Open Access. Powered by Scholars. Published by Universities.®

Prosthodontics and Prosthodontology Commons™

Open Access. Powered by Scholars. Published by Universities.®

Discipline
Institution
Keyword
Publication Year
Publication
Publication Type

Articles 271 - 300 of 425

Full-Text Articles in Prosthodontics and Prosthodontology

Microhardness Of Light- And Dual-Cured Resin Cements After Light Curing Through Various Translucencies Of Translucent Monolithic Zirconia, Sawanya Pechteewang Jan 2019

Microhardness Of Light- And Dual-Cured Resin Cements After Light Curing Through Various Translucencies Of Translucent Monolithic Zirconia, Sawanya Pechteewang

Chulalongkorn University Theses and Dissertations (Chula ETD)

Purpose: This study aims to investigate the microhardness of light- and dual-cured resin cements under various translucencies of monolithic zirconia specimen; translucent (T), super translucent (ST), high translucent (HT), and extra translucent (XT). Materials and Methods: Four different translucencies of zirconia specimen were prepared in the square shape, size 10×10×1 mm. The light-cured resin cement (Variolink® N LC) and the dual-cured (RelyX™ U200) resin cement were mixed and loaded in a 2-mm height and 5-mm diameter of space in a customized mold and cured through the zirconia specimens and 1-mm thick glass slide in a control group, using the light …


Color Stability, Nanohardness And Elastic Modulus Of Denture Base Acrylic Resins With Various Polymerization Techniques, Sawita Losuphakarn Jan 2019

Color Stability, Nanohardness And Elastic Modulus Of Denture Base Acrylic Resins With Various Polymerization Techniques, Sawita Losuphakarn

Chulalongkorn University Theses and Dissertations (Chula ETD)

The objective of this study was to evaluate color stability, nanohardness and elastic modulus of denture base acrylic resins with various polymerization techniques after storing in coffee, distilled water or dark chamber. Ninety disc-shaped (9X2 mm) specimens of heat-cured (TRX), microwave-cured (BTC) and light-cured (TRD) were fabricated, and randomly divided in three conditions (n=10). The color difference (DE*) was measured using a spectrophotometer at 1, 7, 28 and 56 days; The nanohardness and the elastic modulus were measured from three randomly selected of each group at day 1 and day 56 after color measurement. The repeated mixed analysis of variance …


The Clinical Study Of Wear Between Antagonist Enamel And Polished/Annealed Monolithic Zirconia Crown On Dental Implant After 6-Month Delivery, Supatsorn Benjaniratisai Jan 2019

The Clinical Study Of Wear Between Antagonist Enamel And Polished/Annealed Monolithic Zirconia Crown On Dental Implant After 6-Month Delivery, Supatsorn Benjaniratisai

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study aimed to examine the opposing natural tooth wear between polished and annealed monolithic zirconia crownon the dental implantafter 6-month delivery. Seven patients who needed the dental implant treatment were randomized to receive monolithic zirconia crowns (VITA YZ HTWhite, VITA Zahnfabrik, Germany). Total 10 zirconia crowns in 7 patients were included in this study. The samples of zirconia crown were categorized into two groups based on occlusal surface modifications of the zirconia crowns before delivery, including: Polished (Po) and Annealed (An). Each group contained 5 samples of zirconia crowns limited to either molar and premolar restorations. Control teeth were …


Effect Of Different Silane Coupling Agents On The Wettability And Shear Bond Strength Between Glass Ceramic And Resin Cement, Tanapon Tarateeraseth Jan 2019

Effect Of Different Silane Coupling Agents On The Wettability And Shear Bond Strength Between Glass Ceramic And Resin Cement, Tanapon Tarateeraseth

Chulalongkorn University Theses and Dissertations (Chula ETD)

Silane coupling agents are synthetic hybrid inorganic-organic compounds that act as adhesion promoters which chemically unify dissimilar materials. Nowadays, many brands of silane coupling agent are commercially available in the market. Each brand formulate differently from one another providing the dentists various options to choose from. The aims of this study was to investigate the effect of treating the lithium disilicate glass ceramic surface with various types of silane coupling agents in term of bonding capability and wettability. The experiment was divided into two parts. The first part of the research was to evaluate the effect of various type of …


Gene Expression Analysis Of Mmp12 And S100a4 Of Grafted Bone Using Allograft And Xenograft In Mice, Tipaporn Jurairutporn Jan 2019

Gene Expression Analysis Of Mmp12 And S100a4 Of Grafted Bone Using Allograft And Xenograft In Mice, Tipaporn Jurairutporn

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objectives: This study aimed to evaluate the genes of interest that could explain osteoblast and osteoclast activities in bone remodeling after bone grafting with demineralized freeze-dried bone allograft) (DFDBA) and demineralized bovine bone mineral (DBBM) to compare with normal bone healing. Methods: Calvarium defects were created on both side of the parietal bone in nine male C57BL/6MLac mice. Defects were divided into 3 groups; group 1: defect without grafting as a control group, group 2: defect grafted with DFDBA, and group 3: defect grafted with DBBM. The mRNA expression levels of MMP12 and S100A4 were analyzed using real-time PCR in …


การเปรียบเทียบปริมาณรังสีกระเจิงกลับจากวัสดุทางทันตกรรมชนิดโลหะขณะที่ได้รับรังสีรักษา, ธัญสินี คูณาภินันท์ Jan 2019

