Open Access. Powered by Scholars. Published by Universities.®
Prosthodontics and Prosthodontology Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Institution
- Publication
- Publication Type
Articles 1 - 9 of 9
Full-Text Articles in Prosthodontics and Prosthodontology
Effect Of Dynamic Fatigue Loading On The Adaptation And Retention Of Maxillary Single Dentures Reinforced With Digitally Constructed Zirconia And Cobalt–Chromium Frameworks, Ghada Elgindy, Fardos N Rizk, Marwa Ezzat Sabet, Hebatallah Tarek Mohamed
Effect Of Dynamic Fatigue Loading On The Adaptation And Retention Of Maxillary Single Dentures Reinforced With Digitally Constructed Zirconia And Cobalt–Chromium Frameworks, Ghada Elgindy, Fardos N Rizk, Marwa Ezzat Sabet, Hebatallah Tarek Mohamed
Dentistry
Background. The impact of dynamic fatigue loading on denture adaptation and retention is clinically important. Zirconia and cobalt–chromium (Co–Cr) frameworks enhance denture strength, but their performance under cyclic loading remains unclear. Objectives. The aim of the study was to evaluate the adaptation and retention of maxillary single dentures reinforced with digitally constructed Co–Cr or zirconia frameworks after a simulated 1 year of function. Material and methods. Three types of maxillary single dentures were constructed on maxillary master casts. Group A included maxillary dentures without reinforcement (control group), whereas groups B and C encompassed maxillary dentures reinforced with digitally designed and …
Biomechanicalperformanceofimplant-Tooth-Supportedprostheses:Anumerical3dfiniteelementanalysis, Basma Refaat Fayad, Islam Heiba Dr, Al Hassan Diab
Biomechanicalperformanceofimplant-Tooth-Supportedprostheses:Anumerical3dfiniteelementanalysis, Basma Refaat Fayad, Islam Heiba Dr, Al Hassan Diab
Dentistry
Objective:Toassessthebiomechanicalbehaviourofimplant-tooth-supported(hybrid)pros-theses,comparedwithanimplant-implant-supportedprosthesis,utilisingtwodifferentprostheticmaterials,employingfiniteelementanalysis(FEA).Method:Threedigitalmodels,derivedfromaCBCT-scannededentulousmandible,weredesigned:twohybridconfigurations(M1:distalimplant-firstpremolar;M2:mesialimplant-firstmolar)andanimplant-implant-supportedprosthesis(M3).Abiomechanicalmodellingworkflowwascarriedout(Mimicsforsegmentation,3-Maticforbone/mucosallayerrefinement,ExocadDentalCADandSolidWorksforimplants,abutmentandprosthe-sisintegration,andANSYSformeshingandFEA).Assumingisotropic/elasticmaterialproperties,zirconiaandpolyetherketoneketone(PEKK)wereselectedasprostheticmateri-als.Modelsweresubjectedtoastaticverticalload(100N).vonMisesstressandtotaldefor-mationwereanalysedtoevaluatestructuralresponses.Results:M3demonstratedthemostfavourablebiomechanicalprofile,exhibitingthelowestvonMisesstressmagnitudesalongsidethehighestoveralldeformation.Inhybridmodels(M1,M2),stressmaximawerelocalisedatthepontic−toothconnectorregionsand,inM1-PEKK,reached261MPainthescrew.Corticalboneandpreparedteethexhibitedhigherstressindis-tallyanchoredhybridsystems(M1)comparedtomesiallysupporteddesigns(M2),regardlessoftheprostheticmaterial.Comparativeanalysisrevealedthatzirconia-basedprosthesesgen-eratedhigherstressconcentrationsinbone(≤35MPa)comparedtoPEKK,whereasthePEKKprosthesisitselfexhibitedgreaterstructuraldeformation(70mminM1-PEKK).Conclusion:Hybridimplant-tooth-supportedprosthesescanactasareliablealternativetoimplant-implantonesandeliminatecantileverextensions;however,theiruseshouldbereservedforcarefullyselectedcasestoavoidbiomechanicalincompatibilities.
Effect Of Two Different Intraoral Polishing Systems On Surface Roughness, Color Stability, And Bacterial Accumulation Of Zirconiareinforced Lithium Silicate Ceramic, Fatma Makkeyah, Dina Mohamed Mostafa, Griffith University - Australia, Mahmoud Al Ankily
Effect Of Two Different Intraoral Polishing Systems On Surface Roughness, Color Stability, And Bacterial Accumulation Of Zirconiareinforced Lithium Silicate Ceramic, Fatma Makkeyah, Dina Mohamed Mostafa, Griffith University - Australia, Mahmoud Al Ankily
Dentistry
No abstract provided.
