Open Access. Powered by Scholars. Published by Universities.®

Optometry Commons™

Open Access. Powered by Scholars. Published by Universities.®

716 Full-Text Articles 1,896 Authors 316,714 Downloads 71 Institutions

All Articles in Optometry

Faceted Search

716 full-text articles. Page 31 of 32.

Cessation Of Soft Contact Lens Wear Prior To Refractive Laser:Is Two Weeks Enough?, Aoife Lloyd McKernan, Luisa Simo Mannion, Linda Moore 2011 Technological University Dublin

Cessation Of Soft Contact Lens Wear Prior To Refractive Laser:Is Two Weeks Enough?, Aoife Lloyd Mckernan, Luisa Simo Mannion, Linda Moore

Other

No abstract provided.


Cessation Of Soft Contact Lens Wear Prior To Refractive Laser- Is Two Weeks Long Enough?, Aoife Lloyd McKernan, Luisa Simo Mannion, Linda Moore 2011 Technological University Dublin

Cessation Of Soft Contact Lens Wear Prior To Refractive Laser- Is Two Weeks Long Enough?, Aoife Lloyd Mckernan, Luisa Simo Mannion, Linda Moore

Other

No abstract provided.


Evaluation Of Ophthalmic Technicians, Refractive Service Providers In Mozambique, Kajal Shah 2011 Technological University Dublin

Evaluation Of Ophthalmic Technicians, Refractive Service Providers In Mozambique, Kajal Shah

Conference Papers

Background

One of the solutions to creating sustainable eye care structures is education of personnel.The Technological University Dublin (DIT) with ICEE (International Centre of Eyecare Education) is developing and implementing a sustainable model for optometric education and eye care service delivery in Unilurio in Mozambique.The Mozambique Eyecare Project aims to train Mozambique’s first professional optometrists who will provide a sustainable and comprehensive eye-care system as an integral part of the national health system. Mozambique currently has only 15 ophthalmologists for a population of 21 million and 34 trained Ophthalmic Technicians the only providers of refraction services within the local health …


Visionary Fall 2011, College of Optometry 2011 Nova Southeastern University

Visionary Fall 2011, College Of Optometry

Visionary

No abstract provided.


Primary School Vision Screening Involving Teachers In Nampula, Mozambique, Aoife Phelan, Lisa O'Donoghue, Kathryn Saunders, Stephen Thompson, Vivien Ocampo, Kevin Naidoo, James Loughman 2011 Technological University Dublin

Primary School Vision Screening Involving Teachers In Nampula, Mozambique, Aoife Phelan, Lisa O'Donoghue, Kathryn Saunders, Stephen Thompson, Vivien Ocampo, Kevin Naidoo, James Loughman

Conference Papers

Purpose: There is no plan for a national child eye care programme or existing human resource infrastructure to address the immediate challenge of child eye health in Mozambique.This study aims to design, implement and evaluate a school based pediatric vision screening service, to identify those in need of eye care services, among Mozambique’s 11,561,000 children.

Methods: Primary School Screening took place in three schools in Nampula, Mozambique in September 2010 and March 2011. The children’s vision was screened by an optometry student, optometrist or teacher with Log MAR ETDRS letters at 4 Meters. Ophthalmoscopy was performed on all children by …


Visionary Spring 2011, College of Optometry 2011 Nova Southeastern University

Visionary Spring 2011, College Of Optometry

Visionary

No abstract provided.


A Review Of The Evidence Germane To The Putative Protective Role Of The Macular Carotenoids For Age-Related Macular Degeneration, Sarah Sabour-Pickett, John Nolan, James Loughman, Stephen Beatty 2011 Technological University Dublin

A Review Of The Evidence Germane To The Putative Protective Role Of The Macular Carotenoids For Age-Related Macular Degeneration, Sarah Sabour-Pickett, John Nolan, James Loughman, Stephen Beatty

