Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (236)
- Electrical and Computer Engineering (177)
- Chemical Engineering (170)
- Mechanical Engineering (170)
- Biochemical and Biomolecular Engineering (147)
-
- Biomedical (121)
- Bioimaging and Biomedical Optics (101)
- Biomechanical Engineering (101)
- Other Biomedical Engineering and Bioengineering (101)
- Biomaterials (91)
- Biomechanics and Biotransport (91)
- Life Sciences (89)
- Bioelectrical and Neuroengineering (77)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (71)
- Molecular, Cellular, and Tissue Engineering (63)
- Physical Sciences and Mathematics (63)
- Medical Specialties (60)
- Biological Engineering (51)
- Electrical and Electronics (51)
- Materials Science and Engineering (50)
- Systems and Integrative Engineering (49)
- Computer Engineering (45)
- Signal Processing (39)
- Rehabilitation and Therapy (38)
- Medical Sciences (36)
- Diseases (34)
- Electro-Mechanical Systems (29)
- Institution
-
- California Polytechnic State University, San Luis Obispo (213)
- Missouri University of Science and Technology (131)
- University of Arkansas, Fayetteville (69)
- The University of Akron (48)
- University of Nebraska - Lincoln (45)
-
- Purdue University (39)
- University of Nevada, Las Vegas (32)
- Technological University Dublin (27)
- Marquette University (26)
- City University of New York (CUNY) (25)
- University of Kentucky (25)
- Dartmouth College (24)
- Old Dominion University (24)
- Virginia Commonwealth University (22)
- University of Louisville (21)
- Clemson University (19)
- University of Mississippi (19)
- University of Connecticut (17)
- Kettering University (16)
- Michigan Technological University (15)
- University of Denver (14)
- Brigham Young University (11)
- West Virginia University (11)
- Louisiana State University (10)
- Washington University in St. Louis (10)
- Duquesne University (9)
- Embry-Riddle Aeronautical University (9)
- University of Malaya (9)
- Cleveland State University (7)
- Georgia Southern University (7)
- Keyword
-
- Microfluidics (34)
- Biomechanics (14)
- Biomedical Engineering (14)
- Biomedical (13)
- Biomedical engineering (13)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (13)
- Machine learning (12)
- Prosthetic (12)
- Cancer (11)
- Device (11)
- Engineering (11)
- Machine Learning (11)
- Prosthetics (11)
- Medical device (10)
- Surgery (10)
- Biomaterials (9)
- Electrophysiology (9)
- Kinematics (9)
- 3D printing (8)
- Applied sciences (8)
- Biosensor (8)
- Diagnostics (8)
- Gait (8)
- Mechanical and Materials Engineering (8)
- Sensor (8)
- Ultrasound (8)
- Wearable (8)
- Arduino (7)
- Bone (7)
- Breast cancer (7)
- Publication Year
- Publication
-
- Chemical and Biochemical Engineering Faculty Research & Creative Works (131)
- Master's Theses (98)
- Biomedical Engineering (79)
- Williams Honors College, Honors Research Projects (47)
- Electronic Theses and Dissertations (42)
-
- Graduate Theses and Dissertations (32)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (30)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (28)
- Biomedical Engineering Undergraduate Honors Theses (25)
- Theses and Dissertations (25)
- Honors Theses (22)
- Mechanical Engineering (22)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (17)
- Master's Theses (2009 -) (17)
- Theses and Dissertations--Biomedical Engineering (17)
- Conference Papers (16)
- Dissertations, Master's Theses and Master's Reports (15)
- Dissertations and Theses (12)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (11)
- Mechanical Engineering Patents (11)
- All Dissertations (10)
- Biomedical Engineering Western Regional Conference (10)
- Dartmouth College Ph.D Dissertations (10)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (10)
- Publications and Research (10)
- All Theses (9)
- Dissertations (1934 -) (9)
- Student Works (2020-2029) (9)
- Honors Scholar Theses (8)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (7)
- Publication Type
- File Type
Articles 1021 - 1050 of 1146
Full-Text Articles in Biomedical Devices and Instrumentation
A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell
A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell
Master's Theses
This project encompasses the design and development of a pretreatment microfluidic device for samples of physiological conductivity, namely a saline solution. The conductivity was reduced through the combination of dilution and ion removal using electric fields to enable downstream electro kinetic manipulations. The two major parts of this project include (1) designing a pretreatment protocol to reduce the conductivity of the sample solution to an acceptable level and (2) designing /fabricating a microchip that will effectively allow aim (1) to be performed on chip.
