Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 1 - 30 of 63

Full-Text Articles in Biomedical Devices and Instrumentation

Simulating Pacemakers And Heartbeat Recovery Through Mathematical Modeling, Thomas Estrada, Jayla Edwards Aug 2026

Simulating Pacemakers And Heartbeat Recovery Through Mathematical Modeling, Thomas Estrada, Jayla Edwards

Discovery Day - Daytona Beach

Title: Simulating Pacemakers and Heartbeat Recovery Through Mathematical Modeling   This study utilizes the Fitzhugh-Nagumo model to simulate cardiac electrical activity and the regulatory role of pacemakers through ordinary differential equations (ODEs). By defining the rate of change for membrane voltage, 𝑑𝑣/dt, and a recovery variable, 𝑑𝑤/dt, the model captures the heart's excitability and resting states. Central to the analysis is the stimulus current parameter, which represents the "kick" provided by a pacemaker to correct flatline conditions or weak heartbeats. Using Euler’s method for numerical integration, the research compares unstable cardiac rhythms against corrected periodic oscillations. Additionally, the project implements vector …


Characterizing Stiffness Dynamics Of Normal And Malignant Breast Spheroids Using Brillouin Microscopy, Razanne Rafat Zaghloul, Karlin Hilai, Chenjun Shi, Jitao Zhang May 2026

Characterizing Stiffness Dynamics Of Normal And Malignant Breast Spheroids Using Brillouin Microscopy, Razanne Rafat Zaghloul, Karlin Hilai, Chenjun Shi, Jitao Zhang

Medical Student Research Symposium

Background: Breast cancer progression and metastasis are closely linked to alterations in the mechanical properties of tumor cells and their microenvironment. Softer, more deformable cells are often associated with higher metastatic potential. While atomic force microscopy (AFM) is the current gold standard for mechanical characterization, it is limited to surface measurements and can damage 3D cultures. It remains unclear how the mechanical properties evolve over time in normal versus malignant spheroids. This study utilizes Brillouin light-scattering microscopy, a non-contact and label-free optical technique, to assess stiffness changes in normal and malignant breast epithelial spheroids over time. Understanding these mechanical signatures …


Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao Jan 2026

Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao

Mechanical & Aerospace Engineering Faculty Publications

Aim: This study investigates the feasibility of using radial and carotid arterial pulse signals to assess cardiovascular (CV) function at rest and during post-exercise recovery in a heart transplant (HTx) patient. Method: Two micro-fabricated tactile sensors were used to simultaneously acquire arterial pulse signals at the radial artery (RA) and carotid artery (CA). Measurements were taken at rest and at multiple time points post-exercise on three subjects: an HTx patient, a percutaneous coronary intervention (PCI; coronary stent) patient and a healthy control. An SDOF-TF-based time-frequency analysis algorithm was applied to extract a comprehensive set of CV parameters, including heart rate …


De Novo Protein Binding To Zinc Oxide Through Biomineralization Pathways, Jean-Mark A. Francis Jan 2026

De Novo Protein Binding To Zinc Oxide Through Biomineralization Pathways, Jean-Mark A. Francis

Theses and Dissertations

De novo proteins are structurally distinct from proteins found in nature and thus capable of having their amino acid sequence modified to accomplish tasks such as increasing protein-nanoparticle binding without unfolding or decomposing. Zinc Oxide nanoparticles are functionally distinct from their bulk counterparts and are widely used as semiconductors in a variety of fields such as medicine and agriculture. With demand for these nanoparticles increasing, environmentally sustainable methods of Zinc Oxide nanoparticle synthesis are being investigated as an eco-friendly alternative to currently utilized but environmentally hazardous chemical and physical techniques. This research investigates the binding characteristics between Zinc Oxide nanoparticles …


Synthesis And Study Of Stable Organic Radicals For Mri Contrast Agents And New Materials, Sabina Dhakal Dec 2025

