Open Access. Powered by Scholars. Published by Universities.®
Biomechanics and Biotransport Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- University of Kentucky (4)
- Kennesaw State University (3)
- Old Dominion University (2)
- City University of New York (CUNY) (1)
- Clemson University (1)
-
- Duquesne University (1)
- Institut de Recherche Robert-Sauvé en santé et en sécurité du travail (1)
- Marshall University (1)
- The University of Southern Mississippi (1)
- University of Arkansas, Fayetteville (1)
- University of Nebraska Medical Center (1)
- University of Nebraska at Omaha (1)
- University of Nevada, Las Vegas (1)
- University of North Florida (1)
- University of South Carolina (1)
- Western University (1)
- Keyword
-
- Biomechanics (3)
- Rehabilitation (3)
- Walking (3)
- Electromyography (2)
- Gait (2)
-
- Low Back Pain (2)
- 3D Stem Cell Culture (1)
- 3D-Printing (1)
- <p>Three-dimensional imaging in medicine.</p> <p>Photogrammetry.</p> <p>Biomechanics.</p> <p>Kinesiology.</p> <p>Physics and applied physics.</p> (1)
- Academic -- UNF -- Engineering; developmental; disability; falls; mobility; pediatrics; rehabilitation (1)
- Academic -- UNF -- Master of Science in Mechanical Engineering; Dissertations (1)
- Active (1)
- Air-jetting Bioprinting (1)
- Alginate (1)
- Amputation (1)
- Amputees (1)
- Anterior Cruciate Ligament (1)
- Articulation (1)
- Artificial feet (1)
- Automated prostheses (1)
- Bio-Feedback (1)
- Biology (1)
- Body mechanics (1)
- Bone (1)
- Cell Encapsulation (1)
- Coaxial Air Channel (1)
- Colonne vertébrale (1)
- Coupled Motion (1)
- Direct linear transformation (1)
- Droplet based Bioprinting (1)
- Publication Year
- Publication
-
- Faculty Articles (3)
- All Theses (1)
- Electronic Theses and Dissertations (1)
- Graduate Theses and Dissertations (1)
- Human Movement Studies & Special Education Faculty Publications (1)
-
- Master's Theses (1)
- Mechanical and Materials Engineering Publications (1)
- Publications and Research (1)
- Rehabilitation Sciences Theses & Dissertations (1)
- Senior Theses (1)
- Theses & Dissertations (1)
- Theses and Dissertations--Biomedical Engineering (1)
- Theses and Dissertations--Kinesiology and Health Promotion (1)
- Theses and Dissertations--Mechanical and Aerospace Engineering (1)
- Theses and Dissertations--Rehabilitation Sciences (1)
- Theses, Dissertations and Capstones (1)
- UNF Graduate Theses and Dissertations (1)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (1)
- UNO Student Research and Creative Activity Fair (1)
- Études primaires (1)
- Publication Type
Articles 1 - 22 of 22
Full-Text Articles in Biomechanics and Biotransport
Effects Of A Passive Assistive Hamstring Device On Overground Running Kinematics And Hamstring Activation., Quinn Castner
Effects Of A Passive Assistive Hamstring Device On Overground Running Kinematics And Hamstring Activation., Quinn Castner
All Theses
Hamstring strain injuries are among the most common and recurring injuries in sports, occurring most often during the terminal swing phase of gait. Despite progress in rehabilitation, the incidence of injury has only increased, suggesting a need for a novel intervention. We designed a passive, assistive, wearable device with two specific criteria in mind: to offload the hamstrings during running, and do so without hindering normal kinematic patterns. The device consists of an adjustable elastic band anchored proximally at the waist and distally just above the ankle joint center. It stretches and shortens with the hamstrings, providing passive hip extension …
Electromyography, Prosthetic Properties, And Running Biomechanics In Recreationally Active Persons With Lower Extremity Amputation, Paige M. Agnew
Electromyography, Prosthetic Properties, And Running Biomechanics In Recreationally Active Persons With Lower Extremity Amputation, Paige M. Agnew
Rehabilitation Sciences Theses & Dissertations
Lower extremity loss affects nearly 150,000 individuals in the United States yearly yielding extreme health care costs annually. Typically, prosthetic devices are prescribed for 5-8 years despite known changes to an individual’s gait as time progresses. Patients can expect to undergo approximately 8-12 weeks of gait retraining to improve their comfort and efficiency. Biomechanical changes occur when running with a specific running prosthetic including considerable biomechanical and neuromuscular interlimb asymmetries and alterations in loading patterns. The purpose of this dissertation was to investigate the biomechanical demands for lower extremity prosthesis users during running. The first study synthesized peer reviewed evidence …
Advances In Bone And Orthopedics 2024 Edition, Jean-Philippe Berteau, Laurent Pujo-Menjouet
Advances In Bone And Orthopedics 2024 Edition, Jean-Philippe Berteau, Laurent Pujo-Menjouet
Publications and Research
We are delighted to present the latest edition of ”Advances in Bone and Orthopedics,” a comprehensive compilation of pioneering research and innovative developments in the field. This volume brings together a selection of peer-reviewed abstracts from BONITOS 2024, the Fourth Season of the Bone and Orthopedics Interdisciplinary Symposium, held on May 31st, 2024, at the College of Staten Island in New York. This symposium, a hallmark event in the calendar of professionals dedicated to bone health and orthopedic excellence. The contributions within this volume reflect the breadth and depth of research presented at BONITOS 2024. These abstracts represent cutting-edge studies …
A 3d Dlt View Correction Tool For Manual Digitizing: A Cross-Platform Application For Correcting Shifted Image Coordinates Prior To Object Coordinate Reconstruction, William Moynihan
Theses, Dissertations and Capstones
While 3D direct linear transformation is a versatile motion capture method, care must be taken so that the cameras are not bumped or adjusted between the object space calibration phase and the end of video recording. Disturbing the cameras during this time will misalign the view, making the movement data invalid for the associated calibration. The purpose of this study was to design and validate a cross-platform software application for transforming image coordinates from a bumped camera to be compatible with the object space calibration and to determine the relationship between reconstruction error and changes to bumped camera views.
