Open Access. Powered by Scholars. Published by Universities.®

Prosthodontics and Prosthodontology Commons™

Open Access. Powered by Scholars. Published by Universities.®

International Arab Journal of Dentistry

Discipline
Keyword
Publication Year

Articles 1 - 30 of 30

Full-Text Articles in Prosthodontics and Prosthodontology

Effect Of Multiple Uses And Sterilization Of Abutment-Level Peek Implant Scan Bodies On Complete-Arch Intraoral Digital Scans Trueness: An In Vitro Study, Georgio Zeidan, Maryse Nassif, Ghida Lawand, Hani Tohme Oct 2026

Effect Of Multiple Uses And Sterilization Of Abutment-Level Peek Implant Scan Bodies On Complete-Arch Intraoral Digital Scans Trueness: An In Vitro Study, Georgio Zeidan, Maryse Nassif, Ghida Lawand, Hani Tohme

International Arab Journal of Dentistry

Introduction: Polyetheretherketone (PEEK) implant scanbodies (ISBs) offer favorable optical properties for digital impressions but may be susceptible to wear and dimensional changes with repeated clinical use and sterilization. While previous studies have examined these variables separately, no investigation has simultaneously evaluated their combined effects on abutment-level PEEK ISBs in complete-arch implant situations.

Aim: To evaluate the effect of multiple uses and autoclave sterilization of abutment-level PEEK implants can bodies on the trueness of complete-arch intraoral digital scans in an in vitro setting.

Methods: A maxillary edentulous reference cast with four implants in an All-on-4 configuration was fabricated …


Influence Of Head Posture In Sitting And Standing Positions On The Vertical Dimension Of Rest Value In Dentate Patients: A Comparative Clinical Study, Mia Bardawil, Carole Abi Ghosn, Jihad Fakhouri Oct 2026

Influence Of Head Posture In Sitting And Standing Positions On The Vertical Dimension Of Rest Value In Dentate Patients: A Comparative Clinical Study, Mia Bardawil, Carole Abi Ghosn, Jihad Fakhouri

International Arab Journal of Dentistry

Introduction: This study investigates the value of the vertical dimension of rest (VDR) in dentate patients in different head postures, supported and unsupported by the headrest of the dental chair, as well as in standing position.

Methods: The VDR was measured and compared in 60 dentate individuals aged 20–25 in different positions (sitting with and without head support, and standing) three times per position. The head was aligned according to the Frankfurt plane when unsupported or standing. Data were analyzed using the Shapiro-Wilk test for normality and ANOVA to assess the effects of posture, gender, and their interaction. …


Comparative Evaluation Of The Effect Of Different Desensitising Methods On The Retention Of Crowns Cemented With Resin Modified Gic: An In-Vitro Study, Zainab Inayatullah, Kartika N. Kumar, Punit Rs Khurana, Anju Aggarwal, Aditya Chaudhary, Naila Perween Oct 2026

Comparative Evaluation Of The Effect Of Different Desensitising Methods On The Retention Of Crowns Cemented With Resin Modified Gic: An In-Vitro Study, Zainab Inayatullah, Kartika N. Kumar, Punit Rs Khurana, Anju Aggarwal, Aditya Chaudhary, Naila Perween

International Arab Journal of Dentistry

Introductions: This in vitro study aimed to evaluate and compare the effect of three different desensitizing methods— Admira Protect, dentin bonding agent (Tetric N Bond), and diode laser—on the retention of porcelain-fused-to-metal (PFM) crowns cemented with resin-modified glass ionomer cement (RMGIC).

Methods: Forty extracted, non-carious human premolars were prepared for full-coverage crowns and divided into four groups (n = 10): Group I (Control, no desensitizer), Group II (Admira Protect), Group III (Dentin bonding agent), and Group IV (Diode laser). Standardized tooth preparations were performed and PFM crowns were fabricated and cemented using RMGIC (RelyX Luting 2, 3M ESPE). …


Comparing Condylar Parameters Assessed By Ultrasonic And Mechanical Axiography: An In Vivo Pilot Study, Mark Salame, Amine El Zoghbi, Marina Daher, Carole Abi Ghosn, Paul J. Boulos Oct 2026

Comparing Condylar Parameters Assessed By Ultrasonic And Mechanical Axiography: An In Vivo Pilot Study, Mark Salame, Amine El Zoghbi, Marina Daher, Carole Abi Ghosn, Paul J. Boulos

International Arab Journal of Dentistry

Objectives: The objective of this clinical pilot study was to compare the condylar parameters (condylar path inclination and Bennett angle) obtained from two different axiographs: a mechanical axiography system and an ultrasonic axigraphy system, and thus to judge the reliability and degree of accuracy of the mechanical axiography compared with the ultrasonic axiography considered as a reference technique.

