Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (236)
- Electrical and Computer Engineering (177)
- Chemical Engineering (170)
- Mechanical Engineering (170)
- Biochemical and Biomolecular Engineering (147)
-
- Biomedical (121)
- Bioimaging and Biomedical Optics (101)
- Biomechanical Engineering (101)
- Other Biomedical Engineering and Bioengineering (101)
- Biomaterials (91)
- Biomechanics and Biotransport (91)
- Life Sciences (89)
- Bioelectrical and Neuroengineering (77)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (71)
- Molecular, Cellular, and Tissue Engineering (63)
- Physical Sciences and Mathematics (63)
- Medical Specialties (60)
- Biological Engineering (51)
- Electrical and Electronics (51)
- Materials Science and Engineering (50)
- Systems and Integrative Engineering (49)
- Computer Engineering (45)
- Signal Processing (39)
- Rehabilitation and Therapy (38)
- Medical Sciences (36)
- Diseases (34)
- Electro-Mechanical Systems (29)
- Institution
-
- California Polytechnic State University, San Luis Obispo (213)
- Missouri University of Science and Technology (131)
- University of Arkansas, Fayetteville (69)
- The University of Akron (48)
- University of Nebraska - Lincoln (45)
-
- Purdue University (39)
- University of Nevada, Las Vegas (32)
- Technological University Dublin (27)
- Marquette University (26)
- City University of New York (CUNY) (25)
- University of Kentucky (25)
- Dartmouth College (24)
- Old Dominion University (24)
- Virginia Commonwealth University (22)
- University of Louisville (21)
- Clemson University (19)
- University of Mississippi (19)
- University of Connecticut (17)
- Kettering University (16)
- Michigan Technological University (15)
- University of Denver (14)
- Brigham Young University (11)
- West Virginia University (11)
- Louisiana State University (10)
- Washington University in St. Louis (10)
- Duquesne University (9)
- Embry-Riddle Aeronautical University (9)
- University of Malaya (9)
- Cleveland State University (7)
- Georgia Southern University (7)
- Keyword
-
- Microfluidics (34)
- Biomechanics (14)
- Biomedical Engineering (14)
- Biomedical (13)
- Biomedical engineering (13)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (13)
- Machine learning (12)
- Prosthetic (12)
- Cancer (11)
- Device (11)
- Engineering (11)
- Machine Learning (11)
- Prosthetics (11)
- Medical device (10)
- Surgery (10)
- Biomaterials (9)
- Electrophysiology (9)
- Kinematics (9)
- 3D printing (8)
- Applied sciences (8)
- Biosensor (8)
- Diagnostics (8)
- Gait (8)
- Mechanical and Materials Engineering (8)
- Sensor (8)
- Ultrasound (8)
- Wearable (8)
- Arduino (7)
- Bone (7)
- Breast cancer (7)
- Publication Year
- Publication
-
- Chemical and Biochemical Engineering Faculty Research & Creative Works (131)
- Master's Theses (98)
- Biomedical Engineering (79)
- Williams Honors College, Honors Research Projects (47)
- Electronic Theses and Dissertations (42)
-
- Graduate Theses and Dissertations (32)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (30)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (28)
- Biomedical Engineering Undergraduate Honors Theses (25)
- Theses and Dissertations (25)
- Honors Theses (22)
- Mechanical Engineering (22)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (17)
- Master's Theses (2009 -) (17)
- Theses and Dissertations--Biomedical Engineering (17)
- Conference Papers (16)
- Dissertations, Master's Theses and Master's Reports (15)
- Dissertations and Theses (12)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (11)
- Mechanical Engineering Patents (11)
- All Dissertations (10)
- Biomedical Engineering Western Regional Conference (10)
- Dartmouth College Ph.D Dissertations (10)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (10)
- Publications and Research (10)
- All Theses (9)
- Dissertations (1934 -) (9)
- Student Works (2020-2029) (9)
- Honors Scholar Theses (8)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (7)
- Publication Type
- File Type
Articles 961 - 990 of 1146
Full-Text Articles in Biomedical Devices and Instrumentation
Modeling Hrtf For Sound Localization In Normal Listeners And Bilateral Cochlear Implant Users, Douglas A. Miller
Modeling Hrtf For Sound Localization In Normal Listeners And Bilateral Cochlear Implant Users, Douglas A. Miller
Electronic Theses and Dissertations
Mathematical models can be very useful for understanding complicated systems and for testing algorithms through simulation that would be difficult or expensive to implement. This dissertation presents a model that attempts to simulate the sound localization performance of persons using bilateral cochlear implants. The expectation is that this model could prove to be a useful tool in developing new signal processing algorithms for neural encoding strategies.
