technologies In Tissue Engineering And Disease Diagnosis, Vahid Khalilzad-Sharghi
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Magnetic resonance imaging (MRI) and magnetic resonance elastography (MRE) are increasingly under investigation to explore their potential role in establishing effective evaluation methods for the procedure of tissue regeneration carried out in vitro, in vivo, and in disease diagnosis. To this end, there is a continuous pursuit of novel tools both in vitro and in vivo. For instance, there is a great need for the development and evaluation of an MR-compatible incubation system that enables simultaneous monitoring and culturing of cell and tissue constructs using MRI techniques. Such an imagingcompatible incubation system eliminates exposing the culture to the risks of …
Kinematic Analysis Of The Glenohumeral Joint: A Comparison Of Post-Operative Rotator Cuff Repair Patients And Controls, Ryan Richard Inawat
Kinematic Analysis Of The Glenohumeral Joint: A Comparison Of Post-Operative Rotator Cuff Repair Patients And Controls, Ryan Richard Inawat
Master's Theses (2009 -)
Rotator cuff (RC) repair is a standard surgical intervention used to alleviate pain and loss of function in the shoulder due to torn RC tendons, involving re-attachment of the tendon to the humerus. Quantitative evaluation of kinematics following RC repair is possible with video motion analysis techniques, yet is rarely performed. With the purpose of quantifying the effects of RC repair, a Vicon 524 (Oxford, UK) motion analysis system was used to investigate three-dimensional (3D) kinematics of the glenohumeral (GH) joint and thorax following supraspinatus repair. A validated, 18 marker, inverse dynamics model based on ISB standards was applied to …
Apparatus And Method For Remote Assessment And Therapy Management In Medical Devices Via Interface Systems, Jeffrey Hargrove, Robert M. Ford, Thomas B. Johnson
Apparatus And Method For Remote Assessment And Therapy Management In Medical Devices Via Interface Systems, Jeffrey Hargrove, Robert M. Ford, Thomas B. Johnson
Mechanical Engineering Patents
A remote medical assessment and therapy management apparatus comprising a center user interface, a center computer coupleable with the center user interface. The center computer displays information via the center user interface for use in developing a therapeutic prescription and receives therapeutic control inputs from a user. A remote device includes a medical diagnostic instrument for acquiring biophysical data from a patient, a medical therapeutic instrument that provides a therapy to the patient, and a remote computer that receives diagnostic signals from the diagnostic instrument and transmits therapeutic control signals to the therapeutic instrument. A network interface is connected between …
Cutaneous Electrode Positioning, Jeffrey Hargrove, Susan R. Briggs
Cutaneous Electrode Positioning, Jeffrey Hargrove, Susan R. Briggs
Mechanical Engineering Patents
A device and method for positioning a cutaneous electrode for delivery of electrical stimulation to a subject's head. A harness is worn on a subject's head with a first band of the harness worn in a closed loop around the subject's head and around a desired contact location on the subject's head. A tensioning strap of the harness is worn across the desired contact location and connected at spaced-apart attachment locations of the strap to spaced-apart attachment locations of the harness such that an electrode disposed over the desired contact location on the subject's head is held in place by …
Comparison Of Electronic And Mechanical Handgrip Devices In Lowering Blood Pressure, Katie Webb, Brandon Musarra, Megan O’Keefe, Shana Strunk, Courtney Perkins, Kenneth E. Sparks, Emily Kullman, Eddie T.C. Lam
Comparison Of Electronic And Mechanical Handgrip Devices In Lowering Blood Pressure, Katie Webb, Brandon Musarra, Megan O’Keefe, Shana Strunk, Courtney Perkins, Kenneth E. Sparks, Emily Kullman, Eddie T.C. Lam
Undergraduate Research Posters 2014
Hypertension causes billions of deaths per year (Millar et al., 2013). The Zona PlusTM is an expensive tool designed to lower blood pressure (BP) using isometric exercise. This exercise may be achieved using a less expensive Handgrip Dynamometer. PURPOSE: The purpose of this research is to determine if the Zona or Handgrip Dynamometer is more efficient at lowering BP and most cost effective for patients. METHODS: Twenty subjects used the Zona and twenty subjects used the dynamometer three times per week for six weeks. BP was taken once per week prior to the treatment. A maximum voluntary contraction (MVC) was …
Development, Characterization, And Optimization Of Process For Minimal Functional Barrier And Channel Width In Nitrocellulose Paper Microfluidic Diagnostic Platforms, Ryan Daniel Silva
Development, Characterization, And Optimization Of Process For Minimal Functional Barrier And Channel Width In Nitrocellulose Paper Microfluidic Diagnostic Platforms, Ryan Daniel Silva
Biomedical Engineering
