Open Access. Powered by Scholars. Published by Universities.®

Discipline
Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 481 - 510 of 1146

Full-Text Articles in Biomedical Devices and Instrumentation

Relative Contribution Of Arms And Legs Through Repetitive Assisted Sit-To-Stand Motion In Individuals With Incomplete Spinal Cord Injury, Abd Aziz Musfirah May 2020

Relative Contribution Of Arms And Legs Through Repetitive Assisted Sit-To-Stand Motion In Individuals With Incomplete Spinal Cord Injury, Abd Aziz Musfirah

Student Works (2020-2029)

Sit-To-Stand (SitTS) exercise is one of important prerequisites to achieve some functional independence goals in everyday life especially for individuals undergoing rehabilitation In general, the execution of SitTS in spinal cord injury (SCI) patients involves motor function in both upper and lower extremities. The use of arm support in particular is a very significant element while executing SitTS movement for SCI population. In addition, application of functional electrical stimulation (FES) onto the quadriceps muscles is one of the prescribed management for incomplete SCI to improve muscle action for simple lower limb movements. However, the relative contribution of upper and lower …


3-D Silk Fibroin Porous Particles Created By The Ouzo Effect For Biomedical Applications, Ashley Nicole Lamb May 2020

3-D Silk Fibroin Porous Particles Created By The Ouzo Effect For Biomedical Applications, Ashley Nicole Lamb

UNLV Theses, Dissertations, Professional Papers, and Capstones

Due to its high biocompatibility and biodegradability, silk fibroin – produced from

Bombyx mori (B. mori) cocoons – has been at the forefront of research for many

biomedical application formats: hydrogels, films, microspheres, and porous

sponges/scaffolding, to name a few. For drug delivery, in particular, porous particles are

desirable for their large surface area, uniform and tunable pore structure, and high

porosity. This thesis focuses on the fabrication of porous particles from silk fibroin by the

very interesting Ouzo effect. The Ouzo effect, so named because of the Greek

beverage ouzo, describes the phenomenon of an ethanol + anethole oil …


3d Parametric Hand To Improve Prosthetic Hand Functionality, Maria C. Gerardi May 2020

3d Parametric Hand To Improve Prosthetic Hand Functionality, Maria C. Gerardi

UNLV Theses, Dissertations, Professional Papers, and Capstones

The use of prosthetics can significantly enhance an individual’s standard of living, not only offering functional advantages but psychological advantages as well. Unfortunately for children with upper limb reduction, options are limited and rejection rates are high due to a multitude of reasons including discomfort and poor functionality. This study proposes a new parametric 3D design model (Parametric Hand) with an adjustable thumb that can be easily manipulated to the uniqueness of an individual. The Parametric Hand was evaluated, both qualitatively and quantitatively, against the Flexy-Hand 2, a commonly used prosthetic hand. The results showed insignificant differences in all testing …


A High Frequency Photoacoustic System For Colorectal Cancer Imaging, Kexin Huang May 2020

A High Frequency Photoacoustic System For Colorectal Cancer Imaging, Kexin Huang

McKelvey School of Engineering Graduate Student Theses & Dissertations

While colorectal cancer is the second largest cause of cancer-related deaths in the United States, early detection is a key factor in its survival rate. Compared to conventional imaging modalities, photoacoustic imaging offers benefits in providing angiographic images which are valuable for early-stage tumor detection. This thesis presents the design of a 32-channel 80 MHz photoacoustic image system, whose relatively high frequency offers particular advantages. The system comprises several modules, including a laser system, ultrasound probe, AD convertor, microcontroller (FPGA), and a computer. The system requires programs for the FPGA and the data receiver on the computer. The data transportation …


Artifact Identification For Blood Pressure And Photoplethysmography Signals In An Unsupervised Environment, Pooi Khoon Lim May 2020

Artifact Identification For Blood Pressure And Photoplethysmography Signals In An Unsupervised Environment, Pooi Khoon Lim

Student Works (2020-2029)

