3d Printable And Computational Models Of The Bone Marrow Mechanical Environment, Alexander Regner May 2021

3d Printable And Computational Models Of The Bone Marrow Mechanical Environment, Alexander Regner

Boise State University Theses and Dissertations

Aged individuals and astronauts experience bone loss despite rigorous physical activity. Bone mechanoresponse is in part regulated by mesenchymal stem cells (MSCs). We reported that daily low intensity vibration (LIV) restores MSC proliferation in senescence and simulated microgravity models, suggesting reduced mechanical signal delivery to MSCs likely contributes to declining bone mechanoresponse. To this end, we have developed a 3D bone marrow analog which controls trabecular geometry, marrow mechanics and external stimuli.

Finite element (FE) models of hydrogels, representing bone marrow, were generated using instantaneous compression (1000% strain/s, 20% strain) and relaxation experiments (100s) of both gelatin and hyaluronin-based hydrogels. …


The Effect Of Implant Conformity On Muscle Force Requirements In The Implanted Knee, Grace Mcconnochie Aug 2019

The Effect Of Implant Conformity On Muscle Force Requirements In The Implanted Knee, Grace Mcconnochie

Boise State University Theses and Dissertations

Implant geometry is a significant factor in determining knee stability and patient satisfaction following total knee replacement (TKR). Ineffective muscle recruitment, impaired joint functionality and increased implant wear are consequences of an unstable knee replacement. Current knee laxity evaluation techniques are limited in their ability to account for the muscular response to knee instability. This study utilizes a subject specific lower-body musculoskeletal finite element (FE) model with dynamic muscle loading to evaluate implant laxity during activities of daily living. The effect of varying implant conformity on the muscle forces required to maintain a target kinematic profile during simulated laxity testing …


Specimen-Specific Natural, Pathological, And Implanted Knee Mechanics Using Finite Element Modeling, Azhar Akber Ali Jan 2017

Specimen-Specific Natural, Pathological, And Implanted Knee Mechanics Using Finite Element Modeling, Azhar Akber Ali

Electronic Theses and Dissertations

There is an increasing incidence of knee pain and injury among the population, and increasing demand for higher knee function in total knee replacement designs. As a result, clinicians and implant manufacturers are interested in improving patient outcomes, and evaluation of knee mechanics is essential for better diagnosis and repair of knee pathologies. Common knee pathologies include osteoarthritis (degradation of the articulating surfaces), patellofemoral pain, and cruciate ligament injury and/or rupture. The complex behavior of knee motion presents unique challenges in the diagnosis of knee pathology and restoration of healthy knee function. Quantifying knee mechanics is essential for developing successful …


Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla Jun 2015

Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla

Master's Theses

Osteoarthritis (OA) is a degenerative condition of articular cartilage that affects more than 25 million people in the US. Joint injuries, like anterior cruciate ligament (ACL) tears, can lead to OA due to a change in articular cartilage loading. Gait analysis combined with knee joint finite element modeling (FEM) has been used to predict the articular cartilage loading. To predict the change of articular cartilage loading during gait due to various ACL injuries, a tibiofemoral FEM was developed from magnetic resonance images (MRIs) of a 33 year male, with no prior history of knee injuries. The FEM was validated for …


Du02, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd Jan 2015

Du02, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd

Natural Knee Data

No abstract provided.


Du06, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd Jan 2015

Du06, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd

Natural Knee Data

No abstract provided.


Du05, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd Jan 2015

Du05, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd

Natural Knee Data

No abstract provided.


Du04, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd Jan 2015

Du04, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd

Natural Knee Data

No abstract provided.


Du03, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd Jan 2015

Du03, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd

Natural Knee Data

No abstract provided.


Du01, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd Jan 2015

Du01, Center For Orthopaedic Biomechanics, Michael D. Harris, Phd, Kevin Shelburne, Phd

Natural Knee Data

No abstract provided.


Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood Aug 2013

Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood

STAR Program Research Presentations

Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …


Finite Element Analysis Of The Effect Of Low-Speed Rear End Collisions On The Medial Meniscus, Daniel J. Tichon May 2011

Finite Element Analysis Of The Effect Of Low-Speed Rear End Collisions On The Medial Meniscus, Daniel J. Tichon

Master's Theses

Low-speed, rear end vehicle collisions can inflict soft tissue damage to the passenger’s knees, especially the medial meniscus, which has been previously unexplained in published literature.  It is difficult to determine if factors such as age or other injury was the primary cause of the injury or if the accident acutely caused the meniscal tear.  Rear end collisions may produce a combination of compressive loading and torque about the knee that will injure the medial meniscus during the initial impact and the rebound phase.  The purpose of this study is to determine if it is possible for rear end low-speed …