Open Access. Powered by Scholars. Published by Universities.®
Biomechanics and Biotransport Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Orthodontics and Orthodontology (3)
- Biomedical Devices and Instrumentation (2)
- Life Sciences (2)
- Medical Specialties (2)
- Radiology (2)
-
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (1)
- Animal Experimentation and Research (1)
- Computer Engineering (1)
- Multivariate Analysis (1)
- Other Dentistry (1)
- Physical Sciences and Mathematics (1)
- Physiology (1)
- Research Methods in Life Sciences (1)
- Statistics and Probability (1)
Articles 1 - 4 of 4
Full-Text Articles in Biomechanics and Biotransport
New In Vivo And In Vitro Techniques For Quantification Of Lateral Force Levels That Cause Implants To Fail : A Progress Report On Monkey Research, V. Leroy Leggitt
New In Vivo And In Vitro Techniques For Quantification Of Lateral Force Levels That Cause Implants To Fail : A Progress Report On Monkey Research, V. Leroy Leggitt
Loma Linda University Electronic Theses, Dissertations & Projects
Two new techniques for quantification of forces generated by an expansion screw apparatus placed between pairs of cylindrical endosseous titanium implants are described, along with preliminary data gained from their use in Macaca rhesus monkeys. Strain gages were bonded to the expansion apparatus and were calibrated either directly by micro load cell, or indirectly by Instron Machine to reflect the applied force.
Immediate loads of up to 6 kilograms have been applied to the implants with no increase in mobility as verified by a Periotest device. No previous studies on the orthodontic uses of implants have evaluated in vivo forces …
A Comparative Analysis Of Intrusion Of Incisor Teeth Achieved In Adults And Children According To Facial Type, Ronald L. Otto
A Comparative Analysis Of Intrusion Of Incisor Teeth Achieved In Adults And Children According To Facial Type, Ronald L. Otto
Loma Linda University Electronic Theses, Dissertations & Projects
A comparison of incisor intrusion achieved in deep bite adults and children was made. Facial type was also examined for affect upon intrusion achieved. Fifty-five cases treated with Bioprogressive mechanics were studied cephalometrically, including twenty-four adults and thirty-one children. Neither age nor facial type was found to be statistically related to the amount of incisor intrusion achieved in this sample. A method of measuring intrusion at the root apices was devised which was felt to give a more accurate indication of actual bodily intrusion. More external root changes during treatment were observed for adults than for growing children. Wide latitude …
A Method Of Analyzing Mandibular Movement, Richard B. Mccoy
A Method Of Analyzing Mandibular Movement, Richard B. Mccoy
Loma Linda University Electronic Theses, Dissertations & Projects
Mandibular movement is considered to be a fundamental factor in the study, analysis, and treatment of occlusion. For many years, dentists have realized that dental health depends upon the compatibility of mandibular movements and occlusion. This realization has led to the development of new methods and techniques for recording accurately and scientifically the movements of the mandible. In order for this data to be of scientific value, it must be stored in a usable form which is easily available for analysis.
The purpose of this research project was to develop a procedure for storing and recalling mandibular-movement information. Before such …
A Procedure For The Measurement Of Glosso-Maxillary Forces, Howard L. Lilly Jr.
A Procedure For The Measurement Of Glosso-Maxillary Forces, Howard L. Lilly Jr.
Loma Linda University Electronic Theses, Dissertations & Projects
The purpose of this investigation was to develop a clinically feasible procedure for recording the magnitudes of glosso-maxillary forces at four palatal loci using an electronic transducer system described by Lear et, al. (1965). Of particular interest was the development of a convenient and accurate calibration device for both intraoral and extraoral application. A further object of interest was the effect an acrylic carrier plate might introduce to the magnitude of force response. Finally whether or not any significant adaptation to the carrier plate or to the transducers occurs during a reasonable testing period (six to seven hours).
A calibration …