Methods: Eleven candidates, aged between 20 and 25 years, were selected (n = 11) following strict inclusion and exclusion criteria. Each individual underwent two axiographic recordings by a single experienced operator. The first one was done with an ultrasonic axiograph, …


Comparison Of Three Intraoral Scanners For Digital Impressions Of Biologically Oriented Preparation: An In-Vivo Study, Lara Habli, Pascale Habre-Hallage, Hani Tohme, Dany Noujaim, Maryse Nassif, Camille Haddad Jul 2026

Comparison Of Three Intraoral Scanners For Digital Impressions Of Biologically Oriented Preparation: An In-Vivo Study, Lara Habli, Pascale Habre-Hallage, Hani Tohme, Dany Noujaim, Maryse Nassif, Camille Haddad

International Arab Journal of Dentistry

Introduction: The accuracy of intraoral scanners (IOSs) in capturing a Biologically Oriented Preparation Technique (BOPT) remains uncertain. The aim of this study was to evaluate the accuracy of digital impressions obtained with three intraoral scanners for recording BOPT preparations.

Methods: A maxillary central incisor was prepared following BOPT. After temporization, a conventional polyvinyl siloxane impression was scanned with a desktop scanner to obtain a reference model. Forty-two scans (n D 14 per scanner) were recorded with three IOSs—Trios 3, Sirios, and Helios 680—by a single operator under standardized conditions. Accuracy was assessed using Geomagic Control X by calculating 3D surface …


Influence Of Veneer Thickness On Double Bond Conversion Of Preheated Composite And Self-Adhesive Resin Cement Under Lithium Disilicate Restorations: An In-Vitro Study., Vanessa Kanaan, Marie Abboud, Alexandre Monnier, Dani Irani, Vana Mardirossian, Cynthia Kassis Jul 2026

Influence Of Veneer Thickness On Double Bond Conversion Of Preheated Composite And Self-Adhesive Resin Cement Under Lithium Disilicate Restorations: An In-Vitro Study., Vanessa Kanaan, Marie Abboud, Alexandre Monnier, Dani Irani, Vana Mardirossian, Cynthia Kassis

International Arab Journal of Dentistry

Introduction: This study evaluated the influence of lithium disilicate restoration thickness on the degree of conversion (DC) of a self-adhesive dual-cured resin cement (Bifix SE®; VOCO GmbH, Cuxhaven, Germany) and a preheated composite resin (VisCalor Bulk®; VOCO GmbH, Cuxhaven, Germany).

Methods: Sixty IPS e.max CAD (LTB1) specimens (2 mm, 4 mm, 6 mm; n D 10 per group) were fabricated and divided into six groups. Groups 1–3 were luted with Bifix SE, and Groups 4–6 with preheated VisCalor Bulk. Specimens were conditioned with 5% hydro_uoric acid and silane, then cemented and light cured. Raman spectroscopy was used to determine DC. …


Predictive Analysis For Success And Complications In Dental Implant Therapy Using Artificial Intelligence Models, Vishnu Priya Veeraraghavan, Aysha Jebin A, Isha Dusane, Govind Baheti, Ankita Agarwal, Santosh R Patil Jul 2026

Predictive Analysis For Success And Complications In Dental Implant Therapy Using Artificial Intelligence Models, Vishnu Priya Veeraraghavan, Aysha Jebin A, Isha Dusane, Govind Baheti, Ankita Agarwal, Santosh R Patil

International Arab Journal of Dentistry

Introduction: Dental implant therapy is a predictable treatment for tooth replacement, but its success is influenced by multiple patient, surgical, and systemic factors. Traditional statistical models, such as logistic regression, are limited in capturing nonlinear relationships among these variables. Artificial intelligence (AI) can integrate diverse predictors to enhance clinical risk assessment and improve treatment outcomes.

Objective: To identify key predictors of dental implant success and develop AI-based models capable of accurately forecasting implant outcomes using clinical and surgical parameters.