Synthesis And Study Of Stable Organic Radicals For Mri Contrast Agents And New Materials, Sabina Dhakal

Dissertations and Doctoral Documents, University of Nebraska-Lincoln, 2023–

The first part of this dissertation focuses on the design, synthesis, and characterization of a thermally robust S =1/2 phototetrazolinyl monoradical and the development of synthetic methodologies for a high-spin (S = 1) phototetrazolinyl diradical. Electrochemical studies of the phototetrazolium cation (precursor to the monoradical) revealed a remarkably narrow electrochemical band gap (Ecell ≈ 0.82 V), suggesting promising electrical conductivity. Thermal analysis of the monoradical demonstrated excellent stability, with the onset of decomposition at 232 °C. Building on the excellent thermal stability and promising properties for electrical conductivity of the monoradical, we developed two condensation-based synthetic routes that provide viable …


Low-Cost Cutaneous Protoporphyrin Ix (Ppix) Detection (Cpd) Device For Follow-Up Monitoring Of Patients After Photodynamic Therapy, Md Asaduzzaman Rasel Aug 2025

Low-Cost Cutaneous Protoporphyrin Ix (Ppix) Detection (Cpd) Device For Follow-Up Monitoring Of Patients After Photodynamic Therapy, Md Asaduzzaman Rasel

Graduate Masters Theses

Background: Photodynamic Therapy (PDT) utilizes specific wavelengths of light to activate photosensitizing chemical compounds, known as photosensitizers, which induce the generation of cytotoxic reactive oxygen species (ROS) for the targeted destruction of cancer cells. Among various photosensitizers for PDT, Protoporphyrin IX (PpIX) is widely employed in oncology and dermatology due to its natural in situ generation via the metabolic conversion of 5- aminolevulinic acid (ALA), a non-phototoxic prodrug. Systemic administration of ALA after 3-6 hr drug delay leads to peak PpIX accumulation in tissues, facilitating therapeutic and diagnostic applications. However, PpIX can persist in the skin for 24–48 hours post-treatment, …


Design And Development Of A Standalone Digital Holographic Microscope Employing Phase-Driven Reconstruction And Classification For Biomedical Imaging And Optical Diagnostics, Charlotte Kyeremah Aug 2025

Design And Development Of A Standalone Digital Holographic Microscope Employing Phase-Driven Reconstruction And Classification For Biomedical Imaging And Optical Diagnostics, Charlotte Kyeremah

Graduate Doctoral Dissertations

Access to advanced biomedical imaging technologies remains a significant challenge in resource-limited settings, especially for early disease detection and monitoring of diseases such as malaria, HIV, and other blood-borne diseases. Although point-of-care (POC) devices have gained popularity in global health, many rely on antibody-based tests, lateral flow strips, or optical readouts that often lack quantitative capabilities, sensitivity to early infections, or versatility in different diagnostic targets. In addition, these systems are typically dependent on disposable reagents or manual interpretation, which limits their effectiveness in remote areas. Digital Holographic Microscopy (DHM) presents a promising alternative as a label-free imaging method capable …


Volumetric Imaging Of Cellular Dynamics Using Light-Sheet Microscopy: From Subcellular Structures To Whole Organisms, Md Nasful Huda Prince Aug 2025

Volumetric Imaging Of Cellular Dynamics Using Light-Sheet Microscopy: From Subcellular Structures To Whole Organisms, Md Nasful Huda Prince

Optical Science and Engineering ETDs

Advancing biomedical imaging requires platforms that combine high-resolution, speed, and stability across biological scales. This dissertation presents three innovations designed to address limitations of conventional light-sheet and oblique plane imaging. First, we introduce Reflected Inline Detection in Epi-Oblique Plane Microscopy (RIDE-OPM), a compact and drift-resistant system that eliminates a tertiary detection path while maintaining alignment flexibility, enabling robust long-term live imaging. Second, we present a high-speed Axially Swept Light-Sheet Microscopy (ASLM) platform for cleared tissues, using dual foci and synchronized sweeping to achieve isotropic sub-micron resolution at up to 40 frames-per-second, a fourfold improvement over standard ASLM. Integrated with a …