Articles

There is a consensus that age-related macular degeneration (AMD) is the result of (photo)- oxidative-induced retinal injury and its inflammatory sequelae, the latter being influenced by genetic background. The dietary carotenoids, lutein (L), zeaxanthin (Z), and meso-zeaxanthin (meso-Z), accumulate at the macula, where they are collectively known as macular pigment (MP). The anatomic (central retinal), biochemical (anti-oxidant) and optical (short-wavelength- filtering) properties of this pigment have generated interest in the biologically plausible rationale that MP may confer protection against AMD. Level 1 evidence has shown that dietary supplementation with broad-spectrum anti-oxidants results in risk reduction for AMD progression. Studies have …


Addressing The Burden Of Uncorrected Refractive Error In Mozambique, Stephen Thompson, James Loughman, Prasidh Ramson, Luigi Bilotti, Geoff Harris, Kovin Naidoo 2011 Technological University Dublin

Addressing The Burden Of Uncorrected Refractive Error In Mozambique, Stephen Thompson, James Loughman, Prasidh Ramson, Luigi Bilotti, Geoff Harris, Kovin Naidoo

Conference Papers

A situational analysis indicates a lack of eye health personnel who can and do refract. The logical course of action would be to train more eye health personnel. A conservative estimated annual burden of URE in lost productivity in Mozambique is $14,486,692. To achieve the V2020 target ratio, an extra 184 workers are needed in six provinces analysed.The analysis assumes the existing personnel are well trained and dedicate time to offering a refraction service. It also assumes that the patient receives the care they require. Other aspects of the situational analysis suggest this is currently not always the case. A …


Estimation Of Effective Lens Position Using A Method Independent Of Preoperative Keratometry Readings, I. Dooley, S. Charalampidou, John Nolan, James Loughman, Molly Breen, Stephen Beatty 2011 Waterford Regional Hospital

Estimation Of Effective Lens Position Using A Method Independent Of Preoperative Keratometry Readings, I. Dooley, S. Charalampidou, John Nolan, James Loughman, Molly Breen, Stephen Beatty

Articles

Purpose

To evaluate the validity of a keratometry (K)-independent method of estimating effective lens position (ELP) before phacoemulsification cataract surgery.

Setting

Institute of Eye Surgery, Whitfield Clinic, Waterford, Ireland.

Design

Evaluation of diagnostic test or technology.

Methods

The anterior chamber diameter and corneal height in eyes scheduled for cataract surgery were measured with a rotating Scheimpflug camera. Corneal height and anterior chamber diameter were used to estimate the ELP in a K-independent method (using the SRK/T [ELPrs] and Holladay 1 [ELPrh] formulas).

Results

The mean ELP was calculated using the traditional (mean ELPs 5.59 mm …


Supplementation With All Three Macular Carotenoids: Response, Stability, And Safety, Eithne Connolly, Stephen Beatty, James Loughman, Alan Howard, Michael Louw, John Nolan 2011 Waterford Institute of Technology

Supplementation With All Three Macular Carotenoids: Response, Stability, And Safety, Eithne Connolly, Stephen Beatty, James Loughman, Alan Howard, Michael Louw, John Nolan

Articles

Purpose This study was designed to investigate serum and macular response, and safety, to supplementation with meso-zeaxanthin (MZ), lutein (L) and zeaxanthin (Z), the carotenoids that constitute macular pigment (MP).

Materials and Methods 44 healthy subjects were recruited into this randomized, placebo-controlled, clinical trial. Subjects consumed one tablet per day containing 10.6 mg MZ, 5.9 mg L and 1.2 mg Z (Intervention, I group) or placebo (P group). The spatial profile of MP optical density (MPOD) was measured using heterochromatic flicker photometry (HFP), and serum concentrations of L and Z were quantified using high performance liquid chromatography (HPLC). Subjects …


An Evaluation Of A Novel Instrument For Measuring Macular Pigment Optical Density: The Mps 9000, James Loughman, Grainne Scanlon, John Nolan, Veronica O'Dwyer, Stephen Beatty 2011 Technological University Dublin

An Evaluation Of A Novel Instrument For Measuring Macular Pigment Optical Density: The Mps 9000, James Loughman, Grainne Scanlon, John Nolan, Veronica O'Dwyer, Stephen Beatty

Articles

Purpose:  Of the antioxidants found in the human retina, only the macular carotenoid quantities can be estimated noninvasively (albeit in a collective fashion), thus facilitating study of their role in that tissue. The aim of this study was to evaluate concordance between macular pigment optical density (MPOD) values recorded on a commercially available instrument, the MPS 9000, with those of an already validated heterochromatic flicker photometry instrument. Also, we assessed and compared test–retest variability for each instrument.