A central goal of diagnostic microfluidics is to reduce the cost of diagnostic medicine by reducing the equipment and reagents needed to perform diagnostic tests. The literature has demonstrated that a wax printer can be used to pattern nitrocellulose paper with hydrophobic barriers to direct a sample in a defined reaction path, eliminating the need for external pumps and controllers. However, manufacturing methods for minimizing sample volume (and thus reagent volume) in a paper-diagnostic chip have not been well defined. In this work, we experimentally determine manufacturing processes for creating functional features of minimal size—effectively reducing the sample size and …
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …
An Experimental Study Of The Implementation Of A Fluid Diode Inside A Sano Shunt, Patrick Austin Lane
An Experimental Study Of The Implementation Of A Fluid Diode Inside A Sano Shunt, Patrick Austin Lane
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Fluid diodes are fluidic devices that enhance fluid flow in a particular direction while inhibiting it in the opposite direction without the use of moving parts. This is accomplished through the use of nozzle shaped geometry on one side of the diode, and cusp shaped geometry on the opposing side. Fluid meets very little resistance as is travels though the nozzle side of the diode. The cusps on the other side of the diode reduce the effective flow area, thereby inhibiting flow. The objective of this study is to determine the effectiveness of a fluid diode installed in a reconstructed …
Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka
Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Paradigm shifts in invasiveness, recovery time, cosmesis, and cost have been seen within the field of general surgery through major advances in surgical technology. Some of the most advanced types of general surgery now include Minimally Invasive Surgery (MIS), LaparoEndoscopic Single-Site (LESS) surgery, and Natural Orifice Translumenal Endoscopic Surgery (NOTES). One of the newest and rapidly developing catalysts is robotic platforms. Such platforms have improved ergonomics and control, increased workspace and dexterity, and have surpassed the efficacy of many non-robotic platforms such as traditional laparoscopic surgical tools. This thesis presents the design and development of a four-degree-of-freedom (4- DOF) miniature …
Improvements To Uhmwpe, Brooke Mckelvogue
Improvements To Uhmwpe, Brooke Mckelvogue
Journal of Undergraduate Research at Minnesota State University, Mankato
Ultra high molecular weight polyethylene (UHMWPE) is a material used in artificial implants for articular joint replacements. However, these implants have a limited lifespan in which the patient will be pain-free due to the wear of the UHMWPE components. Recently crosslinking, or exposing the material to radiation, has been used to extend the wear resistance of UHMWPE. Crosslinking introduces another set of drawbacks; mainly the reduction of the fracture toughness of UHMWPE and the generation of free radicals, which leave the polymer vulnerable to damage from oxidation. Currently, research is being conducted on other methods to increase the wear resistance …
Computational Model Of A Left Ventricle: Showing The Effects Of Inertia On Cardiac Dyssynchrony, Andrew Mcnally, Matthew Korpela, Erin Lamke, Matthew Hudson
Computational Model Of A Left Ventricle: Showing The Effects Of Inertia On Cardiac Dyssynchrony, Andrew Mcnally, Matthew Korpela, Erin Lamke, Matthew Hudson
Journal of Undergraduate Research at Minnesota State University, Mankato
In an effort to research heart failure, a leading cause of death in the industrialized world, this research team has developed a segmented lumped parameter model of the left ventricle. The computations model developed focuses on dyssynchrony, a heart condition where some regions of the heart vary significantly in properties like internal muscle resistance, mass, or elastance. Inertial effects are often assumed as negligible by cardiovascular models. One primary function of this model is to investigate inertial effects as they relate to mechanical cardiac dyssynchrony. An added dimension of this analysis is to observe the thermodynamics of the cardiac cycle …
Medical Applications Of Mrc, Kyle Thackston, Henry Mei, Pedro Irazoqui
Medical Applications Of Mrc, Kyle Thackston, Henry Mei, Pedro Irazoqui
The Summer Undergraduate Research Fellowship (SURF) Symposium
Consistent powering is a limiting reagent for many medical implants and sensors. Powering in-vivo devices in animal studies requires either transcutaneous wiring (limiting mobility and increasing the chance of infection) or an implanted battery (limited lifetime and limits size of device). Wireless power transfer (WPT) would be able to overcome these challenges and permit the use of more advanced implantable devices in a research setting. Magnetic resonance coupling (MRC), an advanced form of inductive charging, allows good transfer efficiencies over significant air gaps, but works best a specific location and frequency, limiting mobility in animal studies. Using band-pass filter theory, …
Wirelessly Powered And Transmitting Current Sensing Device, Christopher Quinkert, Steven Lee, Pedro Irazoqui
Wirelessly Powered And Transmitting Current Sensing Device, Christopher Quinkert, Steven Lee, Pedro Irazoqui
The Summer Undergraduate Research Fellowship (SURF) Symposium