The head related transfer function (HRTF) is a critical component of this model, and in the ideal case, provides the base characteristics of head shadow, torso and pinna effects. This defines the temporal, intensity …
Diagnosis Of Systemic Inflammation Using Transendothelial Electrical Resistance And Low-Temperature Co-Fired Ceramic Materials, William L. Mercke
Diagnosis Of Systemic Inflammation Using Transendothelial Electrical Resistance And Low-Temperature Co-Fired Ceramic Materials, William L. Mercke
Theses and Dissertations--Chemical and Materials Engineering
Systemic inflammation involves a complex array of cytokines that can result in organ dysfunction. Mortality remains high despite the vast amount of research conducted to find an effective biomarker. The cause of systemic inflammation can be broad and non-specific; therefore, this research investigates using transendothelial electrical resistance (TEER) measurements to better define systemic inflammatory response syndrome (SIRS)/sepsis within a patient. Results show a difference in TEER measurements between healthy individuals and SIRS-rated patients. This research also displays correlations between TEER measurements and biomarkers currently studied with systemic inflammation (tumor necrosis factor-α, C- reactive protein, procalcitonin). Furthermore, this research also presents …
Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao
Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao
Theses and Dissertations--Electrical and Computer Engineering
In immersive audio environments with distributed microphones, Independent Component Analysis (ICA) can be applied to uncover signals from a mixture of other signals and noise, such as in a cocktail party recording. ICA algorithms have been developed for instantaneous source mixtures and convolutional source mixtures. While ICA for instantaneous mixtures works when no delays exist between the signals in each mixture, distributed microphone recordings typically result various delays of the signals over the recorded channels. The convolutive ICA algorithm should account for delays; however, it requires many parameters to be set and often has stability issues. This thesis introduces the …
Biomechanical Comparison Of Lower Limb Unloading Between Common Modalities Of Ankle Foot Orthoses, Andrea Blake Wanamaker
Biomechanical Comparison Of Lower Limb Unloading Between Common Modalities Of Ankle Foot Orthoses, Andrea Blake Wanamaker
Electronic Theses and Dissertations
Tibial stress fractures and other lower extremity injuries can be treated using an ankle foot orthosis (AFO). AFOs are popular because they allow the patient to ambulate somewhat naturally while reducing weight bearing on the injured limb. Despite their popularity, it is currently unclear how well AFOs reduce lower extremity weight bearing.
The first objective of this investigation was to examine the ability of three commonly used ankle foot orthoses to reduce weight bearing within the lower limb by comparing the ground reaction force measured from a force platform to the force measured from an insole pressure measurement device inside …
Computational Representation Of The Patellofemoral Joint, Abraham Wright
Computational Representation Of The Patellofemoral Joint, Abraham Wright
Electronic Theses and Dissertations
Many people suffer from knee pain due to abnormal function of the patellofemoral joint and are not able to enjoy normal activities of daily living. Surgical treatments are available and new methods are being developed by the medical industry. However, computational tools to efficiently evaluate the effects of the intervention on patellofemoral function are lacking.