Advancements In Refreshable Braille Display Technology: A Comprehensive Survey, Maryam Etezad, Rajeev Joshi, Franceli L. Cibrian Jun 2025

Advancements In Refreshable Braille Display Technology: A Comprehensive Survey, Maryam Etezad, Rajeev Joshi, Franceli L. Cibrian

Engineering Faculty Articles and Research

This paper provides a comprehensive mapping literature review of the advancements in refreshable Braille display (RBD) technology, which employs dynamically movable pins or dots to render Braille characters for individuals with blindness and visual impairment. This literature review, which includes 96 papers, aims to summarize the current evidence on six distinct types of RBDs: piezoelectric, electromagnetic, electroactive polymer (EAP), pneumatic, shape memory alloy (SMA), and microfluidic technologies. For each type, we discuss the underlying mechanisms, alongside the current trends and research opportunities. This comparative analysis aims to inform the selection of appropriate RBD technology based on specific user needs and …


Impact Of Shear Flow On Marine Biofilms Using Hyperspectral Imaging, Shantanu Mahesh Kore May 2025

Impact Of Shear Flow On Marine Biofilms Using Hyperspectral Imaging, Shantanu Mahesh Kore

All Theses

Various microbial communities in marine biofilms cause biofouling on submerged surfaces, posing challenges to marine industries. Despite their ecological and economic importance, biofilms' biomechanical and biochemical responses to hydrodynamic shear stress are insufficiently understood, particularly in dynamic flow conditions. To fill this gap, our study uses an innovative fiber-optic hyperspectral imaging (HSI) system and a supercontinuum laser source to examine marine biofilms' structure, composition, and detachment behavior at different shear stress levels.

To detect spectral and spatial heterogeneity in live biofilms without labeling, we created a custom imaging pipeline that captures reflectance spectra in the 600-850 nm range, targeting microbial …


Next-Generation Biomedical Implants And Stimuli Responsive Soft Optical Arrays Via Surface Functionalized Elastomeric Materials, John M. Kapitan Apr 2025

Next-Generation Biomedical Implants And Stimuli Responsive Soft Optical Arrays Via Surface Functionalized Elastomeric Materials, John M. Kapitan

Dissertations and Doctoral Documents, University of Nebraska-Lincoln, 2023–

The demands of emerging technologies, such as soft robotics, stretchable electronics, and next generation biomedical implants, has led to the development of diverse polymeric and hybrid organic/inorganic materials specifically tuned to meet these challenges. These materials typically have low Young’s moduli and are inert with high chemical stability. However, this has led to materials that are static in nature, lacking any meaningful way of responding to changes in their environment and adapting to these changes. This has driven a shift towards the design, manufacturing, and characterization of various stimuli responsive surfaces, relying on precise control of surface chemical coatings and …


Development, Optimization, And Validation Of A High-Sensitivity Capillary Zone Electrophoresis System For Bioanalytical Applications, Aaron I. Mena Mar 2025

Development, Optimization, And Validation Of A High-Sensitivity Capillary Zone Electrophoresis System For Bioanalytical Applications, Aaron I. Mena

Electronic Theses and Dissertations

Capillary zone electrophoresis (CZE) is a powerful analytical technique widely used for biomolecular separation due to its high resolution, efficiency, and sensitivity. This report presents the development and validation of a novel CZE system designed to improve modularity, reproducibility, and operational efficiency. The system integrates a laser-induced fluorescence (LIF) detection method with a 488 nm laser, enhanced fluid control through a negative pressure system, and a user-friendly GUI for automated operation and data acquisition. Performance verification included pressure stability tests, fluorescence accuracy assessments, and electrophoretic reproducibility studies. Comparative analysis with a previous CZE iteration confirmed improved baseline stability, peak resolution, …