Methods: This retrospective cohort study analyzed data from 172 patients (219 implants) placed between 2020 and 2021. Patient demographics, systemic health …


Effect Of Home Bleaching With Carbamide Peroxide And Over-The-Counter Products On Stained Supra-Nano-Filled Composite: An In-Vitro Study., Lynn Harrouk, Pascale Habre, Samar Bou Jaoude, Carina Mehanna Zogheib Jul 2026

Effect Of Home Bleaching With Carbamide Peroxide And Over-The-Counter Products On Stained Supra-Nano-Filled Composite: An In-Vitro Study., Lynn Harrouk, Pascale Habre, Samar Bou Jaoude, Carina Mehanna Zogheib

International Arab Journal of Dentistry

Objective: This study evaluated the impact of home and over-the-counter (OTC) bleaching products, compliant with SCCS regulations, on color changes in tea-stained supra-nano filled composite, using the CIEDE2000 formula.

Methods: One hundred Estelite® Sigma Quick discs were fabricated, thermocycled, and tea-stained for 12 days. Samples were divided into four groups: Opalescence 15% carbamide peroxide (CP) gel, White Dental Beauty 6% hydrogen peroxide (HP) strips, Pola Luminate 6% HP brush-on gel, and a control. Color was measured at baseline, post-staining, and post-bleaching using a VITA EasyShade spectrophotometer. ΔE₀₀ values were analyzed with Kruskal-Wallis and Dunn’s post-hoc tests (p < 0.05).

Results: All bleaching …


Study Of The Changes In Vestibular Bone Plate Absorption Values After Implant Placement Under Immediate Loading For A Period Of 5 Months Using Cbct: An In Vivo Study, Hassen Merzouk, Samir Habibi, Ben Ali Boutabout Apr 2026

Study Of The Changes In Vestibular Bone Plate Absorption Values After Implant Placement Under Immediate Loading For A Period Of 5 Months Using Cbct: An In Vivo Study, Hassen Merzouk, Samir Habibi, Ben Ali Boutabout

International Arab Journal of Dentistry

Introduction: The study focuses on the success and durability of dental implants, which depends heavily on the bone surrounding them. Changes in this bone affect how the implant looks and functions. The researchers aimed to use CBCT, a modern three-dimensional imaging tool, to accurately measure changes in the thickness of the bone plate on the cheek side (vestibular bone plate) around implants placed in the lower jaw (mandible). Specifically, they looked at bone changes five months after placing implants that were immediately loaded (meaning they were used for chewing right away) in 15 patients who had missing molars or premolars. …


Influence Of Ceramic Thickness And Cad/Cam Ceramic Materials On The Fracture Resistance Of Indirect Restorations: An In Vitro Study, Lara El Hanach, Karim Corbani, Nabil Ghosn, Ryan Harouny, Cynthia Kassis Mar 2026

Influence Of Ceramic Thickness And Cad/Cam Ceramic Materials On The Fracture Resistance Of Indirect Restorations: An In Vitro Study, Lara El Hanach, Karim Corbani, Nabil Ghosn, Ryan Harouny, Cynthia Kassis

International Arab Journal of Dentistry

Objectives: This in-vitro study aimed to evaluate the impact of different CAD/CAM materials (IPS e.max® CAD and Cerasmart®) and thicknesses (0.7 mm, 1 mm, and 1.5 mm) on the fracture resistance of indirect overlay restorations.

Methods: Sixty-three human third molars were divided into 7 groups (n=9) based on material and thickness, including a control group of 9 sound teeth. Only 54 specimens were prepared using a thin-section cutting machine, scanned, and their scans were used to fabricate overlays from different materials and thicknesses. After adhesive cementation, the overlays underwent thermal cyclic loading (5,000 cycles between 5°C and 55°C). A universal …


Effect Of Different Deep Margin Elevation Thicknesses Versus No Elevation On The Fracture Resistance Of Indirect Restorations: An In-Vitro Study, Fleurene Daraze, Karim Corbani, Brigitte Douaihy, Hadi Jomaah, Cynthia Kassis Dec 2025

Effect Of Different Deep Margin Elevation Thicknesses Versus No Elevation On The Fracture Resistance Of Indirect Restorations: An In-Vitro Study, Fleurene Daraze, Karim Corbani, Brigitte Douaihy, Hadi Jomaah, Cynthia Kassis

International Arab Journal of Dentistry

Objectives: This in-vitro study aimed to evaluate whether different deep margin elevation (DME) thicknesses (1 mm, 2 mm, 3 mm) influence the fracture resistance and fracture type of molars restored with CAD/CAM lithium disilicate overlays, compared to no elevation.

