Open Access. Powered by Scholars. Published by Universities.®

Biomechanics and Biotransport Commons

Open Access. Powered by Scholars. Published by Universities.®

2012

Discipline
Institution
Keyword
Publication
Publication Type

Articles 1 - 12 of 12

Full-Text Articles in Biomechanics and Biotransport

Designing For Success: Developing Engineers Who Consider Universal Design Principles, Kimberly Edginton Bigelow Oct 2012

Designing For Success: Developing Engineers Who Consider Universal Design Principles, Kimberly Edginton Bigelow

Mechanical and Aerospace Engineering Faculty Publications

Engineers must design for a diverse group of potential users of their products; however, engineering curricula rarely include an emphasis on universal design principles. This research article details the effectiveness of a design project implemented in a first-year engineering course in an effort to raise awareness of the need for engineers to be more inclusive when designing. Students were asked to apply universal design principles to redesign an engineering laboratory to make it more usable to all, including individuals with disabilities who use the room. A representative from the university’s disability services staff, as well as individuals with first-hand experience …


The Biomechanical Role Of Scaffolds In Augmented Rotator Cuff Tendon Repairs, Amit Aurora, Jesse A. Mccarron, Antonie J. Van Den Bogert, Jorge E. Gatica, Joseph P. Iannotti, Kathleen A. Derwin Aug 2012

The Biomechanical Role Of Scaffolds In Augmented Rotator Cuff Tendon Repairs, Amit Aurora, Jesse A. Mccarron, Antonie J. Van Den Bogert, Jorge E. Gatica, Joseph P. Iannotti, Kathleen A. Derwin

Mechanical Engineering Faculty Publications

Background

Scaffolds continue to be developed and used for rotator cuff repair augmentation; however, the appropriate scaffold material properties and/or surgical application techniques for achieving optimal biomechanical performance remains unknown. The objectives of the study were to simulate a previously validated spring-network model for clinically relevant scenarios to predict: (1) the manner in which changes to components of the repair influence the biomechanical performance of the repair and (2) the percent load carried by the scaffold augmentation component.

Materials and methods

The models were parametrically varied to simulate clinically relevant scenarios, namely, changes in tendon quality, altered surgical technique(s), and …


Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel Jun 2012

Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel

Master's Theses

Experimental results show that collagen fibers exhibit stress relaxation under tension and a highly anisotropic distribution. To further develop the earlier model of Stender [1], the collagen constituent was updated to reflect its intrinsic viscoelasticity and anisotropic distribution, and integrated with an existing mixture model with glycosaminoglycans and ground substance matrix. A two-term Prony series expansion of the quasi-linear viscoelastic model was chosen to model the viscoelastic properties of the collagen fibers. Material parameters were determined by using the simplex method to minimize the sum of squared errors between model results and experimental stress relaxation data of tissue in tension. …


A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen Jun 2012

A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen

Master's Theses

A new detection reagent that could possibly augment or replace antibodies research and diagnosis methods are aptamers. Aptamers are ssDNA, RNA or polypeptide constructs that function like active antibodies. Antibodies and aptamers both specifically bind to selected target molecules, and as such they enable the detection or targeting of the presence or absence of a specific antigen.

In order to ensure that ssDNA aptamers perform similarly to antibodies, anti-VEGF-A polyclonal antibody and anti-VEGF-A ssDNA aptamer were evaluated against vascular endothelial growth factor A (VEGF-A) using Surface Plasmon Resonance (SPR). It was hypothesized that the anti-VEGF-A aptamer had the same, if …


Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham Jun 2012

Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham

Biomedical Engineering

No abstract provided.


Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio May 2012

Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio

Master's Theses

Accurate tracking of hand grip force is an important consideration needed for a robust understanding in the study of human biomechanics. One aspect where it proves useful is in hand-arm vibration, such as from gripping a power tool. Depending on how firmly the user is gripping the tool, they may change their exposure levels to the tool vibration, which can lead to potential disorders such as Hand-Arm Vibration Syndrome (HAVS).