การเปรียบเทียบปริมาณรังสีกระเจิงกลับจากวัสดุทางทันตกรรมชนิดโลหะขณะที่ได้รับรังสีรักษา, ธัญสินี คูณาภินันท์

Chulalongkorn University Theses and Dissertations (Chula ETD)

อุบัติการณ์ของผู้ป่วยที่เป็นมะเร็งบริเวณช่องปากในประเทศไทยพบว่ามีประมาณร้อยละ 5.4 ของประชากรทั้งหมดทั้งในเพศชายและเพศหญิง ผู้ป่วยเหล่านี้อาจได้รับการฉายรังสีรักษาก่อน และ/หรือหลังการรักษาจากการผ่าตัด วัสดุทางทันตกรรมหลายชนิดที่มีการกระเจิงกลับของรังสีรักษาจะส่งผลทำให้เกิดปริมาณรังสีกระเจิงกลับบริเวณรอบๆเนื้อเยื่อในช่องปากหรือกระดูกที่ติดกับวัสดุเหล่านี้เพิ่มขึ้นและเกิดผลข้างเคียงตามมาคือภาวะเยื่อบุช่องปากอักเสบและการเกิดกระดูกตาย วัตถุประสงค์ของงานวิจัยนี้จึงทำเพื่อศึกษาและเปรียบเทียบปริมาณรังสีกระเจิงกลับของวัสดุทางทันตกรรมชนิดโลหะ 4 ชนิดคือ โลหะผสมทองชนิดที่ 4, แพลลาเดียมอัลลอย, ไทเทเนียมบริสุทธิ์เชิงพาณิชย์ (ระดับ 4) และไทเทเนียมอัลลอยที่ผลิตโดยวิธีเลเซอร์เผาผนึก โดยนำมาฉายด้วยรังสีโฟตอนขนาด 200 cGy และให้พลังงานรังสี 6 MV จากเครื่องฉายรังสีชนิดเร่งอนุภาคเชิงเส้น(ลิแนค) ซึ่งเป็นรังสีที่มีชนิดและขนาดเดียวกับรังสีที่ใช้รักษามะเร็งศีรษะและลำคอ ในการทดลองจะฉายรังสีจำนวน 2 ครั้งต่อกลุ่มชนิดโลหะ โดยแต่ละกลุ่มชนิดโลหะจะประกอบไปด้วยชิ้นงานขนาด 8x13x1 มม.3 จำนวน 5 ชิ้น แต่ละชิ้นงานจะมีแผ่นวัดรังสีโอเอสแอลประกบแนบสนิทอยู่ด้านบนเพื่อทำการวัดปริมาณรังสีกระเจิงกลับที่ระยะประชิดผิวชิ้นงาน(0 มม.) จากนั้นจึงทำการคำนวณหาร้อยละของปริมาณรังสีกระเจิงกลับที่เพิ่มขึ้นจากวัสดุทางทันตกรรมชนิดโลหะทั้ง 4 ชนิดและเปรียบเทียบข้อมูลระหว่างกลุ่มโดยใช้สถิติชนิดวิเคราะห์ความแปรปรวนทางเดียว (One-way ANOVA) ที่ระดับความเชื่อมั่นร้อยละ 95 และใช้ Post Hoc Test คือ Bonferroni ผลการวิจัยพบว่าเมื่อเปรียบเทียบปริมาณรังสีกระเจิงกลับและร้อยละของปริมาณรังสีที่เพิ่มขึ้นระหว่างกลุ่มโลหะผสมทองและแพลลาเดียมอัลลอย เทียบกับไทเทเนียมบริสุทธิ์เชิงพาณิชย์ (ระดับ 4) และไทเทเนียมอัลลอยที่ผลิตโดยวิธีเลเซอร์เผาผนึกนั้นมีความแตกต่างกันอย่างมีนัยสำคัญทางสถิติ อย่างไรก็ตามพบว่าไม่มีความแตกต่างกันอย่างมีนัยสำคัญทางสถิติของปริมาณรังสีกระเจิงกลับและร้อยละของปริมาณรังสีกระเจิงกลับที่เพิ่มขึ้นระหว่างกลุ่มไทเทเนียมบริสุทธิ์เชิงพาณิชย์ (ระดับ 4) และไทเทเนียมอัลลอยที่ผลิตโดยวิธีเลเซอร์เผาผนึก สรุปได้ว่าปริมาณรังสีกระเจิงกลับที่เพิ่มขึ้นในกลุ่มวัสดุทางทันตกรรมชนิดโลหะ 4 ชนิดเรียงลำดับจากน้อยที่สุดไปมากที่สุดคือ ไทเทเนียมอัลลอยที่ผลิตโดยวิธีเลเซอร์เผาผนึก, ไทเทเนียมบริสุทธิ์เชิงพาณิชย์ (ระดับ 4), แพลลาเดียมอัลลอย และโลหะผสมทอง


กำลังแรงยึดเฉือนระหว่างแบร็กเกตจัดฟันโลหะกับเซอร์โคเนียที่ใช้การปรับสภาพผิวและเรซินแอดฮีซีฟที่แตกต่างกัน, พลอยลดา วิทวัสพันธุ์ Jan 2019

กำลังแรงยึดเฉือนระหว่างแบร็กเกตจัดฟันโลหะกับเซอร์โคเนียที่ใช้การปรับสภาพผิวและเรซินแอดฮีซีฟที่แตกต่างกัน, พลอยลดา วิทวัสพันธุ์