In Vitro Microfluidics System For Mechanobiologic Investigations, Michael A. Daanen Jan 2025

In Vitro Microfluidics System For Mechanobiologic Investigations, Michael A. Daanen

Honors Theses

Mechanobiology is an emerging field that aims to study the relationships between mechanical forces and cellular behavior. Such mechanobiological relationships are especially critical in the cardiovascular system, where endothelial cells lining the vasculature align in response to fluid shear stresses from blood flow (Sinha, 2016). Implanted flow devices, diabetes, chronic hypertension, and various other diseases and pathophysiologies alter vessel geometries and flow dynamics. Such alterations impact fluid shear stress and endothelial cell behavior, leading to microcirculatory dysfunction, vessel leakage, and organ failure (Poredos, 2021; Papadaki, 1999; Leitschuh, 1987). To simulate dysfunctional endothelial cell behavior in vitro and evaluate novel therapeutic …


An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part I: Accelerometers And Ppg Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao Jan 2025

An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part I: Accelerometers And Ppg Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao

Mechanical & Aerospace Engineering Faculty Publications

This paper, the first of two parts, presents an analytical model of motion artifacts (MAs) in measured pulse signals by accelerometers and photoplethysmography (PPG) sensors. As the transmission path from the true pulse signal in an artery to the sensor output (measured pulse signal), the tissue-contact-sensor (TCS) stack is modeled as a 1DOF (degree-of-freedom) system. MAs cause baseline drift of the mass and simultaneously time-varying system parameters (TVSPs) of the TCS stack. With arterial wall displacement and pulsatile pressure serving separately as the true pulse signal, an analytical model is developed to mathematically relate baseline drift and TVSP to a …


Mechanically Cost-Effective Approach For Bipedal Walking In Robots Using Instantaneous Collision Angle, Smit R. Patel Dec 2024

Mechanically Cost-Effective Approach For Bipedal Walking In Robots Using Instantaneous Collision Angle, Smit R. Patel

UNLV Theses, Dissertations, Professional Papers, and Capstones

Humans, as bipedal locomotors, are effective at reducing the mechanical cost of transport (CoTmech) by adopting movement strategies and gaits that minimize energy expenditure for a given distance. By using different gaits at different speeds, leveraging their long spring-like tendons and muscle elasticity which store and release energy during movement, humans reduce the mechanical effort required for locomotion. Current locomotion solutions offered in bipedal robots, based on legacy walking and running gait models, are not great at energy efficiency unless walking at very low speeds. Additionally, the control system of robots, designed to ensure stability and adaptability, requires substantial resources, …


Database And Machine Learning Model For Classifying Autism Spectrum Disorder From Smartphone Based Electroretinography, Rory Harris May 2024

Database And Machine Learning Model For Classifying Autism Spectrum Disorder From Smartphone Based Electroretinography, Rory Harris

Honors Scholar Theses

Autism Spectrum Disorder (ASD) is a neurodevelopmental disorder that negatively affects a patient’s cognitive and communication aptitude and, therefore, can severely impact that patient’s quality of life. Because of this, early diagnosis is paramount. In recent studies, electroretinography (ERG), which is a measure of the retina’s electrical response to a brief flash of light into the eye, has shown promise in detecting ASD. Access to these scans can provide early diagnosis, improving well-being. Current ERG devices are very expensive due to their on board processing capabilities. This paper aims to create an ERG device using a smartphone as the main …


Implementing Unmanned Aerial Vehicles To Collect Human Gait Data At Distance And Altitude For Identification And Re-Identification, Donn E. Bartram Jan 2024

Implementing Unmanned Aerial Vehicles To Collect Human Gait Data At Distance And Altitude For Identification And Re-Identification, Donn E. Bartram

Graduate Theses, Dissertations, and Problem Reports (ETD)