This project is one of the first to observe the effects of an electric field, used …
Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett
Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett
Master's Theses
Development of an Open Source Prosthetic Hand Platform
Scott Garrett
In the field of upper extremity prosthetic devices, advancements in technology drive the design of products which are becoming capable of restoring the lost functions of the native hand. While several dexterous devices have been developed to serve this purpose, they remain prohibitively expensive and thus are not a viable option for many upper extremity amputees. To address this problem a prosthetic hand platform was developed utilizing the open source Arduino microcontroller and off-the-shelf electrical components. Using these resources, a novel finger actuation mechanism was developed to show how …
Control System For Mass Spectrometer, Jian Xu
Control System For Mass Spectrometer, Jian Xu
Purdue Polytechnic Masters Theses
Mass spectrometry (MS) is a very popular analytical methodology that measures the mass of ions using a mass spectrometer. It is widely used for determining masses of chemicals, the elemental composition of a sample and molecule structure. The process of mass spectrometry normally consists of ionizing chemical compounds to ions and measuring their ratios of mass to charge for analysis.
MS instruments consist of three modules: Ionization, Analysis and detection. A LabVIEW system was developed to control the three modules of a mass spectrometer, giving the required signals in a right sequence. Experiments can be carried out by using the …
Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri
Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri
Master's Theses
The development, progression, and treatment of degenerative musculoskeletal diseases, such as carpal tunnel and shoulder impingement syndromes, may be better characterized when joint motions are assessed over long durations outside clinical, laboratory, or rehabilitation settings that involve standardized assessment, exercise protocols, and/or regimented movements. Assessment methods for human movement capture beyond laboratory or clinical experiments are typically limited to short capture times of less than one hour. Noninvasive, long-duration measurements of joint motion in occupational settings provides more insight into movement patterns and quantitative assessments regarding joint usage, which lead to a better understanding of the cumulative effects associated with …
A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman
A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman
Master's Theses
Hemoglobin can be measured on a variety of devices using different principles of operation. Noninvasive pulse CO-oximetry represents the latest development in hemoglobin measuring technology. The technology uses principles similar to pulse oximetry to measure total hemoglobin, oxyhemoglobin, reduced oxyhemoglobin, carboxyhemoglobin and methemoglobin. Similar to the introduction of pulse oximetry to the medical field, pulse CO-oximetry has been met with skepticism. Since the technology is noninvasive and provides continuous monitoring in comparison to invasive and discrete techniques used in other methods, CO-oximetry purportedly provides an advantage in patient care. The purpose of this research is threefold: (a) to review the …
Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette
Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette
Master's Theses
In today’s healthcare environment, networking of medical devices is becoming more and more prevalent. There is an increasing need for mobile technology to meet clinical needs. Wireless communication is essential for allowing medical devices to be able to move with the patient, while continuing to record and communicate patient data. A traditional example is telemetry monitoring, but other examples of wireless utilization include sending ECG test results to the EMR or remotely updating the drug library on numerous IV pumps. Each wireless application has varying demands on the connectivity infrastructure and will share radio frequency (RF) spectrum resources with a …
Construction And Use Of A Direct Calorimeter To Estimate Energy Expenditure In Hibernators, Mark S. Burger, Frank Van Breukelen
Construction And Use Of A Direct Calorimeter To Estimate Energy Expenditure In Hibernators, Mark S. Burger, Frank Van Breukelen
Festival of Communities: UG Symposium (Posters)
Metabolic rates have traditionally been estimated through indirect calorimetry (gas exchange or respirometry) due to its ease and availability. Oxygen consumption neglects the contributions of anaerobic metabolism, while direct calorimetry (heat production) estimates both anaerobic and aerobic metabolism. Walsberg and Hoffman (2005) report anaerobic metabolism may be more important to small rodents than was previously thought. During the non-steady state of mammalian hibernation, we hypothesize that anaerobic processes may play an even greater role in fueling metabolism. To address this question, we constructed a very sensitive calorimeter that utilizes the Seebeck effect from a thermoelectric element (Peltier device). We describe …
Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler
Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Gas emboli are a clinical issue often encountered in the space exploration, marine construction, and medical fields. Individuals involved with these disciplines will often have asympomatic gas emboli circulating throughout their bodies on a regular basis. A study into the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis in humans is thus presented. This research utilized a custom built cardiovascular flow simulator and accompanying data acquisition system to experimentally determine the influence of gas emboli under varied circumstances on the mean wall shear stress of a tube in-vitro. A directly inverse relationship between gas embolus presence in …
Leaching Of Potential Hazardous Elements Of Coal Cleaning Rejects, Luis F.O. Silva, Maria Izquierdo, Xavier Querol, Robert B. Finkelman, Marcos L.S. Oliveira, Marcus Wollenschlager, Mark R. Towler, Rafael Pérez-López, Felipe Macias
Leaching Of Potential Hazardous Elements Of Coal Cleaning Rejects, Luis F.O. Silva, Maria Izquierdo, Xavier Querol, Robert B. Finkelman, Marcos L.S. Oliveira, Marcus Wollenschlager, Mark R. Towler, Rafael Pérez-López, Felipe Macias
Chemical and Biochemical Engineering Faculty Research & Creative Works
The geochemical characteristics of coal cleaning rejects (CCR) in Santa Catarina State, Brazil, were investigated. Around 3.5 million ton/ year of coal waste are dumped in Santa Catarina State. Coal beneficiation by froth flotation results in large amounts of CCR composed of coaly and mineral matter, the latter characterized by the occurrence of sulphide minerals and a broad array of leachable elements. The total and leachable contents of more than 60 elements were analyzed. Atmospheric exposure promotes sulphide oxidation that releases substantial sulphate loads as well as Ca2+, K+, Mg2+, Cl- and Al3+ …
Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do
Master's Theses
During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process. In addition, some applications of UEP are incorporated into the official releases of the device product. UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD). This thesis covers the flexible and reusable …
The Structural Role Of Titanium In Ca-Sr-Zn-Si/Ti Glasses For Medical Applications, A. W. Wren, F. R. Laffir, A. Kidari, Mark R. Towler
The Structural Role Of Titanium In Ca-Sr-Zn-Si/Ti Glasses For Medical Applications, A. W. Wren, F. R. Laffir, A. Kidari, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glasses for medical applications are used in particulate form or as a cement component. This work was undertaken to determine structural changes in 0.48SiO2-0.36ZnO-0.12CaO-0.04SrO glass when the SiO2 is substituted with 5 mol% increments of TiO2. X-ray Diffraction (XRD) was used to determine the presence of crystallinity. This occurred after additions of 20 mol% TiO2. Differential Thermal Analysis (DTA) and Network connectivity (NC) calculations determined that by increasing the TiO2 content, the Tg and NC reduced (Tg 670 °C to 632 °C, NC 1.83 to -1.14) suggesting that TiO2 acts as …
Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre
Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre
Master's Theses
This thesis encompasses a feasibility study of using low-cost materials to manufacture microfluidic chips that can perform the same functions as chips manufactured using traditional methods within an acceptable range of efficiency of chips created with more exotic methods and materials. The major parts of the project are the selection and characterization of the fabrication methods for creating the channels for fluid flow, the methods for sealing the channels to create a usable chip and the electrophoretic separations of carboxylated microspheres of different potentials. In this work we seek to answer the question if laser-etched PMMA microfluidic chips are comparable …
Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel
Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel
Master's Theses
As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.
Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle
Conference Papers
In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …
High Power, Low Frequency Ultrasound: Meniscal Tissue Interaction And Ablation Characteristics, Brendan O'Daly, Edmund Morris, Graham Gavin, Conor Keane, John O Byrne, Garrett Mcguinness
High Power, Low Frequency Ultrasound: Meniscal Tissue Interaction And Ablation Characteristics, Brendan O'Daly, Edmund Morris, Graham Gavin, Conor Keane, John O Byrne, Garrett Mcguinness
