Open Access. Powered by Scholars. Published by Universities.®

Biomechanics and Biotransport Commons

Open Access. Powered by Scholars. Published by Universities.®

Electrical and Computer Engineering

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 1 - 15 of 15

Full-Text Articles in Biomechanics and Biotransport

Using Ai To Predict Energy Expenditure In Lower Limb Prosthesis Users, Nelly Diaz, Siem Hadish Apr 2026

Using Ai To Predict Energy Expenditure In Lower Limb Prosthesis Users, Nelly Diaz, Siem Hadish

Posters - 2026

• Computer vision has evolved from simple image classification and object detection to analyzing human motion and biomechanics (1). • CNN’s are usually focused on image classification, but, in this case, we are not asking the model if a person is walking. • Many real-world problems require regression: Predicting a continuous number like energy expenditure of walking is a complex task. • It is essential for Prosthetists to understand energy expenditure of their prosthetic patients (2). • An amputee may use 20-30% more energy to walk. • In this project, we developed an AI model to analyze human motion and …


Hand Movement Analysis For Surgical Suturing Skill Assessment, Amir Mehdi Shayan May 2024

Hand Movement Analysis For Surgical Suturing Skill Assessment, Amir Mehdi Shayan

All Theses

To enhance patient safety, surgical education is increasingly incorporating simulation for formative skills assessment and training. However, many standardized assessment tools rely on human raters for performance assessment, which is resource-intensive and subjective. Simulators that provide automated and objective metrics from sensor data can address this limitation. This thesis presents an instrumented bench suturing simulator, patterned after the Clock Face (CF) radial suturing model from the Fundamentals of Vascular Surgery (FVS), for automated and objective assessment of open suturing skills by particularly focusing on biomechanical analysis of hand movements. For this research, 97 participants (35 attending surgeons and fellows, 32 …


Reducing Food Scarcity: The Benefits Of Urban Farming, S.A. Claudell, Emilio Mejia Dec 2023

Reducing Food Scarcity: The Benefits Of Urban Farming, S.A. Claudell, Emilio Mejia

Journal of Nonprofit Innovation

Urban farming can enhance the lives of communities and help reduce food scarcity. This paper presents a conceptual prototype of an efficient urban farming community that can be scaled for a single apartment building or an entire community across all global geoeconomics regions, including densely populated cities and rural, developing towns and communities. When deployed in coordination with smart crop choices, local farm support, and efficient transportation then the result isn’t just sustainability, but also increasing fresh produce accessibility, optimizing nutritional value, eliminating the use of ‘forever chemicals’, reducing transportation costs, and fostering global environmental benefits.

Imagine Doris, who is …


Development Of A Fish Robot Equipped With Novel 3d-Printed Soft Bending Actuators, Steven Steele, Jorge Diaz Rodriguez, Sharun Sripathy, Turaj Ashuri, Saleh Gharaie, Yusun Chang, Amir Ali Amiri Moghadam Apr 2023

Development Of A Fish Robot Equipped With Novel 3d-Printed Soft Bending Actuators, Steven Steele, Jorge Diaz Rodriguez, Sharun Sripathy, Turaj Ashuri, Saleh Gharaie, Yusun Chang, Amir Ali Amiri Moghadam

Symposium of Student Scholars

This paper reports on design and fabrication of a novel soft fish robot. Application of soft actuators for the fish tail will generates continuum bending motion which resembles the natural motion of the fish. However, most soft actuator mechanisms are complex and have low efficiency. Thus, to address this issue we have developed a 3D printed soft bending actuator which can be actuated with an electromotor. The basic design idea of the soft bending actuator is explained, and iteration of the design showed to create the desired motion for the soft tail. The soft actuator has been successfully integrated with …


Long-Range Aceo Phenomena In Microfluidic Channel, Diganta Dutta, Keifer Smith, Xavier Palmer Jan 2023

Long-Range Aceo Phenomena In Microfluidic Channel, Diganta Dutta, Keifer Smith, Xavier Palmer

Electrical & Computer Engineering Faculty Publications

Microfluidic devices are increasingly utilized in numerous industries, including that of medicine, for their abilities to pump and mix fluid at a microscale. Within these devices, microchannels paired with microelectrodes enable the mixing and transportation of ionized fluid. The ionization process charges the microchannel and manipulates the fluid with an electric field. Although complex in operation at the microscale, microchannels within microfluidic devices are easy to produce and economical. This paper uses simulations to convey helpful insights into the analysis of electrokinetic microfluidic device phenomena. The simulations in this paper use the Navier–Stokes and Poisson Nernst–Planck equations solved using COMSOL …


Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda May 2022

Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda

Biomedical Engineering

Falls among the aging population occur every single day, with 1 in every 5 resulting in some injury and 300,000 hospitalized every year with a hip fracture [1]. The most popular and effective way to mitigate these falls is through physical therapist intervention. However, with the increased popularity in telerehab, many patients at risk for falls cannot accurately convey their gait tendencies to their physical therapists from the comfort of their home or while not in direct contact with the PT. A device like an insole, implanted with force sensors, which measures different parts of a patient’s foot, could convey …


New Force Transducer For Mitral Valve Chordae Tendinea, Joseph Berryman May 2021

New Force Transducer For Mitral Valve Chordae Tendinea, Joseph Berryman

Biomedical Engineering Undergraduate Honors Theses

In order to inform the future of mitral valve repair and replacement, more investigation into the mechanics of the sub-valvular structure is needed. Understanding the roles of each chord during valve closure requires a sensor capable of detecting these small forces with enough sensitivity to determine the characteristics of each of the chordal types. The focus of the cantilever force transducer is to maximize this sensitivity while also minimizing the invasiveness of the sensor on the overall function of the chord. The design utilizes flexible yet strong 3D printed resin and cantilever arms to improve the strain exerted on a …


Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand Jan 2021

Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand

Dissertations and Theses

Localized chemical delivery plays an essential role in the fundamental information transfers within biological systems. Thus, the ability to mimic the natural chemical signal modulation would provide significant contributions to understand the functional signaling pathway of biological cells and develop new prosthetic devices for neurological disorders. In this paper, we demonstrate a light-controlled hydrogel platform that can be used for localized chemical delivery in a high spatial resolution. By utilizing the photothermal behavior of graphene-hydrogel composites confined within micron-sized fluidic channels, patterned light illumination creates the parallel and independent actuation of chemical release in a group of fluidic ports. The …


Developing An Optomechanical Approach For Characterizing Mechanical Properties Of Single Adherent Cells, Ali Mehrnezhad May 2019

Developing An Optomechanical Approach For Characterizing Mechanical Properties Of Single Adherent Cells, Ali Mehrnezhad

LSU Doctoral Dissertations

Mechanical properties of a cell reflect its biological and pathological conditions including cellular disorders and fundamental cellular processes such as cell division and differentiation. There have been active research efforts to develop high-throughput platforms to mechanically characterize single cells. Yet, many of these research efforts are focused on suspended cells and use a flow-through configuration. Therefore, adherent cells are detached prior to the characterization, which seriously perturbs the cellular conditions. Also, methods for adherent cells are limited in their throughput.

My study is aimed to fill the technical gap in the field of single cell analysis, which is a high-throughput …


Estimation And Prediction Of The Human Gait Dynamics For The Control Of An Ankle-Foot Prosthesis, Guilherme Aramizo Ribeiro Jan 2019

Estimation And Prediction Of The Human Gait Dynamics For The Control Of An Ankle-Foot Prosthesis, Guilherme Aramizo Ribeiro

Dissertations, Master's Theses and Master's Reports

With the growing population of amputees, powered prostheses can be a solution to improve the quality of life for many people. Powered ankle-foot prostheses can be made to behave similar to the lost limb via controllers that emulate the mechanical impedance of the human ankle. Therefore, the understanding of human ankle dynamics is of major significance. First, this work reports the modulation of the mechanical impedance via two mechanisms: the co-contraction of the calf muscles and a change of mean ankle torque and angle. Then, the mechanical impedance of the ankle was determined, for the first time, as a multivariable …


Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop Jan 2019

Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop

Dissertations, Master's Theses and Master's Reports

The purpose of this research is to investigate the relationship between the mechanical impedance of the human ankle and the corresponding lower extremity muscle activity. Three experimental studies were performed to measure the ankle impedance about multiple degrees of freedom (DOF), while the ankle was subjected to different loading conditions and different levels of muscle activity. The first study determined the non-loaded ankle impedance in the sagittal, frontal, and transverse anatomical planes while the ankle was suspended above the ground. The subjects actively co-contracted their agonist and antagonistic muscles to various levels, measured using electromyography (EMG). An Artificial Neural Network …


Microfluidic Electrical Impedance Spectroscopy, John J. Foley Sep 2018

Microfluidic Electrical Impedance Spectroscopy, John J. Foley

Master's Theses

The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …


Microbubble Generation By Piezoelectric Transducers For Biomedical Studies, Mohammed Alkhazal Jul 2016

Microbubble Generation By Piezoelectric Transducers For Biomedical Studies, Mohammed Alkhazal

Electrical & Computer Engineering Theses & Dissertations

Bubbles induced by blast waves or shocks are speculated as the major cause of damage in biological cells in mild traumatic brain injuries (TBI). Microbubble collapse was found to induce noticeable cell detachment from the cell substrate, changes in focal adhesion, and biomechanics. To better understand the bubble mechanism, a system needs to be constructed which allows clear differentiation on the impact of bubbles from that of shocks. Such a generator needs to be low profile in order to place under a microscope. A piezoelectric transducer system was designed to meet the need. The system uses either a flat or …


Developing A Hardware Platform For A Low-Power, Low-Cost, Size-Constrained Biomechanical Telemetry System, Aditya Balasubramanian Apr 2014

Developing A Hardware Platform For A Low-Power, Low-Cost, Size-Constrained Biomechanical Telemetry System, Aditya Balasubramanian

Open Access Theses

As sport-related traumatic brain injuries face increasing attention from the media and the general public, the need to be able to detect brain injury quickly, inexpensively and accurately is more important than ever. Commercially-available event-based systems exist that claim to achieve this goal; however, they collect little to no continuous-time data and primarily indicate when a pre-determined acceleration threshold has been exceeded under the unvalidated assumption that a potentially concussive blow has occurred. Recent findings by the Purdue Neurotrauma Group (PNG) have indicated that repeated exposure to both concussive and subconcussive blows can result in cumulative trauma disorder. To track …


An Approach To Identifying The Biomechanical Differences Between Intercostal Cartilage In Subjects With Pectus Excavatum And Normals In Vivo: Reconstruction And Ct Registration, Zhenzhen Yan Apr 2008

An Approach To Identifying The Biomechanical Differences Between Intercostal Cartilage In Subjects With Pectus Excavatum And Normals In Vivo: Reconstruction And Ct Registration, Zhenzhen Yan

Electrical & Computer Engineering Theses & Dissertations

Pectus excavatum (PE) is a congenital chest wall deformity affecting the ribs and sternum and exhibiting a concave appearance in the anterior chest wall. In this thesis, we describe a study to investigate in vivo differences in the pectus excavatum rib cage and outline steps using normals and pectus patients data in developing models and methods to be used in carrying out the study. We propose methods to develop reconstructed models in order to enable proper registration between data collection points (DCPs) on the 3D CT rib cage model and CT skin surface model and registration between CT surrogate models …