Therefore, a validated and efficient computational model of the patellofemoral joint was developed. The subject specific finite element model was validated against the patellar kinematics recorded during cadaveric patellofemoral laxity experiments of the natural knee. The development involved a sequential process in which the soft-tissue …
Fabrication Of Cao-Nao-Sio2/Tio2 Scaffolds For Surgical Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler
Fabrication Of Cao-Nao-Sio2/Tio2 Scaffolds For Surgical Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
A series of titanium (Ti) based glasses were formulated (0.62 SiO2-0.14 Na2O-0.24 CaO, with 0.05 mol% TiO2 substitutions for SiO2) to develop glass/ceramic scaffolds for bone augmentation. Glasses were initially characterised using X-ray diffraction (XRD) and particle size analysis, where the starting materials were amorphous with 4.5 μm particles. Hot stage microscopy and high temperature XRD were used to determine the sintering temperature (̃700 °C) and any crystalline phases present in this region (Na2Ca3Si6O16, combeite and quartz). Hardness testing revealed that the Ti-free control (ScC- …
Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat
Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat
Master's Theses
MEASURING IMPEDANCE OF TISSUES USING A MICROFABRICATED MICROELECTRODE ARRAY By Ashwini Bhat
This thesis looks at the possibility of using impedance spectroscopy for differentiating tissue, using a microelectrode array (MEA). The thesis first discusses the background and the motivation for this thesis. It covers the certain basic concepts of the human skin starting from the top epidermis layer all the way to the deep dermis layers of the skin. Then it discusses different types of skin cancer and how they occur, in humans. It also discusses various microfabrication techniques such as oxidation, wet etching, sputtering and photolithography for the creation …
On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming
On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming
Department of Mechanical and Materials Engineering: Faculty Publications
The stent-artery interactions have been increasingly studied using the finite element method for better understanding of the biomechanical environment changes on the artery and its implications. However, the deployment of balloon-expandable stents was generally simplified without considering the balloon-stent interactions, the initial crimping process of the stent, its overexpansion routinely used in the clinical practice, or its recoil process. In this work, the stenting procedure was mimicked by incorporating all the above-mentioned simplifications. The impact of various simplifications on the stent-induced arterial stresses was systematically investigated. The plastic strain history of stent and its resulted geometrical variations, as well as …
Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel
Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel
Mechanical Engineering
This report covers the design and construction of the recumbent racing tricycle for Mr. Robert T. Kelly, a disabled veteran. Unfortunately Rob’s right leg is five inches shorter than his left one and therefore is unable to properly operate standard cranks. Our team HandiTrike is composed of Sean Higginson, Kevin Howie, and Vinay Patel and our project requires us to come up with a design that is feasible to complete within the given three quarters, as well as allow Rob to gain full use of his tricycle. Currently Rob ‘s trike uses the standard crank set up found on most …
Morphometric, Biochemical, And Raman Spctral Analyses Of Muscle Damage In Patients With Peripheral Arterial Disease: Provising Objective Criteria For Diagnosis And Treatment Monitoring, Kim Cluff
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Peripheral arterial disease (PAD), which affects approximately 10 million Americans, is characterized by atherosclerosis of the non-coronary arteries. PAD produces a progressive accumulation of ischemic injury to the limbs that is reflected in a gradual worsening in the myofiber morphology and oxidative damage in the gastrocnemius muscle. In this study, we evaluated the hypothesis that quantitative morphological and biochemical parameters of gastrocnemius myofibers change in a consistent manner during the progression of PAD, provide an objective grading of muscle degeneration in the ischemic limb, and correlate to clinical stage of PAD. Myofiber morphometrics were determined precisely with mathematical equations that …
Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee
Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee
Master's Theses
Off-label use of traditional Oropharyngeal Airway (OPA) as a bite-block, and the subsequential procedure of force exertion of the device by physician has caused many cases of patient’s teeth damage and monetary loss, as the patient’s incisors were damaged while clenching on the OPA during an adverse scenario called “Emergency Clenching”. To remedy this harmful situation, Bardo OPA was developed by Dr. Theodore Burdumy. The Bardo airway has unique design to transfer the clenching force from incisor to the molar. However, the Bardo OPA is one-sized, and cannot fit most of the patients like the commonly-used OPAs, such as the …
Compression Transmission Collar For Fastening, Patrick Atkinson
Compression Transmission Collar For Fastening, Patrick Atkinson
Mechanical Engineering Patents
