Full-Text Articles in Biomedical Devices and Instrumentation

Development Of A Pressure Sensing System Coupled With Deployable Machine Learning Models For Assessing Residual Limb Fit In Lower Limb Prosthetics, Maxwell D. Lewter Dec 2024

Development Of A Pressure Sensing System Coupled With Deployable Machine Learning Models For Assessing Residual Limb Fit In Lower Limb Prosthetics, Maxwell D. Lewter

Master's Theses

Lower limb amputations pose significant challenges for patients, with over 150,000 cases annually in the U.S., leading to a high demand for effective prosthetics. However, only 43% of lower limb prosthetic users report satisfaction, primarily due to issues with socket fit, which is critical for comfort, stability, and preventing injury. This study presents a deployable sensing system for potentially real-time monitoring of prosthetic socket fit by using pressure sensors and convolutional neural networks (CNNs) to analyze the pressure distribution within the socket. A novel CNN architecture, utilizing both dilated and strided convolutions, is proposed to effectively capture spatial-temporal patterns in …


Mobilise-D Insights To Estimate Real-World Walking Speed In Multiple Conditions With A Wearable Device, Cameron Kirk, Arne Küderle, M Encarna Micó-Amigo, Tecla Bonci, Anisoara Paraschiv-Ionescu, Martin Ullrich, Abolfazl Soltani, Eran Gazit, Francesca Salis, Lisa Alcock, Kamiar Aminian, Clemens Becker, Stefano Bertuletti, Philip Brown, Ellen Buckley, Alma Cantu, Anne-Elie Carsin, Marco Caruso, Brian Caulfield, Andrea Cereatti, Lorenzo Chiari, Ilaria D'Ascanio, Judith Garcia-Aymerich, Clint Hansen, Jeffrey M Hausdorff, Hugo Hiden, Emily Hume, Alison Keogh, Felix Kluge, Sarah Koch, Walter Maetzler, Dimitrios Megaritis, Arne Mueller, Martijn Niessen, Luca Palmerini, Lars Schwickert, Kirsty Scott, Basil Sharrack, Henrik Sillén, David Singleton, Beatrix Vereijken, Ioannis Vogiatzis, Alison J Yarnall, Lynn Rochester, Claudia Mazzà, Bjoern M Eskofier, Silvia Del Din Jan 2024

Mobilise-D Insights To Estimate Real-World Walking Speed In Multiple Conditions With A Wearable Device, Cameron Kirk, Arne Küderle, M Encarna Micó-Amigo, Tecla Bonci, Anisoara Paraschiv-Ionescu, Martin Ullrich, Abolfazl Soltani, Eran Gazit, Francesca Salis, Lisa Alcock, Kamiar Aminian, Clemens Becker, Stefano Bertuletti, Philip Brown, Ellen Buckley, Alma Cantu, Anne-Elie Carsin, Marco Caruso, Brian Caulfield, Andrea Cereatti, Lorenzo Chiari, Ilaria D'Ascanio, Judith Garcia-Aymerich, Clint Hansen, Jeffrey M Hausdorff, Hugo Hiden, Emily Hume, Alison Keogh, Felix Kluge, Sarah Koch, Walter Maetzler, Dimitrios Megaritis, Arne Mueller, Martijn Niessen, Luca Palmerini, Lars Schwickert, Kirsty Scott, Basil Sharrack, Henrik Sillén, David Singleton, Beatrix Vereijken, Ioannis Vogiatzis, Alison J Yarnall, Lynn Rochester, Claudia Mazzà, Bjoern M Eskofier, Silvia Del Din

Faculty, Staff and Student Publications

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the …


Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina May 2020

Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina

Honors Theses

Collie Box is a medical device that measures the gait parameters of the person walk- ing in front of it. This device uses the Ultrasonic Doppler system to extract the heel-contact and toe-off times of a person walking within the range of 2-10 meters. These times are used to determine the leg’s swing phase and double stance times. The ultrasonic transducer of 10mm diameter is driven at 40kHz. At the time of the heel-contact and toe-off, foot velocity is zero while the torso part of the human body is still in motion. The wide directivity of 10mm diameter ultrasonic transducer …