Methods: Seventy-six extracted human molars were randomly divided into four groups (n=19) based on Deep Margin Elevation thickness: 0 mm (control), 1 mm, 2 mm, and 3 mm. Standardized Class II cavities were prepared with cervical margins extending 1 mm below the cementoenamel junction. DME was performed using a low-viscosity hybrid composite. Using a CAD/CAM workflow, overlays were designed and milled …


The Effect Of Loading On The Success Of Dental Implants After Immediate Extraction Compared To Delayed Dental Implants: A Systematic Review, Hassen Merzouk, Samir Habibi, Ben Ali Boutabout Dec 2025

The Effect Of Loading On The Success Of Dental Implants After Immediate Extraction Compared To Delayed Dental Implants: A Systematic Review, Hassen Merzouk, Samir Habibi, Ben Ali Boutabout

International Arab Journal of Dentistry

Introduction: The study focuses on dental implants, which are used to replace missing teeth. A key decision in implant dentistry is when to place the implant relative to tooth extraction. This review compares two main approaches: immediate implant placement (placing the implant during the same surgery as tooth removal) and delayed implant placement (placing the implant after the extraction site has healed, typically 6 to 12 months later).

Objectives: The study aims to compare the success rates and complications associated with these two-timing strategies, especially concerning the implant’s ability to withstand chewing forces. The primary objective was to compare post-extraction …


The Impact Of Scan Spans On The Accuracy Of Three Intraoral Scanners: A Comparative Study, Lynn Labban, Louis Hardan, Cynthia Kassis Sep 2025

The Impact Of Scan Spans On The Accuracy Of Three Intraoral Scanners: A Comparative Study, Lynn Labban, Louis Hardan, Cynthia Kassis

International Arab Journal of Dentistry

Objectives: In modern dentistry, intraoral scanners (IOSs) have become indispensable tools for capturing accurate digital impressions of patients’ dentition, facilitating the design and fabrication of various dental restorations. However, the accuracy of these scanners can be influenced by factors such as scan span, which refers to the extent of the area scanned during impression taking. Understanding the impact of scan span on scanner accuracy is crucial for optimizing clinical outcomes and ensuring the reliability of digital models. The aim of this study was to evaluate and compare the accuracy, encompassing both trueness and precision, of intraoral scanners (IOSs) across different …


Comparison Of Treatment Outcome Of Occlusal Splints And Physiotherapy Regarding Their Effect On Posture: An In Vivo Pilot Study, Bouchra El Fassih, Amine El Zoghbi, Pascal El Braidy Jan 2025

Comparison Of Treatment Outcome Of Occlusal Splints And Physiotherapy Regarding Their Effect On Posture: An In Vivo Pilot Study, Bouchra El Fassih, Amine El Zoghbi, Pascal El Braidy

International Arab Journal of Dentistry

Objectives: The primary objective of the research is to assess occlusal splints and physical exercise effect on posture. The secondary objective is to compare which treatment option has more positive feedback regarding posture adjustment.

Methods: twenty patients with temporomandibular disorders (TMD) were divided into two groups equally, one receiving occlusal splints as a treatment for TMD and the other group receiving physical therapy exercises. They underwent a clinical and postural examination at baseline, after 1 week, after 1 month and after 2 months of treatment. Postural stability was assessed using a force platform (SATEL). Subjects were evaluated in …


Evaluation Of Microtensile Bond Strength Of Composite Under Three Aging Conditions: A Comparative In Vitro Study, Fadi Hammoud, Louis Hardan, Maryse Nassif, Tala El Ghoul, Georges Najjar, Cynthia Kassis Jan 2025

Evaluation Of Microtensile Bond Strength Of Composite Under Three Aging Conditions: A Comparative In Vitro Study, Fadi Hammoud, Louis Hardan, Maryse Nassif, Tala El Ghoul, Georges Najjar, Cynthia Kassis

International Arab Journal of Dentistry

Objectives: To investigate the effects of different in-vitro artificial aging protocols on the micro tensile bond strength (µTBS) of composite restorations applied to dentin.

