Open Access. Powered by Scholars. Published by Universities.®
Biomechanics and Biotransport Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Mechanical Engineering (120)
- Medicine and Health Sciences (106)
- Biomedical Devices and Instrumentation (91)
- Biomechanical Engineering (86)
- Life Sciences (82)
-
- Molecular, Cellular, and Tissue Engineering (56)
- Other Biomedical Engineering and Bioengineering (54)
- Biomaterials (53)
- Biological Engineering (44)
- Physical Sciences and Mathematics (40)
- Medical Specialties (28)
- Bioimaging and Biomedical Optics (23)
- Kinesiology (22)
- Rehabilitation and Therapy (22)
- Chemical Engineering (21)
- Anatomy (20)
- Biochemistry, Biophysics, and Structural Biology (20)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (19)
- Biomechanics (19)
- Materials Science and Engineering (18)
- Applied Mechanics (17)
- Cell and Developmental Biology (16)
- Diseases (16)
- Electrical and Computer Engineering (15)
- Physics (15)
- Engineering Science and Materials (14)
- Physiology (14)
- Institution
-
- California Polytechnic State University, San Luis Obispo (65)
- University of Arkansas, Fayetteville (41)
- University of Denver (41)
- University of Nebraska - Lincoln (31)
- University of Nebraska at Omaha (31)
-
- Old Dominion University (30)
- Purdue University (28)
- Virginia Commonwealth University (26)
- University of Kentucky (24)
- Clemson University (22)
- City University of New York (CUNY) (21)
- The University of Akron (17)
- University of Central Florida (13)
- Cleveland State University (12)
- University of Alabama in Huntsville (11)
- University of Connecticut (10)
- Boise State University (9)
- Bucknell University (8)
- Michigan Technological University (8)
- Technological University Dublin (8)
- University of Louisville (7)
- Embry-Riddle Aeronautical University (5)
- Grand Valley State University (5)
- Kennesaw State University (5)
- New Jersey Institute of Technology (5)
- University of Dayton (5)
- Brigham Young University (4)
- Loma Linda University (4)
- Marquette University (4)
- Marshall University (4)
- Keyword
-
- Biomechanics (80)
- Daniel Felix Ritchie School of Engineering and Computer Science (32)
- Mechanical and Materials Engineering (26)
- Knee (17)
- Gait (14)
-
- Finite element (12)
- Bone (11)
- Kinematics (11)
- Microfluidics (11)
- Engineering (10)
- Finite element analysis (10)
- Mechanotransduction (10)
- Tissue Engineering (10)
- Biological sciences (9)
- Biomedical (9)
- Mechanobiology (9)
- OpenSim (9)
- Biomedical Engineering (8)
- In vitro (8)
- Osteoarthritis (8)
- Ankle (7)
- Applied sciences (7)
- Laxity (7)
- Motion capture (7)
- Concussion (6)
- Electromyography (6)
- Hip (6)
- Injury (6)
- 3D printing (5)
- Biomedical engineering (5)
- Publication Year
- Publication
-
- Master's Theses (49)
- Electronic Theses and Dissertations (46)
- UNO Student Research and Creative Activity Fair (31)
- Theses and Dissertations (30)
- Biomedical Engineering Undergraduate Honors Theses (21)
-
- Biomedical Engineering (17)
- Theses and Dissertations--Biomedical Engineering (17)
- Williams Honors College, Honors Research Projects (17)
- Dissertations and Theses (16)
- Graduate Theses and Dissertations (15)
- All Dissertations (12)
- Ravi Saraf Publications (12)
- PRC-Affiliated Research (11)
- All Theses (10)
- Boise State University Theses and Dissertations (9)
- Open Access Theses (9)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (8)
- Mechanical & Aerospace Engineering Faculty Publications (7)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (6)
- Dissertations, Master's Theses and Master's Reports (6)
- Faculty Journal Articles (6)
- Honors Undergraduate Theses (6)
- Natural Knee Data (6)
- Open Access Dissertations (6)
- Publications and Research (6)
- ETD Archive (5)
- Masters Theses (5)
- Mechanical & Aerospace Engineering Theses & Dissertations (5)
- Articles (4)
- Dissertations (4)
- Publication Type
- File Type
Articles 511 - 540 of 583
Full-Text Articles in Biomechanics and Biotransport
Computational Biomechanical Modeling Of The Human Knee During Kneeling, Tariq R. Abo-Alhol
Computational Biomechanical Modeling Of The Human Knee During Kneeling, Tariq R. Abo-Alhol
Electronic Theses and Dissertations
Total knee replacement benefits patients who suffer from severe knee pain or joint stiffness and other joint related illnesses that limit everyday activities. There has been an increase in the number of procedures performed each year and a need to evaluate the performance of these implants during specialized activities such as kneeling. Most computational studies lack insight into inter-patient variability and the results do not apply to large population. This study developed: (1) three-dimensional explicit finite element (FE) models to investigate natural and implanted knee joint kinematics and bone strain and (2) a platform to enable population-based evaluation by combining …
Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne
Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne
Mechanical & Aerospace Engineering Theses & Dissertations
Subtalar instability may be caused by various ligamentous injuries. Combined instability at the ankle and subtalar joint is not adequately diagnosed. Further, isolated subtalar instability is usually misdiagnosed which may lead to long term damage to the joint. Developing a non-invasive and clinically practical tool to diagnose subtalar joint instability would be an important asset. The ability of an ankle brace, a common treatment for hindfoot instability, to promote stability for the subtalar joint was not well established. The purposes of this study were to 1) assess the kinematics of the subtalar, ankle, and hindfoot in the presence of isolated …
Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges
Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges
Biomedical Engineering
Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Biomedical Engineering
Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …
Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino
Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino
Master's Theses
Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Master's Theses
With more young adults requiring total hip
arthroplasties the need for bone saving implants becomes
more important. The Zimmer Fitmore is a new bone saving
implant that utilizes an implantation technique that
reduces the damage to the muscle tissue allowing for
patients to have a short recovery time as well as a new
design that allows it to rest on the medial cortex. There
has been anecdotal evidence that this device leads to early
revision within six months of implantation due to failures
occurring in the medial cortex. The main goal of this
study was to computationally model the Zimmer …
A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll
A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll
Biomedical Engineering
Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …
The Effects Of Toning Shoes On The Postural Stability Of Women, Kevin Farley, Audrey Niverson, Renee Rogge
The Effects Of Toning Shoes On The Postural Stability Of Women, Kevin Farley, Audrey Niverson, Renee Rogge
Rose-Hulman Undergraduate Research Publications
Postural stability is the ability to maintain an upright posture and to keep the center of pressure (COP) within the limits of the body’s base of support. It is maintained through the dynamic integration of muscle activity and joint position. The foot, and therefore footwear, also plays a critical role in postural stability. The goal of this study is to determine the effects of toning shoes on the postural stability of women.
Effect Of Rolling On Viscoelastic Fluids Using A Novel Testing Device, Aswini Mangadu
Effect Of Rolling On Viscoelastic Fluids Using A Novel Testing Device, Aswini Mangadu
Dissertations and Theses
The purpose of this research thesis project was to develop a mechanical testing device that could enable us to load articular cartilage with a rolling/sliding motion. This novel device was then used to observe the effect of a rolling motion on the fluid film thickness of different lubricants (motor oil, synovial fluid and Hyaluronic Acid (HA)) to varying loads (1kg, 2,kg, 3kg and 4kg) and speeds (10, 25, 48 and 91 mm/s) applied on the sample fluids for 10 cycles. We were able to examine the effect of different speeds within each load for each of the fluid that was …
Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren
Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren
Mechanical & Aerospace Engineering Faculty Publications
A three-dimensional (3D) computational fluid dynamics study of shear rates around distal end-to-side anastomoses has been conducted. Three 51% and three 75% cross-sectional area-reduced 6 mm cylinders were modeled each with a bypass cylinder attached at a 30-degree angle at different placements distal to the constriction. Steady, incompressible, Newtonian blood flow was assumed, and the full Reynolds-averaged Navier-Stokes equations, turbulent kinetic energy, and specific dissipation rate equations were solved on a locally structured multiblock mesh with hexahedral elements. Consequently, distal placement of an end-to-side bypass graft anastomosis was found to have an influence on the shear rate magnitudes. For the …
The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood
The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood
Theses and Dissertations--Biomedical Engineering
The effects of mechanical forces on endothelial cell function and behavior are well documented, but have not been fully characterized. Specifically, fluid pressure has been shown to elicit physical and chemical responses known to be involved in the initiation and progression of endothelial cell-mediated vascularization. Central to the process of vascularization is the formation of tube-like structures. This process—tubulogenesis—is essential to both the physiological and pathological growth of tissues. Given the known effects of pressure on endothelial cells and its ubiquitous presence in the vasculature, we investigated pressure as a magnitude-dependent parameter for the regulation of endothelial tubulogenic activity. To …
Bone Properties By Nanoindentation In Mild And Severe Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Jeffrey M. Toth, Peter Smith, Gerald F. Harris
Bone Properties By Nanoindentation In Mild And Severe Osteogenesis Imperfecta, Carolyne Albert, John Jameson, Jeffrey M. Toth, Peter Smith, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
Background
Osteogenesis imperfecta is a heterogeneous genetic disorder characterized by bone fragility. Previous research suggests that impaired collagen network and abnormal mineralization affect bone tissue properties, however, little data is yet available to describe bone material properties in individuals with this disorder. Bone material properties have not been characterized in individuals with the most common form of osteogenesis imperfecta, type I.