Gait patterns are a class of biometric information pertaining to the way a person moves and poses. Gait information is unique to each person and can be used to identify and reidentify people. Historically, this task has been achieved through the use of multiple ground-based imaging sensors. However, as Unmanned Aerial Vehicles (UAVs) advance, they present the opportunity to evolve the process of persons identification and re-identification. Collecting human gait data using UAVs at distances ranging from 20m to 500m and altitudes ranging from 0m to 120m is a challenging task. The current biometric data collection methods, primarily designed for …


Compton Scattering Of Mammographic Soft X-Ray Beams By Alkali And Transition Metal Salt Filters Produce X-Ray Interference Zones That May Have Treatment Potential For Localized Cancer Lesions, Subhendra N. Sarkar, Eric Lobel, Sabina Rakhmatova, Derbie Desir, Somdat Kissoon, Daler Djuraev, Katie Tam Jan 2024

Compton Scattering Of Mammographic Soft X-Ray Beams By Alkali And Transition Metal Salt Filters Produce X-Ray Interference Zones That May Have Treatment Potential For Localized Cancer Lesions, Subhendra N. Sarkar, Eric Lobel, Sabina Rakhmatova, Derbie Desir, Somdat Kissoon, Daler Djuraev, Katie Tam

Publications and Research

In breast x-ray imaging scattered radiation adds 50% of harmful radiation dose from anisotropic Compton scattering mechanism. We have been working with double layered inorganic salt materials that can induce Compton scattering to the incident mammographic x ray beams (in 20-30 kVp range) with adequate isotropy (angular control). Typically metal nitrates and alkali halide salt layers are shown here to cause low energy radiation interference zones with high and low photon intensities and local flux heterogeneity in terms of flux covariance. Spatial variation of low energy photon flux creates concentrated and sparse radiation zones that may be used to induce …


Construction And Performance Optimization Of Bioconjugated Nanosensors For Early Detection Of Breast Cancer And Pro-Inflammatory Diseases, Pooja Gaikwad Sep 2023

Construction And Performance Optimization Of Bioconjugated Nanosensors For Early Detection Of Breast Cancer And Pro-Inflammatory Diseases, Pooja Gaikwad

Dissertations, Theses, and Capstone Projects

In recent years, nanosensors have emerged as a tool with strong potential in medical diagnostics. Single-walled carbon nanotube (SWCNT) based optical nanosensors have notably garnered interest due to the unique characteristics of their near-infrared fluorescence emission, including tissue transparency, photostability, and various chiralities with discrete absorption and fluorescence emission bands. Additionally, the optoelectronic properties of SWCNT are sensitive to the surrounding environment, which makes them suitable for in vitro and in vivo biosensing. Single-stranded (ss) DNA-wrapped SWCNTs have been reported as optical nanosensors for cancers and metabolic diseases. Breast cancer and cardiovascular diseases are the most common causes of death …


Characterization And Estimation Of Musculoskeletal Pain Using Machine Learning, Boluwatife Faremi Jul 2023

Characterization And Estimation Of Musculoskeletal Pain Using Machine Learning, Boluwatife Faremi

Master's Theses

Traditional scales utilized for recording pain are known to be highly subjective and biased due to inaccuracies in recollecting actual pain intensities. As a result, machine learning (ML) models that are trained using these scores as ground truth are reported to have low performance for objective pain classification because of the huge disparity between what was felt in moments of pain and the scores recorded afterward.