As the rate of incidence of diabetes increases in the modern world, more accurate and reliable methods of glucose detection must be developed for patients with diabetes. Currently, 25.8 million people have diabetes in the United States alone and account for $174 billion in healthcare costs annually [1]. Devices that can be used without the need for as much patient interaction, regular replacement, or great patient expenses would be a large step forward in the ability of doctors and patients to effectively manage diabetes. To measure glucose concentrations in vivo, a biosensor is used to transduce glucose to an electrical …
Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong
Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong
Master's Theses
For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …
Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller
UNLV Theses, Dissertations, Professional Papers, and Capstones
Hypothermia is a life-threatening condition. Currently, active warming methods are the most effective treatment for dysthermic patients. The aim of this study is to investigate the use of computational fluid dynamics (CFD) in evaluating the thermal performance of a parallel/counter-parallel flow heat exchanger used as part of a fluid warmer to treat Hypothermia. The 3D model of the heat exchanger is divided into three regions; Infusate (fluid to be heated), Hot Water (heating fluid), and a Solid Region (wall). At the end of the heat exchanger, an elbow section is used to create the counter-parallel flow arrangement specific to this …
Impedance Biosensors For The Rapid Detection Of Viral And Bacterial Pathogens Using Avian Influenza Virus Subtypes H5n1 And H7n2 And Escherichia Coli O157:H7 As Model Targets, Jacob David Lum
Graduate Theses and Dissertations
This research investigated impedance biosensors for the rapid detection of viral and bacterial pathogens using avian influenza virus (AIV) subtypes H5N1 and H7N2 and Escherichia coli O157:H7 as the model targets, which were chosen due to their impact on the agricultural and food industries. For the detection of AIV H7N2, a single stranded DNA aptamer was selected using systematic evolution of ligands by exponential enrichment (SELEX). The selected aptamer and a previously selected aptamer against AIV H5N1 were used in a microfluidics chip with an embedded interdigitated array microelectrode to fabricate an impedance biosensor for specific detection of AIV H7N2 …
Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat
Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.
Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …
Experimental Terahertz Imaging And Spectroscopy Of Ex-Vivo Breast Cancer Tissue, Tyler C. Bowman
Experimental Terahertz Imaging And Spectroscopy Of Ex-Vivo Breast Cancer Tissue, Tyler C. Bowman
Graduate Theses and Dissertations
This thesis presents experimental results of terahertz imaging and spectroscopy techniques to analyze excised breast cancer tissue. The pulsed terahertz system at the University of Arkansas was used to assess formalin-fixed, paraffin-embedded breast cancer tissue obtained from 22, 40, and 46 year old patients. The tissue for this research was sliced to relatively thin sections of 10 μm thick and mounted on glass slides. Terahertz reflection time and frequency domain images of the breast cancer tissue were then obtained and compared to histopathology slides from the same patient. Results showed good correlation between the reflection images and histopathology slides for …
Automated Selection Of The Optimal Cardiac Phase For Single-Beat Coronary Ct Angiography Reconstruction, Daniel Stassi
Automated Selection Of The Optimal Cardiac Phase For Single-Beat Coronary Ct Angiography Reconstruction, Daniel Stassi
Master's Theses (2009 -)
This thesis investigates an automated algorithm for selecting the optimal cardiac phase for CCTA reconstruction. Reconstructing a low-motion cardiac phase improves coronary artery visualization in coronary CT angiography (CCTA) exams. Currently, standard end-systole and/or mid-diastole default phases are prescribed or alternatively, quiescent phases are determined by the user. As manual selection may be time-consuming and standard locations may be suboptimal due to patient variability, an automated method is investigated. An automated algorithm was developed to select the optimal phase based on quantitative image quality (IQ) metrics. For each reconstructed slice at each reconstructed phase, an image quality metric was calculated …
Preliminary Test Of A Real-Time, Interactive Silent Speech Interface Based On Electromagnetic Articulograph, Jun Wang, Ashok Samal, Jordan R. Green
Preliminary Test Of A Real-Time, Interactive Silent Speech Interface Based On Electromagnetic Articulograph, Jun Wang, Ashok Samal, Jordan R. Green
School of Computing: Conference and Workshop Papers
A silent speech interface (SSI) maps articulatory movement data to speech output. Although still in experimental stages, silent speech interfaces hold significant potential for facilitating oral communication in persons after laryngectomy or with other severe voice impairments. Despite the recent efforts on silent speech recognition algorithm development using offline data analysis, online test of SSIs have rarely been conducted. In this paper, we present a preliminary, online test of a real-time, interactive SSI based on electromagnetic motion tracking. The SSI played back synthesized speech sounds in response to the user’s tongue and lip movements. Three English talkers participated in this …