Chulalongkorn University Theses and Dissertations (Chula ETD)

วัตถุประสงค์ของการทดลองนี้เพื่อเปรียบเทียบกำลังแรงยึดเฉือนระหว่างแบร็กเกตจัดฟันโลหะกับเซอร์โคเนียที่ผ่านการปรับสภาพผิวที่แตกต่างกัน เตรียมเซอร์โคเนียขนาด 8 x 8 x 2 มิลลิเมตร จำนวน 12 กลุ่ม กลุ่มละ 10 ชิ้น เผาซินเทอร์ นำไปฝังลงในท่อพีวีซีด้วยยิปซัมทางทันตกรรมและขัดเรียบ ผิวของเซอร์โคเนียถูกปรับสภาพผิวโดยการพ่นผงอะลูมิเนียมออกไซด์ (S) การกรอด้วยเข็มกรอกากเพชร (G) การทาสารปรับปรุงผิวเซอร์โคเนียไพรเมอร์ (Z) การพ่นผงอะลูมิเนียมออกไซด์ร่วมกับทาสารปรับปรุงผิวเซอร์โคเนียไพรเมอร์ (SZ) การกรอด้วยเข็มกรอกากเพชรร่วมกับทาสารปรับปรุงผิวเซอร์โคเนียไพรเมอร์ (GZ) และกลุ่มที่ไม่ได้ปรับสภาพผิวเป็นกลุ่มควบคุม จากนั้นแบ่งชิ้นงานออกเป็นสองกลุ่ม กลุ่มที่หนึ่งนำแบร็กเกตจัดฟันมาเชื่อมติดชิ้นงานด้วยเรซินแอดฮีซีฟทรานสบอนด์ เอ็กซ์ที (TransbondTM XT) กลุ่มที่สองนำแบร็กเกตจัดฟันมาเชื่อมติดชิ้นงานด้วยเรซินซีเมนต์รีไลน์เอ็กซ์ยูสองร้อย (RelyXTM U200) จากนั้นแช่ไว้ในน้ำกลั่นที่อุณหภูมิ 37 องศาเซลเซียส เป็นเวลา 24 ชั่วโมง จากนั้นทดสอบค่ากำลังแรงยึดเฉือนด้วยเครื่องทดสอบอเนกประสงค์ โดยใช้ความเร็วในการทดสอบที่ 1 มิลลิเมตรต่อนาที ศึกษาลักษณะความล้มเหลวที่เกิดขึ้นด้วยกล้องจุลทรรศน์ชนิดสเตอริโอ และวิเคราะห์พื้นผิวของเซอร์โคเนียด้วยกล้องจุลทรรศน์อิเล็กตรอนชนิดส่องกราด จากนั้นนำผลที่ได้มาวิเคราะห์ทางสถิติเปรียบเทียบโดยใช้การวิเคราะห์ความแปรปรวนแบบสามทาง (Three-way ANOVA) ใช้สถิติความแปรปรวนแบบทางเดียว (One-way ANOVA) และสถิติเวลช์ (Welch) เปรียบเทียบค่ากำลังแรงยึดเฉือนแต่ละกลุ่ม ที่ระดับนัยสำคัญ 0.05 จากผลการศึกษาพบว่าการใช้เข็มกรอกากเพชร กรอที่ผิวเซอร์โคเนียช่วยเพิ่มความขรุขระที่ผิวและสามารถเพิ่มค่ากำลังแรงยึดเฉือนได้ดีกว่าการพ่นผงอะลูมิเนียมออกไซด์ และไม่ได้รับการปรับสภาพพื้นผิวเชิงกล การทาสารปรับปรุงผิวเซอร์โคเนียไพรเมอร์ (MDP) ให้ค่ากำลังแรงยึดเฉือนมากกว่ากลุ่มที่ไม่ได้ทาสารปรับปรุงผิวเซอร์โคเนียไพรเมอร์ในทุกกลุ่ม หากไม่ได้ทาสารปรับปรุงผิวเซอร์โคเนียไพรเมอร์ กลุ่มที่ใช้เรซินซีเมนต์รีไลน์เอ็กซ์ยูสองร้อยให้ค่ากำลังแรงยึดเฉือนสูงกว่ากลุ่มที่ใช้เรซินแอดฮีซีฟทรานสบอนด์ เอ็กซ์ที อย่างมีนัยสำคัญอย่างมีนัยสำคัญ (p<0.05) การปรับสภาพผิวเซอร์โคเนียด้วยการกรอด้วยเข็มกรอกากเพชรร่วมกับการทาสารปรับปรุงผิวเซอร์โคเนียไพรเมอร์ มีประสิทธิภาพในการเพิ่มแรงยึดของแบร็กเกตจัดฟันซึ่งอาจลดปัญหาการหลุดของแบร็กเกตขณะรักษาและเพิ่มความสำเร็จของการรักษาได้


การเปรียบเทียบกำลังแรงยึดเฉือนของเซอร์โคเนียชนิดใส เมื่อยึดด้วยเรซินซีเมนต์ที่ประกอบด้วยหมู่ฟอสเฟตต่างชนิด, ศิรวิชญ์ จิตสุธีศิริ Jan 2019

การเปรียบเทียบกำลังแรงยึดเฉือนของเซอร์โคเนียชนิดใส เมื่อยึดด้วยเรซินซีเมนต์ที่ประกอบด้วยหมู่ฟอสเฟตต่างชนิด, ศิรวิชญ์ จิตสุธีศิริ