A compression transmission collar apparatus (20) for implantation into a bone (22) with a hole (28) having a hole wall (32) comprising an intramedullary nail (34) defining a bore (40) and a threaded fastener (42) and a compression transmission collar (58) including an exterior face (64) and a top edge (60) and a bottom edge (62) and a first end (70) intersecting the top edge (60) at an acute angle (α1) and …
Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier
Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier
Mechanical Engineering Patents
An intramedullary nail (20) for insertion into the medullary canal (26) in a bone (24) surrounded by the cortex (28) and defines a bore (34) extending transverse to the intramedullary nail (20). A threaded fastener (22) extends along a fastener axis (A) and has a compression portion (48) having a compression portion diameter (DCP), and a threaded portion (50) having a threaded portion diameter (DTP) extending through a near cortex hole (40) and a far cortex hole (42), both holes (40, 42) radially overlapping the bore (34) and the threaded portion diameter (DTP) threadedly engaging the bore (34). A compression …
Method And Apparatus For Utilizing Amplitude-Modulated Pulse-Width Modulation Signals For Neurostimulation And Treatment Of Neurological Disorders Using Electrical Stimulation, Jeffrey Hargrove, Theodore Stokes, Mary L. Esty
Method And Apparatus For Utilizing Amplitude-Modulated Pulse-Width Modulation Signals For Neurostimulation And Treatment Of Neurological Disorders Using Electrical Stimulation, Jeffrey Hargrove, Theodore Stokes, Mary L. Esty
Mechanical Engineering Patents
A computing device-controlled system is described for the generation of amplitude-modulated pulse-width modulation (AMPWM) signals for use in treating neurological dysfunction via cranial neurostimulation, where the AMPWM signal is specifically designed to minimize the electrical impedance of the tissues of the head. A low-frequency carrier signal is determined for the AMPWM signal by measuring EEG activity at a reference site or sites, generally corresponding with the location of suspected brain dysfunction. Carrier signal frequency is variably related to critical frequency components of the EEG power spectral density, determined from statistical analysis of amplitudes and variability, and dynamically changed as a …
A Low Cost Motion Analysis System Based On Kinect, Jonathan Michael Cardinale, Tracy N. Jennemann, Vitaliy Sinyuk, Sam Kenji Yokoyama
A Low Cost Motion Analysis System Based On Kinect, Jonathan Michael Cardinale, Tracy N. Jennemann, Vitaliy Sinyuk, Sam Kenji Yokoyama
Undergraduate Research Posters 2012
The project focused on the validation of using the Kinect sensor to build a low cost motion analysis system for physical therapy and rehabilitation, and the identification of the types of the motions that cannot be captured well by the Kinect sensor and are in need of inertial sensors.
Developing Novel Prognostic Biomarkers For Multivariate Fracture Risk Prediction Algorithms, Ernest K. Poku, Mark R. Towler, Niamh M. Cummins, Jeff D. Newman
Developing Novel Prognostic Biomarkers For Multivariate Fracture Risk Prediction Algorithms, Ernest K. Poku, Mark R. Towler, Niamh M. Cummins, Jeff D. Newman
Chemical and Biochemical Engineering Faculty Research & Creative Works
Multivariate prediction algorithms such as FRAX® and QFracture Scores provide an opportunity for new prognostic biomarkers to be developed and incorporated, potentially leading to better fracture prediction. As more research is conducted into these novel biomarkers, a number of factors need to be considered for their successful development for inclusion in these algorithms. In this review, we describe two well-known multivariate prediction algorithms for osteoporosis fracture risk applicable to the UK population, FRAX and QFracture Scores, and comment on the current prognostic tools available for fracture risk; dual X-ray assessment, quantitative ultrasonography, and genomic/biochemical markers. We also highlight the factors …
Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar
Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar
Master's Theses
A continuous flow, passive separation device was designed using an equivalent circuit to create variable flow rates for hydrodynamic focusing to drain channels and collection outlets. By varying the diameter of the sample inlet connection into the reservoir, the particle position was influenced significantly, which enabled desired separations. Additionally it was noted that the relative, horizontal position of the inlet also had a significant influence on particle position within the device. A dimensionless number, the Characteristic Sample Inlet, was developed to relate geometric properties of the inlet reservoir to downstream particle distribution. It was found that a 2:1 ratio between …
Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam
Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam
Master's Theses
The following paper describes a fall detection and activity monitoring system with position detection based on Zigbee transceivers.The main objective is to reduce the time taken for emergency personnel to respond to falls among the elderly. Especially when the victim is unconscious or delirious, position tracking reduces location determination time within a busy hospital or nursing home environment and facilitates immediate treatment. Reduced response times correlate to decreased morbidity and mortality rates. Background is provided on the major wireless network advances currently deployed in a healthcare setting for asset and personnel tracking, etiology of falls, and several methods of detecting …