The Effect Of Die Material On The Crown Fracture Strength Of Zirconia Crowns, Akram Sayed Ahmed, Nathaniel C. Lawson, Chin-Chuan Fu, Pranit V. Bora, Edwin Kee, Amir H. Nejat
The Effect Of Die Material On The Crown Fracture Strength Of Zirconia Crowns, Akram Sayed Ahmed, Nathaniel C. Lawson, Chin-Chuan Fu, Pranit V. Bora, Edwin Kee, Amir H. Nejat
School of Dentistry Faculty Publications
BACKGROUND: Determination of the eligibility of several tooth analog materials for use in crown fracture testing. METHODS: A standardized premolar crown preparation was replicated into three types of resin dies (C&B, low modulus 3D printed resin; OnX, high modulus 3D printed resin composite; and highest modulus milled resin composite). 0.8 mm zirconia crowns were bonded to the dies and the maximum fracture load of the crowns was tested. Twelve extracted human premolars were prepared to a standardized crown preparation, and duplicate dies of the prepared teeth were 3D printed out of C&B. Zirconia crowns were bonded to both the dies …
Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, [email protected], Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, [email protected], Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, [email protected]
Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, [email protected], Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, [email protected], Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, [email protected]
Future Dental Journal
Aim this in vitro study was conducted to evaluate the effect of mechanical loading on different implant materials on supporting structures materials and methods: a total of three implant retained overdentures were used in this study, retained by two implants each (Titanium, polyetheretherketon and zirconia) were placed in epoxy resin casts at the canine area using a surgical guide. Soft liner material was used at the distal extension area to mimic the soft tissues. Two linear strain gauges were bonded buccal and lingual to each implant to measure the peri-implant strains during unilateral and bilateral loading. Results: during bilateral loading …
Enhanced Human Periodontal Ligament Stem Cell Viability And Osteogenic Differentiation On Two Implant Materials: An Experimental In Vitro Study, Engy Adel Ahmed Farag, Sara Fikry Dr, Shereen N. Raafat
Enhanced Human Periodontal Ligament Stem Cell Viability And Osteogenic Differentiation On Two Implant Materials: An Experimental In Vitro Study, Engy Adel Ahmed Farag, Sara Fikry Dr, Shereen N. Raafat
Dentistry
Background: Surface roughness of dental implants impacts the survival of adult periodontal stem cells and rate of differentiation. This research was conducted to test how human periodontal ligament stem cells behaved on yttria stabilized tetragonal zirconia polycrystals and polyetheretherketone (PEEK) discs with different surface topographies.
Methods: Discs roughening was prepared by sandblasting. Stem cells were cultivated on zirconia discs with a polished surface, polyetheretherketone (PEEK) discs with a polished surface, sandblasted zirconia discs and sandblasted polyetheretherketone (PEEK) discs. Cells viability was assessed after 24, 48, 72 hours. Scanning electron microscopy was used to examine the adherence and attachment of cells. …
A Comparison Between The Effect Of Different Pressures Of Air Particle Abrasion Before And After Sintering With And Without Zirconia Liner On Bond Strength Of Resin To Zirconia Surface, Lina Mohamad Saadeh, Ehab A. Farghaly, Mohammad M. Rayyan, Essam Osman
A Comparison Between The Effect Of Different Pressures Of Air Particle Abrasion Before And After Sintering With And Without Zirconia Liner On Bond Strength Of Resin To Zirconia Surface, Lina Mohamad Saadeh, Ehab A. Farghaly, Mohammad M. Rayyan, Essam Osman
BAU Journal - Creative Sustainable Development
This study aimed to compare the effect of different pressures of air particle abrasion 2 and 4 bars before and after sintering with and without zirconia liner on SBS of resin to zirconia Surface. Materials and Methods: 54 zirconia cuboids 8×8×3 mm were milled and divided into 6 equal groups (N=9) according to surface treatment; sintered with ceramic liner application and 2 bars pressure (SL2) and with 4 bars pressure (SL4), sintered with no ceramic liner and 2 bars pressure (SN2) and 4 bars pressure (SN4), unsintered with no ceramic liner and 2 bars pressure (UN2) and 4 bars pressure …
Effect Of Artificial Aging On Hardness And Surface Roughness Of Two Types Of Zirconia, Ramy Hamed Elsherif, Mona Hossam El-Din Mandour, Rania A. Amin, Amr El Etreby
Effect Of Artificial Aging On Hardness And Surface Roughness Of Two Types Of Zirconia, Ramy Hamed Elsherif, Mona Hossam El-Din Mandour, Rania A. Amin, Amr El Etreby
Future Dental Journal
No abstract provided.
Stress Analysis Comparing Effect Of Two Different Cad-Cam Implant Superstructure Materials (In-Vitro Study), Noura Turky Saad, Essam Osman, Ahmed M. Abdelhamid, Mohamed Shokry, Ehab A. Farghaly
Stress Analysis Comparing Effect Of Two Different Cad-Cam Implant Superstructure Materials (In-Vitro Study), Noura Turky Saad, Essam Osman, Ahmed M. Abdelhamid, Mohamed Shokry, Ehab A. Farghaly
BAU Journal - Creative Sustainable Development
Purpose: This study was conducted to evaluate the micro-strain around dental implant using two different CAD/CAM crown fabricated materials through strain gauge analysis. Materials and Methods: Five dental implants were fixed in a 5 previously drilled solid rigid polyurethane test blocks in the edentulous area with neighboring abutments mesial and distal printed out using special 3D Dental printer, Cyanoacrylate adhesive was then used to fix the printed-out part on to the polyurethane test blocks, creating the bounded saddle replicas. Ten CAD/CAM screw retained crowns were fabricated; five Enamic crowns from vita enamic blocks, and five zirconia crowns from presintered katana …