Open Access. Powered by Scholars. Published by Universities.®

Discipline
Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 751 - 780 of 1146

Full-Text Articles in Biomedical Devices and Instrumentation

Pathway By Which Vagus Nerve Stimulation Of B Fibers Affects Heart Rate, Kelsey Wasilczuk, Matthew Ward, Pedro Irazoqui Aug 2016

Pathway By Which Vagus Nerve Stimulation Of B Fibers Affects Heart Rate, Kelsey Wasilczuk, Matthew Ward, Pedro Irazoqui

The Summer Undergraduate Research Fellowship (SURF) Symposium

Heart failure (HF) affects over 5 million adults in the United States. Many HF patients have a high resting heart rate, which is correlated with a high mortality rate. In recent years, vagus nerve stimulation (VNS) has become an increasingly researched therapy to reduce the resting heart rate of HF patients. However, current dosage given during VNS is increased incrementally at the doctor’s office until side effects present themselves in a patient. In addition, the means by which the therapy works is not completely understood. To better understand the therapy’s mechanisms, the right cervical vagus nerve of several Long Evans …


Characterization Of Left-Ventricular Thrombus Formation Using High Frequency Ultrasound, Kelsey A. Bullens, Arvin H. Soepriatna, Pavlos P. Vlachos, Craig J. Goergen Aug 2016

Characterization Of Left-Ventricular Thrombus Formation Using High Frequency Ultrasound, Kelsey A. Bullens, Arvin H. Soepriatna, Pavlos P. Vlachos, Craig J. Goergen

The Summer Undergraduate Research Fellowship (SURF) Symposium

Heart failure is a leading cause of death in the United States, and cardiac thrombus, a common morbidity associated with heart failure, significantly increases a patient’s risk of embolic events. The objective of this project is to characterize left-ventricular (LV) thrombus development using high frequency ultrasound imaging in a murine model. C57BL/6J wild-type mice (n=6) were injected intraperitoneally with iron dextran five times a week for six weeks to increase oxidative stress in the heart. Granulocyte-colony stimulating factor (G-CSF) was subcutaneously injected daily during the second week to initiate stem cell migration and stimulate endothelial cell activation, thus increasing the …


Activity Of Protein Kinase A Attached To Magnetic Beads, Kevin P. Lin, Tamara L. Kinzer-Ursem, Mrugesh K. Parasa Aug 2016

Activity Of Protein Kinase A Attached To Magnetic Beads, Kevin P. Lin, Tamara L. Kinzer-Ursem, Mrugesh K. Parasa

The Summer Undergraduate Research Fellowship (SURF) Symposium

Development of high throughput assays is a crucial step in developing more efficient techniques that aid in many important areas of research today such as drug development or identification of protein structure function relationships. Integration of high throughput assays into more research efforts could drastically decrease the time and cost it takes for a new drug to hit the market. Protein Kinase A (PKA) is an extensively studied protein as it is highly upregulated in cancer and is a hot spot for drug targeting. In this work, azide-tagged PKA is covalently attached to magnetic beads using azide-alkyne cycloaddition, a well-known …


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Stimuli Responsive Fluidics Controls On A Paper-Based Bacterial Detection Platform, Siyu Zhao, Elizabeth Phillips, Jacqueline Linnes Aug 2016

Stimuli Responsive Fluidics Controls On A Paper-Based Bacterial Detection Platform, Siyu Zhao, Elizabeth Phillips, Jacqueline Linnes

The Summer Undergraduate Research Fellowship (SURF) Symposium

Infectious diseases are the leading causes of death around the world. Point-of-care devices using nucleic acid amplification are sensitive enough to diagnose these diseases, however, often require complex and time-intensive sample preparation steps that are not integrated with the detection process. A rapid, sensitive, and integrated sample-to-result diagnostic device will permit disease treatment planning at the point-of-care. Paper-based detection assays are a promising platform to integrate the sample preparation and detection, with minimal infrastructure, equipment, and user involvement. To integrate sample preparation with detection on paper-based assays, timing and delivery of sample fluid flow needs to be controlled. Here we …


Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer Aug 2016

Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer

Master's Theses

Transcatheter aortic heart valve replacement (TAVR) is a procedure to replace a failing aortic valve and is becoming the new standard of care for patients that are not candidates for open-heart surgery [2]. However, this minimally invasive technique has shown to cause ischemic brain lesions, or “silent infarcts”, in 90% of TAVR patients, which can increase the patient’s risk for stroke by two to four times in future years [3]. Claret Medical Inc., a medical device company, has developed a cerebral protection system that filters and captures embolic debris released during endovascular procedures, such as TAVR. This thesis utilized CT …


Hydrothermal Synthesis And Characterisation Of Bioactive Glass-Ceramic Nanorods, Ehsan Zeimaran, Sara Pourshahrestani, Seyed Farid Seyed Shirazi, Belinda Pingguan-Murphy, Nahrizul Adib Kadri, Mark R. Towler Jul 2016

Hydrothermal Synthesis And Characterisation Of Bioactive Glass-Ceramic Nanorods, Ehsan Zeimaran, Sara Pourshahrestani, Seyed Farid Seyed Shirazi, Belinda Pingguan-Murphy, Nahrizul Adib Kadri, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

In this study fabrication of rod-like bioactive glass-ceramics (BGCs) using hydrothermal treatment based on a sol-gel precursor is reported for the first time. BGCs with composition 58 wt% SiO2, 33 wt% CaO and 9 wt% P2O5 were synthesized in different thermal conditions (200 and 220 °C) and characterised with regard to morphology, chemical composition and crystallinity. The bioactivity of the materials was assessed by immersion in simulated body fluid for up to 7 days. The results revealed that as the reaction temperature increased from 200 to 220 °C, the diameter of rods was reduced from …


Functional Comparison Of Conventional Afos With The Dynamic Response Afo, Mitchell Ruble Jul 2016

Functional Comparison Of Conventional Afos With The Dynamic Response Afo, Mitchell Ruble

Master's Theses (2009 -)

Ankle foot orthoses (AFOs) are commonly prescribed to provide stability and foot clearance for patients with weakened or injured musculature. The Dynamic Response AFO (DRAFO) was designed to improve proprioception at heel strike. The design includes a rigid outer shell with a cut out heel and a soft inner lining; it is typically aligned in plantarflexion and may incorporate external heel wedges. The objective of this study was to investigate the effects of the DRAFO design features and contrast its biomechanical function with that of conventional locked and articulating AFOs. The research hypotheses were: 1) DRAFO-assisted gait parameters (e.g. ankle …


Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor Jun 2016

Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor

Mechanical Engineering

More than 300,000 total hip replacement surgeries are performed in the US each year. Minimally invasive total hip replacement surgery requires modified tools to access the smaller incision. An offset hip impactor was redesigned to improve tool lifetime, ease of use, and manufacturing cost. The redesigned tool had an increased lifetime and a significant reduction in the number of parts. The report contains detail drawings, a manufacturing plan, and physical testing results.


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang Jun 2016

Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang

Mechanical Engineering

Confidential


Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo Jun 2016

Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo

Biomedical Engineering

The World Health Organization estimates that over 30 million people require some sort of prosthetic technology. However, traditional prosthetic fitting practices take a lot of time and cost a lot of money, making them inaccessible to millions of people around the world. StandUP Worldwide is an interdisciplinary project team devoted to creating low-cost prosthetic technologies for use around the world, especially in resource poor areas. They are currently developing a low cost, below-the-knee prosthetic kit that can be easily deployed in a resource-poor area. The following presents their solution for a below-the-knee prosthetic socket, foot, and leg.


Raman Spectroscopic Analysis Of Fingernail Clippings Can Help Differentiate Between Postmenopausal Women Who Have And Have Not Suffered A Fracture, James R. Beattie, Niamh M. Cummins, Clare Caraher, Olive M. O'Driscoll, Aruna T. Bansal, Richard Eastell, Stuart H. Ralston, Michael D. Stone, Gill Pearson, Mark R. Towler May 2016

Raman Spectroscopic Analysis Of Fingernail Clippings Can Help Differentiate Between Postmenopausal Women Who Have And Have Not Suffered A Fracture, James R. Beattie, Niamh M. Cummins, Clare Caraher, Olive M. O'Driscoll, Aruna T. Bansal, Richard Eastell, Stuart H. Ralston, Michael D. Stone, Gill Pearson, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Raman spectroscopy was applied to nail clippings from 633 postmenopausal British and Irish women, from six clinical sites, of whom 42% had experienced a fragility fracture. The objective was to build a prediction algorithm for fracture using data from four sites (known as the calibration set) and test its performance using data from the other two sites (known as the validation set). Results from the validation set showed that a novel algorithm, combining spectroscopy data with clinical data, provided area under the curve (AUC) of 74% compared to an AUC of 60% from a reduced QFracture score (a clinically accepted …