Gallium Containing Glass Polyalkenoate Anti-Cancerous Bone Cements: Glass Characterization And Physical Properties, A. W. Wren, A. Coughlan, L. Placek, Mark R. Towler
Gallium Containing Glass Polyalkenoate Anti-Cancerous Bone Cements: Glass Characterization And Physical Properties, A. W. Wren, A. Coughlan, L. Placek, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
A gallium (Ga) glass series (0.48SiO2-0.40ZnO-0.12CaO, with 0.08 mol% substitution for ZnO) was developed to formulate a Ga-containing Glass Polyalkenoate Cement (GPC) series. Network connectivity (NC) and X-ray Photoelectron Spectroscopy (XPS) was employed to investigate the role of Ga3+ in the glass, where it is assumed to act as a network modifier. Ga-GPC series was formulated with E9 and E11 polyacrylic acid (PAA) at 50, 55 and 60 wt% additions. E11 working times (Tw) ranged from 68 to 96 s (Lcon.) and 106 s for the Ga-GPCs (LGa-1 and LGa-2). Setting times (Ts) …
Experimental Composite Guidance Conduits For Peripheral Nerve Repair: An Evaluation Of Ion Release, X. F. Zhang, A. Coughlan, H. O'Shea, Mark R. Towler, S. Kehoe, D. Boyd
Experimental Composite Guidance Conduits For Peripheral Nerve Repair: An Evaluation Of Ion Release, X. F. Zhang, A. Coughlan, H. O'Shea, Mark R. Towler, S. Kehoe, D. Boyd
Chemical and Biochemical Engineering Faculty Research & Creative Works
Poly (lactide-co-glycolide) (PLGA) - Pluronic F127 - glass composites have demonstrated excellent potential, from the perspective of controlled mechanical properties and cytocompatibility, for peripheral nerve regeneration. In addition to controlling the mechanical properties and cytotoxicity for such composite devices, the glass component may mediate specific responses upon implantation via degradation in the physiological environment and release of constituent elements. However, research focused on quantifying the release levels of such therapeutic ions from these experimental medical devices has been limited. To redress the balance, this paper explores the ion release profiles for Si4+, Ca2+, Na+, …
Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence On Scan Direction And Velocity, Tiantian Xu
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Cardiovascular disease is the leading cause death in the United States. Although emergency surgery and medicine can be used for cardiovascular disease treatment, the survivors will suffer for it afterwards. Ultrasound blood flow measurement provides a noninvasive way for cardiovascular diseases diagnosis. In this dissertation, three algorithms for blood flow velocity measurements were investigated and optimized. Feature tracking has been previously proposed for vector velocity measurement. In Chapter 3, the optimal amplitude and time thresholds for feature extraction were investigated to minimize flow estimate variance while providing sufficient spatial and temporal coverage of flow area. A new method of lateral …
Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi
Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Laparo-Endoscopic Single Site (LESS) Robotics Surgery is an advanced technology in the field of Minimally Invasive Surgery (MIS). The LESS surgical robots significantly improve the surgeon’s accuracy, dexterity and visualization, and reduce the invasiveness of surgical procedure results in faster recovery time and improved cosmetic results. In a standard robotic endosurgery, the palpation of tissues is performed by laparoscopic graspers located at the end effectors. The master-slave configuration in robotic surgery leads in remote access to the operation site. Therefore, surgeon’s ability to perceive valuable sensory information is severely diminished. Sensory information such as haptics, which is essential for safe …
Development And Characterization Of An In-House Custom Bioreactor For The Cultivation Of A Tissue Engineered Blood-Brain Barrier, Amin Hadi Mirzaaghaeian
Development And Characterization Of An In-House Custom Bioreactor For The Cultivation Of A Tissue Engineered Blood-Brain Barrier, Amin Hadi Mirzaaghaeian
Master's Theses
The development of treatments for neurological disorders such as Alzheimer’s and Parkinson’s disease begins by understanding what these diseases affect and the consequences of further manifestation. One particular region where these diseases can produce substantial problems is the blood-brain barrier (BBB). The BBB is the selective diffusion barrier between the circulating blood and the brain. The barrier’s main function is to maintain CNS homeostasis and protect the brain from the extracellular environment. The progression of BBB research has advanced to the point where many have modeled the BBB in vitro with aims of further characterizing and testing the barrier. Particularly, …
The Structural Characterization Of Ga 2o 3-Na 2o-Cao-Zno-Sio 2 Bioactive Glasses, T. J. Keenan, A. W. Wren, A. Coughlan, M. M. Hall, Mark R. Towler
The Structural Characterization Of Ga 2o 3-Na 2o-Cao-Zno-Sio 2 Bioactive Glasses, T. J. Keenan, A. W. Wren, A. Coughlan, M. M. Hall, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
The characterization of bioactive glasses in which zinc (Zn) has been incrementally replaced by gallium (Ga). © 2012 IEEE.