Methods
Bone tissue elastic modulus and hardness were measured by nanoindentation in eleven osteotomy specimens that were harvested from children with osteogenesis imperfecta during routine surgeries. These properties were compared between osteogenesis imperfecta types I (mild, n = …
Designing For Success: Developing Engineers Who Consider Universal Design Principles, Kimberly Edginton Bigelow
Designing For Success: Developing Engineers Who Consider Universal Design Principles, Kimberly Edginton Bigelow
Mechanical and Aerospace Engineering Faculty Publications
Engineers must design for a diverse group of potential users of their products; however, engineering curricula rarely include an emphasis on universal design principles. This research article details the effectiveness of a design project implemented in a first-year engineering course in an effort to raise awareness of the need for engineers to be more inclusive when designing. Students were asked to apply universal design principles to redesign an engineering laboratory to make it more usable to all, including individuals with disabilities who use the room. A representative from the university’s disability services staff, as well as individuals with first-hand experience …
The Biomechanical Role Of Scaffolds In Augmented Rotator Cuff Tendon Repairs, Amit Aurora, Jesse A. Mccarron, Antonie J. Van Den Bogert, Jorge E. Gatica, Joseph P. Iannotti, Kathleen A. Derwin
The Biomechanical Role Of Scaffolds In Augmented Rotator Cuff Tendon Repairs, Amit Aurora, Jesse A. Mccarron, Antonie J. Van Den Bogert, Jorge E. Gatica, Joseph P. Iannotti, Kathleen A. Derwin
Mechanical Engineering Faculty Publications
Background
Scaffolds continue to be developed and used for rotator cuff repair augmentation; however, the appropriate scaffold material properties and/or surgical application techniques for achieving optimal biomechanical performance remains unknown. The objectives of the study were to simulate a previously validated spring-network model for clinically relevant scenarios to predict: (1) the manner in which changes to components of the repair influence the biomechanical performance of the repair and (2) the percent load carried by the scaffold augmentation component.
Materials and methods
The models were parametrically varied to simulate clinically relevant scenarios, namely, changes in tendon quality, altered surgical technique(s), and …
A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen
A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen
Master's Theses
A new detection reagent that could possibly augment or replace antibodies research and diagnosis methods are aptamers. Aptamers are ssDNA, RNA or polypeptide constructs that function like active antibodies. Antibodies and aptamers both specifically bind to selected target molecules, and as such they enable the detection or targeting of the presence or absence of a specific antigen.
In order to ensure that ssDNA aptamers perform similarly to antibodies, anti-VEGF-A polyclonal antibody and anti-VEGF-A ssDNA aptamer were evaluated against vascular endothelial growth factor A (VEGF-A) using Surface Plasmon Resonance (SPR). It was hypothesized that the anti-VEGF-A aptamer had the same, if …
Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham
Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham
Biomedical Engineering
No abstract provided.
Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel
Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel
Master's Theses
Experimental results show that collagen fibers exhibit stress relaxation under tension and a highly anisotropic distribution. To further develop the earlier model of Stender [1], the collagen constituent was updated to reflect its intrinsic viscoelasticity and anisotropic distribution, and integrated with an existing mixture model with glycosaminoglycans and ground substance matrix. A two-term Prony series expansion of the quasi-linear viscoelastic model was chosen to model the viscoelastic properties of the collagen fibers. Material parameters were determined by using the simplex method to minimize the sum of squared errors between model results and experimental stress relaxation data of tissue in tension. …
A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils
Master's Theses
Biomechanical risk factors are physical stressors that act on the neuromuscular structures of the human body and are present in all occupational settings. Repetition and intensity of tasks performed can magnify the effects of the biomechanical risks that a worker is exposed to.