Methods:  Macular pigment optical density at 0.5 retinal eccentricity was measured using two different heterochromatic flicker photometers, the MPS 9000 and the Macular …


Prognostic Indicators And Outcome Measures For Surgical Removal Of Symptomatic Nonadvanced Cataract, Sofia Charalampidou, James Loughman, John Nolan, Jim Stack, Lorraine Cassidy, Konrad Pesudovs, Stephen Beatty 2011 Whitfield Clinic

Prognostic Indicators And Outcome Measures For Surgical Removal Of Symptomatic Nonadvanced Cataract, Sofia Charalampidou, James Loughman, John Nolan, Jim Stack, Lorraine Cassidy, Konrad Pesudovs, Stephen Beatty

Articles

Objectives:

To report changes in perceived visual functioning after surgery for symptomatic cataract with pre-operative corrected distance visual acuity [CDVA] of 0.4 logMar or better (Snellen equivalent, 20/50) and to investigate the relationship between any observed changes and preoperative physical characteristics and psycho-physical consquences of the lens opacity and any changes in psychophysical findings after the procedure.


Soft Contact Lens-Induced Corneal Warpage, Aoife Lloyd McKernan, Luisa Simo Mannion, Linda Moore 2011 Technological University Dublin

Soft Contact Lens-Induced Corneal Warpage, Aoife Lloyd Mckernan, Luisa Simo Mannion, Linda Moore

Articles

No abstract provided.


The Impact Of Macular Pigment Augmentation On Visual Performance In Normal Subjects: Compass, John Nolan, James Loughman, Akkali Makunda, Jim Stack, Grainne Scanlon, Peter Davison, Stephen Beatty 2011 Waterford Institute of Technology

The Impact Of Macular Pigment Augmentation On Visual Performance In Normal Subjects: Compass, John Nolan, James Loughman, Akkali Makunda, Jim Stack, Grainne Scanlon, Peter Davison, Stephen Beatty

Articles

This study was conducted to investigate whether augmentation of macular pigment (MP) enhances visual performance (VP). 121 normal subjects were recruited. The active (A) group consumed 12 mg of lutein (L) and 1 mg of zeaxanthin (Z) daily. MP optical density (MPOD) was assessed by customized heterochromatic flicker photometry. VP was assessed as best corrected visual acuity (BCVA), mesopic and photopic contrast sensitivity (CS), glare disability, photostress, and subjective visual function. Subjects were assessed at baseline; 3; 6; 12 months (V1, V2, V3 and V4, respectively). Central MPOD increased significantly in the A group (p < 0.05) but not in the placebo group (p > 0.05). This statistically …


Online Amd Research Study For Optometrists: Current Practice In The Republic Of Ireland And Uk, James Loughman, John Nolan, James Stack, Stephen Beatty 2011 Technological University Dublin

Online Amd Research Study For Optometrists: Current Practice In The Republic Of Ireland And Uk, James Loughman, John Nolan, James Stack, Stephen Beatty

Articles

No abstract provided.