Methods: A total of 88 teeth were prepared on dentin and divided into three distinct aging conditions and a control group : G1) Control group with no aging (n=22); G2) Thermal Cycling (Thermocycling) involving 10,000 cycles between 5°C and 55°C, with a dwell time of 20 seconds (n=22); G3) Mechanical Loading (Cyclic loading) with a 50 N load, a frequency of 1.5 Hz, and 10,000 cycles (n=22); G4) Combined Thermo-mechanical cyclic loading (TMCL) using …


Color Stability Of Conventional, 3d-Printed, And Milled Denture Teeth After Immersion In Coloring Agents: An In Vitro Study, Dany Nassif, Nancy Chemaly, Rim Bourgi, Carole Abi-Ghosn, Louis Hardan, Jihad Fakhouri Jan 2025

Color Stability Of Conventional, 3d-Printed, And Milled Denture Teeth After Immersion In Coloring Agents: An In Vitro Study, Dany Nassif, Nancy Chemaly, Rim Bourgi, Carole Abi-Ghosn, Louis Hardan, Jihad Fakhouri

International Arab Journal of Dentistry

Objectives: This study investigates the color stability of denture teeth made from different materials when subjected to various staining solutions.

Methods: Forty-five A1 shade upper central incisors were divided into three groups: prefabricated, 3D printed, and milled denture teeth (N=45). Each group was further divided into three subgroups, with teeth immersed in coffee, wine, and artificial saliva for up to 120 days (n=5). ∆E values for color change were measured using an Optishade colorimeter.

Results: The type of teeth, type of solution, and immersion time had a significant effect on color stability (p < 0.001). Interactions between the three variables were all significant (p < 0.001). Conventional denture teeth showed slight color changes with saliva (ΔE = 1.256 by day 120), moderate changes with wine (ΔE = 2.893), and more significant changes with coffee (ΔE = 5.208). Milled denture teeth exhibited no color changes with saliva, noticeable changes with wine (ΔE = 5.359), and moderate changes with coffee (ΔE = 3.137). 3D printed denture teeth showed no color changes with saliva, but increased changes with wine (ΔE = 2.533) and highly significant changes with coffee (ΔE = 10.546). Coffee consistently caused the highest ΔE values, especially in 3D printed teeth.

Conclusions: The study …


Comparative Evaluation Of Marginal And Internal Fit Of Zirconia Crown Designed Using Artificial Intelligence And Cad-Cam Software: A Systematic Review, Pritesh Gangde, Sweta Kale Pisulkar, Arushi Beri, Pritam Das Jan 2025

Comparative Evaluation Of Marginal And Internal Fit Of Zirconia Crown Designed Using Artificial Intelligence And Cad-Cam Software: A Systematic Review, Pritesh Gangde, Sweta Kale Pisulkar, Arushi Beri, Pritam Das

International Arab Journal of Dentistry

Introduction: The long-term performance of dental restorations depends on their internal and marginal fits. Improvements in the fit of restorations, especially zirconia crowns, have been investigated through the use of diverse materials, manufacturing processes, and impression techniques.

Objectives: The purpose of this review was to examine the internal and marginal fit of zirconia crowns made with CAD/CAM software with artificial intelligence (AI) software.

Methods: Using a combination of keywords and MeSH terms, the literature search was carried out across seven databases: PubMed, Scopus, Web of Science, Cochrane Library, Embase, ProQuest, and ScienceDirect from inception till 1st of …


Creating Smiles With Digital Workflow And Matrix Transfer Technique In Customizing Personality-Based Smile Designing, Jahnavi Purna Gorripati, Surekha Godbole Jan 2024

Creating Smiles With Digital Workflow And Matrix Transfer Technique In Customizing Personality-Based Smile Designing, Jahnavi Purna Gorripati, Surekha Godbole

International Arab Journal of Dentistry

Introduction: This report is a presentation of a clinical case that follows the Visagism concept for 2D planning and, CAD (Exo CAD) for 3D desiging along 3D printed diagnostic wax-up model for closure of anterior spacing.

Case presentation: A 24-year-old man presented with midline diastema and anterior spacing 11-13, 21-23 and wants a smile designed. This concern was solved following a smile design (VisagiSMile) planning digitally for diagnostic wax and printing a 3D model. The matrix transfer technique has been used to directly convey planned information from 3D-printed diagnostic wax-up to definitive restorations.

