Open Access. Powered by Scholars. Published by Universities.®
Biomechanics and Biotransport Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (4)
- Anatomy (3)
- Musculoskeletal System (3)
- Biomechanical Engineering (2)
- Mechanical Engineering (2)
-
- Medical Specialties (2)
- Orthopedics (2)
- Physical Sciences and Mathematics (2)
- Aerodynamics and Fluid Mechanics (1)
- Aerospace Engineering (1)
- Applied Mathematics (1)
- Chemical Engineering (1)
- Computational Engineering (1)
- Computer Sciences (1)
- Exercise Physiology (1)
- Fluid Dynamics (1)
- Life Sciences (1)
- Numerical Analysis and Computation (1)
- Numerical Analysis and Scientific Computing (1)
- Other Pharmacy and Pharmaceutical Sciences (1)
- Partial Differential Equations (1)
- Pharmacy and Pharmaceutical Sciences (1)
- Physics (1)
- Physiology (1)
- Space Habitation and Life Support (1)
- Transport Phenomena (1)
- Keyword
- Publication
- Publication Type
Articles 1 - 5 of 5
Full-Text Articles in Biomechanics and Biotransport
Interactive Effects Of Tissue Temperature And Hydration State On Tendon Mechanical Properties Using A Chicken Drumstick Model, Makayla Maso, Kiara Maso, Mikayla Hulvey
Interactive Effects Of Tissue Temperature And Hydration State On Tendon Mechanical Properties Using A Chicken Drumstick Model, Makayla Maso, Kiara Maso, Mikayla Hulvey
Discovery Day - Daytona Beach
This study focused on the effects of temperature and hydration on tendon extensibility. Four experimental groups were tested using chicken leg tendons tested ex vivo: cold and dehydrated, cold and hydrated, warm and dehydrated, and warm and hydrated. Each treatment group was pulled with an increasing load and measured. It was hypothesized that the warm and hydrated test group would extend the furthest. This was based on studies citing increased bodily flexibility with increasing body temperature as well as stiffness at lower temperatures. Combining temperature and hydration state allowed for not only individual effects of variables to be tested but …
Numerical Study Of Nutrient Mixing In Trabecular Bone In Microgravity, Disuse And Normogravity, Sagar Gharti
Numerical Study Of Nutrient Mixing In Trabecular Bone In Microgravity, Disuse And Normogravity, Sagar Gharti
Doctoral Dissertations and Master's Theses
Mechanical loading is known to regulate bone remodeling by driving interstitial fluid flow which stimulates cells and drives nutrient transport within the trabecular network. In microgravity, the absence of mechanical stimulation or loading suppresses convective flow processes, causing diffusion-driven nutrient mixing and renewal, and accelerated bone loss. This thesis investigates how oscillation frequency and trabecular bone density jointly control nutrient mixing and wall shear stress within trabecular cavities.
A computational fluid dynamics (CFD) framework is developed in STAR-CCM+ using a soft-cap oscillation model that mimics cyclic compression. Three idealized trabecular morphologies are simulated across different frequencies to represent microgravity or …
Combination Of Statistical Shape Modeling And Statistical Parametric Mapping To Quantify Cartilage Contact Mechanics In Hip Dysplasia, Penny R. Atkins Phd, Shireen Y. Elhabian Phd, Jeffrey A. Weiss Phd, Ross T. Whitaker Phd, Christopher L. Peters Md, Andrew E. Anderson Phd
Combination Of Statistical Shape Modeling And Statistical Parametric Mapping To Quantify Cartilage Contact Mechanics In Hip Dysplasia, Penny R. Atkins Phd, Shireen Y. Elhabian Phd, Jeffrey A. Weiss Phd, Ross T. Whitaker Phd, Christopher L. Peters Md, Andrew E. Anderson Phd
PanaSoMM
Finite element models can predict subject-specific chondrolabral stresses and help to elucidate the effect of under-coverage and incongruency of the hip joint in patients with dysplasia. However, complex stress patterns are difficult to generalize and evaluate statistically. With an established correspondence across shapes from statistical shape modeling (SSM), statistical parametric mapping (SPM) allows for evaluation of local variability while preserving model subject-specificity. Herein, we evaluated the combined application of SSM and SPM to compare cartilage contact stress between control subjects and patients with dysplasia.
Previously published hip joint contact stresses were mapped onto chondrolabral surface meshes and incorporated into an …
Application Of Statistical Shape Modeling To Predict Clinical Metric Of Femoral Head Coverage In Patients With Developmental Dysplasia, Penny R. Atkins Phd, Praful Agrawal Phd, Joseph D. Mozingo Phd, Keisuke Uemura Md, Phd, Kunihiko Tokunaga Md, Christopher L. Peters Md, Shireen Y. Elhabian Phd, Ross T. Whitaker Phd, Andrew E. Anderson Phd
Application Of Statistical Shape Modeling To Predict Clinical Metric Of Femoral Head Coverage In Patients With Developmental Dysplasia, Penny R. Atkins Phd, Praful Agrawal Phd, Joseph D. Mozingo Phd, Keisuke Uemura Md, Phd, Kunihiko Tokunaga Md, Christopher L. Peters Md, Shireen Y. Elhabian Phd, Ross T. Whitaker Phd, Andrew E. Anderson Phd
PanaSoMM
Developmental dysplasia of the hip (DDH) is described as under-coverage of the femoral head by the acetabulum, resulting in mechanical instability. Though DDH is often diagnosed using plain film radiographs, these images cannot adequately capture 3D joint coverage. Herein, we applied a 3D statistical shape model (SSM) to the femur and hemi-pelvis of patients with DDH to objectively measure shape variation and evaluated whether SSM outputs could predict measurements of joint coverage.
The femur and hemi-pelvis were semi-automatically segmented from CT images (83 hips from 47 females with DDH). Surfaces of each hip were reconstructed from segmentations, aligned, and input …
A Meshless Approach To Computational Pharmacokinetics, Anthony Matthew Khoury
A Meshless Approach To Computational Pharmacokinetics, Anthony Matthew Khoury
Doctoral Dissertations and Master's Theses
The meshless method is an incredibly powerful technique for solving a variety of problems with unparalleled accuracy and efficiency. The pharmacokinetic problem of transdermal drug delivery (TDDD) is one such topic and is of significant complexity. The locally collocated meshless method (LCMM) is developed in solution to this topic. First, the meshless method is formulated to model this transport phenomenon and is then validated against an analytical solution of a pharmacokinetic problem set, to demonstrate this accuracy and efficiency. The analytical solution provides a locus by which convergence behavior are evaluated, demonstrating the super convergence of the locally collocated meshless …