Chulalongkorn University Theses and Dissertations (Chula ETD)

เซอร์โคเนียชนิดใสในงานทันตกรรมมีแนวโน้มถูกใช้โดยทันตแพทย์เพิ่มมากขึ้นในปัจจุบัน เนื่องจากความแข็งแรง และความสวยงามโดยไม่จำเป็นต้องพอกผิวด้วยพอร์ซเลน การยึดวัสดุดังกล่าวต่อฟันมีผลต่อความยั่งยืนของการบูรณะ เรซินซีเมนต์ที่มีฟอสเฟตมอนอเมอร์ชนิดต่างๆถูกอ้างว่าให้แรงยึดที่ดีกว่าต่อวัสดุเซอร์โคเนียชนิดใส หากแต่ยังไม่มีความชัดเจนในศักยภาพของฟอสเฟตมอนอเมอร์ งานวิจัยนี้จึงมีวัตถุประสงค์เพื่อต้องการศึกษาค่ากำลังแรงยึดเฉือนของเรซินซีเมนต์สองชนิดที่ประกอบด้วยหมู่ฟอสเฟตต่างชนิดกันบนเซอร์โคเนียชนิดใสต่อคอมโพสิตเรซิน โดยพื้นที่ยึดติดได้ถูกกำหนดตาม ISO 29022:2013 เซอร์โคเนียชนิดใส (Ceramill® zolid fx White) จึงถูกเตรียมให้มีเส้นผ่านศูนย์กลาง 8.5 มม. หนา 3.2 มม. จำนวน 32 แผ่น และถูกนำมายึดกับคอมโพสิตเรซินชนิดนาโนคอมโพสิต (FiltekTM Z350 XT) ผ่านศูนย์กลาง 3.0 มม. หนา 2.0 มม. ด้วยเรซินซีเมนต์สองชนิดคือ PANAVIA ™ V5 และ Rely X ™ U200 โดยเรซินซีเมนต์แต่ละชนิดจะถูกแบ่งออกอีกเป็นสองกลุ่ม ได้แก่กลุ่มที่ใช้ร่วมกับ Clearfil ceramic primer plus และกลุ่มที่ไม่ใช้ร่วมกับ Clearfil ceramic primer plus ทำให้แบ่งกลุ่มตัวอย่างออกได้เป็น 4 กลุ่ม กลุ่มละ 8 ชิ้น และความหนาของเรซินซีเมนต์ถูกกำหนดตาม ISO 4049:2009 ภายหลังการยึดติดชิ้นงานทุกชิ้นถูกนำไปผ่านกระบวนการเทอร์โมไซคลิงจำนวน 5,000 รอบ และถูกทดสอบกำลังแรงยึดเฉือนจนชิ้นคอมโพสิตเรซินหลุดด้วยเครื่องทดสอบแรงดึงแรงอัด(EZ-S, SHIMADZU) และสังเกตรูปแบบความล้มเหลวด้วยกล้องจุลทรรศน์อิเล็กตรอนแบบส่องกราด(SEM)(FEI Quanta 250) ค่ากำลังแรงยึดเฉือนถูกคำนวณด้วยสถิติการวิเคราะห์ความแปรปรวนทางเดียว และเปรียบเทียบความแตกต่างระหว่างกลุ่มด้วยการทดสอบชนิดทูกีย์ (One-way ANOVA and Tukey’s post hoc test) ที่ระดับความเชื่อมั่นร้อยละ 95 ผลการทดลองกลุ่ม PANAVIA ™ V5 ร่วมกับ Clearfil ceramic primer plus แสดงกำลังแรงยึดเฉือนมากที่สุด (1.38 ± 0.39 เมกะพาสคาล) และมีรูปแบบความล้มเหลวแบบผสมร่วมกับเชื่อมแน่นล้มเหลว โดยความล้มเหลวแบบผสมมีค่าเฉลี่ยร้อยละปริมาณเรซินซีเมนต์คงเหลือบนเซอร์โคเนียชนิดใสมากที่สุด(ร้อยละ 48.56±9.44) กลุ่มPANAVIA …


The Effect Of Occlusal Pressure On Vertical Force Generation On Dentate And Edentulous Subjects, Matthew Thomas Harper Jan 2019

The Effect Of Occlusal Pressure On Vertical Force Generation On Dentate And Edentulous Subjects, Matthew Thomas Harper

Graduate Theses, Dissertations, and Problem Reports (ETD)

Objectives: To determine 1) the difference in lower extremity power obtained from a vertical jump in individuals who are dentate or edentulous (implants or dentures) and 2) the difference occlusal pressure makes on lower body force output. Variables included jump height, maximum kicking force, maximum push off force, take off velocity, flight time, jump impulse, and maximum velocity. Groups included dentate, implant overdenture, and conventional denture.

