Open Access. Powered by Scholars. Published by Universities.®

2013

Discipline
Institution
Keyword
Publication
Publication Type

Articles 1 - 30 of 52

Full-Text Articles in Biomedical Devices and Instrumentation

St. Jude Medical: Pulmonary Edema Monitoring In Pacemakers And Icds, David Wei-Péng Chang Dec 2013

St. Jude Medical: Pulmonary Edema Monitoring In Pacemakers And Icds, David Wei-Péng Chang

Master's Theses

Pulmonary edema occurs when fluid leaks from the pulmonary capillary network into the lung interstitium and alveoli. When the heart is not able to pump blood to the body efficiently, fluid can back up into the veins that take blood through the lungs to the left atrium. This then builds up the pressure in the blood vessels and fluid is pushed into the alveoli in the lungs. The fluid reduces normal oxygen movement through the lungs and can cause impaired gas exchange and respiratory failure. There are many causes of congestive heart failure that may lead to pulmonary edema such …


Formulation Development Of A Polymer-Drug Matrix With A Controlled Release Profile For The Treatment Of Glaucoma, Eric W. Tsoi Dec 2013

Formulation Development Of A Polymer-Drug Matrix With A Controlled Release Profile For The Treatment Of Glaucoma, Eric W. Tsoi

Master's Theses

Glaucoma is the leading cause of blindness in the United States accounting for 9-12% of all cases of blindness. Currently, the front line treatment for glaucoma are prostaglandins that may have to be taken up to several times a day. Even with proper treatment, roughly 11% of the patients using the treatment are non-compliant and lose their vision. In this project, ForSight Laboratories has developed a pharmaceutical drug delivering implant with the capability of sustaining long-term release of a prostaglandin as a new way to treat the condition. This project reports the product development of a polymer drug matrix with …


Characteristics Of Glass Ionomer Cements Composed Of Glass Powders In Cao-Sro-Zno-Sio2 System Prepared By Two Different Synthetic Routes, Ill Yong Kim, Chikara Ohtsuki, Aisling Coughlan, Lana Placek, Anthony W. Wren, Mark R. Towler Dec 2013

Characteristics Of Glass Ionomer Cements Composed Of Glass Powders In Cao-Sro-Zno-Sio2 System Prepared By Two Different Synthetic Routes, Ill Yong Kim, Chikara Ohtsuki, Aisling Coughlan, Lana Placek, Anthony W. Wren, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Glass ionomer cements (GICs) are composed of an acid degradable glass, polyacrylic acid and water. Sol-gel processing to prepare the glass phase has certain advantages, such as the ability to employ lower synthesis temperatures than melt quenching and glasses that are reported to have higher purity. A previous study reported the effects of glass synthesis route on GIC fabrication. However, in that study, the sol-gel derived glass exhibited a reduced concentration of cations. This study investigates increasing the cation content of a sol-gel derived glass, 12CaO·4SrO·36ZnO·48SiO2 (molar ratio) by heating before aging to reduce dissolution of cations. This glass …


Characterization And Feasibility Of A Portable Oxygen Concentrator For Use With A Mass Casualty Ventilator, Paul Robert Williams Dec 2013

Characterization And Feasibility Of A Portable Oxygen Concentrator For Use With A Mass Casualty Ventilator, Paul Robert Williams

Boise State University Theses and Dissertations

The American Association for Respiratory Care has reported a need to stockpile 5,000-10,000 mass casualty ventilators with supplemental oxygen in preparation for pandemic emergencies (1). The American Medical Association specifies oxygen concentrators supply oxygen at 5 liters per minute at ≥90% purity (2). However, these design specifications may not be the most efficient use of system resources in portable oxygen concentrators using pressure swing adsorption. A testbed was developed to investigate the system performance of an oxygen concentrator while altering the system inlet and outlet pressures and flow rates. This investigation demonstrates that a more efficient portable oxygen concentrator, which …


Near-Infrared Surface-Enhanced Fluorescence Using Silver Nanoparticles In Solution, Michael D. Furtaw Dec 2013

Near-Infrared Surface-Enhanced Fluorescence Using Silver Nanoparticles In Solution, Michael D. Furtaw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Fluorescence spectroscopy is a widely used detection technology in many research and clinical assays. Further improvement to assay sensitivity may enable earlier diagnosis of disease, novel biomarker discovery, and ultimately, improved outcomes of clinical care along with reduction in costs. Near-infrared, surface-enhanced fluorescence (NIR-SEF) is a promising approach to improve assay sensitivity via simultaneous increase in signal with a reduction in background. This dissertation describes research conducted with the overall goal to determine the extent to which fluorescence in solution may be enhanced by altering specific variables involved in the formation of plasmonactive nanostructures of dye-labeled protein and silver nanoparticles …