For …
Air-Jet Bioprinting Of Stem Cell-Encapsulated Alginate Micro-Droplets For Organoid Biomanufacturing, Mirabella B. Stump
Air-Jet Bioprinting Of Stem Cell-Encapsulated Alginate Micro-Droplets For Organoid Biomanufacturing, Mirabella B. Stump
Electronic Theses and Dissertations
Biomanufactured 3D-organoids show promise for modeling and treating various conditions, particularly insulin-dependent diabetes mellitus (type-1 diabetes). Pancreatic islet organoids serve as sustainable sources of insulin-producing β-cells, potentially restoring insulin regulation in patients and providing a long-term solution for diabetes. Hydrogel droplet printing is an emerging technique in regenerative medicine due to its advantageous tunability and biocompatibility; however, challenges of consistency, quality control, and scalability persist. To address these issues, we developed a novel air-jetting based droplet bioprinting system for the generation of monodispersed alginate micro-droplets. The objective of this project was to incorporate human induced pluripotent stem cells (hiPSCs) into …
A Proof Of Concept For Detection Of Palato-Lingual Contact Without Intraoral Electrodes In A Human Participant, Amitava Biswas
A Proof Of Concept For Detection Of Palato-Lingual Contact Without Intraoral Electrodes In A Human Participant, Amitava Biswas
Master's Theses
The author of this thesis conceived and investigated an unexpected electrical signal that may not be noticed during regular electroglottography (EGG) when electrodes are conventionally placed on the anterior surface of the throat. It appears that there is a measurable electrical signal from the EGG equipment when electrodes are placed over the frontal cheek (belly of zygomatic muscle), and the tongue is elevated to contact the hard palate, or the tongue is lowered to break the contact. Therefore, this phenomenon is designated as unconventional electroglottography (UEGG, Dr. Steven Cloud, private communication, July 17, 2022).
Two distinctive patterns of waveforms were …
Is The Walking Pattern Similar Between Slope Walking And Obstacle Negotiation?, Jiani Lu
Is The Walking Pattern Similar Between Slope Walking And Obstacle Negotiation?, Jiani Lu
Theses & Dissertations
Studying biomechanical characteristics of human motion sheds light on the motor control strategies in the central nervous system. Slope walking and obstacle negotiation appear to have some similarities in control strategies based on subjective observation, but these two motions have never been compared objectively in biomechanics literature. This study aimed to investigate the similarities between obstacle negotiation and slope walking in kinematics and muscle activity. The similarities were determined by the correlation of the maximum heel elevation and muscle co-activation index between obstacle negotiation and inclined treadmill walking. The strength of correlation was compared in four different pairs of conditions: …
The Effect Of Walking Speed And Magnitude Of Perturbation On Compensatory Responses, Farahnaz Fallah Tafti, Jenna Yentes
The Effect Of Walking Speed And Magnitude Of Perturbation On Compensatory Responses, Farahnaz Fallah Tafti, Jenna Yentes
UNO Student Research and Creative Activity Fair
Imposing a perturbation can induce an unstable condition during gait. Measuring the compensatory responses may be an accurate indicator of the ability to control stability. Responses to a perturbation can be quantified through the perturbed walking pattern deviations from an unperturbed condition. The aim of this study was to determine the effect of perturbation magnitude or speed of walking on compensatory responses to lateral perturbations during walking. Twenty healthy young participants recruited to this study and they were perturbed with the medium magnitude of perturbation, while walking on the treadmill at three different speeds (slow, preferred, and fast). They also …
Safety Analysis Of Battery-Powered Adaptive Ride-On Toys For Children With Disabilities, Abbey Fraser
Safety Analysis Of Battery-Powered Adaptive Ride-On Toys For Children With Disabilities, Abbey Fraser
UNF Graduate Theses and Dissertations
Modified battery-powered ride-on toy cars, or adaptive ride-on toys, represent novel rehabilitation tools and developmental aids for children with disabilities. Studies have shown that children are benefiting socially and developmentally from their use. However, the use of these toys by children with disabilities potentially poses a risk of injury and it is vitally important to ensure the safe use of these toys, particularly for the benefit of those with developmental challenges.