Methods: Counter movement jumping with force plate collection was utilized to test the three populations in this study. The three populations were dentate, mandibular implant overdenture opposing maxillary complete denture, and conventional maxillary and …


In-Vitro Evaluation Of Accuracy Of Conventional And Cad/Cam Removable Partial Denture Frameworks, Pooya Soltanzadeh Aug 2018

In-Vitro Evaluation Of Accuracy Of Conventional And Cad/Cam Removable Partial Denture Frameworks, Pooya Soltanzadeh

Loma Linda University Electronic Theses, Dissertations & Projects

Purpose: Computer-aided design/computer-aided manufacturing (CAD/CAM) technology is gaining popularity in dentistry, and more recently, to fabricate removable partial dentures (RPD). The purpose of this study was 1) to evaluate the overall accuracy and fit of conventional versus CAD/CAM fabricated printed RPD frameworks based on STL data analysis, and 2) to evaluate the accuracy and fit of each component of the RPD framework. Materials and Methods: A maxillary metal framework was designed for a Kennedy class III modification I situation. The master model was scanned and used to compare the fit and accuracy of the RPD frameworks. A total of 40 …


The Wear Of Acrylic Resin And Composite Resin Teeth Against Polished And Glazed Zirconia, Abdulkareem Alshehri Aug 2018

The Wear Of Acrylic Resin And Composite Resin Teeth Against Polished And Glazed Zirconia, Abdulkareem Alshehri

Loma Linda University Electronic Theses, Dissertations & Projects

Background: Excessive wear for the occlusal surfaces of teeth results in decreased masticatory efficiency, poor esthetics and leads to reduced the occlusal vertical dimension which could lead to the development of temporomandibular disorders, consequently, further compromise function. Very few studies have been performed on the wear resistance of zirconia against artificial denture teeth and human enamel. Aim: The purpose of this study was to investigate the influence of polished zirconia (PZ) and glazed zirconia (GZ) on the 2-body wear resistance (vertical substance loss) of seven commercially available denture teeth made of different resins. Material and Method: Eight groups (n=10) of …


Design Of Parallel Robot For Dental Articulation And Its Optimization, Abulimiti Delimulati Aug 2018

Design Of Parallel Robot For Dental Articulation And Its Optimization, Abulimiti Delimulati

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

A dental articulator is a mechanical device used to simulate the relative position and motion between the upper and lower jaw when constructing and testing dental prostheses. Typically, it can be adjusted to approximate patient-specific jaw kinematics in order to analogue the static relationship and specific motions of a patient’s mandible to maxilla. However, the use of dental articulators is essentially a trial-and-error method in order to fine-tune fit and function of a dental prosthesis. Some of the most advanced current dental articulators can reproduce the position and the motion passively; furthermore, dentists need special training for measuring patients’ maxillofacial …


Managing Patient Expectations With Implant Treatment, Daniel B. Kamran, Mark Booth Dds, Eduardo Gonzalez Dds, Ed Shaw Dds May 2018

Managing Patient Expectations With Implant Treatment, Daniel B. Kamran, Mark Booth Dds, Eduardo Gonzalez Dds, Ed Shaw Dds

Excellence Day

This patient came to University of the Pacific, Arthur A. Dugoni School of Dentistry to get implants and implant crowns to improve his smile, replacing his upper partial denture. Different approaches were made by the faculty to arrive at best outcomes, which took four years for the patient to receive the treatment he wanted. This abstract will further detail how the treatment was conducted and the results afterwards.


Root Analogue Implant Creation: Establishing Procedures For The General Dentist, Alicia Hazdovac, Sarah Osborne, Gary D. Richards May 2018

Root Analogue Implant Creation: Establishing Procedures For The General Dentist, Alicia Hazdovac, Sarah Osborne, Gary D. Richards

Excellence Day

The possibility of replacing damaged teeth with custom-made root analogue implants was initially suggested around 1969 and reintroduced by Lungren et al. in 1992. The latter authors created custom implants in titanium and reported good osteointegration and aesthetic results. Following this effort there has been an increasing focus on custom root analogue implants as a replacement for ‘screw-type’ implants. Given the availability of software to manipulate 3D image data and the rapid rise of 3D printing technology, the question arises as to whether a general dentist can produce their own implants. Here we test the feasibility of practitioners producing custom …


Effect Of Emergence Profile Of A Single Implant Restoration On The Health Of Peri-Implant Soft Tissue, Waleed Nasir Asiri Apr 2018

Effect Of Emergence Profile Of A Single Implant Restoration On The Health Of Peri-Implant Soft Tissue, Waleed Nasir Asiri

Master's Theses (2009 -)

Purpose: The specific aims of this retrospective study were 1) to compare the emergence angle of a single implant crown (SIC) of the mandibular first molar to the emergence angle of the natural contralateral tooth, 2) to evaluate the effect of the emergence angle of SIC on the health of the peri-implant soft tissue and 3) to quantify an acceptable emergence angle among SIC. Materials and methods: Ten Marquette University School of Dentistry (MUSoD) patients were included in the study. Each patient was examined clinically and plaque index (PI), probing depth (PD), and bleeding on probing (BOP) measurements were gathered …


Effect Of Different Finish Line Designs On The Marginal And Internal Fit Of Metal Copings Made By Selective Laser Melting Technology, Adel Al Maaz Apr 2018

Effect Of Different Finish Line Designs On The Marginal And Internal Fit Of Metal Copings Made By Selective Laser Melting Technology, Adel Al Maaz

Master's Theses (2009 -)

Introduction: Marginal fit has been defined as the gap between the prepared tooth and the intaglio surface of the restoration. Internal gap is the perpendicular measurement from the internal surface of the casting to the axial wall of the preparation. Selective laser melting has been used for fabrication of metal copings such as Co-Cr base alloys and Au-Pt noble alloys. The purpose of this study was to determine the effect of different finish line designs on the marginal and internal fit of metal copings made from high noble, 25% noble and base alloys manufactured by SLM technology. Material and Methods: …