Brain-Related Chronic Pain Disorder Treatment Method And Apparatus, Jeffrey Hargrove, Robert M. Ford, Buckley D. Beranek Nov 2013

Brain-Related Chronic Pain Disorder Treatment Method And Apparatus, Jeffrey Hargrove, Robert M. Ford, Buckley D. Beranek

Mechanical Engineering Patents

A method for treating brain-related chronic pain disorders in human subjects includes assessing the brain function of a subject suffering from chronic pain, diagnosing a chronic pain-related abnormal brain condition, and mitigating the abnormal brain activity by applying an electrical stimulation signal to tissues corresponding to at least one area of abnormal brain activity.


Biocompatibility Of Cao-Na2o-Sio2/Tio2 Glass Ceramic Scaffolds For Orthopaedic Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler Nov 2013

Biocompatibility Of Cao-Na2o-Sio2/Tio2 Glass Ceramic Scaffolds For Orthopaedic Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

This work aims to determine the effect of substituting TiO2 for SiO2 in a 0.62SiO2-Na2O-0.24CaO based glass-ceramic scaffold. High temperature X-ray Diffraction (HT-XRD) was used to determine the sintering temperature (700oC). Both optical microscopy and x-ray micotomography was used to determine the average pore size (540-680ìm) of each scaffold. Cytocompatibility of each scaffold was conducted using murine mesenchymal stem cells. © 2013 IEEE.


Gallium Containing Glass Polyalkenoate Bone Cements: Ion Release And E. Coli Inhibition, L. Placek, A. W. Wren, A. Coughlan, Mark R. Towler Nov 2013

Gallium Containing Glass Polyalkenoate Bone Cements: Ion Release And E. Coli Inhibition, L. Placek, A. W. Wren, A. Coughlan, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

The Glass Polyalkenoate Cement (GPC) series (LCon., LGa-1 and LGa-2) containing gallium (Ga) and a 50 wt% addition of E11 polyacrylic acid (PAA), previously developed, was evaluated for ion release, specifically Si, Ca, Zn and Ga, and E. coli inhibition. The maximum inhibition was observed in the t = 0 samples and was 0.35 mm for LCon. and 0.65 mm for LGa-1 and LGa-2. © 2013 IEEE.


An Investigation Into The Structure And Properties Of Cao-Zno-Sio 2-Tio2-Na2o Bioactive Glass/Hydroxyapatite Composite, Chokchai Yatongchai, Mark R. Towler, Anthony W. Wren Nov 2013

An Investigation Into The Structure And Properties Of Cao-Zno-Sio 2-Tio2-Na2o Bioactive Glass/Hydroxyapatite Composite, Chokchai Yatongchai, Mark R. Towler, Anthony W. Wren

Chemical and Biochemical Engineering Faculty Research & Creative Works

Effect of the addition of CaO-ZnO-SiO2-TiO2-Na2O glass as a reinforcing phase on properties of hydroxyapatite/glass composites was investigated. The addition of the glass caused the decomposition of HA phase to tricalcium phosphate, inhibiting densification in the HA/glass composites. However, depending on the glass concentration, some of the glass can act as a sintering aid enhancing the densification in the composites. © 2013 IEEE.


Relating Ph And Ion Release From Ga2o3-Na 2o-Cao-Zno-Sio2 Bioactive Glasses, T. J. Keenan, A. W. Wren, A. Coughlan, Mark R. Towler, M. M. Hall Nov 2013

Relating Ph And Ion Release From Ga2o3-Na 2o-Cao-Zno-Sio2 Bioactive Glasses, T. J. Keenan, A. W. Wren, A. Coughlan, Mark R. Towler, M. M. Hall

Chemical and Biochemical Engineering Faculty Research & Creative Works

Three glasses were designed for this study, including one Ga-free glass (Control), and two Ga-containing glasses (TGa-1, TGa-2). In the Ga-containing glasses, Ga2O3 is included at the expense of ZnO. This study focuses on the relation between pH and ion concentration present in solution in which these bioactive glasses have been submerged for periods of 1, 7, and 14 days. © 2013 IEEE.