Articles
Abstract—This study evaluates high power low frequency ultrasound transmitted via a flat vibrating probe tip as an alternative technology for meniscal debridement in the bovine knee. An experimental force controlled testing rig was constructed using a 20 kHz ultrasonic probe suspended vertically from a load cell. Effect of variation in amplitude of distal tip displacement (242–494 mm peak-peak) settings and force (2.5–4.5 N) on tissue removal rate (TRR) and penetration rate (PR) for 52 bovine meniscus samples was analyzed. Temperature elevation in residual meniscus was measured by embedded thermocouples and histologic analysis. As amplitude or force increases, there is a …
Design, Fabrication, And Testing Of An Electrospinning Apparatus For The Deposition Of Pmma Polymer For Biomedical Applications, Harsha Malshe
Design, Fabrication, And Testing Of An Electrospinning Apparatus For The Deposition Of Pmma Polymer For Biomedical Applications, Harsha Malshe
Inquiry: The University of Arkansas Undergraduate Research Journal
This paper describes the successful design and fabrication of a deposition system for synthesis and assembly of nanoscale and submicron sized fibers of poly(methylmethacrylate)(PMMA) polymer. To optimize the electrospinning deposition process, the distance between the needle and the electrically grounded substrate, the applied voltage, and the concentration of PMMA polymer in the solution were varied. PMMA fibers as small as 500 nanometers were observed using scanning electron microscopy (SEM). The chemical signature of PMMA was confirmed for best quality and retention of chemistry using Fourier Transformed Infrared spectroscopy (FT-IR). PMMA is a biocompatible polymer, and nanofibers of PMMA are key …
The Bioactivity And Ion Release Of Titanium-Containing Glass Polyalkenoate Cements For Medical Applications, A. W. Wren, N. M. Cummins, F. R. Laffir, S. P. Hudson, Mark R. Towler
The Bioactivity And Ion Release Of Titanium-Containing Glass Polyalkenoate Cements For Medical Applications, A. W. Wren, N. M. Cummins, F. R. Laffir, S. P. Hudson, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
The ion release profiles and bioactivity of a series of Ti containing glass polyalkenoate cements. Characterization revealed each material to be amorphous with a Tg in the region of 650-660°C. The network connectivity decreased (1.83-1.35) with the addition of TiO2 which was also evident with analysis by X-ray photoelectron spectroscopy. Ion release from cements were determined using atomic absorption spectroscopy for zinc (Zn2+), calcium (Ca2+), strontium (Sr2+), Silica (Si4+) and titanium (Ti4+). Ions such as Zn2+ (0.1-2.0 mg/l), Ca2+ (2.0-8.3 mg/l,) Sr2+ (0.1-3.9 mg/l), and Si4+ …
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle
Conference Papers
Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …
Arterial Tissue Perforation Using Ultrasonically Vibrating Wire Waveguides, Mark Wylie
Arterial Tissue Perforation Using Ultrasonically Vibrating Wire Waveguides, Mark Wylie
Doctoral
Chronic Total Occlusions (CTOs) are fibrous and calcified atherosclerotic lesions which completely occlude the artery. They are difficult to treat with standard dilation procedures as they cannot be traversed easily. Their treatment is also associated with a high risk of arterial perforation. Low frequency ultrasonic vibrations delivered via wire waveguides represent a minimally invasive treatment for CTOs and other tissue ablation applications. These devices typically operate at 20–50 kHz delivering wire waveguide distal tip amplitudes of vibration of 0-60 μm. The diseased tissue is ablated or disrupted by repetitive direct mechanical contact and cavitation. This research assesses the susceptibility of …
The Response Of Pseudomonas Aeruginosa Biofilm To The Presence Of A Glass Polyalkenoate Cement Formulated From A Silver Containing Glass, A. Coughlan, M. P. Ryan, N. M. Cummins, Mark R. Towler
The Response Of Pseudomonas Aeruginosa Biofilm To The Presence Of A Glass Polyalkenoate Cement Formulated From A Silver Containing Glass, A. Coughlan, M. P. Ryan, N. M. Cummins, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
No abstract provided.
In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen
In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen
Articles
A compact patch applicator designed to enhance targeted energy coupling at 434 MHz is a key enabler for sensitizing temperature increments in body regions containing superficial tumours. A detailed FDTD body model is used to explore simulated RF coupling and temperature increments for typical clinical conditions. The antenna impedance matching, specific absorption rate and thermal distribution parameters are evaluated to identify applied performance outcomes. The analysis reveals physiological-RF coupling patterns for an optimised closely-coupled single element applicator.