Conclusions: In this day …


Testing The Strength Of Thin Feather-Edge Monolithic Multilayered Zirconia Crowns: A Pilot Study With A Novel Acoustic Test, Estelle Saab, Camille Haddad, Maher Abboud, Maha Daou, Amine Zoghbi Jan 2024

Testing The Strength Of Thin Feather-Edge Monolithic Multilayered Zirconia Crowns: A Pilot Study With A Novel Acoustic Test, Estelle Saab, Camille Haddad, Maher Abboud, Maha Daou, Amine Zoghbi

International Arab Journal of Dentistry

Introduction: Limited research has explored the mechanical characteristics of recently introduced multilayered monolithic zirconia (MZC) crowns with feather-edge margins design. Moreover, most of the conventional techniques for evaluating the mechanical behavior of brittle dental ceramics rely on destructive tests, making it impossible to precisely evaluate real strength values due to premature crack initiation detection failure.

Objectives: The main objective of the study was to assess the load capacity of translucent multilayered monolithic zirconia crowns with feather-edge margin thicknesses of 0.4 mm and 0.5 mm. Additionally, the research introduced a novel non-destructive acoustic emission testing (AET) technique in the …


Investigation Of Fracture Resistance With Different Diameters Of Polyetherketoneketone Post And Core Materials: A Pilot Study, Maya Kabbara, Ryan Harouny, Habib Rahme Jan 2024

Investigation Of Fracture Resistance With Different Diameters Of Polyetherketoneketone Post And Core Materials: A Pilot Study, Maya Kabbara, Ryan Harouny, Habib Rahme

International Arab Journal of Dentistry

Objectives: The primary objective of this study is to investigate the resistance to fracture of Polyetherketoneketones PEKK, used as post and core by fabrication in different diameters in the canal, and comparing the test results for each group.

Methods: Thirty extracted mandibular premolars were selected, endodontically treated and prepared to receive the post and cores milled from polyetherketoneketone disk. The specimens were randomly divided into five groups (n = 6) respectively: group 1 received pekk post with diameter = 0.70 mm, group 2 received pekk post with diameter = 0.90 mm, group 3 received pekk post with diameter …


Comparison Of The Failure Between Conventional Pmma And Milled Pmma Full Arch Maxillary Interim Prosthesis Fixed On 4 Implants: An In Vitro Study, Tatiana Bou Sakr, Hani Tohme, Natalia Bou Sakr, Victor Ghoubril, Carole Abi Ghosn Yared Jan 2024

Comparison Of The Failure Between Conventional Pmma And Milled Pmma Full Arch Maxillary Interim Prosthesis Fixed On 4 Implants: An In Vitro Study, Tatiana Bou Sakr, Hani Tohme, Natalia Bou Sakr, Victor Ghoubril, Carole Abi Ghosn Yared

International Arab Journal of Dentistry

Objectives: The principal objective of this study was to compare the failure load between the conventional heat polymerized PMMA and the CAD/CAM milled PMMA interim full arch implant prostheses. The secondary aim was to evaluate the success of the distal extension of the temporary PMMA prosthesis.

Methods: A metallic edentulous upper arch model with 4 Straumann screw-retained abutment digital analogs was used to create 15 specimens for each of the 2 groups: Conventional and milled. Failure load was measured on 5 different regions on the left and right side of each specimen with the YLE universal testing machine: …


Endocrown, From Preparation To Bonding: Case Report, Amira Yousfi, Rihab Dakhli, Jilani Saafi, Belhassen Harzallah Jan 2024

Endocrown, From Preparation To Bonding: Case Report, Amira Yousfi, Rihab Dakhli, Jilani Saafi, Belhassen Harzallah

International Arab Journal of Dentistry

The restoration of endodontically treated teeth is a real challenge, particularly teeth with extensively damaged coronal tissues. The use of post-retained restorations has been discussed because of the potential tooth weakening due to the additional removal of sound dental structures. In fact, long-term prognosis of a devitalized tooth is closely related to the coronal restoration’s quality and the remaining dental structure. With the development of adhesive dentistry and minimally invasive preparation, new approaches have emerged. Among them, the endocrown which is monolithic ceramic bonded restoration, anchored to the internal portion of pulp chamber and cavity margins that have been used …


