Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Electrical and Computer Engineering (3)
- Mechanical Engineering (3)
- Biomechanical Engineering (2)
- Biomedical (2)
- Electrical and Electronics (2)
-
- Applied Mechanics (1)
- Computer Engineering (1)
- Computer-Aided Engineering and Design (1)
- Controls and Control Theory (1)
- Electro-Mechanical Systems (1)
- Manufacturing (1)
- Operations Research, Systems Engineering and Industrial Engineering (1)
- Robotics (1)
- Systems Engineering (1)
- Systems and Integrative Engineering (1)
- Keyword
-
- EIM (2)
- Impedance (2)
- Polypectomy (2)
- Snare (2)
- Bio-Medical Engineering (1)
-
- Bio-impedance spectroscopy torso SFB7 fluid level (1)
- Control Systems (1)
- Crest factor (1)
- EMG (1)
- ETD (1)
- Electrosurgical Unit (ESU) (1)
- FEM (1)
- Feedback Control (1)
- Feedback control (1)
- Genetic Algorithm (1)
- Genetic algorithm (1)
- Mechanism design (1)
- Mechatronics (1)
- Muscle (1)
- Neuromuscular (1)
- Optimized Electrode Configuration (1)
- Orthopedics (1)
- Power (1)
- Radiofrequency ablation (1)
- Surgical Instrumentation (1)
- Voltage (1)
Articles 1 - 7 of 7
Full-Text Articles in Biomedical Devices and Instrumentation
Viscoelastic Property Analysis Of A Magnetorheological Elastomer Micropump For Insulin Delivery In Type 1 Diabetes, Victor Buitimea
Viscoelastic Property Analysis Of A Magnetorheological Elastomer Micropump For Insulin Delivery In Type 1 Diabetes, Victor Buitimea
College of Graduate Studies: Theses & Dissertations
Over two decades, there has been a significant rise in awareness regarding Type 1 Diabetes (T1D), leading to a deeper comprehension of numerous variables, including hereditary factors, patterns of occurrence, and health challenges. According to the Type 1 Diabetic Index, around 8.7 million people worldwide are affected by this chronic autoimmune illness marked by a lack of insulin and hyperglycemia. The introduction of artificial pancreas systems could save more than half a million patients by 2040. Despite the availability of various insulin delivery technologies that are offered to diabetic patients, many still are skeptical of this modern system. The issues …
Design And Fabrication Of A Force-Displacement Control Mechanism For Bone-Surgical Tool Testing, Kenneth Nwagu
Design And Fabrication Of A Force-Displacement Control Mechanism For Bone-Surgical Tool Testing, Kenneth Nwagu
College of Graduate Studies: Theses & Dissertations
This project focuses on the design and fabrication of an experimental setup for orthopedic-tool testing, tailored for a surgical instrumentation company. The multifaceted project encompasses a literature review, conceptual design, prototyping, and rigorous testing, resulting in a versatile control system capable of assessing various orthopedic tools, including bone drills, saws, burrs, and power handpieces.
Orthopedic surgical procedures (which include cutting and/or drilling into bone) often need to be performed on bones for faster recovery. The drilling and cutting process can cause an increase in temperature at the cutting site which can cause bone necrosis. The tools also need to be …
Controlled Voltage Of Hot Snare Polypectomy Device In Electrosurgical Device, Saidi Olayinka Olalere
Controlled Voltage Of Hot Snare Polypectomy Device In Electrosurgical Device, Saidi Olayinka Olalere
College of Graduate Studies: Theses & Dissertations
The study is used to understand the working procedure of the Olympus PSD-30 Electrosurgical Unit which a high-frequency alternating current is to measure the voltage and power output from the unit when used for a surgical operation to determine the extent of tissue damage. The output power and voltage were as examined with the stopwatch, then with an Arduino time based for 1, 2, and 3 seconds to understand the different modes of the cut and coagulation feedback with an RCC circuit used to mimic the human body. This shows a pattern in which the feedback power increases, and voltage …
Fluid Shift And Fluid Resuscitation In Burn Patients With The Use Of Bio-Electrical Impedance Spectroscopy To Monitor Fluid Levels, Temitope D. Obielodan
Fluid Shift And Fluid Resuscitation In Burn Patients With The Use Of Bio-Electrical Impedance Spectroscopy To Monitor Fluid Levels, Temitope D. Obielodan
Honors College Theses
The purpose of this research is to explore the current methods of fluid resuscitation and other possible methods of measuring the body fluid levels of burn patients in order to fully understand the fluid increase patterns in the torso area. This will be done primarily by focusing on the concept of bio-electrical impedance spectroscopy to measure the fluid levels only in the human torso area. Three similar tests were carried out by measuring the resistance values after ingesting 500ml of water. This was repeated until a total of 1500ml of water was ingested. It was found that the resistance in …
Development Of An Impedance-Controlled Hot Snare Polypectomy Device To Minimize Tissue Damage, Curtislee Thornton
Development Of An Impedance-Controlled Hot Snare Polypectomy Device To Minimize Tissue Damage, Curtislee Thornton
College of Graduate Studies: Theses & Dissertations
This study explores the ability to measure the changing impedance, ex vivo, of a porcine colon sample while undergoing a high-frequency alternating current from an Olympus PSD-30 electrosurgical unit and stop the applied current before excessive tissue damage ensues. The causes of the thermal damage are first examined, followed by the construction and testing of the impedance-controlled feedback device. Perforation was observed to occur when the impedance of the tissue sample increased by 25% or more. Using this information, the device was tested for five power settings ranging from 10W-50W. In each trial, the feedback device stopped the applied current …
Assessment Of Optimized Electrode Configuration In Electrical Impedance Myography Study Using Genetic Algorithm Via Finite Element Model, Somen Baidya
College of Graduate Studies: Theses & Dissertations
Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and …
Assessment Of Electrode Configurations Of Electrical Impedance Myography For The Evaluation Of Neuromuscular Diseases, Khondokar Mohammad Fazle Rabbi
Assessment Of Electrode Configurations Of Electrical Impedance Myography For The Evaluation Of Neuromuscular Diseases, Khondokar Mohammad Fazle Rabbi
College of Graduate Studies: Theses & Dissertations
Electrical impedance myography (EIM) is a painless, noninvasive approach to measure the neuromuscular disease status. EIM parameters- resistance (R), reactance (X) and phase (θ) depend significantly on subcutaneous fat thickness, muscle size and inter electrode distance. The objective of this research is to find an electrode configuration which can minimize the effects on EIM parameters due to subcutaneous fat thickness variation. In this study, a model of human upper arm was developed using finite element method (FEM), which has already been established as an appropriate approach for the analysis of non-symmetrical shape for assessing alternations of muscle in disease-induced changes …