Singular Value Decomposition Metrics Show Limitations Of Detector Design In Diffuse Fluorescence Tomography, Frederic Leblond, Kenneth M. Tichauer, Brian W. Pogue
Singular Value Decomposition Metrics Show Limitations Of Detector Design In Diffuse Fluorescence Tomography, Frederic Leblond, Kenneth M. Tichauer, Brian W. Pogue
Dartmouth Scholarship
The spatial resolution and recovered contrast of images reconstructed from diffuse fluorescence tomography data are limited by the high scattering properties of light propagation in biological tissue. As a result, the image reconstruction process can be exceedingly vulnerable to inaccurate prior knowledge of tissue optical properties and stochastic noise. In light of these limitations, the optimal source-detector geometry for a fluorescence tomography system is non-trivial, requiring analytical methods to guide design. Analysis of the singular value decomposition of the matrix to be inverted for image reconstruction is one potential approach, providing key quantitative metrics, such as singular image mode spatial …
Comparison Of Antibacterial Properties Of Commercial Bone Cements And Fillers With A Zinc-Based Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, Mark R. Towler
Comparison Of Antibacterial Properties Of Commercial Bone Cements And Fillers With A Zinc-Based Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Postoperative infection following invasive surgical procedures is a significant cause for concern, particularly in spinal reconstructive surgery. The objective of this study is to compare the antibacterial efficacy of a novel zinc-based glass polyalkenoate cement (Zn-GPC) based on 0.04SrO-0.12CaO-0.36ZnO- 0.48SiO2 glass, to a number of commercially available bone cements and fillers including Simplex P + Tobramycin (STob), Spineplex (Spine) and Novabone Putty (NPut). The agar diffusion test was performed on each material against Escherichia coli, Staphlococcus epidermidis, Pseudomonas aeruginosa and Staphlococcus Aureus. STob was found to produce large inhibition zones in each …
The Effect Of Ionic Dissolution Products Of Ca-Sr-Na-Zn-Si Bioactive Glass On In Vitro Cytocompatibility, S. Murphy, A. W. Wren, Mark R. Towler, D. Boyd
The Effect Of Ionic Dissolution Products Of Ca-Sr-Na-Zn-Si Bioactive Glass On In Vitro Cytocompatibility, S. Murphy, A. W. Wren, Mark R. Towler, D. Boyd
Chemical and Biochemical Engineering Faculty Research & Creative Works
Many commercial bone grafts cannot regenerate healthy bone in place of diseased bone. Bioactive glasses have received much attention in this regard due to the ability of their ionic dissolution products to promote cell proliferation, cell differentiation and activate gene expression. Through the incorporation of certain ions, bioactive glasses can become therapeutic for specific pathological situations. Calcium-strontium-sodium-zinc-silicate glass bone grafts have been shown to release therapeutic levels of zinc and strontium, however the in vitro compatibility of these materials is yet to be reported. In this study, the in vitro cytocompatibility of three different calcium-strontium-sodium-zinc-silicate glasses was examined as a …
Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo
Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo
Master's Theses
The application of high frequency ultrasound is the key to higher resolution intravascular ultrasound (IVUS) images. The need to further improve the IVUS spatial resolution may drive the transducer center frequency even higher than the current 40 MHz range. However, increasing the center frequency may be challenging as it leads to stronger scattering echoes from blood. The high level of blood scattering echoes may obscure the arterial lumen and make image interpretation difficult. Blood backscatter levels increase with transmission center frequency at a much greater rate compared to arterial tissue. These different frequency dependencies provide a potential method to distinguish …
A Spectroscopic Investigation Into The Setting And Mechanical Properties Of Titanium Containing Glass Polyalkenoate Cements, A. W. Wren, A. Kidari, N. M. Cummins, Mark R. Towler
A Spectroscopic Investigation Into The Setting And Mechanical Properties Of Titanium Containing Glass Polyalkenoate Cements, A. W. Wren, A. Kidari, N. M. Cummins, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Titanium (Ti) implants are extensively used in a number of biomedical and dental applications. This work introduces Ti into the glass phase of a zinc-based glass polyalkenoate cement (GPC) and investigates changes in handling and mechanical properties considering two molecular weight polyacrylic acids (PAA), E9 and E11. Considering the handling properties, the working time (Tw) increased from 50 sE9, 32 sE11 (BT 101, Ti-free) to 169 sE9, 74 sE11 with TW-Z (highest Ti content), respectively. The setting time (Ts) increased from 76 sE9, 47 sE11 (BT 101) …
Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel
Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel
Dissertations and Theses (Open Access)
Medical instrumentation used in diagnosis and treatment relies on the accurate detection and processing of various physiological events and signals. While signal detection technology has improved greatly in recent years, there remain inherent delays in signal detection/ processing. These delays may have significant negative clinical consequences during various pathophysiological events. Reducing or eliminating such delays would increase the ability to provide successful early intervention in certain disorders thereby increasing the efficacy of treatment.
In recent years, a physical phenomenon referred to as Negative Group Delay (NGD), demonstrated in simple electronic circuits, has been shown to temporally advance the detection of …
St. Jude Medical: An Object-Oriented Software Architecture For Embedded And Real-Time Medical Devices, Atila Amiri
St. Jude Medical: An Object-Oriented Software Architecture For Embedded And Real-Time Medical Devices, Atila Amiri
Master's Theses
Medical devices used for surgical or therapeutic purposes require a high degree of safety and effectiveness. Software is critical component of many such medical devices. The software architecture of a system defines organizational structure and the runtime characteristic of the application used to control the operation of the system and provides a set of frameworks that are used to develop that. As such, the design of software architecture is a critical element in achieving the intended functionality, performance, and safety requirements of a medical device. This architecture uses object-oriented design techniques, which model the underlying system as a set of …