After reviewing the current literature on ergonomics in laparoscopic surgery it was clear that a comprehensive approach to quantitatively reporting on the biomechanical risk factors associated with surgical hand tools had never been performed. Utilizing an opto-electronic motion capture system meant the exact surgeon posture was recorded during simulated surgical tasks. Electromyography was used to evaluate muscle …
Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio
Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio
Master's Theses
Accurate tracking of hand grip force is an important consideration needed for a robust understanding in the study of human biomechanics. One aspect where it proves useful is in hand-arm vibration, such as from gripping a power tool. Depending on how firmly the user is gripping the tool, they may change their exposure levels to the tool vibration, which can lead to potential disorders such as Hand-Arm Vibration Syndrome (HAVS).
A small, battery powered portable force unit has been developed to supply power to, and condition, the signals from eight thin-film force sensors. This gives a better understanding of the …
Simulation Of Lower Limb Axial Arterial Length Change During Locomotion, Melissa D. Young, Matthew C. Streicher, Richard J. Beck, Antonie J. Van Den Bogert, Azita Tajaddini, Brian L. Davis
Simulation Of Lower Limb Axial Arterial Length Change During Locomotion, Melissa D. Young, Matthew C. Streicher, Richard J. Beck, Antonie J. Van Den Bogert, Azita Tajaddini, Brian L. Davis
Mechanical Engineering Faculty Publications
The effect of external forces on axial arterial wall mechanics has conventionally been regarded as secondary to hemodynamic influences. However, arteries are similar to muscles in terms of the manner in which they traverse joints, and their three-dimensional geometrical requirements for joint motion. This study considers axial arterial shortening and elongation due to motion of the lower extremity during gait, ascending stairs, and sitting-to-standing motion. Arterial length change was simulated by means of a graphics based anatomic and kinematic model of the lower extremity. This model estimated the axial shortening to be as much as 23% for the femoropopliteal arterial …
Mechanical Properties Of Bone Due To Sost Expression: A 3-Point Bending Assessment Of Murine Femurs, Kainoa John Peterson
Mechanical Properties Of Bone Due To Sost Expression: A 3-Point Bending Assessment Of Murine Femurs, Kainoa John Peterson
Master's Theses
Sclerostin, a protein coded for by the SOST gene, is an osteocyte-expressed negative regulator of bone formation. The absence of SOST in the genome may have an effect on bone formation both during skeletal maturation and full maturity. This study attempts to determine significant differences in the mechanical properties of bone that expresses SOST compared to bone that does not. One hundred femur samples from 6, 8, and 12 month old mice were obtained from Lawrence Livermore National Labs and loaded until failure using three-point bending. Results showed significant differences in treatment group effects for cross sectional area, yield force, …
The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink
The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink
UNLV Theses, Dissertations, Professional Papers, and Capstones
Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …
Electrokinetic Transport Phenomena In Nanofluidic Devices, Mingkan Zhang
Electrokinetic Transport Phenomena In Nanofluidic Devices, Mingkan Zhang
Mechanical & Aerospace Engineering Theses & Dissertations
Nanofluidic devices have wide potential applications in biology, chemistry and medicine, and have been proven to be very valuable in sensing biological particles (e.g., DNA and proteins) due to their efficiency, sensitivity and portability. Electrokinetic control of ion, fluid, and particle transport by using only electric field is the most popular method employed in nanofluidic devices. A comprehensive understanding of the electrokinetic ion, fluid, and particle transport in nanofluidics is essential for developing nanofluidic devices for the detection of single molecules, such as the next generation nanopore-based DNA sequencing technology. This research explored numerical simulation of electrokinetic ion and fluid …
Bisphosphonates And Bone Microdamage, William A. Caruthers
Bisphosphonates And Bone Microdamage, William A. Caruthers
Theses and Dissertations--Biomedical Engineering
Osteoporosis is a significant healthcare issue due to the increasing elderly population. Bisphosphonates are used to treat osteoporosis by reducing the rate of resorption, increasing bone mineral density (BMD) and thereby reducing fracture risk. Long-term bisphosphonate treatment, however, has been associated with low-energy fractures. Bone microdamage may provide a partial explanation for one of the mechanisms responsible for these fractures since it has been shown to reduce bone toughness, fracture resistance, and bone strength. The goal of this study was to quantify the changes in bone microdamage parameters with the duration of bisphosphonate treatment. This study selected, stained, and histomorphometrically …
Effect Of Prostaglandin E2 On Mechanical Stresses Applied By Mc3t3-E1 Osteoblast-Like Cells On A Soft Hydrogel Substrate, Abhijit Deb Roy
Effect Of Prostaglandin E2 On Mechanical Stresses Applied By Mc3t3-E1 Osteoblast-Like Cells On A Soft Hydrogel Substrate, Abhijit Deb Roy
Master's Theses
Osteoblasts are sensitive to mechanical stimuli and release Prostaglandin E2 (PGE2) when exposed to a fluid shear stress. The exact mechanism by which these cells sense mechanical stress is not well established. A study of the stresses applied by the osteoblasts, under the influence of PGE2, on a hydrogel provided information regarding intercellular-communication via changes in the substrate surface pattern.