Analysis Of Changes In Gingiva-Occlusal Parameters As Perceived By Three Middle-East Populations, Nadine Nachabeh, Tony Daher, Elie Maalouf, Khalil Kharma, Eliane Kaydouh, Carina Mehanna May 2023

Analysis Of Changes In Gingiva-Occlusal Parameters As Perceived By Three Middle-East Populations, Nadine Nachabeh, Tony Daher, Elie Maalouf, Khalil Kharma, Eliane Kaydouh, Carina Mehanna

International Arab Journal of Dentistry

Purpose. This study aims to compare the effect of various smile parameters (buccal corridor, gummy smile, midline to face discrepancy, with and without upper lip filling) on the perception of smile attractiveness by applying the digital modification of images judged by one hundred and eighty laypersons from different Middle East populations.

Materials and Methods. A frontal photo of a woman’s smile is manipulated with Photoshop to modify each smile parameter gradually into 3 grades. The total number of smiles to be assessed is 18. One hundred and eighty participants divided into 3 groups (n=60: 30 men and 30 women): …


Distal Cantilever Length Comparison In Esthetic Materials For Hybrid Implant Prostheses: An In Vitro Study, Sana Shams Eddin, Elie Jasser, Mohammad Chams Eddin, Carole Abi Ghosn Yared, Joseph Makzoumi, Paul Boulos May 2023

Distal Cantilever Length Comparison In Esthetic Materials For Hybrid Implant Prostheses: An In Vitro Study, Sana Shams Eddin, Elie Jasser, Mohammad Chams Eddin, Carole Abi Ghosn Yared, Joseph Makzoumi, Paul Boulos

International Arab Journal of Dentistry

Objective: the assessment of distal cantilever length in implant supported prothesis (Hybrid prosthesis) by comparing the load to fracture in two different esthetic framework materials (Zirconia and Polyetheretherketone (PEEK)) with two different cantilevers loading distances (10mm, 15mm).

Material and methods: 20 frameworks were fabricated and divided into 4 groups (n=5): according to the material type, Peek, zirconia, and according to the cantilever loading distance (10), or (15) mm and a load-to-fracture test was used until complete fracture of specimens occurs.

Results: The effect of material type and cantilever loading distance were statistically significant for the mean load-to-fracture …


Orofacial Esthetic Scale (Oes) And Psychosocial Impact Of Dental Aesthetic Questionnaire (Pidaq): Development And Psychometric Properties Of Central Indian Version, Gunjan Taori, Amit Reche, Chinmayee Dahihandekar, Kaustubh Mantri, Neshant Rathi Jan 2023

Orofacial Esthetic Scale (Oes) And Psychosocial Impact Of Dental Aesthetic Questionnaire (Pidaq): Development And Psychometric Properties Of Central Indian Version, Gunjan Taori, Amit Reche, Chinmayee Dahihandekar, Kaustubh Mantri, Neshant Rathi

International Arab Journal of Dentistry

Background: Orofacial Esthetic Scale (OES) is used to test psychometric properties of Indian population and Indian version of Psychosocial Impact of Dental Aesthetic Questionnaire (PIDAQ) for psychometric evaluation. The aim of this study is to develop Orofacial Esthetic Scale (OES) in Indian version, to test psychometric properties of individuals in the cultural environment in central India.

Materials and methods: A hospital based cross sectional study was done, where altogether 30 questions were asked to patients, their relatives and to dentists. 8 questions were related to Orofacial Esthetics Scale (OES) whereas 22 pertaining to Psychosocial Impact of Dental Aesthetic …


Influence Of The Margin Design On The Fracture Resistance Of Implant Supported Monolithic Zirconia Crowns: An In Vitro Study, Camille Haddad, Ryan Harouny, Karim Corbani, Lara Nasr, Ronn Tassidis Jan 2023

Influence Of The Margin Design On The Fracture Resistance Of Implant Supported Monolithic Zirconia Crowns: An In Vitro Study, Camille Haddad, Ryan Harouny, Karim Corbani, Lara Nasr, Ronn Tassidis

International Arab Journal of Dentistry

Introduction: The purpose of this in vitro study was to test the influence of the margin design of implant supported monolithic zirconia crowns and test if monolithic zirconia crowns with extra fine finish line thickness cemented on zirconia implant abutments can bare the maximum masticatory forces on molars and hence be used in the posterior region.

