Enhanced Periodontal Ligament Stem Cell Viability And Osteogenic Differentiation On Two Implant Materials: An Experimental In Vitro Study, Sara Fikry, Shereen Nader Dr, Engy Farag Dr Apr 2023

Enhanced Periodontal Ligament Stem Cell Viability And Osteogenic Differentiation On Two Implant Materials: An Experimental In Vitro Study, Sara Fikry, Shereen Nader Dr, Engy Farag Dr

Dentistry

Background: Surface roughness of dental implants impacts the survival of adult periodontal stem cells and rate of differentiation. This research was conducted to test how human periodontal ligament stem cells behaved on yttria stabilized tetragonal zirconia polycrystals and polyetheretherketone (PEEK) discs with different surface topographies. Methods: Discs roughening was prepared by sandblasting. Stem cells were cultivated on zirconia discs with a polished surface, PEEK discs with a polished surface, sandblasted zirconia discs and sandblasted PEEK discs. Cells viability was assessed after 24, 48, 72 hours. Scanning electron microscopy was used to examine the adherence and attachment of cells. Osteoblastic differentiation …


Osseointegrated Implants Versus Zirconium Mucosal Inserts In Complete Denture Patients, Sara Fikry El Shafei Dr, Fardos N Rizk Jan 2019

Osseointegrated Implants Versus Zirconium Mucosal Inserts In Complete Denture Patients, Sara Fikry El Shafei Dr, Fardos N Rizk

Dentistry

Purpose: To evaluate the effect of osseointegrated implants versus mucosal inserts used for retention of complete dentures. Materials and Methods: Twelve completely edentulous patients were selected for this study and divided into two groups of six. Group I received implant retained maxillary overdentures, while group II received maxillary overdentures retained by muchor zirconium mucosal inserts. Bone changes in both groups were evaluated using cone beam ct at insertion and after six and twelve months. Results: The results showed that the bone changes produced in mucosal overdenture wearers were greater than those produced in implant overdenture wearers. Conclusion: Zirconium mucosal inserts …


Comparing The Vertical Misfit Of Casts Produced By Two Verification Jigs, Abdulaziz Saeed Alqahtani Jul 2014

Comparing The Vertical Misfit Of Casts Produced By Two Verification Jigs, Abdulaziz Saeed Alqahtani

Master's Theses (2009 -)

Purpose: To compare the dimensional accuracy between master casts fabricated with verification jigs made of acrylic resin and light cure Triad. Materials and Methods: 10 GC Pattern resin Pattern verifications jigs and 10 Triad gel verification jigs fabricated of a master cast of a mandibular model of 4 internal hex implants. A stone base was fabricated for each verification jig. One screw test was used to evaluate the vertical gap at the terminal abutment using a digital micrometer with an accuracy of 1μm to record the vertical gap for each sample. Results: Triad Gel group has the lowest average distortion …


Effect Of Two Different Attachments On The Supporting Structures And Masticatory Capacity Of Implant Retained Mandibular Overdenture, Fardos N. Rizk Apr 2014

Effect Of Two Different Attachments On The Supporting Structures And Masticatory Capacity Of Implant Retained Mandibular Overdenture, Fardos N. Rizk

Dentistry

Aim: This study was conducted to compare the effect of ball and socket attachment and GPS attachment in implant retained mandibular overdenture cases regarding changes in: crestal bone height and density surrounding implants, electromyographic activity of temporalis and masseter muscles and occlusal biting force. Materials and Methods: Following two stage surgical protocol twelve completely edentulous patients received two implants placed bilaterally in the canine region (24 implants) to retain mandibular overdenture. Four months following the surgery patients were randomly divided into two equal groups; Group-I received ball and socket attachment while Group-II received GPS attachment upon which mandibular overdentures were …


Comparative Evaluation Of Two Different Castable Bar Attachments In Implant Retained Mandibular Overdenture Cases, Fardos N. Rizk Jul 2013

Comparative Evaluation Of Two Different Castable Bar Attachments In Implant Retained Mandibular Overdenture Cases, Fardos N. Rizk

Dentistry

Objective: This research was carried to evaluate which solitary attachment; OT Cap Ball attachment or OT Cap Equator Profile attachment mounted on a bar splinting two implants retaining mandibular overdenture is more favorable regarding crestal bone height and bone density changes surrounding the implants using cone beam computed tomography. Materials and Methods: Following two stage surgical protocol twelve completely edentulous patients received two implants placed bilaterally in the canine region (24 implants) to retain mandibular overdenture. Four months following the surgery patients were randomly divided into two equal groups; Group-I received two OT Cap Ball attachments mounted on a bar …


Effect Of Two Different Implant Structures On Stresses Induced Within The Surrounding Bone Using Three Dimensional Finite Element Analysis, Fardos N. Rizk Apr 2012