Localized Immunotherapy Delivery Using Injectable In Situ Forming Chitosan Hydrogel, Seth Washispack May 2016

Localized Immunotherapy Delivery Using Injectable In Situ Forming Chitosan Hydrogel, Seth Washispack

Biomedical Engineering Undergraduate Honors Theses

Cytokine-based cancer immunotherapies stimulate a host’s immune system to fight cancer. In particular, interleukin-12 (IL-12), a potent pro-inflammatory cytokine, has demonstrated the ability to eliminate tumors in a number of preclinical models. Toxicities associated with the systemic delivery of IL-12 have precluded its use in the clinic. We are developing a novel chitosan-based hydrogel to maintain high local concentrations of cytokines, such as IL-12, in the tumor while minimizing its systemic dissemination. This hydrogel was found to form spontaneously within ten seconds of mixing two proprietary components. To increase the usefulness of the hydrogel, an efficient mixing and delivery system …


Intravital Microscopy Of Tumor Oxygenation And Glycolytic Demand, Jesse D. Ivers May 2016

Intravital Microscopy Of Tumor Oxygenation And Glycolytic Demand, Jesse D. Ivers

Biomedical Engineering Undergraduate Honors Theses

There is growing concern about the over treatment of cancer because treatments are based primarily on tumor anatomy. In this study, we aim to begin the process of addressing that issue by developing an intravital technique for optically analyzing tumor biology. Two traits were identified as having significant importance in the aggression of a tumor, vascular oxygenation (SO2) and glycolytic demand. Dorsal skin flap window chambers were implanted and 4T1 and 67NR cancer cells were injected to provide a tumor model for the development of this intravital quantification technique. This study provides a detailed protocol from instrumentation setup to surgical …


Design Of A 3d-Printed Device For Diffuse Reflectance Spectroscopy Calibration As A Step Towards Clinical Translation, Nontapoth Vongkittiargorn May 2016

Design Of A 3d-Printed Device For Diffuse Reflectance Spectroscopy Calibration As A Step Towards Clinical Translation, Nontapoth Vongkittiargorn

Biomedical Engineering Undergraduate Honors Theses

The diffusive reflectance and spectroscopic microendoscopy (DRSME) is a multimodal imaging system that harnesses its usefulness from different light sources. One of the modalities, diffuse reflectance spectroscopy (DRS), has been used in our lab to investigate optical properties of epithelial tissues using a broadband white light as the main source. Calibration of DRS is required as it can obtain the maximum intensity and convert it to absolute reflectance. Current manual-adjusted calibration can be lengthy and often lead to inconsistent results. Therefore, a new method of calibration is introduced where additive manufacturing (or 3D printing) technology is fully utilized.

The instrumentation …


Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson May 2016

Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson

Graduate Theses and Dissertations

There exists a need for research of optical methods capable of image cytometry suitable for point-of-care technology. To propose am optical approach with no moving parts for simplification of mechanical components for the further development of the technology to the poin-of-care, a linear sensor with push broom translation method. Push broom translation is a method of moving objects by the sensor for an extended field of view. A polydimethylsiloxane (PDMS) microfluidic chamber with a syringe pump was used to deliver objects by the sensor. The volumetric rate of the pump was correlated to the integration time of the sensor to …


Design Of Exercise Equipment For Wheelchair Users: A Case Study In Accessibility Standards, Kate Craddock Rescsanszky May 2016

Design Of Exercise Equipment For Wheelchair Users: A Case Study In Accessibility Standards, Kate Craddock Rescsanszky

Honors Scholar Theses

Engineers must consider a number of aspects of every project they work on. Accessibility is one aspect that presents a unique challenge. Rather than being based on absolute material parameters, accessibility is based on how people interact with technology and their built environment. Since 1990, the Americans with Disabilities Act has been the predominant standard in accessibility because of its wide reach and legal mandate. In addition to the ADA, the ASTM and the Institute for Universal Design offer helpful guidelines for designing for accessibility. However, in addition to standards, guidelines, and recommendations, it is important to consult the intended …


Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li May 2016

Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li

UNLV Theses, Dissertations, Professional Papers, and Capstones

An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …


Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum May 2016

Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Acute respiratory distress syndrome (ARDS) is a pulmonary disease that causes hypoxemia and respiratory failure. The mortality rate for ARDS ranges between 27% and 45%. Current treatments including mechanical ventilation and extracorporeal membrane oxygenation (ECMO) are often associated with high risk complications including barotrauma, infection, thrombosis, and hemorrhage. Alternative pulmonary support techniques are needed to improve the survival rate of patients suffering from ARDS. Previous studies introducing pure O2 gas, perfluorocarbons and red blood cells into the intraperitoneal (IP) cavity have reported no effect or only a mild increase in oxygenation. Here we report peritoneal membrane oxygenation (PMO) using …


Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch Apr 2016

Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

This thesis presents the design, controls, and testing of two systems: a novel colonoscope locomotion design for diagnostics, and a biosensor capsule that implants a sensor in the small intestine. Each system requires special design considerations for use in the gastrointestinal system.

Colonoscopy procedures are recommended as a screening for colon cancer and related conditions after the age of 50. The need for an improved colonoscope that reduces the colonoscopy time and patient discomfort is apparent. The semi-autonomous device presented here could likely reduce the colonoscopy procedure time by allowing the physician to focus more on the diagnosis and less …


Under The Needle: Ergonomic Issues With Lethal Injection Protocols, Gabriella Hancock Apr 2016

Under The Needle: Ergonomic Issues With Lethal Injection Protocols, Gabriella Hancock

Human Factors and Applied Psychology Student Conference

The institution of capital punishment represents one of the most contentious issues affecting societies today; and while the practice is only implemented in 58 countries, the controversy affects the world at large as over 60% of the human population lives in nations that condone the death penalty (Hali, 2015). In the United States, people who support capital punishment believe the practice to be an effective crime deterrent for potential criminals and therefore a prospective protective measure for law abiding citizens. Moreover, advocates defend their position by forwarding the argument that executions are ‘humane’; that use of lethal injection ensures that …


Circle Of Willis Model For Transcranial Doppler Ultrasound Training, Conner J. Beyersdorf, Ben Hage, Greg Bashford Apr 2016

Circle Of Willis Model For Transcranial Doppler Ultrasound Training, Conner J. Beyersdorf, Ben Hage, Greg Bashford

UCARE: Research Products

Transcranial Doppler (TCD) ultrasound is a technique involving the use of high frequency transmitters to measure intracranial blood flow. The brain is supplied by blood in an arterial anastomosis called the Circle of Willis. Using TCD ultrasound on the circle is difficult and requires practice and teaching. A functional model of the Circle of Willis could prove to be a valuable teaching tool. Through the use of AutoCAD and 3D printing software, an anatomically accurate model was created and set in gelatin phantom inside of a plastic skull. Milk was pumped through the model with a peristaltic pump to simulate …


The Role Of Poly(Acrylic Acid) In Conventional Glass Polyalkenoate Cements, Adel M.F. Alhalawani, Declan J. Curran, Daniel Boyd, Mark R. Towler Apr 2016

The Role Of Poly(Acrylic Acid) In Conventional Glass Polyalkenoate Cements, Adel M.F. Alhalawani, Declan J. Curran, Daniel Boyd, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Glass polyalkenoate cements (GPCs) have been used in dentistry for over 40 years. These novel bioactive materials are the result of a reaction between a finely ground glass (base) and a polymer (acid), usually poly (acrylic acid) (PAA), in the presence of water. This article reviews the types of PAA used as reagents (including how they vary by molar mass, molecular weight, concentration, polydispersity and content) and the way that they control the properties of the conventional GPCs (CGPCs) formulated from them. The article also considers the effect of PAA on the clinical performance of CGPCs, including biocompatibility, rheological and …


Structural-Functional Brain Connectivity Underlying Integrative Sensorimotor Function After Stroke, Benjamin Thomas Kalinosky Apr 2016

Structural-Functional Brain Connectivity Underlying Integrative Sensorimotor Function After Stroke, Benjamin Thomas Kalinosky

Dissertations (1934 -)

In this dissertation research project, we demonstrated the relationship between the structural and functional connections across the brain in stroke survivors. We used this information to predict arm function in stroke survivors, suggesting that the tools developed through this research will be useful for prescribing individualized rehabilitation strategies in people after stroke. Current clinical methods for rehabilitating sensorimotor function after stroke are not based on the locus of injury in the brain. Instead, therapies are generalized, treating symptoms such as weakness and spasticity. This results in outcomes that are highly variable, with severity of impairment immediately following stroke as the …


Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley Mar 2016

Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley

Master's Theses

Despite significant preventative efforts, falls continue to be a major source of morbidity and mortality among the elderly. Additionally, the fear of falling can be a major obstacle to independent living for otherwise self-sufficient individuals. This fear is significantly heightened in individuals who have sustained a fall and often results in self-imposed restrictions on mobility and exercise, causing weakening in these individuals and further exacerbating the danger. Much time has been spent developing alert systems in an attempt to mitigate these problems. Unfortunately these systems typically involve dedicated monitoring centers and therefore often come with substantial upfront and recurring costs. …


Design And Analysis Of A Lift Assist Walker, Deep P. Shah Mar 2016

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


Characterization Of Silica-Based And Borate-Based, Titanium-Containing Bioactive Glasses For Coating Metallic Implants, Omar Rodriguez, Declan J. Curran, Marcello Papini, Lana M. Placek, Anthony W. Wren, Emil H. Schemitsch, Paul Zalzal, Mark R. Towler Feb 2016

Characterization Of Silica-Based And Borate-Based, Titanium-Containing Bioactive Glasses For Coating Metallic Implants, Omar Rodriguez, Declan J. Curran, Marcello Papini, Lana M. Placek, Anthony W. Wren, Emil H. Schemitsch, Paul Zalzal, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Bioactive glasses have found applications in diverse fields, including orthopedics and dentistry, where they have been utilized for the fixation of bone and teeth and as scaffolds for drug delivery. The present work outlines the characterization of two novel titanium-containing glass series, one silica-based and one borate-based. For the silica-based series, titanium is added at the expense of silicon dioxide whereas for the borate-based series, it is added at the expense of boron oxide as confirmed by Energy Dispersive Spectroscopy. Amorphous structures are obtained for silica-based glass at 15 mol% TiO2 and for borate-based glasses at 0 mol% and …


Effect Of Temporal Onset Of Mechanical Loading On Tendon To Bone Healing, Determined With A Novel In-Vivo Device, Mark E. Stasiak Feb 2016

Effect Of Temporal Onset Of Mechanical Loading On Tendon To Bone Healing, Determined With A Novel In-Vivo Device, Mark E. Stasiak

Dissertations, Theses, and Capstone Projects

Background: Exposure to tensile loading has been shown to maintain tendon/ligament homeostasis, with the tensile modulus of the tissue increasing in response to greater loading frequency, and even decreasing in the absence of load. However after injury or surgical repair the effect of tensile load is controversial, with many studies implicating mechanical loading with impaired healing. It is currently unknown when the tensile loading imparted during rehabilitation exercise, can be safely reintroduced after surgical tendon repair or ligament reconstruction, and at what time point it can most benefit the remodeling process. To investigate the effect of tensile loading protocols on …


Expanded 3d Nanofiber Scaffolds: Cell Penetration, Neovascularization, And Host Response, Jiang Jiang, Zhuoran Li, Hongjun Wang, Yue Wang, Mark A. Carlson, Matthew J. Teusink, Matthew R. Macewan, Linxia Gu, Jingwei Xie Jan 2016

Expanded 3d Nanofiber Scaffolds: Cell Penetration, Neovascularization, And Host Response, Jiang Jiang, Zhuoran Li, Hongjun Wang, Yue Wang, Mark A. Carlson, Matthew J. Teusink, Matthew R. Macewan, Linxia Gu, Jingwei Xie

Department of Mechanical and Materials Engineering: Faculty Publications

Herein, a robust method to fabricate expanded nanofiber scaffolds with controlled size and thickness using a customized mold during the modified gas-foaming process is reported. The expansion of nanofiber membranes is also simulated using a computational fluid model. Expanded nanofiber scaffolds implanted subcutaneously in rats show cellular infiltration, whereas non-expanded scaffolds only have surface cellular attachment. Compared to unexpanded nanofiber scaffolds, more CD68+ and CD163+ cells are observed within expanded scaffolds at all tested time points post-implantation. More CCR7+ cells appear within expanded scaffolds at week 8 post-implantation. In addition, new blood vessels are present within the expanded scaffolds at …