Short Length Versus Conventional Implants In Rehabilitation Of Completely Edentulous Mandible, Fardos N. Rizk, Engy Tallat, Mahmoud Elhomossany, Ahmed Lasheen Dr., Hebatalla Mahmoud Jan 2018

Short Length Versus Conventional Implants In Rehabilitation Of Completely Edentulous Mandible, Fardos N. Rizk, Engy Tallat, Mahmoud Elhomossany, Ahmed Lasheen Dr., Hebatalla Mahmoud

Dentistry

Various bone augmentation strategies have been proposed to overcome the anatomic and physiologic limitations of implant placement in patients with atrophic edentulous ridges. The use of short implants may provide an alternative treatment to avoid complications associated with alveolar bone augmentation. However, the clinical effectiveness of short implants versus long implants was not thoroughly investigated. Marginal bone height changes around short and conventional implants were evaluated in this study Methods: Fourteen completely edentulous male patients were selected and divided into two equal groups. Group (I) Patients received conventional complete maxillary dentures opposed by mandibular overdentures supported and retained by two …


Color Stability, Water Sorption And Water Solubility Of Various Artificial Acrylic Resin Teeth, Piyaporn Foungfu Jan 2018

Color Stability, Water Sorption And Water Solubility Of Various Artificial Acrylic Resin Teeth, Piyaporn Foungfu

Chulalongkorn University Theses and Dissertations (Chula ETD)

Color stability, water sorption and water solubility of the acrylic resin artificial teeth are the success keys to the appearance and mechanical properties of the denture teeth. The objective of the present study was to compare the color stability, water sorption and water solubility of 3 commercial artificial teeth: linear PMMA (NEW), resin composite (CPX) and cross-linked PMMA (ANT) and 1 color-liked heat-polymerized acrylic resin (MAJ). 80 colume-shaped specimens (9 mm/ 2 mm thickness) were fabricated for color stability test using a spectrophotometer after immersing in water or coffee solution at 1, 7, 28, 56 and 84 days. 40 colume-shape …


Effect Of Different Polishing Systems, Forces, And Durations On Surface Roughness And Phase Transformation Of Monolithic Zirconia, Songsak Munkongsujarit Jan 2018

Effect Of Different Polishing Systems, Forces, And Durations On Surface Roughness And Phase Transformation Of Monolithic Zirconia, Songsak Munkongsujarit

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study aimed to determine the effect of polishing systems, forces and durations on the surface roughness and phase transformation of zirconia. 72 pieces of fully sintered zirconia size 7 x 5 x 4 mm were fabricated with CAD/CAM, then divided into nine groups depending on the polishing systems and forces. All specimens were ground with fine diamond bur as the control, and initial surface roughness (Ra) was measured. The samples were then polished with one of the zirconia polishing systems (Diazircon or Komet ZR) or porcelain polishing system (Ceramaster), with forces at 1, 2 and 3 newtons. The polishing …


Gene Expression Of Bcl2a1 และ Cxcl9 In Soft Tissue Covering Bone Grafting Materials, Borwonluk Taveedach Jan 2018

Gene Expression Of Bcl2a1 และ Cxcl9 In Soft Tissue Covering Bone Grafting Materials, Borwonluk Taveedach

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study was to assess the expression of Bcl2a1 and Cxcl9 genes in soft tissues covering bone grafted with demineralized freeze-dried bone allograft (DFDBA) and deproteinized bovine bone mineral (DBBM) in comparison with ones covering without grafting. The animals were randomly separated into three groups of treatment. Calvarial defect models were created on parietal bones. Bare defect models without bone graft as a control group. After one and three months, animals were sacrificed. Soft tissues covering the defected area were collected by punch technique. RNA was isolated and proceeded to Real-time reverse transcription quantitative polymerase chain reaction (RT-qPCR). Statistical analysis …


Fracture Resistance Of Non-Ferruled Endodontically Treated Teeth Restored With Different Fiber Post And Core Methods After Five Years Fatigue Loading, Puriwat Malakorn Jan 2018

Fracture Resistance Of Non-Ferruled Endodontically Treated Teeth Restored With Different Fiber Post And Core Methods After Five Years Fatigue Loading, Puriwat Malakorn

Chulalongkorn University Theses and Dissertations (Chula ETD)

The aim of this study was to compare the fracture resistance and failure mode of non-ferruled ETT restored with different fiber post and core methods after five years in vitro fatigue loading. Forty-eight uniradicular lower first premolar teeth were decoronated, endodontically treated and prepared for the post space. The prepared specimens were divided into four groups (n=12): single fiber-reinforced composite (FRC) post and flowable resin composite core (Group I), FRC post with an accessory fiber post and flowable resin composite core (Group II), resin composite relined FRC post and resin composite core (Direct anatomic post)(Group III), and resin composite relined …


Effect Of Methyl Formate-Methyl Acetate Treatment On Flexural Strength Between Denture Base And Self-Cured Hard Reline Materials, Mongkol Puangpetch Jan 2018

Effect Of Methyl Formate-Methyl Acetate Treatment On Flexural Strength Between Denture Base And Self-Cured Hard Reline Materials, Mongkol Puangpetch

Chulalongkorn University Theses and Dissertations (Chula ETD)