Methods: Fourteen identical monolithic zirconia crowns cemented on zirconia implant abutments mounted on titanium bases and fixed on implant replicas embedded in PMMA resin were divided into two groups: group I designed with a 0.5 mm CFL (CFL) and group II with …


Rehabilitation Of A Patient With Single Complete Tooth-Supported Overdenture Against The Unmodified Natural Dentition Using Functionally Generated Path Technique: A Case Report, Akanksha Shinde, Nilesh Bulbule, Varun Bhatt, Gayathri Balachandran, Amit Jagtap Jan 2023

Rehabilitation Of A Patient With Single Complete Tooth-Supported Overdenture Against The Unmodified Natural Dentition Using Functionally Generated Path Technique: A Case Report, Akanksha Shinde, Nilesh Bulbule, Varun Bhatt, Gayathri Balachandran, Amit Jagtap

International Arab Journal of Dentistry

Meyer’s proposed chew-in technique also called functionally generated path (FGP) technique, is indicated for the restoration of an edentulous arch that is opposed by natural teeth as it does seem to provide the most accurate method of recording occlusal patterns, also help to minimize the effects of negative factors, and to overcome the deficiencies of articulators. As stated by Rudd and Morrow, this technique is especially suitable for tooth-supported complete dentures, due to inherent stability of tooth-supported record bases helps in recording jaw relationships accurately. Whenever a single complete denture is opposed by natural dentition, problems observed are abrasion of …


Oral Health Of Completely Edentulous Patients During The Covid-19 Pandemic And Its Impact On Their Nutritional Status: A Pilot Study, Hayat Jaber, Elissa Haddad, Carole Abi Ghosn Yared, Jihad Fakhouri, Nada El Osta Nov 2022

Oral Health Of Completely Edentulous Patients During The Covid-19 Pandemic And Its Impact On Their Nutritional Status: A Pilot Study, Hayat Jaber, Elissa Haddad, Carole Abi Ghosn Yared, Jihad Fakhouri, Nada El Osta

International Arab Journal of Dentistry

The COVID-19 pandemic, declared by the WHO on May 2020, has forced governments around the world to adapt several restrictive measures causing difficulties of access to oral healthcare. In Lebanon, a lack of data on these difficulties and their consequences for completely edentulous people prompted the realization of a pilot study evaluating the impact of this pandemic on access to oral healthcare and on the oral health status, oral health-related quality of life (OHRQoL), and nutritional status of these individuals. The study was conducted at the Removable Prosthodontics Department of the Faculty of Dentistry at Saint-Joseph University of Beirut through …


Prosthetic Management Of Interruptive Mandibular Defects, Saloua Hamzaoui, Mohamed Azhari, Hasnaa Rokhssi, Majid Sakout, Oussama Bentahar Nov 2022

Prosthetic Management Of Interruptive Mandibular Defects, Saloua Hamzaoui, Mohamed Azhari, Hasnaa Rokhssi, Majid Sakout, Oussama Bentahar

International Arab Journal of Dentistry

Mandibular substance loss is one of the most frequent acquired defects of the maxillofacial mass. Several etiologies have been described, the most frequent of which are tumours and traumas. The most commonly used prosthetic classification takes into consideration the bone continuity of the mandible, thus there are marginal defect mandibular substance preserving bone continuity and segmental defect with basal bone discontinuity. These bone defects lead to numerous functional complications (loss the dental occlusion, decreased chewing efficiency, lack of stalling during swallowing, phonatory disorder related to the change in the buccal resonance cavity) and aesthetic complications (facial asymmetry due to lateral …


Effect Of Impression Techniques On Soft Tissue Vertical Displacement In Removable Partial Denture. A Pilot Study, Christine Hanna, Nada El Osta, Jihad Fakhouri Nov 2022

Effect Of Impression Techniques On Soft Tissue Vertical Displacement In Removable Partial Denture. A Pilot Study, Christine Hanna, Nada El Osta, Jihad Fakhouri

International Arab Journal of Dentistry

Abstract Purpose: The purpose of this study was to evaluate the vertical displacement of soft tissue during different impression procedures using various spacing of the custom tray, and to determine which impression technique would allow the minimal movement. Material and Methods: 21 partially edentulous subjects were selected and enrolled in the study. Each one of them was subjected to four different impression procedures: three alginate impressions with different spacing of the custom tray and one composed with different impression materials, then casts were constructed. Light-curing acrylic occlusal platform was constructed on the primary model and perforated in 10 different points. …