Within this context, the purpose of the first study was to determine whether modifications to ride-on toys are sufficient to prevent common modes of injury such as falls, passenger …
Walking Kinematics In Young Children With Limb Loss Using Early Versus Traditional Prosthetic Knee Prescription Protocols, Mark Daniel Geil, Zahra Safaeepour, Brian Giavedoni, Colleen Coulter
Walking Kinematics In Young Children With Limb Loss Using Early Versus Traditional Prosthetic Knee Prescription Protocols, Mark Daniel Geil, Zahra Safaeepour, Brian Giavedoni, Colleen Coulter
Faculty Articles
The traditional treatment protocol for young children with congenital or acquired amputations at or proximal to the knee prescribes a prosthesis without a working knee joint, based in part on the assumption that a child learning to walk cannot properly utilize a passively flexing prosthetic knee component. An alternative to this Traditional Knee (TK) protocol is an “Early Knee” (EK) protocol, which prescribes an articulating prosthetic knee in the child’s first prosthesis, during development of crawling and transitioning into and out of upright positions. To date, no study has compared samples of children with limb loss at or proximal to …
Knee Joint Loading Following Anterior Cruciate Ligament Reconstruction: Link To Patient Reported Outcomes And A Novel Method To Monitor With Wearable Sensors, Alex Spencer
Theses and Dissertations--Kinesiology and Health Promotion
Recovery from anterior cruciate ligament reconstruction (ACLR) commonly results in undesirable physical and patient-reported outcomes (PROs). Identification of modifiable factors such as knee contact force (KCF) early in rehabilitation that can improve these outcomes is important due to the rapid decrease in function, quality of life, and joint health in this population. Additionally, if noninvasive measurement of KCFs outside of a traditional laboratory were possible, clinicians could optimize patient treatment with personalized care. Therefore, there are two primary aims to this thesis: 1) quantify the link between KCF and PROs which measure pain, ability to perform activities of daily living, …
Volumetric Muscle Loss: The Role Of Physical Activity And Autologous Repair On Force Recovery And Signaling Pathways, Richard Perry
Volumetric Muscle Loss: The Role Of Physical Activity And Autologous Repair On Force Recovery And Signaling Pathways, Richard Perry
Graduate Theses and Dissertations
Volumetric muscle loss affects both military and civilian persons. The hallmark of this injury is incomplete muscle regeneration, excessive fibrosis, and chronic inflammatory signaling resulting in permanent functional loss. Since permanent functional loss drastically reduces quality of life, many studies have been conducted to improve force recovery. Current scientific literature considers a repair strategy of either devitalized scaffolds infused with growth factors or viable tissue plus activating factors to be the more promising interventions for optimal force recovery. PURPOSE The purpose of this study is to incorporate autologous repair and physical activity and observe the effects of muscle force recovery …
Hard, Soft And Off-The-Shelf Foot Orthoses And Their Effect On The Angle Of The Medial Longitudinal Arch: A Biplane Fluoroscopy Study, Megan E.R. Balsdon, Colin E. Dombroski, Kristen Bushey, Thomas Jenkyn
Hard, Soft And Off-The-Shelf Foot Orthoses And Their Effect On The Angle Of The Medial Longitudinal Arch: A Biplane Fluoroscopy Study, Megan E.R. Balsdon, Colin E. Dombroski, Kristen Bushey, Thomas Jenkyn
Mechanical and Materials Engineering Publications
Background: Foot orthoses have proven to be effective for conservative management of various pathologies. Pathologies of the lower limb can be caused by abnormal biomechanics such as abnormal foot structure and alignment, leading to inadequate support. Objectives: To compare biomechanical effects of different foot orthoses on the medial longitudinal arch (MLA) during dynamic gait using skeletal kinematics. Study Design: Prospective, cross-sectional study design. Methods: The MLA angle was measured for 12 participants among three groups: pes planus, pes cavus and normal arch. Five conditions were compared: three orthotic devices (hard custom foot orthosis (CFO), soft CFO, and off-the-shelf Barefoot Science©), …
Connecting The Pieces: How Low Back Pain Alters Lower Extremity Biomechanics And Shock Attenuation In Active Individuals, Alexa Johnson
Connecting The Pieces: How Low Back Pain Alters Lower Extremity Biomechanics And Shock Attenuation In Active Individuals, Alexa Johnson
Theses and Dissertations--Rehabilitation Sciences
Low back pain in collegiate athletes has been reported at a rate of 37% from a wide array of sports including soccer, volleyball, football, swimming, and baseball. Whereas, in a military population the prevalence of low back pain is 70% higher than the general population. Compensatory movement strategies are often used as an attempt to reduce pain. Though compensatory movement strategies may effectively reduce pain, they are often associated with altered lower extremity loading patterns. Those who suffer from chronic low back pain tend to walk and run slower and with less trunk and pelvis coordination and variability. Individuals with …
Walking Biomechanics And Energetics Of Individuals With A Visual Impairment: A Preliminary Report, Hunter J. Bennett, Kevin A. Valenzuela, Kristina Fleenor, Steven Morrison, Justin A. Haegele
Walking Biomechanics And Energetics Of Individuals With A Visual Impairment: A Preliminary Report, Hunter J. Bennett, Kevin A. Valenzuela, Kristina Fleenor, Steven Morrison, Justin A. Haegele
Human Movement Studies & Special Education Faculty Publications
Purpose.