Physiological signals play a significant role in clinical diagnosis, it always acts as a major input of a decision support system. However, the physiological signal is easily corrupted by different factors especially motion artifacts. Several research works have been tried to recover the underlying physiological signal by suppressing the artifact. However, not much attention has been paid to situation where the artifact is too extreme and the artifact suppression is not possible. In this situation, physiological signal quality must be evaluated before any further assessment. In this study, an automated artifact detection algorithm was developed for Blood Pressure and PPG …


Mechanical Analysis Of In Vitro Tbi Models, Dana Hamed Apr 2020

Mechanical Analysis Of In Vitro Tbi Models, Dana Hamed

Honors Scholar Theses

This work details the damage done to cells when mechanically hit. The goal was to mechanically analyze in vitro traumatic brain injury (TBI) models. Parts were designed in SolidWorks to create the machine that is used to induce this damage on the cells. A force applicator that uses a 3D-printed micro-hammer to apply force on the brain cells that are being tested was created. Mechanical trauma experimentation was performed with the force applicator, while a high-speed camera recorded the damage, in order to analyze TBI models. Displacement along the scaffold can be tracked from multiple video frames. With these results, …


Designing An Antibiotic Eluting Trauma Screw To Reduce Short Term Infection In Bone Fractures, Dominic Lincoln Apr 2020

Designing An Antibiotic Eluting Trauma Screw To Reduce Short Term Infection In Bone Fractures, Dominic Lincoln

Honors Theses

Orthopedic infection in the United States is one of the most common and severe health risks faced by trauma patients. The most prevalent infection is orthopedic and trauma device-related infection (ORDI) and often occurs in long bones at the fracture site. The purpose of this paper is to explore this infection, its causes, and solutions currently on the market while providing novel solutions to the problem. The designs proposed will be evaluated for their effectiveness and value, while attempting to keep costs low for all stakeholders. The feasibility of patenting these ideas will also be considered, as will the testing …


“Gobabygo!” Rehab Engineering To Make Children Mobile, Connor Albin, Chase M. Pfeifer Apr 2020

“Gobabygo!” Rehab Engineering To Make Children Mobile, Connor Albin, Chase M. Pfeifer

UCARE: Research Products

GoBabyGo! is a project to give children with movement difficulties a chance to move on their own. GoBabyGo! conducts community builds of modified ride-on-cars for these children and grants them mobility. Once issue is that once children have cars, there is no feedback to improve future builds. This project "“GoBabyGo!” – Rehab Engineering to Make Children Mobile," wishes to collect quantifiable data on how these cars are being used and how they can be improved. This project aims to do this by collecting surveys from caretakers and through a programmed module to be installed in cars. The installed car module …


How Do Surgeon Preferences And Technique Variances Affect Outcome?, Anastasia Axiopoulou, Caroline G. L. Cao, Katherine Lin Md, Keith Watson Md Apr 2020

How Do Surgeon Preferences And Technique Variances Affect Outcome?, Anastasia Axiopoulou, Caroline G. L. Cao, Katherine Lin Md, Keith Watson Md

Celebration of Undergraduate & Graduate Research, Scholarship, and Creative Activities Materials

The goal of the research project is to create a blue-print of a robot-assisted hysterectomy procedure to support design and evaluation of technology to enhance system performance. To create this blue-print, we will conduct a task analysis, model the cognitive task flow and decision making, and develop a simulation of the hysterectomy procedure. The surgical simulation will be used as a platform to train surgeons on robotic-assisted hysterectomies, as well as to assess learning and performance. Additionally, it will be used to design and develop techniques and novel technology to support surgeons in their performance of the surgery. Current research …


Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney Mar 2020

Diy Incubator, Aryan Zia, Grace Spurlock, Garrett Janney

Biomedical Engineering

This project report provides detailed information on designing and building a DIY Incubator. The device is indicated for growing and maintaining BSL-1 mammalian or bacterial cell culture with a temperature control in the range of 25-45°C ± 1°C. The device is made fully programmable via an Arduino, and is structurally designed to fit two T75 cell culture flasks at a time. The device is able to return to a specified temperature set point within 10 minutes and maintains 5% CO2 partial pressure conditions. The incubator has a small physical footprint, with an overall dimension of 22in x 16in x 15.5in …


Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso Mar 2020

Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso

Biomedical Engineering

The purpose of this scope of work is to highlight the progress and development of SoloStand sponsored by Derek Herrera, chief technical officer and founder of SpinalSingularity. SoloStand is an attachment to a wheelchair that will benefit paraplegics that use wheelchairs. A portable and customizable attachment to a wheelchair will allow the user to do everyday tasks without transferring into a separate standing wheelchair and travel more easily. This document outlines everything that has been done in fulfillment of our senior project requirements.


Total Knee Arthroplasty Gap Balancer, Christina Grigorian, Andrew Beckley, Alexandra Rockett Mar 2020

Total Knee Arthroplasty Gap Balancer, Christina Grigorian, Andrew Beckley, Alexandra Rockett

Biomedical Engineering

California Polytechnic State University’s Biomedical Engineering Department worked in conjunction with local San Luis Obispo orthopedic surgeon Dr. Dimitri Delagrammaticas. The goal of the project was to create a surgical tool that assists a surgeon in measuring knee gap distance and balancing collateral ligament tension during a total knee arthroplasty (TKA) surgery. The final product of this project was completed in five months and initially began with understanding our sponsor’s expectations for the device. A portion of time was devoted to conducting research to understand the process of a knee replacement surgery, the requirements of the device, and the limitations …


On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss Mar 2020

On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss

Biomedical Engineering

No abstract provided.


Integrity Testing Of Gas Permeable Silicone Filters, Maggie M. Baker, Thomas P. Humann, Kevin J. Yerina Mar 2020

Integrity Testing Of Gas Permeable Silicone Filters, Maggie M. Baker, Thomas P. Humann, Kevin J. Yerina

Biomedical Engineering

This report investigates the most reasonable, cost efficient, and reliable ways to integrity test a filter made from a permeable silicone membrane for future biomedical and pharmaceutical applications. The goal of the project was to create a fixture that a pharmaceutical company can use to quickly and reliably test the integrity of the filter. A variety of methods are outlined to test the integrity of the filter, after a series of quantitative tests, a single method was established that meet the requirements most thoroughly. The method that was determined to be most effective involves a series of components including a …


Investigation Of Dielectric Properties Of Urine For Pregnancy And Bladder Cancer Detection, Chao Zhe Zhu Mar 2020

Investigation Of Dielectric Properties Of Urine For Pregnancy And Bladder Cancer Detection, Chao Zhe Zhu

Student Works (2020-2029)

Detection and monitoring of pregnancy and bladder cancer are important for medical treatment and nursing. Urine has diagnostic and prognostic values for pregnancy and bladder cancer due to the presence of biomarkers. This study investigated the dielectric properties of human urine and compared them between two groups: 1) non-pregnant healthy female volunteers and pregnant healthy female volunteers, and; 2) healthy subjects and patients with bladder cancer. An open-ended probe network analyzer was used to measure the urine dielectric constant (Ɛ’) and dielectric loss (Ɛ’’) at microwave frequency ranging from 0.2GHz to 50GHz at 25˚C (room temperature), 30˚C and 37˚C (body …


Prosthetic Thumb, Allison M. Sigdestad, Sahil Sharma, Cale Foreman Mar 2020

Prosthetic Thumb, Allison M. Sigdestad, Sahil Sharma, Cale Foreman

Biomedical Engineering

The Prosthetic Thumb Project is a senior design project completed by Biomedical Engineering Undergraduate students at California Polytechnic State University. This senior design project is aimed at designing a prosthetic thumb for a Cal Poly Pomona student who lost their thumb in an accident last year. The patient has ultimately lost between 30-40% of functionality of his left hand, and so we would like to give him that mobility back. Originally, the patient was worried about having a prosthesis, and wanted something more stagnant that would resemble the look of the thumb he lost. However, after working with him, we …