Increasing The Quantity Of Silver In Zinc-Based Glass Polyalkenoate Cement: Is There An Improvement In Antibacterial Efficacy?, A. Coughlan, S. M. Breed, C. Ashraf, J. A. Cardinale, M. M. Hall, Mark R. Towler
Increasing The Quantity Of Silver In Zinc-Based Glass Polyalkenoate Cement: Is There An Improvement In Antibacterial Efficacy?, A. Coughlan, S. M. Breed, C. Ashraf, J. A. Cardinale, M. M. Hall, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Bone cements should have the ability to chemically bond to both bone and surgical metals, exhibit no chemical or thermal necrosis, and have no significant shrinkage or exotherm upon setting. Taking these properties into consideration, glass polyalkenoate cements (GPCs) have potential as bone cements. GPCs are formed by the reaction between an ion-leachable glass and an aqueous solution of polyacrylic acid (PAA) [1] and have proven antibacterial and cariostatic properties [2], which are related to their ability to release beneficial amounts of ions over time [3, 4]. The GPCs can be formulated to release ions that can have a therapeutic …
Silver Coated Bioactive Glass Particles For Wound Healing Applications, P. Hassanzadeh, A. W. Wren, Mark R. Towler
Silver Coated Bioactive Glass Particles For Wound Healing Applications, P. Hassanzadeh, A. W. Wren, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Hench and colleagues discovered that bone could bond chemically to certain glass compositions in 1969 [1]. This group of glasses is known as bioactive glasses [1]. Some special compositions of bioactive glasses will bond to soft tissues as well as bone [1]. One of the important characteristics of bioactive glasses is their ability to release beneficial ions such as Ca2+, Na+, Zn2+, Sr2+, and PO 43- in the body, which promote self-healing [2]. Bioactive glasses generally contain much less glass former (e.g., SiO2, B2O3 etc.) than conventional …
Gallium Containing Glass Polyalkenoate Bone Cements: Glass Characterization And Physical Properties, L. Placek, A. W. Wren, A. Coughlan, Mark R. Towler
Gallium Containing Glass Polyalkenoate Bone Cements: Glass Characterization And Physical Properties, L. Placek, A. W. Wren, A. Coughlan, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Gallium (Ga) glasses were developed to formulate a Glass Polyalkenoate Cement (GPC) series with both E9 and E11 polyacrylic acid (PAA) at 50, 55 and 60wt% additions. Working times (T w), setting times (T s), compression (σ c), and biaxial flexural (σ f) strength testing were evaluated to determine the GPCs potential use in orthopedics. © 2012 IEEE.
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …
Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser
Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser
Mechanical Engineering
Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …
A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen
A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen
Master's Theses
A new detection reagent that could possibly augment or replace antibodies research and diagnosis methods are aptamers. Aptamers are ssDNA, RNA or polypeptide constructs that function like active antibodies. Antibodies and aptamers both specifically bind to selected target molecules, and as such they enable the detection or targeting of the presence or absence of a specific antigen.
In order to ensure that ssDNA aptamers perform similarly to antibodies, anti-VEGF-A polyclonal antibody and anti-VEGF-A ssDNA aptamer were evaluated against vascular endothelial growth factor A (VEGF-A) using Surface Plasmon Resonance (SPR). It was hypothesized that the anti-VEGF-A aptamer had the same, if …