Open Access. Powered by Scholars. Published by Universities.®

Prosthodontics and Prosthodontology Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Prosthodontics and Prosthodontology

Pterygoid Implant-Retained Bridge Following Multiple Failed Alveolar Implants In Posterior Maxilla, Kouder Dakhallah Dds, Anish Gupta Dds, Joey Wilmot, Brian Giammalva Dds Apr 2025

Pterygoid Implant-Retained Bridge Following Multiple Failed Alveolar Implants In Posterior Maxilla, Kouder Dakhallah Dds, Anish Gupta Dds, Joey Wilmot, Brian Giammalva Dds

The Journal of the Michigan Dental Association

The replacement of multiple teeth with dental implants in the posterior maxilla is challenging due to factors including low density bone and sinus morphology. When considering restoration of this region, prosthetic design will dictate implant placement. Additionally, planning must consider spacing between adjacent implants, spacing between implants and adjacent teeth, and irregular alveolar ridge morphology. These key measurements translate to the final prosthesis design and will affect cleanability and future oral hygiene maintenance. These characteristics subsequently affect overall longevity of the implants and prosthesis.

In the following case, multiple closely-placed implants presenting with poor cleanability consequently failed, requiring removal and …


Fabrication Of Implant Supported Hybrid Denture Using Multi-Unit Abutments In A Patient With Generalised Aggressive Periodontitis, Anupama Aradya, Raghavendra Swamy K N, Chandan S N, Prashanth M B Oct 2024

Fabrication Of Implant Supported Hybrid Denture Using Multi-Unit Abutments In A Patient With Generalised Aggressive Periodontitis, Anupama Aradya, Raghavendra Swamy K N, Chandan S N, Prashanth M B

International Journal of Health and Allied Sciences

This case report describes the prosthodontic rehabilitation of a geriatric patient with generalized aggressive periodontitis. The patient was advised to for full extraction. An implant supported hybrid prosthesis with multi-unit abutments was fabricated for the patient who chose a fixed kind of prosthesis. Implants were placed in the maxillary & mandibular arch. Frameworks were waxed, plastic castable abutments were used for casting, denture teeth were waxed to the hybrid framework and a final wax try-in to check and adjust the maxilla-mandibular relationships before processing, the prosthesis was placed. The clinical and radiologic results met expectations.


Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, [email protected], Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, [email protected], Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, [email protected] Jan 2024

Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, [email protected], Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, [email protected], Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, [email protected]

Future Dental Journal

Background: Several treatment options are planned for completely edentulous patients rehabilitation which were developed to meet patients desires and requirements, starting from conventional complete denture till implant supported fixed full arch cases. Each technique has its own indication and limitations. Passive fit is an important factor for the long-term success of implant- prosthesis, which necessitate accurate transfer of the implant position. Recently, digital impressions have been introduced in dental implant treatment. By the use of scan body and different optical scanning methods, the position of scan bodies can be transferred to a virtual implant position within the dental arch. Material …


Comparison Between Two Different Attachment Caps Used In Locator Attachments Of Implant Supported Overdentures (In-Vitro Study), Hossam Eldein Faisal Haridy, Hebatalla Mahmoud El Afandy, Mohammed Farouk Abdalla, Ahmed Mohammed Osama Jun 2022

Comparison Between Two Different Attachment Caps Used In Locator Attachments Of Implant Supported Overdentures (In-Vitro Study), Hossam Eldein Faisal Haridy, Hebatalla Mahmoud El Afandy, Mohammed Farouk Abdalla, Ahmed Mohammed Osama

Future Dental Journal

Purpose: To compare different retentive cap material used in LOCATOR attachments, namely the nylon retentive cap versus PEEK retentive caps, and measure the loss of retention over a period of two years, through 2880 cycles of insertion and removal. Materials and methods: Two implants 3.8mm x 10.5mm were inserted into a clear epoxy resin cast, through a surgical guide, with the implants being 23mm apart. Two LOCATOR attachments with 5 mm gingival height were screwed to the implants, custom made nylon caps were fabricated as an exact replica of the PEEK retentive caps, then two dentures were constructed …


Peri-Implantitis Incidence And Effect Of Supportive Periodontal Therapy On Outcomes: Retrospective Cohort Study, Michael Ha Jan 2022