In the present study, two devices were designed for gathering real-time, continuous in-session subjective pain scores and the recording of the autonomic nervous system (ANS) altered endodermal (EDA) activity. 24 participants were recruited to …


Patient Movement Monitoring Based On Imu And Deep Learning, Mohsen Sharifi Renani Jun 2023

Patient Movement Monitoring Based On Imu And Deep Learning, Mohsen Sharifi Renani

Electronic Theses and Dissertations

Osteoarthritis (OA) is the leading cause of disability among the aging population in the United States and is frequently treated by replacing deteriorated joints with metal and plastic components. Developing better quantitative measures of movement quality to track patients longitudinally in their own homes would enable personalized treatment plans and hasten the advancement of promising new interventions. Wearable sensors and machine learning used to quantify patient movement could revolutionize the diagnosis and treatment of movement disorders. The purpose of this dissertation was to overcome technical challenges associated with the use of wearable sensors, specifically Inertial Measurement Units (IMUs), as a …


The Study Of Corrosion On Additive-Manufactured Metals., Braydan Daniels May 2023

The Study Of Corrosion On Additive-Manufactured Metals., Braydan Daniels

Electronic Theses and Dissertations

The purpose of this study was to investigate and compare the corrosion mechanisms between wrought and additive-manufactured (3D-printed) copper and stainless steel. The experimental procedure consisted of measuring the open circuit potential, electrochemical impedance spectroscopy, linear sweep voltammetry, Tafel analysis, surface topology, and scanning electron microscopy for each metal within salt water, tap water, sulfuric acid, and synthetic body fluid (excluding copper in synthetic body fluid).

Overall, printed stainless steel was more corrosion-resistant than wrought stainless steel in tap water and synthetic body fluid based on OCP, LSV, and surface topology results. Additionally, printed copper was more corrosion-resistant than wrought …


Predicting Insulin Pump Therapy Settings, Riccardo L. Ferraro, David Grijalva, Alex Trahan Sep 2022

Predicting Insulin Pump Therapy Settings, Riccardo L. Ferraro, David Grijalva, Alex Trahan

SMU Data Science Review

Millions of people live with diabetes worldwide [7]. To mitigate some of the many symptoms associated with diabetes, an estimated 350,000 people in the United States rely on insulin pumps [17]. For many of these people, how effectively their insulin pump performs is the difference between sleeping through the night and a life threatening emergency treatment at a hospital. Three programmed insulin pump therapy settings governing effective insulin pump function are: Basal Rate (BR), Insulin Sensitivity Factor (ISF), and Carbohydrate Ratio (ICR). For many people using insulin pumps, these therapy settings are often not correct, given their physiological needs. While …


Porous Silicon Photonics For Label-Free Interferometric Biosensing And Flat Optics, Tahmid Hassan Talukdar May 2022

Porous Silicon Photonics For Label-Free Interferometric Biosensing And Flat Optics, Tahmid Hassan Talukdar

All Dissertations

This dissertation uses porous silicon as a material platform to explore novel optical effects in three domains: (i) It studies dispersion engineering in integrated waveguides to achieve high performance group index sensing. With proper design parameters, the sensor waveguides can theoretically achieve 6 times larger group index shift compared to the actual bulk effective refractive index shift. We demonstrate the guided mode confinement factor to be a key parameter in design and implementation of these waveguides. (ii) It explores multicolor laser illumination to experimentally demonstrate perceptually enhanced colorimetric sensing, overcoming the limitations faced by many contemporary colorimetric sensors. Our technique …


Radiomic Features To Predict Overall Survival Time For Patients With Glioblastoma Brain Tumors Based On Machine Learning And Deep Learning Methods, Lina Chato May 2022

Radiomic Features To Predict Overall Survival Time For Patients With Glioblastoma Brain Tumors Based On Machine Learning And Deep Learning Methods, Lina Chato

UNLV Theses, Dissertations, Professional Papers, and Capstones

Machine Learning (ML) methods including Deep Learning (DL) Methods have been employed in the medical field to improve diagnosis process and patient’s prognosis outcomes. Glioblastoma multiforme is an extremely aggressive Glioma brain tumor that has a poor survival rate. Understanding the behavior of the Glioblastoma brain tumor is still uncertain and some factors are still unrecognized. In fact, the tumor behavior is important to decide a proper treatment plan and to improve a patient’s health. The aim of this dissertation is to develop a Computer-Aided-Diagnosis system (CADiag) based on ML/DL methods to automatically estimate the Overall Survival Time (OST) for …