A digital image correlation program was developed using the Levenberg-Marquardt optimization algorithm to analyze images and compare the deformations between pairs of images. Comparisons of images before and after the addition of PE2 to the media showed differences in the …
Automation Of Orthodontic Wire Tester For Performing Three Point Bending Tests, Adithya Venkatesan
Automation Of Orthodontic Wire Tester For Performing Three Point Bending Tests, Adithya Venkatesan
Master's Theses
Abstract
Understanding the biomechanical factors in orthodontics is important in order to improve the overall effectiveness of actual clinical treatment. An accurate method to study the threedimensional (3D) force systems and the resulting movements of teeth during orthodontic treatment is needed along with the understanding of the material properties of any orthodontic wire. Until recently, most of the orthodontic biomechanics literature was limited to twodimensional experimental studies. Recent advances in threedimensional computer modeling have also been developed but have been limited to the manual control of tooth movement. Overall, there is very little published evidence in the literature on the …
Finite Element Analysis Of The Effect Of Low-Speed Rear End Collisions On The Medial Meniscus, Daniel J. Tichon
Finite Element Analysis Of The Effect Of Low-Speed Rear End Collisions On The Medial Meniscus, Daniel J. Tichon
Master's Theses
Low-speed, rear end vehicle collisions can inflict soft tissue damage to the passenger’s knees, especially the medial meniscus, which has been previously unexplained in published literature. It is difficult to determine if factors such as age or other injury was the primary cause of the injury or if the accident acutely caused the meniscal tear. Rear end collisions may produce a combination of compressive loading and torque about the knee that will injure the medial meniscus during the initial impact and the rebound phase. The purpose of this study is to determine if it is possible for rear end low-speed …
The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito
The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito
Master's Theses
Adolescent Idiopathic Scoliosis (AIS) is a three dimensional deformity of the spine that causes abnormal curvatures in the coronal and sagittal planes and abnormal vertebral rotations. The gold standard for diagnosing and tracking the progression of the deformity is through the use of repeated radiography and a patient can receive upwards of fifteen radiographic series over the course of treatment, which exposes this population to an increased risk of radiation-dependent complications.
This thesis presents the necessary calculations and the marker set required to make the motion capture technology a viable alternative to radiographs, in an effort to reduce the patient’s …
Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler
Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Gas emboli are a clinical issue often encountered in the space exploration, marine construction, and medical fields. Individuals involved with these disciplines will often have asympomatic gas emboli circulating throughout their bodies on a regular basis. A study into the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis in humans is thus presented. This research utilized a custom built cardiovascular flow simulator and accompanying data acquisition system to experimentally determine the influence of gas emboli under varied circumstances on the mean wall shear stress of a tube in-vitro. A directly inverse relationship between gas embolus presence in …
Ultrasonic And Stereo-Optical Characterization Techniques For Applications In Mechanical Testing, Jonathan M. Hein
Ultrasonic And Stereo-Optical Characterization Techniques For Applications In Mechanical Testing, Jonathan M. Hein
Department of Engineering Mechanics: Dissertations, Theses, and Student Research
This thesis considers methods developed based on ultrasonic reflections from interfaces and stereo-optical surface strain measurements to study the mechanical characterization of materials and bodies. The ultrasonic method is used to characterize wave speed and attenuation for highly attenuating samples. The stereo-optical strain measurements are used to characterize the effects of genes on mechanical properties of bone, and the dynamic characterization of blast waves in the UNL Shock Wave Trauma Mechanics facility.
A method is described and developed for characterizing the wave speed and attenuation spectrums from reflected waves from the contact surface with an unknown material. The method is …