Wireless Myoelectric Sensor Minimization And Packaging, Ásbjörg Einarsdóttir, Pedro Irazoqui Dr. Oct 2013

Wireless Myoelectric Sensor Minimization And Packaging, Ásbjörg Einarsdóttir, Pedro Irazoqui Dr.

The Summer Undergraduate Research Fellowship (SURF) Symposium

Many people suffer from amputation, which affects their lives severely by disabling them from doing chores in their daily life as well as chores related to work and leisure. For the last years, prosthetics’ development has been fast and the devices that are being used now are a miracle compared to what has been used before. But still, the battle is not over yet. Although scientists have techniques and devices to use nerve residues from the amputated limb to control the prosthetic, smaller devices that can detect the signals from those nerves better need to be developed. In this research …


A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie Oct 2013

A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie

The Summer Undergraduate Research Fellowship (SURF) Symposium

Chronic wounds affect 6.5 million patients a year while consuming US$25 billion in health care costs (Sen 2009 Wound Repair Regen.). Despite advances in wound management therapies, modern treatment for chronic wounds still requires continual professional attention and expensive equipment, posing serious practical and financial burdens for the regular patient. To provide an alternative solution, we are developing a low-cost smart bandage platform that integrates actuators and sensors to monitor and treat chronic wounds. One component of the integrated platform is an oxygen-generating module. It is a polydimethylsiloxane (PDMS) based microfluidic device fabricated on a parchment paper substrate that …


Dynamic Balance Control During Treadmill Walking In Chronic Stroke Survivors, Eric Richard Walker Oct 2013

Dynamic Balance Control During Treadmill Walking In Chronic Stroke Survivors, Eric Richard Walker

Dissertations (1934 -)

Maintaining dynamic balance is an important component of walking function that is likely impaired in chronic stroke survivors, evidenced by an increased prevalence of falls. Dynamic balance control requires maintaining the center of mass (COM) within the base of support during movement. During walking, dynamic balance control is achieved largely by modifying foot placement to adjust the base of support. However, chronic stroke survivors have difficulty with both precision control of foot placement, as well as reduced control of COM movement. The objective of this dissertation was to characterize dynamic balance control strategies during walking in chronic stroke survivors. Additionally, …


Supraspinal Control Of Unilateral Locomotor Performance: An Fmri Study Using A Custom Pedaling Device, Brett Arand Oct 2013

Supraspinal Control Of Unilateral Locomotor Performance: An Fmri Study Using A Custom Pedaling Device, Brett Arand

Master's Theses (2009 -)

This study aimed to develop a novel unilateral pedaling device, validate its function, and use it in an fMRI study of bilateral vs. unilateral locomotor control. The new device is MRI compatible and allows for conventional coupled bilateral pedaling, along with decoupled unilateral pedaling. It was designed with an assistance mechanism to simulate the presence of the non-contributing leg while pedaling unilaterally. During coupled bilateral pedaling, the two legs work in unison: while one leg is extending in the downstroke, it provides support to lift the other leg back up as it is flexing in the upstroke. The device uses …


Comparison Of A Sio2-Cao-Zno-Sro Glass Polyalkenoate Cement To Commercial Dental Materials: Ion Release, Biocompatibility And Antibacterial Properties, A. W. Wren, A. Coughlan, M. M. Hall, M. J. German, Mark R. Towler Sep 2013

Comparison Of A Sio2-Cao-Zno-Sro Glass Polyalkenoate Cement To Commercial Dental Materials: Ion Release, Biocompatibility And Antibacterial Properties, A. W. Wren, A. Coughlan, M. M. Hall, M. J. German, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Ion Release and biocompatibility of a CaO-SrO-ZnO-SiO2 (BT 101) based glass polyalkenoate cement (GPC) was compared against commercial GPCs, Fuji IX and Ketac Molar. The radiopacity (R) was similar for each material, 2.0-2.8. Ion release was evaluated on each material over 1, 7, 30 and 90 days. BT 101 release included Ca (23 mg/L), Sr (23 mg/L) Zn (13 mg/L), Si (203 mg/L). Fuji IX release includes Ca (0.7 mg/L), Al (3 mg/L) Si (26 mg/L), Na (60 mg/L) and P (0.5 mg/L) while Ketac Molar release includes Ca (1 mg/L), Al (0.6 mg/L) Si (23 mg/L), Na (76 …