Peri-Implantitis Incidence And Effect Of Supportive Periodontal Therapy On Outcomes: Retrospective Cohort Study, Michael Ha

Theses and Dissertations

Purpose: Management of peri-implantitis is becoming an increasing component of dental practice. Dental implants can develop peri-implantitis lesions which occur in a non‐linear and accelerating pattern compared to a gradual periodontitis lesion. It is crucial to diagnose and treat this disease early, or ideally prevent it. Contemporary implants have a rough surface texture which is difficult to properly decontaminate as a crucial component for treatment prognosis. Evidence on the long-term effects of Periodontal implant maintenance therapy (PIMT) on implants is limited. This study aims to investigate the effect of periodontal maintenance on peri-implant tissue health.

Methods: A retrospective chart review …


Comparison Of Implant-Retained Overdenture And Conventional Complete Denture In The Edentulous Mandible: A Survey Study To Measure Patients' Satisfaction And Quality Of Life In Dental School Clinical Environment, Ahmad Kutkut Jan 2021

Comparison Of Implant-Retained Overdenture And Conventional Complete Denture In The Edentulous Mandible: A Survey Study To Measure Patients' Satisfaction And Quality Of Life In Dental School Clinical Environment, Ahmad Kutkut

Theses and Dissertations--Clinical and Translational Science

Patient satisfaction and quality of life are integral parts of assessing the quality of oral health care. Current aging population trends suggest a growing need to understand the effects of edentulism on oral health and quality of life. As the proportion of aged Americans expands, there will be an increased need to understand treatment options and patient communication strategies. In addition, as new treatment options and innovative technologies emerge, it will be essential to understand patients' concerns and identify best practices associated with denture treatments' individual fit and function. Advanced denture treatments can now be fabricated using CAD/CAM digital denture …


Accuracy Of Digital Impressions At Varying Implant Depths: An In-Vitro Study, Vivia Sequeira Jan 2021

Accuracy Of Digital Impressions At Varying Implant Depths: An In-Vitro Study, Vivia Sequeira

Graduate Theses, Dissertations, and Problem Reports (ETD)

Introduction: Implants placed at variable depths may vary the amount of visible scannable surface of a scan body. Intraoral scanner technology uses advanced optical principles to record the surface of the scan body to accurately capture the implant position.

Purpose: To investigate the effect implant placement depth has on the accuracy of digital implant impressions using an intraoral scanner.

Materials & Methods: A partially edentulous gypsum master model was fabricated to allow the positioning of a single implant analog at different depths. Four groups based on the planned implant depths of 0, 3, 6 and 7mm and corresponding visibility of …


Stress Analysis Comparing Effect Of Two Different Cad-Cam Implant Superstructure Materials (In-Vitro Study), Noura Turky Saad, Essam Osman, Ahmed M. Abdelhamid, Mohamed Shokry, Ehab A. Farghaly Nov 2020

Stress Analysis Comparing Effect Of Two Different Cad-Cam Implant Superstructure Materials (In-Vitro Study), Noura Turky Saad, Essam Osman, Ahmed M. Abdelhamid, Mohamed Shokry, Ehab A. Farghaly

BAU Journal - Creative Sustainable Development

Purpose: This study was conducted to evaluate the micro-strain around dental implant using two different CAD/CAM crown fabricated materials through strain gauge analysis. Materials and Methods: Five dental implants were fixed in a 5 previously drilled solid rigid polyurethane test blocks in the edentulous area with neighboring abutments mesial and distal printed out using special 3D Dental printer, Cyanoacrylate adhesive was then used to fix the printed-out part on to the polyurethane test blocks, creating the bounded saddle replicas. Ten CAD/CAM screw retained crowns were fabricated; five Enamic crowns from vita enamic blocks, and five zirconia crowns from presintered katana …


A Comparative Evaluation Of Locator Versus Ball And Socket Attachment In Implant Retained Mandibular Overdenture Cases Using Cbct, Fardos N. Rizk, Marwa Sabet Prof., Amany Elhadary, Wael Amer Oct 2010

A Comparative Evaluation Of Locator Versus Ball And Socket Attachment In Implant Retained Mandibular Overdenture Cases Using Cbct, Fardos N. Rizk, Marwa Sabet Prof., Amany Elhadary, Wael Amer

Dentistry

No abstract provided.