Tear Component Interference In Bead-Based Biomarker Assays Using Magnetic Beads, Larezia Denise Williams 2011 University of Alabama at Birmingham

Tear Component Interference In Bead-Based Biomarker Assays Using Magnetic Beads, Larezia Denise Williams

All ETDs from UAB

Cytokines in tears can be biomarkers for ocular inflammation in dry eye subjects. Multiplex bead-based assays measure the concentration of multiple cytokines in a single tear sample. Bio-Rad® polystyrene bead-based assay kits have provided acceptable results for tear samples in this lab. Recently, Bio-Rad decided to replace polystyrene beads with magnetic beads. In earlier experiments in this laboratory, magnetic bead-based as-says did not produce results equivalent to polystyrene bead-based assays. The purpose of this investigation was to modify the magnetic bead-based tear cytokine assay to produce equivalent results to those obtained with the polystyrene bead-based assay. The modifications included running …


Measuring Aniseikonia Using Scattering Filters To Simulate Cataract, Jason Anthony Wilson 2011 University of Alabama at Birmingham

Measuring Aniseikonia Using Scattering Filters To Simulate Cataract, Jason Anthony Wilson

All ETDs from UAB

MEASURING ANISEIKONIA USING SCATTERING FILTERS TO SIMULATE CATARACT JASON WILSON DEPARTMENT OF VISION SCIENCE ABSTRACT The relationship between anisometropia and aniseikonia (ANK) is not well understood. Ametropic cataract patients provide a unique opportunity to study this relationship after undergoing emmetropizing lens extraction. Because light scatter may affect ANK measurement in cataract patients, its effect should also be evaluated. The Basic Aniseikonia Test (BAT) was evaluated using afocal size lenses to produce specific changes in retinal height. Several light scattering devices were then evaluated to determine which produced effects most similar to cataract. Contrast sensitivity and visual acuity (VA) losses were …


Post-Translational Modifications, Structure And Function Of Human Lens Crystallins, Chinwe Asomugha 2011 University of Alabama at Birmingham

Post-Translational Modifications, Structure And Function Of Human Lens Crystallins, Chinwe Asomugha

All ETDs from UAB

Cataract is an opacification of the lens causing reduction in vision over time. It is one of the leading causes of vision loss among adults age 55 and older. The lens is a transparent structure that focuses incoming light onto the retina for visual perception. It has a high protein content, attributed mainly to water-soluble proteins known as crystallins. With age, crystallins undergo post-translational modifications (PTMs) that alter their structural and/or functional properties and, in turn, lead to cataract formation. The purpose of this research was to take a top-down approach in understanding changes in lens proteins with age, starting …


Behavior Of Midbrain Vergence Cells During Stepwise Transfers Of Gaze And Oblique Tracking In Depth, Leah Corthell 2011 University of Alabama at Birmingham

Behavior Of Midbrain Vergence Cells During Stepwise Transfers Of Gaze And Oblique Tracking In Depth, Leah Corthell

All ETDs from UAB

A long standing debate regarding the neural organization of oculomotor control began in the late 1800's with Hering and von Helmholtz proposing two opposing ideologies. Von Helmholtz proposed a monocular structure of the oculomotor circuitry in which each eye receives separate motor commands. Hering offered his law of equal innervation, which states that all eye movements are the sum of binocular vergence and conjugate commands. As a test of Hering's binocular proposal, this project compared the behavior of midbrain vergence cells during: 1) saccade-free stepwise transfers of gaze in depth; 2) combined saccade-vergence eye movements; 3) pure vergence tracking, and …


Psychophysical Impact And Optical And Morphological Characteristics Of Symptomatic Non-Advanced Cataract., S. Charalampidou, J. Nolan, James Loughman, J. Stack, Lorraine Cassidy, S. Beatty 2011 University of Dublin, Trinity College

Psychophysical Impact And Optical And Morphological Characteristics Of Symptomatic Non-Advanced Cataract., S. Charalampidou, J. Nolan, James Loughman, J. Stack, Lorraine Cassidy, S. Beatty

Articles

Purpose To investigate whether
/="/">psychophysical, morphological, and/or optical
/="/">characteristics of symptomatic non-advanced
/="/">cataract are complementary to, or more
/="/">appropriate than, visual acuity (VA) for the
/="/">purposes of recording visual data that reflect
/="/">subjective visual difficulty in patients with
/="/">cataract that exhibit relative sparing of high
/="/">contrast acuity (0.4 logarithm of minimal angle
/="/">of resolution (logMAR) scale or better).


Digital Commons powered by bepress