Force Sensing Surgical Scissor Blades Using Fibre Bragg Grating Sensors, Dean Callaghan Sep 2013

Force Sensing Surgical Scissor Blades Using Fibre Bragg Grating Sensors, Dean Callaghan

Doctoral

This thesis considers the development and analysis of unique sensorised surgical scissor blades for application in minimally invasive robotic surgery (MIRS). The lack of haptic (force and tactile) feedback to the user is currently an unresolved issue with modern MIRS systems. This thesis presents details on smart sensing scissor blades which enable the measurement of instrument-tissue interaction forces for the purpose of force reflection and tissue property identification. A review of current literature established that there exists a need for small compact, biocompatible, sterilisable and robust sensors which meet the demands of current MIRS instruments. Therefore, the sensorised blades exploit …


Multimodal Wearable Sensors For Human-Machine Interfaces, Mark Nolan Aug 2013

Multimodal Wearable Sensors For Human-Machine Interfaces, Mark Nolan

Doctoral

Certain areas of the body, such as the hands, eyes and organs of speech production, provide high-bandwidth information channels from the conscious mind to the outside world. The objective of this research was to develop an innovative wearable sensor device that records signals from these areas more conveniently than has previously been possible, so that they can be harnessed for communication. A novel bioelectrical and biomechanical sensing device, the wearable endogenous biosignal sensor (WEBS), was developed and tested in various communication and clinical measurement applications.

One ground-breaking feature of the WEBS system is that it digitises biopotentials almost …


Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw Aug 2013

Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The concept of underactuation has been previously developed in the robotic field for grasping applications. For these anthropomorphic grippers, the minimization of the number of input signals, or in other words underactuation, is the most expected characteristic. This method has become very popular in recent decades. Indeed, by minimizing the number of input signals, it minimizes the complexity of the system’s control and at the same time avoids increased weight and cost. The inconvenience of such a technique is that the design of this type of system remains a difficult task if the behavior of the underactuated set of joints …


Method And Apparatus For Electrical Stimulation Of Tissues Using Signals That Minimize The Effects Of Tissue Impedance, Jeffrey Hargrove Jul 2013

Method And Apparatus For Electrical Stimulation Of Tissues Using Signals That Minimize The Effects Of Tissue Impedance, Jeffrey Hargrove

Mechanical Engineering Patents

A tissue stimulation system that generates an electrical tissue stimulation signal configured to reduce tissue impedance and increase depth of signal penetration. The use of leads is dynamically controlled and altered between conducting biopotential voltages, conducting electrical tissue stimulation signals, and grounding, in response to a computational analysis of biopotential data acquired from a region of tissue to be stimulated.


Surgical Tooling Designed For The Direct Anterior Approach To Total Hip Arthroplasty, Jon-Peter Meckel Jul 2013

Surgical Tooling Designed For The Direct Anterior Approach To Total Hip Arthroplasty, Jon-Peter Meckel

Master's Theses

Surgical Tooling Designed for the Direct Anterior Approach to Total Hip Arthroplasty Jon-Peter Meckel

Total hip arthroplasty (THA) is becoming more and more common in the US as people continue to live longer and more active lives. The main reason that a THA is required is due to the “wear and tear” affliction of osteoarthritis, which in the year 2000 had at least 3% of the population over 30 showing symptoms. A revitalized approach to THA is the direct anterior approach, or Smith-Petersen approach, which limits the amount of musculature affected by the surgery and creates a very stable joint …


Materials Education And Research In Art And Design: A New Role For Libraries (Survey Stats), Mark Pompelia Jun 2013

Materials Education And Research In Art And Design: A New Role For Libraries (Survey Stats), Mark Pompelia

Materials Education and Research in Art and Design: A New Role for Libraries

No abstract provided.


Materials Education And Research In Art And Design: A New Role For Libraries (Program Sheet), Mark Pompelia Jun 2013

Materials Education And Research In Art And Design: A New Role For Libraries (Program Sheet), Mark Pompelia

Materials Education and Research in Art and Design: A New Role for Libraries

No abstract provided.


Materials Education And Research In Art And Design: A New Role For Libraries (Program Booklet), Mark Pompelia Jun 2013

Materials Education And Research In Art And Design: A New Role For Libraries (Program Booklet), Mark Pompelia

Materials Education and Research in Art and Design: A New Role for Libraries

No abstract provided.


