Open Access. Powered by Scholars. Published by Universities.®
Biomechanics and Biotransport Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Publication
- Publication Type
Articles 1 - 6 of 6
Full-Text Articles in Biomechanics and Biotransport
Hip And Knee Biomechanics For Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov
Hip And Knee Biomechanics For Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov
Master's Theses
Transtibial amputees are at increased risk of contralateral hip and knee joint osteoarthritis, likely due to abnormal biomechanics. Biomechanical challenges exist for transtibial amputees in gait and cycling; particularly, asymmetry in ground/pedal reaction forces and joint kinetics is well documented and state-of-the-art passive and powered prostheses do not fully restore natural biomechanics. Elliptical training has not been studied as a potential exercise for rehabilitation, nor have any studies been published that compare joint kinematics and kinetics and ground/pedal reaction forces for the same group of transtibial amputees in gait, cycling, and elliptical training. The hypothesis was that hip and knee …
Effects Of Stride Length On Lower Limb Stiffness When Running With Body Borne Load, Nick Lobb
Effects Of Stride Length On Lower Limb Stiffness When Running With Body Borne Load, Nick Lobb
Boise State University Theses and Dissertations
Introduction: During military activities, soldiers are often required to run at a fixed cadence with body borne load, but these loads purportedly increase leg stiffness, leading to increased risk of musculoskeletal injury. Yet, to date, it is unknown how altering stride length when running with body borne load affects lower limb stiffness for males and females. Purpose: To quantify leg stiffness, and lower limb joint (hip, knee and ankle) stiffness for males and females using different stride lengths to run with body borne loads of 20 kg, 25 kg, 30 kg, and 35 kg. Methods: Twenty-seven (17 males and 10 …
Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood
Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood
STAR Program Research Presentations
Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …
Finite Element Analysis And Validation Of Hip Joints With The Main Types Of Femoroacetabular Impingement, Kevin Lucas Mitchell
Finite Element Analysis And Validation Of Hip Joints With The Main Types Of Femoroacetabular Impingement, Kevin Lucas Mitchell
Master's Theses
Current research suggests that femoroacetabular impingement can be a cause of osteoarthritis. Femoroacetabular impingement is a condition that can affect both the femur and the pelvis of an individual. Femoroacetabular impingement can cause damage to the hip joint and its surrounding tissues. The articular cartilage and the labrum are both affected by this condition. A cam impingement is where a bony protrusion develops at the femoral head/neck junction. A pincer impingement is where a bony protrusion develops at the acetabular rim. Often, patients are seen with a combination of both impingements. The main goal of this study was to computationally …
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Master's Theses
With more young adults requiring total hip
arthroplasties the need for bone saving implants becomes
more important. The Zimmer Fitmore is a new bone saving
implant that utilizes an implantation technique that
reduces the damage to the muscle tissue allowing for
patients to have a short recovery time as well as a new
design that allows it to rest on the medial cortex. There
has been anecdotal evidence that this device leads to early
revision within six months of implantation due to failures
occurring in the medial cortex. The main goal of this
study was to computationally model the Zimmer …
Investigation Of Pmma Cement Penetration In Prepared Femoral Heads With A Longitudinal Slot For Hip Resurfacing Arthroplasty, Scott Snyder
Investigation Of Pmma Cement Penetration In Prepared Femoral Heads With A Longitudinal Slot For Hip Resurfacing Arthroplasty, Scott Snyder
Biomedical Engineering
Hip resurfacing arthroplasty is becoming increasingly popular in younger, active patients due to its preservation of natural biomechanics. Failure of these implants can be very traumatic and potentially life threatening. The role of cement penetration in early implant failure is not yet known, and must be investigated. This study specifically investigates the effects of a 5mm by 5mm longitudinal channel on cement penetration into the femoral head. High-density open-cell reticulated vitreous carbon foam cylinders and Huntsman Pro-cast® 20 implants based on the Birmingham Hip Resurfacing implant were used. It was determined cement penetration was increased in the area immediately surrounding …