Esophageal Temperature Mapping And Monitoring Sheath, Nicole M. Rogers, Hillary Johnson, Alexander Silva Mar 2020

Esophageal Temperature Mapping And Monitoring Sheath, Nicole M. Rogers, Hillary Johnson, Alexander Silva

Biomedical Engineering

The purpose of this document is to provide a product development summary for an accessory device that joins an esophageal temperature probe and a mapping catheter together to be used during cardiac ablation. Catheter ablation therapy is performed in the left atrium, utilizing extremely hot or cold temperatures to create scar tissue and treat atrial fibrillation and other arrhythmias. The close positioning of the left atria adjacent to the esophagus presents a large risk as the extreme temperatures used during ablation can lead to esophageal damage or fistulas. This device is designed to integrate correlate data from the temperature probe …


Housecalls Mobile: Virtual Stethoscope/Otoscope, Julia Kelley, Cullen Mcgee, Eduardo Uribe-Saldana Mar 2020

Housecalls Mobile: Virtual Stethoscope/Otoscope, Julia Kelley, Cullen Mcgee, Eduardo Uribe-Saldana

Biomedical Engineering

At the start of the project, our initial deliverables were to add a low cost camera into virtual otoscope and to add a pediatric attachment to the stethoscope. However, about half way through the first quarter (1.5 months into the project), our deliverables changed to the following: to design a housing unit for the selected otoscope camera and to increase battery life to allow for 12+ battery life. To accomplish our deliverables, we divided up the responsibilities as follows: One person headed the mechanical design, one person headed the electrical design, and one person served as a liaison between the …


Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen Mar 2020

Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen

Biomedical Engineering

This document comprises the steps taken by the senior project team to create a Proof-of-Concept Review for a Variable Pulsed Electric Field Ablation Catheter. First, the team did a significant amount of background research on related literature to better understand the current status of the project topic. After sufficient background information was obtained, project objectives and deliverables were finalized. Once customer requirements and the indications for use were completed, engineering specifications for the product and project were documented. All key customer requirements and engineering specs were related to the variable pulse functionality, maneuverability, as well as overall dimensioning of the …


Insulative (Direct Current) Dielectrophoretic Foul-Less Filtration In Microfuidic Systems, Matthew A A Whitman Mar 2020

Insulative (Direct Current) Dielectrophoretic Foul-Less Filtration In Microfuidic Systems, Matthew A A Whitman

Master's Theses

Filtration is a technology that is used almost ubiquitously in society from uses raging from filtration of macroparticles from water to pharmaceutical grade filtration products to remove anything larger than a protein. However, with such a wide range of uses, most filtration products have the same issue; membrane clogging (fouling) that prevents continuous use and requires frequent maintenance. This thesis hypothesizes that by applying a direct current (DC) to an insulating array of posts, they will create a foul-less insulative dielectrophoretic filter (iDEP) that does not clog since particles will levitate above the insulating array.

This thesis tested an inherited …


Artificial Kidney And Hemodialysis, Zhongping Huang Feb 2020

Artificial Kidney And Hemodialysis, Zhongping Huang

Physics & Engineering Faculty Publications

No abstract provided.


Effect Of Tio2 Doping On Degradation Rate, Microstructure And Strength Of Borate Bioactive Glass Scaffolds, Romina Shafaghi, Omar Rodriguez, Sunjeev Phull, Emil H. Schemitsch, Paul Zalzal, Stephen D. Waldman, Marcello Papini, Mark R. Towler Feb 2020

Effect Of Tio2 Doping On Degradation Rate, Microstructure And Strength Of Borate Bioactive Glass Scaffolds, Romina Shafaghi, Omar Rodriguez, Sunjeev Phull, Emil H. Schemitsch, Paul Zalzal, Stephen D. Waldman, Marcello Papini, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