Although walking gait in sighted populations is well researched, few studies have investigated persons with visual impairments (VIs). Given the lack of physical activity in people with VIs, it is possible that reduced efficiency in walking could adversely affect activity. The purposes of this preliminary study were to (1) examine the biomechanics and energetics utilized during independent and guided walking in subjects with VIs, and (2) compare gait biomechanics between people with VIs and sighted controls.
Methods.
Three-dimensional motion capture and force platforms were used during independent and guided walking at self-selected speeds. Joint angles, moments, external work, and …
Integration Of A Sensory Driven Model For Hand Grasp Function In 3d Printed Prostheses, Austin T. Hetherington
Integration Of A Sensory Driven Model For Hand Grasp Function In 3d Printed Prostheses, Austin T. Hetherington
Senior Theses
My Honors Thesis was completed through the Biomedical Engineering senior design project I worked on. Our project took a mechanically operated 3D printed prosthetic hand and automated the process by which it makes a grasp. The purpose of this project was to provide an affordable, automatic prosthetic hand to those either capable and incapable of wrist flexion. The current 3D printed prosthetic models require users to bend their wrist to initiate a simple grasp. However, our design took an alternative approach by using an EMG sensor placed on the ventral side of the forearm to record muscle activity, which, upon …
Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson
Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson
Theses and Dissertations--Mechanical and Aerospace Engineering
This thesis proposes an algorithm that determine the geometry of 3D-printed, custom-designed spring element bands made of thermoplastic elastomer (TPE) for use in a wearable orthotic device to aid in the physical therapy of a human hand exhibiting spasticity after stroke. Each finger of the hand is modeled as a mechanical system consisting of a triple-rod pendulum with nonlinear stiffness at each joint and forces applied at the attachment point of each flexor muscle. The system is assumed quasi-static, which leads to a torque balance between the flexor tendons in the hand, joint stiffness and the design force applied to …
Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian
Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian
Theses and Dissertations--Biomedical Engineering
Management and control of the low back pain as an important health problem in the industrial societies necessitates to investigate how the risk of this disease is affected by aging. Since the abnormalities of the lumbopelvic kinematics are related to the existence or risk of low back injuries, the objective of this dissertation was set to find the age-related differences in lumbopelvic kinematics when performing basic trunk motions reaching to range of motion in different anatomical planes.
A cross-sectional study was designed where sixty asymptomatic individuals between 20–70 years old with no confounding health condition, no current or previous highly …
The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink
The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink
UNLV Theses, Dissertations, Professional Papers, and Capstones
Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …
Custom-Molded Foot-Orthosis Intervention And Multisegment Medial Foot Kinematics During Walking, Mark Geil
Custom-Molded Foot-Orthosis Intervention And Multisegment Medial Foot Kinematics During Walking, Mark Geil
Faculty Articles
No abstract provided.
Trunk Response Analysis Under Sudden Forward Perturbations Using A Kinematics-Driven Model, B. Bazrgari, A. Shirazi-Adl, Christian Larivière
Trunk Response Analysis Under Sudden Forward Perturbations Using A Kinematics-Driven Model, B. Bazrgari, A. Shirazi-Adl, Christian Larivière
Études primaires
No abstract provided.
Energy Loss And Stiffness Properties Of Dynamic Elastic Response Prosthetic Feet, Mark Geil
Energy Loss And Stiffness Properties Of Dynamic Elastic Response Prosthetic Feet, Mark Geil
Faculty Articles
No abstract provided.