A small, battery powered portable force unit has been developed to supply power to, and condition, the signals from eight thin-film force sensors. This gives a better understanding of the …


A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils May 2012

A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils

Master's Theses

Biomechanical risk factors are physical stressors that act on the neuromuscular structures of the human body and are present in all occupational settings. Repetition and intensity of tasks performed can magnify the effects of the biomechanical risks that a worker is exposed to.

After reviewing the current literature on ergonomics in laparoscopic surgery it was clear that a comprehensive approach to quantitatively reporting on the biomechanical risk factors associated with surgical hand tools had never been performed. Utilizing an opto-electronic motion capture system meant the exact surgeon posture was recorded during simulated surgical tasks. Electromyography was used to evaluate muscle …


Simulation Of Lower Limb Axial Arterial Length Change During Locomotion, Melissa D. Young, Matthew C. Streicher, Richard J. Beck, Antonie J. Van Den Bogert, Azita Tajaddini, Brian L. Davis May 2012

Simulation Of Lower Limb Axial Arterial Length Change During Locomotion, Melissa D. Young, Matthew C. Streicher, Richard J. Beck, Antonie J. Van Den Bogert, Azita Tajaddini, Brian L. Davis

Mechanical Engineering Faculty Publications

The effect of external forces on axial arterial wall mechanics has conventionally been regarded as secondary to hemodynamic influences. However, arteries are similar to muscles in terms of the manner in which they traverse joints, and their three-dimensional geometrical requirements for joint motion. This study considers axial arterial shortening and elongation due to motion of the lower extremity during gait, ascending stairs, and sitting-to-standing motion. Arterial length change was simulated by means of a graphics based anatomic and kinematic model of the lower extremity. This model estimated the axial shortening to be as much as 23% for the femoropopliteal arterial …


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …


Mechanical Properties Of Bone Due To Sost Expression: A 3-Point Bending Assessment Of Murine Femurs, Kainoa John Peterson May 2012

Mechanical Properties Of Bone Due To Sost Expression: A 3-Point Bending Assessment Of Murine Femurs, Kainoa John Peterson

Master's Theses

Sclerostin, a protein coded for by the SOST gene, is an osteocyte-expressed negative regulator of bone formation. The absence of SOST in the genome may have an effect on bone formation both during skeletal maturation and full maturity. This study attempts to determine significant differences in the mechanical properties of bone that expresses SOST compared to bone that does not. One hundred femur samples from 6, 8, and 12 month old mice were obtained from Lawrence Livermore National Labs and loaded until failure using three-point bending. Results showed significant differences in treatment group effects for cross sectional area, yield force, …


Electrokinetic Transport Phenomena In Nanofluidic Devices, Mingkan Zhang Apr 2012

Electrokinetic Transport Phenomena In Nanofluidic Devices, Mingkan Zhang

Mechanical & Aerospace Engineering Theses & Dissertations

Nanofluidic devices have wide potential applications in biology, chemistry and medicine, and have been proven to be very valuable in sensing biological particles (e.g., DNA and proteins) due to their efficiency, sensitivity and portability. Electrokinetic control of ion, fluid, and particle transport by using only electric field is the most popular method employed in nanofluidic devices. A comprehensive understanding of the electrokinetic ion, fluid, and particle transport in nanofluidics is essential for developing nanofluidic devices for the detection of single molecules, such as the next generation nanopore-based DNA sequencing technology. This research explored numerical simulation of electrokinetic ion and fluid …


Bisphosphonates And Bone Microdamage, William A. Caruthers Jan 2012

Bisphosphonates And Bone Microdamage, William A. Caruthers

Theses and Dissertations--Biomedical Engineering

Osteoporosis is a significant healthcare issue due to the increasing elderly population. Bisphosphonates are used to treat osteoporosis by reducing the rate of resorption, increasing bone mineral density (BMD) and thereby reducing fracture risk. Long-term bisphosphonate treatment, however, has been associated with low-energy fractures. Bone microdamage may provide a partial explanation for one of the mechanisms responsible for these fractures since it has been shown to reduce bone toughness, fracture resistance, and bone strength. The goal of this study was to quantify the changes in bone microdamage parameters with the duration of bisphosphonate treatment. This study selected, stained, and histomorphometrically …