Volume Introduction, I. Glenn Cohen, Timo Minssen, W. Nicholson Price Ii, Christopher Robertson, Carmel Shachar Mar 2022

Volume Introduction, I. Glenn Cohen, Timo Minssen, W. Nicholson Price Ii, Christopher Robertson, Carmel Shachar

Other Publications

Medical devices have historically been less regulated than their drug and biologic counterparts. A benefit of this less demanding regulatory regime is facilitating innovation by making new devices available to consumers in a timely fashion. Nevertheless, there is increasing concern that this approach raises serious public health and safety concerns. The Institute of Medicine in 2011 published a critique of the American pathway allowing moderate-risk devices to be brought to the market through the less-rigorous 501(k) pathway,1 flagging a need for increased postmarket review and surveillance. High-profile recalls of medical devices, such as vaginal mesh products, along with reports globally …


Synthesis Of Thiol-Acrylate Hydrogels For 3d Cell Culture And Microfluidic Applications, Anowar Hossain Khan Mar 2022

Synthesis Of Thiol-Acrylate Hydrogels For 3d Cell Culture And Microfluidic Applications, Anowar Hossain Khan

LSU Doctoral Dissertations

Globally cell culture is an $18.98 billion industry as of 2020, with an 11.6 percent annual growth rate. Drug discovery has an estimated worth of $69.8 billion in 2020 and is predicted to grow to $110.4 billion by 2025. Three-dimensional (3D) cell culture of cancer cells is one of the rapidly growing felids since it better recapitulates in vivo conditions compared to two-dimensional (2D) models. However, it is challenging to grow 3D tumor spheroids outside the body, and some of the existing technology can generate these spheroids outside the human body but poorly mimic in vivo tumor models. Therefore, there …


Part I - Ai And Data As Medical Devices, W. Nicholson Price Ii Jan 2022

Part I - Ai And Data As Medical Devices, W. Nicholson Price Ii

Other Publications

It may seem counterintuitive to open a book on medical devices with chapters on software and data, but these are the frontiers of new medical device regulation and law. Physical devices are still crucial to medicine, but they – and medical practice as a whole – are embedded in and permeated by networks of software and caches of data. Those software systems are often mindbogglingly complex and largely inscrutable, involving artificial intelligence and machine learning. Ensuring that such software works effectively and safely remains a substantial challenge for regulators and policymakers. Each of the three chapters in this part examines …


Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle Aug 2021

Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle

PANDION: The Osprey Journal of Research and Ideas

Positron Emission Tomography (PET) scans can utilize a radioactive tracer, in this case 2-deoxy2-[fluorine-18] fluoro-D-glucose (18F-FDG), to visualize malignant tumors in cancer patients. The uptake was compared to glucose to understand the difference in thermal properties, which contribute to the ability to image the cancerous cells. The uptake of 18F-FDG by cancer cells and the imaging process of positron emission tomography were reviewed from a thermodynamic perspective. Gastrointestinal and neurological imaging techniques were reviewed to understand the role of PET imaging in different areas of the human body.


Design And Control Of A Peristaltic Pump To Simulate Left Atrial Pressure In A Conductive Silicone Model, Jeremy Collins May 2021

Design And Control Of A Peristaltic Pump To Simulate Left Atrial Pressure In A Conductive Silicone Model, Jeremy Collins

Mechanical Engineering Undergraduate Honors Theses

According to the CDC, atrial fibrillation is responsible for more than 454,000 hospitalizations and approximately 158,000 deaths per year. A common treatment for atrial fibrillation is catheter ablation, a process in which a long flexible tube is guided through the femoral artery and to the source of arrhythmia in the heart, where it measures the electrical potential at various locations and converts problematic heart tissue to scar tissue via ablation. This paper details the design and control of a low-cost ($400) peristaltic pump system using repetitive control to replicate blood pressure in the left atrium in a conductive silicone model …