Effect Of Two Different Implant Structures On Stresses Induced Within The Surrounding Bone Using Three Dimensional Finite Element Analysis, Fardos N. Rizk

Dentistry

objective: The purpose of this study is to compare the stresses induced within the bone surrounding the Trabecular Metal Dental Implant (Zimmer Dental Inc., Carlsbad, CA, USA) in comparison to the stresses induced within the bone surrounding its predicate Tapered Screw Vent Implant (Zimmer Dental Inc., Carlsbad, CA, USA) using three dimensional finite element analysis. materials and methds: The current finite element analysis simulated a clinical situation where an edentulous mandible was restored with an entirely implant supported cantilever bar overdenture retained by five implants placed parallel to each other in the interforaminal region opposed by a complete denture. Two …


Comparative Study Of Ot Equator Profile Attachment Versus Gps Attachment In Implant Retained Mandibular Overdenture Cases, Fardos N. Rizk Jan 2012

Comparative Study Of Ot Equator Profile Attachment Versus Gps Attachment In Implant Retained Mandibular Overdenture Cases, Fardos N. Rizk

Dentistry

Aim: This study was carried out to evaluate whether OT Equator Profi le attachment or GPS attachment is less destructive to crestal bone around implants and to bone in distal aspect of the ridge in implant retained mandibular overdenture cases. Materials and Methods: Following two stage surgical protocol twelve completely edentulous patients received two implants placed bilaterally in the canine region (24 implants) to retain mandibular overdentures. Four months following the surgery patients were randomly divided into two equal groups; Group-I received OT Equator Profi le attachment while Group-II received GPS attachment upon which mandibular overdentures were retained. Once patients …


Radiodensitometric Evaluation Of The Effect Of Low Energy Laser Irradiation With And Without Anioxidant Therapy On Immediately Loaded Implant Supported Overdenture, Fardos N. Rizk, Mouchira Salah Eldin Prof. Oct 2011

Radiodensitometric Evaluation Of The Effect Of Low Energy Laser Irradiation With And Without Anioxidant Therapy On Immediately Loaded Implant Supported Overdenture, Fardos N. Rizk, Mouchira Salah Eldin Prof.

Dentistry

objective: The purpose of this study is to compare the bone height and density around immediately loaded implants placed in the canine area supporting a mandibular overdenture in four different groups. The first group received low level laser therapy and antioxidants. The second group received antioxidants only. The third group received low level laser therapy only. The fourth group (control group) received no therapy. materials and methods: Following one stage surgical protocol twenty four implants were inserted bilaterally in the canine region to support mandibular overdentures for twelve completely edentulous patients in the form of two implants per patient. Patients …


Hyperbaric Oxygen Therapy For Promoting Osseointegration Around Dental Implants In Heavy Smokers, Fardos N. Rizk, Nasser Shaheen Jul 2011

Hyperbaric Oxygen Therapy For Promoting Osseointegration Around Dental Implants In Heavy Smokers, Fardos N. Rizk, Nasser Shaheen

Dentistry

Objective: The purpose of this study is to evaluate the effect of hyperbaric oxygen (HBO) therapy on osseointegration of implants supporting mandibular overdenture in heavy smokers. Materials and Methods: Following two stage surgical protocol twelve completely edentulous male heavy smokers received implants placed bilaterally in the canine region to support mandibular overdenture. On the second day after the surgery patients were divided randomly into two equal groups. Patients of group I were placed on a protocol of five consecutive sessions of HBO therapy, while patients of group II received no therapy and served as control. Four months following the surgery …


Evaluation Of Osseointegration Between Two Different Modalities Of Hydroxyapatite Implant Surface Coatings: Plasma Sprayed Ha Coated Implants And Electrophoresis Deposited Nano Ha Coated Implants, Audrey Marie Selecman May 2007

Evaluation Of Osseointegration Between Two Different Modalities Of Hydroxyapatite Implant Surface Coatings: Plasma Sprayed Ha Coated Implants And Electrophoresis Deposited Nano Ha Coated Implants, Audrey Marie Selecman

Theses and Dissertations (ETD)

Purpose: The objective of this study was to evaluate the osseointegration between plasma sprayed (PS) hydroxyapatite (HA) coated implants and electrophoresis deposited (EPD) nano hydroxyapatite coated implants in an animal model. The quantity of osseointegration was inferred by interfacial strength and percent tissue-contact length.Materials and Methods: Thirty-six cylindrical implants (18 PS and 18 EPD) were placed into dog mandibles. Nine implants from each group were evaluated with pull out testing and histological studies at 12 weeks after implantation. The remaining implants were occlusally loaded for 9 months and then evaluated by pull out testing and histological studies.Results: Twelve weeks after …