Materials Education And Research In Art And Design: A New Role For Libraries (Website), Mark Pompelia Jun 2013

Materials Education And Research In Art And Design: A New Role For Libraries (Website), Mark Pompelia

Materials Education and Research in Art and Design: A New Role for Libraries

No abstract provided.


Materials Collection Creation And Administration: A New Role For Libraries (White Paper), Mark Pompelia Jun 2013

Materials Collection Creation And Administration: A New Role For Libraries (White Paper), Mark Pompelia

Materials Education and Research in Art and Design: A New Role for Libraries

The Problem/Opportunity: To define, identify, and guide design-based materials collections in academic settings and foster community among those with existing collections and/or those considering creating and supporting one.

Contents and topics:

  1. What is a materials collection?
  2. Why have a materials collection?
  3. Acquisition strategies
  4. Organizational approaches
  5. Programming possibilities
  6. Symposium summary
  7. Resources


The Fabrication & Characterization Of An Electrokinetic Microfluidic Pump From Su-8, A Negative Epoxy-Based Photoresist, Nash Anderson Jun 2013

The Fabrication & Characterization Of An Electrokinetic Microfluidic Pump From Su-8, A Negative Epoxy-Based Photoresist, Nash Anderson

Master's Theses

Microfluidics refers to manipulation, precise control, and behavior of fluids at the micro and nanoliter scales. It has entered the realm of science as a way to precisely measure or mix small amounts of fluid to perform highly controlled reactions. Glass and polydimethylsiloxane (PDMS) are common materials used to create microfluidic devices; however, glass is difficult to process and PDMS is relatively hydrophobic. In this study, SU-8, an epoxy based (negative) photoresist was used to create various electrokinetic microfluidic chips. SU-8 is commonly used in microelectromechanical design. Spin coating of various SU-8 formulations allows for 1 μm to 100 μm …


Evaluation Of Corrosion Properties Of Proprietary Metal Alloy Stents For In-Vivo Use, Michael David Bremner Jun 2013

Evaluation Of Corrosion Properties Of Proprietary Metal Alloy Stents For In-Vivo Use, Michael David Bremner

Materials Engineering

To assess corrosion rates of metal alloy bio-absorbable stents an experimental set-up was designed to mimic the coronary artery environment. The artery was modeled using 4mm diameter Tecoflex tubing and the metal alloy stents were inserted into the tubing using a catheter. As is the case in cardiac surgery, the catheter with the stent and a microballoon were maneuvered to the desired position. The microballoon was then slowly inflated to expand the stent and compress it against the tubing walls. The catheter and microballoon were then withdrawn. A circulating pump system was set up to cycle fetal bovine serum (FBS) …


Edwards Lifesciences - Skirt To Frame Attachment Manufacturing Aid, Samuel Joda, Cesar Grimaldo, Patrick Hutchinson Jun 2013

Edwards Lifesciences - Skirt To Frame Attachment Manufacturing Aid, Samuel Joda, Cesar Grimaldo, Patrick Hutchinson

Mechanical Engineering

No abstract provided.


Tracking Points On A Pacing Lead In A Beating Heart, Avinash Ramesh Varma Jun 2013

Tracking Points On A Pacing Lead In A Beating Heart, Avinash Ramesh Varma

Master's Theses

Heart failure is a common condition during which the pumping action of the heart is affected because the heart does not contract or relax properly. Heart failure affects about 5 million Americans, with 550,000 new cases diagnosed each year. Cardiac resynchronization therapy (CRT) is used to treat symptoms and other complications associated with a heart failure. While performing CRT, Implantation of a pacing lead in the left ventricle of the heart is a very challenging surgical procedure performed with fluoroscopy. The target location is often difficult to reach through the tortuous coronary venous anatomy, which varies greatly among individuals. Placement …


Stent Graft Blush, Vanessa Barrett, Thomas Matzinger, Mike Morelli Jun 2013

Stent Graft Blush, Vanessa Barrett, Thomas Matzinger, Mike Morelli

Mechanical Engineering

In order to better understand Type IV endoleaks (“blush”), the Cal Poly Senior Project team GraftTest has developed a blush evaluation system able to mimic several of the aorta’s environmental parameters. Capable of both pressure and flow rate control, this bench top system accommodates Medtronic’s wide range of abdominal and thoracic aortic stent grafts. Having researched endoleaks, stent grafts, and numerous other factors affecting stent graft blush, a system was developed with the aim of assessing and comparing the performance of Medtronic’s stent grafts with regard to blush. Furthermore, this system has been designed to provide reliable and repeatable results …