A titanium-containing borate glass series based on the system (52-X) B2O3–12CaO–6P2O5–14Na2O–16ZnO-XTiO2 with X varying from 0, 5 and 15 mol% of TiO2 incorporated, identified as BRT0, BRT1 and BRT3, respectively, were used in this study. Scaffolds (pore sizes, 165–230 μm and porosity, 53.51–69.51%) were prepared using a polymer foam replication technique. BRT3 scaffolds exhibited higher compressive strength (7.16 ± 0.22 MPa) when compared to BRT0 (6.02 ± 0.47 MPa) and BRT1 (5.65 ± 0.28 MPa) scaffolds with lower, or no, TiO2 content. The solubility of the scaffolds decreased …


Experimental And Computational Tools For Single Cell Analysis In Cancer Diagnostics, Manibarathi Vaithiyanathan Jan 2020

Experimental And Computational Tools For Single Cell Analysis In Cancer Diagnostics, Manibarathi Vaithiyanathan

LSU Doctoral Dissertations

Substantial evidence shows that cellular heterogeneity commonly exists within an isogenic or clonal population. Whether in isolation or caused through a combination of the above events, cellular heterogeneity can dramatically influence cellular decision making and cell fate, however, this can be masked by the average response from a population. One approach to solve this issue is to analyze a population at the individual cell level. The goal of this work is to develop high-throughput experimental and computational platforms to screen and quantify single cancer cells for specific intracellular enzyme activities. An interdisciplinary approach was taken to 1) better understand the …


Development Of A Single Use Device Intended To Wash Blood Clot Debris From A Stent Retriever In The Operating Room, Shane Diller Jan 2020

Development Of A Single Use Device Intended To Wash Blood Clot Debris From A Stent Retriever In The Operating Room, Shane Diller

Theses and Dissertations

Ischemic stroke is a life-threatening condition that requires immediate surgical intervention to remove the blood clot that is lodged in the blood vessels of the brain. Mechanical thrombectomy, performed by an endovascular surgeon, involves inserting a stent retriever, which deploys distally and attempts to capture the clot when dragged backwards. A complication prevalent in 50% - 67% of cases is that the blood clot is only partially removed and clings to the mesh framework of the stent. The operating surgeon must either clean the debris from the stent retriever, to be reinserted or throw the stent retriever away and open …


Knee Joint Loading Following Anterior Cruciate Ligament Reconstruction: Link To Patient Reported Outcomes And A Novel Method To Monitor With Wearable Sensors, Alex Spencer Jan 2020

Knee Joint Loading Following Anterior Cruciate Ligament Reconstruction: Link To Patient Reported Outcomes And A Novel Method To Monitor With Wearable Sensors, Alex Spencer

Theses and Dissertations--Kinesiology and Health Promotion

Recovery from anterior cruciate ligament reconstruction (ACLR) commonly results in undesirable physical and patient-reported outcomes (PROs). Identification of modifiable factors such as knee contact force (KCF) early in rehabilitation that can improve these outcomes is important due to the rapid decrease in function, quality of life, and joint health in this population. Additionally, if noninvasive measurement of KCFs outside of a traditional laboratory were possible, clinicians could optimize patient treatment with personalized care. Therefore, there are two primary aims to this thesis: 1) quantify the link between KCF and PROs which measure pain, ability to perform activities of daily living, …


Assessment Of White Matter Hyperintensity, Cerebral Blood Flow, And Cerebral Oxygenation In Older Subjects Stratified By Cerebrovascular Risk, Ahmed A. Bahrani Jan 2020

Assessment Of White Matter Hyperintensity, Cerebral Blood Flow, And Cerebral Oxygenation In Older Subjects Stratified By Cerebrovascular Risk, Ahmed A. Bahrani