The purpose of this study was to evaluate the effect of methyl formate-methyl acetate (MF-MA) surface treatment on the flexural strength between denture base and hard reline materials. 180 heat-cured acrylic denture base (Meliodent®) specimens were prepared according to ISO 20795-1 (2013) and divided into 18 groups with various autopolymerizing hard reline materials. Group I-III: relined with Unifast Trad®, Group IV-VI: relined with Kooliner® Group VII-IX: relined with Tokuyama® Rebase II Fast (without adhesive, with hardener), Group X-XII: relined with Tokuyama® Rebase II Fast (with adhesive and hardener), Group XIII-XV: relined with Tokuyama® Rebase II Fast (without adhesive and hardener), …


Effect Of Citric Acid On Color Stability And Surface Roughness Of Translucent Monolithic Zirconia With Different Staining Techniques, Panisa Rinthong Jan 2018

Effect Of Citric Acid On Color Stability And Surface Roughness Of Translucent Monolithic Zirconia With Different Staining Techniques, Panisa Rinthong

Chulalongkorn University Theses and Dissertations (Chula ETD)

Background and rationale: Translucent monolithic zirconia is developed to solve the problem of esthetic in the conventional generation of zirconia with high opacity. When these materials are used for anterior restoration in the oral cavity, they can contact with foods and beverages that are acidic, which may affect the color stability and surface roughness of the material at different levels. Objective: The objective of this study was to determine the effects of citric acid on color stability and surface roughness of translucent monolithic zirconia with different staining techniques. Materials and Methods: A total of 80 disc specimens of VITA YZ® …


Comparison Of The Efficacy Of Chemical Cleaning Methods In Removing Candida Albicans From Polymethyl Methacrylate, Thanaporn Thanamee Jan 2018

Comparison Of The Efficacy Of Chemical Cleaning Methods In Removing Candida Albicans From Polymethyl Methacrylate, Thanaporn Thanamee

Chulalongkorn University Theses and Dissertations (Chula ETD)

The proper denture hygiene is important to reduce the risk of denture stomatitis. Mechanical cleaning is not sufficient to remove the dental plaque from acrylic denture base, accordingly chemical cleaning is needed. The purpose of this study was to compare the efficacy of chemical cleaning methods in removing Candida albicans from polymethyl methacrylate (PMMA) by comparing the remaining viable cells after cleaning. The total of 120 specimens were prepared. Candida albicans was cultured in broth to log phase. All specimens were randomly placed in 24-well tissue culture plate with 1 ml of Candida albicans cultured for biofilm formation at 37 …


Effect Of Various Curing Conditions In Pressure Cooker On Flexural Strength Of Denture Hard Relining Materials, Thassanee Suwannachote Jan 2018

Effect Of Various Curing Conditions In Pressure Cooker On Flexural Strength Of Denture Hard Relining Materials, Thassanee Suwannachote

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study evaluated the effect of various curing conditions in pressure cooker on flexural strength of hard chairside reline resins (UnifastTM Trad, Tokuyama® Rebase II Fast with and without Hardener®). For each material, 70 specimens were prepared and divided into 7 groups consists of control group and 6 experimental groups: cured in 2 bars air or nitrogen pressure cooker at 55ºC for 10, 15 and 20 min respectively. For Hardener® groups, specimens were soaked in Hardener® for 3 min after curing. The flexural strength was tested using a Universal testing machine. The data were analyzed using Three-way ANOVA, One-way ANOVA …


ผลของกาวติดฟันเทียมต่อประสิทธิภาพการบดเคี้ยวและแรงบดเคี้ยวสูงสุดในผู้ป่วยที่ใส่ฟันเทียมทั้งปาก, หยาดฝน พลศรี Jan 2018

ผลของกาวติดฟันเทียมต่อประสิทธิภาพการบดเคี้ยวและแรงบดเคี้ยวสูงสุดในผู้ป่วยที่ใส่ฟันเทียมทั้งปาก, หยาดฝน พลศรี

Chulalongkorn University Theses and Dissertations (Chula ETD)