Knee Joint Loading Following Anterior Cruciate Ligament Reconstruction: Link To Patient Reported Outcomes And A Novel Method To Monitor With Wearable Sensors, Alex Spencer Jan 2020

Knee Joint Loading Following Anterior Cruciate Ligament Reconstruction: Link To Patient Reported Outcomes And A Novel Method To Monitor With Wearable Sensors, Alex Spencer

Theses and Dissertations--Kinesiology and Health Promotion

Recovery from anterior cruciate ligament reconstruction (ACLR) commonly results in undesirable physical and patient-reported outcomes (PROs). Identification of modifiable factors such as knee contact force (KCF) early in rehabilitation that can improve these outcomes is important due to the rapid decrease in function, quality of life, and joint health in this population. Additionally, if noninvasive measurement of KCFs outside of a traditional laboratory were possible, clinicians could optimize patient treatment with personalized care. Therefore, there are two primary aims to this thesis: 1) quantify the link between KCF and PROs which measure pain, ability to perform activities of daily living, …


Altering A Runner’S Foot Strike Using A Modified Elliptical Trainer, Daniel Shull Jan 2017

Altering A Runner’S Foot Strike Using A Modified Elliptical Trainer, Daniel Shull

Theses and Dissertations

One possible solution to common running related injuries is to transition runners from a rearfoot strike during initial contact to a midfoot strike. Natural rearfoot strike runners were studied to see if a modified elliptical trainer could be used to alter their running pattern to that of a midfoot strike runner. Their results were compared to subjects who ran on a non-modified elliptical trainer. After training on the modified elliptical trainer, subjects demonstrated a decrease in foot angle at initial contact when attempting to run with a midfoot strike. Training did not affect all kinetic metrics or stride frequency. However, …


Lpcoms: Towards A Low Power Wireless Smart-Shoe System For Gait Analysis In People With Disabilities, Ishmat Zerin Oct 2015

Lpcoms: Towards A Low Power Wireless Smart-Shoe System For Gait Analysis In People With Disabilities, Ishmat Zerin

Master's Theses (2009 -)

Gait analysis using smart sensor technology is an important medical diagnostic process and has many applications in rehabilitation, therapy and exercise training. In this thesis, we present a low power wireless smart-shoe system (LPcomS) to analyze different functional postures and characteristics of gait while walking. We have designed and implemented a smart-shoe with a Bluetooth communication module to unobtrusively collect data using smartphone in any environment. With the design of a shoe insole equipped with four pressure sensors, the foot pressure is been collected, and those data are used to obtain accurate gait pattern of a patient. With our proposed …


Biplanar Fluoroscopic Analysis Of In Vivo Hindfoot Kinematics During Ambulation, Janelle Ann Cross Jul 2015

Biplanar Fluoroscopic Analysis Of In Vivo Hindfoot Kinematics During Ambulation, Janelle Ann Cross

Dissertations (1934 -)

The overall goal of this project was to develop and validate a biplanar fluoroscopic system and integrated software to assess hindfoot kinematics. Understanding the motion of the foot and ankle joints may lead to improved treatment methods in persons with foot and ankle pathologies. During gait analysis, skin markers are placed on the lower extremities, which are defined as four rigid-body segments with three joints representing the hip, knee and ankle. This method introduces gross assumptions on the foot and severely limits the analysis of in depth foot mechanics. Multi-segmental models have been developed, but are susceptible to skin motion …


Dynamic Balance Control During Treadmill Walking In Chronic Stroke Survivors, Eric Richard Walker Oct 2013

Dynamic Balance Control During Treadmill Walking In Chronic Stroke Survivors, Eric Richard Walker

Dissertations (1934 -)

Maintaining dynamic balance is an important component of walking function that is likely impaired in chronic stroke survivors, evidenced by an increased prevalence of falls. Dynamic balance control requires maintaining the center of mass (COM) within the base of support during movement. During walking, dynamic balance control is achieved largely by modifying foot placement to adjust the base of support. However, chronic stroke survivors have difficulty with both precision control of foot placement, as well as reduced control of COM movement. The objective of this dissertation was to characterize dynamic balance control strategies during walking in chronic stroke survivors. Additionally, …