Theses and Dissertations--Biomedical Engineering

Objective: Cerebrovascular disease (CVD) is the fifth most common cause of mortality in the United States. Diagnosis of CVD at an early stage is critical for optimal intervention designed to prevent ongoing and future brain injury. CVD is commonly associated with abnormalities of the cerebral microvasculature leading to tissue dysfunction, neuronal injury and death, and resultant clinical symptoms, which in turn, further impacts cerebral autoregulation (CA). This series of studies aims to test the hypothesis that white matter hyperintensities (WMH) and cerebral hemodynamics (quantified by magnetic resonance imaging (MRI) and an by innovative hybrid near-infrared diffuse optical instrument) can be …


Noncontact Multiscale Diffuse Optical Imaging Of Deep Tissue Hemodynamics In Animals And Humans, Siavash Mazdeyasna Jan 2020

Noncontact Multiscale Diffuse Optical Imaging Of Deep Tissue Hemodynamics In Animals And Humans, Siavash Mazdeyasna

Theses and Dissertations--Biomedical Engineering

Blood flow (BF) impacts the delivery of oxygen and nutrients to tissues and the removal of metabolic byproducts from tissues. Imaging of BF distributions helps characterize many diseases associated with tissue hypoxia/ischemia. The purpose of this study was to develop and validate a novel, noninvasive, noncontact, high-density camera-based speckle contrast diffuse correlation tomography (scDCT) device for use in both animal and human studies. The scDCT uses a galvo-mirror to remotely deliver the focused point near-infrared light to source positions and a sensitive 2D camera to quantify spatial diffuse speckle fluctuations, resulting from the movement of red blood cells in deep …


3d Printing Of Iron Oxide Incorporated Polydimethylsiloxane Soft Magnetic Actuator, Rasoul Bayaniahangar Jan 2020

3d Printing Of Iron Oxide Incorporated Polydimethylsiloxane Soft Magnetic Actuator, Rasoul Bayaniahangar

Dissertations, Master's Theses and Master's Reports

Soft actuators have grown to be a topic of great scientific interest recently. As the fabrication of soft actuators with conventional microfabrication methods are tedious, expensive, and time consuming, employment of 3-D printing fabrication methods appears promising as they can simplify fabrication and reduce the production cost. Complex structures can be fabricated with 3-D printing such as helical coils can achieve actuation performances that otherwise would not be possible with simpler geometries. In this thesis development of soft magnetic helical coil actuators of iron-oxide embedded polydimethylsiloxane (PDMS) was achieved with embedded 3-D printing techniques. Composites with three different weight ratios …


The Tera Multi Terrain Mobility Aid Chassis, Colton Kemp, Daniel Nicoll, Ibrahim Suleiman, Mohammad Alyami Jan 2020

The Tera Multi Terrain Mobility Aid Chassis, Colton Kemp, Daniel Nicoll, Ibrahim Suleiman, Mohammad Alyami

Williams Honors College, Honors Research Projects

The natural environment poses a significant number of obstacles and dynamic settings that makes mobility difficult for those with physical and mobility impairments. To approach this problem, a suspension was designed using inspiration from the early Mars rovers developed by NASA for traversing the varied Martian landscape. The course of the project followed the direction of a start-up through problem identification, early design generation and review, and final design production. The project outcome, through client request and proven market research, aimed to produce a multi-terrain wheelchair. The final product is a kinematic body with mobile front “legs” and a rotational …


Prosthetic Hand, Nicholas Damiani, Eric Rassavong, John Zolton Jan 2020

Prosthetic Hand, Nicholas Damiani, Eric Rassavong, John Zolton

Williams Honors College, Honors Research Projects

Development of a prosthetic hand for an above-the-wrist amputee. The hand will provide flexion and extension of the wrist, fingers and thumb. The device will be customized for each individual by utilizing an medical imaging of the amputation side stump and the normal arm/wrist as the input. An integral hand/wrist and socket will be 3D printed, and actuators will be mounted to the prosthetic to provide motion. The wrist will be a mirror-image of the normal hand. Materials utilized will be selected based on the medical image intensity for different tissue types (cartilage, bone, skin, fat, etc.) and will simulate …