วัตถุประสงค์เพื่อศึกษาผลของกาวติดฟันเทียมต่อประสิทธิภาพการบดเคี้ยว (masticatory performance) และแรงบดเคี้ยวสูงสุด (maximum occlusal force) ของผู้ป่วยฟันเทียมทั้งปาก ผู้ป่วยสันเหงือกว่างที่ใส่ฟันเทียมทั้งปากบนและล่างจำนวน 65 คน อายุเฉลี่ย 68.9±7.2 ปี เป็นเพศชาย 39 คน เพศหญิง 26 คน มีคุณภาพฟันเทียมอยู่ในระดับที่ยอมรับได้ (กลุ่ม A) และยอมรับไม่ได้ (กลุ่ม UA) จำนวน 44 และ 21 คน ตามลำดับ มีลักษณะของเนื้อเยื่อรองรับฟันเทียมตามระบบของ American College of Prosthodontists กลุ่ม I, II, III และ IV จำนวน 19 30 11 และ 5 คนตามลำดับ ผู้ป่วยเข้ารับการทดสอบประสิทธิภาพการบดเคี้ยวด้วยการเคี้ยวถั่วลิสงจำนวน 20 รอบวงเคี้ยว ถั่วลิสงที่ผ่านการเคี้ยวแล้วจะถูกร่อนผ่านเครื่องสั่น ด้วยตะแกรงทดสอบมาตรฐานจำนวน 12 ชั้น เพื่อวิเคราะห์หาขนาดอนุภาคกลางของถั่วลิสง (median particle size) และเข้ารับการทดสอบแรงบดเคี้ยวสูงสุดด้วยการกัดแผ่นฟิล์มที่อ่อนไหวต่อความดัน (pressure sensitive film) โดยวางแผ่นฟิล์มระหว่างด้านบดเคี้ยวของฟันเทียมบนและล่างในตำแหน่งสบสนิทที่สุด (maximum intercuspal position) วิเคราะห์และแปรผลด้วยโปรแกรมสถิติสำเร็จรูป เพื่อเปรียบเทียบประสิทธิภาพการบดเคี้ยวและแรงบดเคี้ยวสูงสุดระหว่างก่อน (T1) และหลังการใช้กาวติดฟันเทียมอย่างต่อเนื่องเป็นระยะเวลา 1 เดือน (T2) สถิติที่ใช้ในการทดสอบคือ paired t-test ที่ระดับความเชื่อมั่นร้อยละ 95 ผลการศึกษาพบว่าเมื่อเปรียบเทียบก่อนและหลังการใช้กาวติดฟันเทียม ประสิทธิภาพการบดเคี้ยวเพิ่มขึ้นอย่างมีนัยสำคัญในกลุ่ม A (P = 0.035) แต่ไม่มีความแตกต่างอย่างมีนัยสำคัญทางสถิตในกลุ่ม UA (P = 0.313) แรงบดเคี้ยวสูงสุดลดลงอย่างมีนัยสำคัญในกลุ่ม A (P = 0.020) แต่ไม่มีความแตกต่างอย่างมีนัยสำคัญทางสถิติในกลุ่ม UA (P …


Effect Of Image Sharpening On Radiographic Image Quality, Jefferson Lee Clark Jun 2017

Effect Of Image Sharpening On Radiographic Image Quality, Jefferson Lee Clark

Loma Linda University Electronic Theses, Dissertations & Projects

There is evidence that capture and processing of the digital radiographic images may contain artifacts that could reduce the diagnostic value of dental radiographs. This phenomenon has been reported through various case reports. However, its effect on radiographic image quality has not been studied. The purpose of this study is to evaluate the effect of image processing on the quality of dental digital radiographs using the most common type of filter; sharpening. Four imaging modalities (2 CMOS, 1 PSP, 1 conventional film) were used to radiograph a DDQA imaging phantom (Digital Dental Quality Assurance phantom) and to create a flat …


Analysis Of Flexural Strength And Monotonic Load To Failure Following Simulated Chairside Adjustments And Repair In A Lithium Disilicate Glass-Ceramic, Ali Ramadhan Apr 2017

Analysis Of Flexural Strength And Monotonic Load To Failure Following Simulated Chairside Adjustments And Repair In A Lithium Disilicate Glass-Ceramic, Ali Ramadhan

Master's Theses (2009 -)

Introduction: There are no studies regarding e.max Press that evaluate post-adjustment healing protocols and their effect on the load to failure in a clinically relevant test. It is essential to find the ultimate treatment protocol which will help clinicians preserve the physical properties of the ceramic restoration after adjustment. Material and Methods: The total number of samples used in this study was 440 IPS e.max press discs. The discs were 15 mm in diameter and 1 mm of thickness. The material was tested for flexural strength and monotonic load to failure. The test was done in two parts and with …


Comparison Of Anterior Denture Teeth Arrangements Made With The Tooth Mold Template And Definitive Computer-Aided Design & Computer-Aided Manufacturing Complete Removable Dental Prostheses, Jose Antonio Sierra Apr 2017

Comparison Of Anterior Denture Teeth Arrangements Made With The Tooth Mold Template And Definitive Computer-Aided Design & Computer-Aided Manufacturing Complete Removable Dental Prostheses, Jose Antonio Sierra

Master's Theses (2009 -)

Introduction: There is a dearth of information in the refereed literature regarding esthetics of CAD/CAM complete removable dental prostheses (CRDPs). The purpose of this study was to investigate and compare the anterior denture teeth arrangement made with the medium-size anterior tooth mold template to CAD/CAM complete removable dental prostheses fabricated with bonded denture teeth and milled teeth. Material and methods: Poly-vinyl siloxane impression were made of an edentulous maxillary model and selected for use as the patient template. The edentulous model was mounted on a semi-adjustable articulator. Definitive impressions and jaw relation records were made according to the manufacturer’s protocol. …


Effect Of One Piece Versus Two Piece Mini Implants On Bone Height Of Implant Retained Mandibular Overdenture, Fardos N. Rizk, Jehan Fikry Prof., Amr Badr, Ahmed Damarisy Dr. Jan 2017

Effect Of One Piece Versus Two Piece Mini Implants On Bone Height Of Implant Retained Mandibular Overdenture, Fardos N. Rizk, Jehan Fikry Prof., Amr Badr, Ahmed Damarisy Dr.

Dentistry

Introduction: Severely atrophied mandibles are a common problem within elderly completely edentulous patients. Given their small diameters, long height and self-tapping characteristics, miniimplant retained over-dentures are a valuable treatment option in such patients. Mini-implants are usually once-piece implants, however recently two-piece mini-implants were introduced with aim of addressing the angulation problems. The success of the latter has not been thoroughly studied. Crestal bone height measurements are normally used to evaluate implant success. Therefore this study was conducted to evaluate the effect of one piece versus two piece ERA mini implants on crestal bone height of implant retained mandibular over-denture. Materials …