Open Access. Powered by Scholars. Published by Universities.®

Prosthodontics and Prosthodontology Commons™

Open Access. Powered by Scholars. Published by Universities.®

Chulalongkorn University Theses and Dissertations (Chula ETD)

Articles 1 - 30 of 74

Full-Text Articles in Prosthodontics and Prosthodontology

Stress And Burnout Level Among Bhutanese Dentists And Medical Officers In Bhutan, Karma Zangmo Jan 2025

Stress And Burnout Level Among Bhutanese Dentists And Medical Officers In Bhutan, Karma Zangmo

Chulalongkorn University Theses and Dissertations (Chula ETD)

Healthcare professionals, particularly dentists and physicians, are at high risk of stress and burnout due to long working hours, heavy workloads, clinical decision-making responsibilities, and the need for continuous knowledge updates. This study aimed to assess stress and burnout levels among Bhutanese dentists and physicians. A cross-sectional survey was conducted using online questionnaires distributed to 85 dentists and 325 physicians, with response rates of 87.7% and 52.6%, respectively. Stress was measured using the 14-item Perceived Stress Scale (PSS), and burnout was assessed with the 22-item Maslach Burnout Inventory (MBI). Among dentists, 97.8% reported stress, with 91.8% at moderate levels. Among …


Influence Of Shade On Color Reproducibility Of Lithium Disilicate Crowns, Naphat Santiworanart Jan 2025

Influence Of Shade On Color Reproducibility Of Lithium Disilicate Crowns, Naphat Santiworanart

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective: This study aimed to evaluate the influence of nominal shade on the color reproducibility of CAD-CAM lithium disilicate glass ceramic crowns.Materials and Methods: An in vitro study was conducted on 16 CAD-CAM lithium disilicate crowns (IPS e.max CAD LT) fabricated in four VITA Classical shades (A3, B3, C3, D3; N=4 per group). Each crown was cemented on a corresponding polymethylmethacrylate (PMMA) abutment of matching shade. Shade determination was performed using a spectrophotometer and an intraoral scanner under controlled conditions. Color trueness was assessed against the VITA Classical shade guide using exact match and broad acceptance criteria. The L*, a*, …


Effect Of Printing Orientation And Surface Treatment On The Surface Roughness, Shear Bond Strength, And Flexural Strength Of 3d-Printed Provisional Materials, Kornrawee Wiroonsri Jan 2025

Effect Of Printing Orientation And Surface Treatment On The Surface Roughness, Shear Bond Strength, And Flexural Strength Of 3d-Printed Provisional Materials, Kornrawee Wiroonsri

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study aimed to evaluate the influence of printing orientation and surface treatment on the surface roughness, shear bond strength (SBS), and flexural strength of three-dimensional (3D)-printed provisional resin materials. Four printing orientations (0°, 45°, 60°, and 90°) and four surface treatments (no treatment, airborne particle abrasion (APA), tetrahydrofuran (THF), and HC primer) were investigated. A total of 320 specimens were fabricated, post-processed, and tested according to ISO standards. Among these, 240 disk-shaped specimens were utilized for surface roughness assessment, conducted using a non-contact profilometer, and for SBS evaluation through a notched-edge shear test. Additionally, 80 rectangular bar specimens were …


Physico-Mechanical And Antibacterial Properties Of Resin-Based Dental Sealants Modified With Graphene Oxide Nanoparticles, Ploypim Kraisintu Jan 2025

Physico-Mechanical And Antibacterial Properties Of Resin-Based Dental Sealants Modified With Graphene Oxide Nanoparticles, Ploypim Kraisintu

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objectives: This study evaluated the effects of incorporating graphene oxide (GO) nanoparticles at different concentrations (0.1, 0.25, and 0.5 wt%) into resin-based pit and fissure sealants. Mechanical, physical, antibacterial, and cytotoxicity were tested and compared with a commercial reference material.Materials and Methods: An experimental resin-based sealant was formulated and reinforced with GO (G2–G4), while an unmodified resin served as control (G1) and Helioseal® F Plus as commercial comparison (G5). GO morphology was characterized by TEM. Specimens (n=240) were tested for Vickers microhardness, viscosity, surface roughness (DRa) after simulated toothbrushing, and fluorescence (% blue channel). Antibacterial activity against Streptococcus mutans was …


Occlusal Analysis Using A Novel Classification Of Static And Dynamic Articulations In Tmd And Non-Tmd Patients, Uthai Uma Jan 2025

Occlusal Analysis Using A Novel Classification Of Static And Dynamic Articulations In Tmd And Non-Tmd Patients, Uthai Uma

Chulalongkorn University Theses and Dissertations (Chula ETD)

Background: Temporomandibular disorders (TMD) are multifactorial conditions affecting masticatory systems. While occlusal morphology has been suggested as a contributing factor, functional, behavioral, and postural elements may play a more prominent role. This study aimed to evaluate demographic, clinical, occlusal, and functional characteristics associated with TMD in a Thai patient population using a novel articulation classification. Methods: A retrospective analysis of 872 participants (684 TMD, 188 non-TMD) was conducted. Data included demographic characteristics, postural and habitual behaviors, occlusal morphology, articulation classification, articulation ratios, mandibular range of motion, and TMD diagnostic categories. The articulation classification and ratios were designed and tested for …


Effect Of Different Surface Characterizations On Color Stability And Surface Roughness Of Provisional Materials After Toothbrushing, Sarasinee Sattawatthamrong Jan 2024

Effect Of Different Surface Characterizations On Color Stability And Surface Roughness Of Provisional Materials After Toothbrushing, Sarasinee Sattawatthamrong

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study aimed to evaluate the surface roughness of 5 provisional materials with different surface characterization methods after simulating 1 year of toothbrushing. Specimens were fabricated from autopolymerized polymethyl methacrylate (UNIFAST Trad), autopolymerized bis-acryl composite resin (Protemp 4), light-activated composite resin (REVOTEK LC), milled polymethyl methacrylate block (DD provi P HI), and 3-dimensionally printed methacrylate oligomer (Nextdent C&B MFH). Each material was divided into 3 groups: polishing, application of Lite Art and Resin Glaze, and application of OPTIGLAZE color. After 5,000 and 10,000 toothbrushing cycles, surface roughness was measured. A 3-way repeated measures ANOVA was conducted to analyze the effects …


The Effect Of Cement Thickness On Shear Bond Strength Of Zirconia With Three Different Self-Adhesive Resin Cements, Thofun Ieamsuwantada Jan 2024

The Effect Of Cement Thickness On Shear Bond Strength Of Zirconia With Three Different Self-Adhesive Resin Cements, Thofun Ieamsuwantada

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective: This study aimed to evaluate the influence of resin cement thickness on the shear bond strength (SBS) to zirconia using different self-adhesive resin cements (SAC). Materials and Methods: One hundred twenty irconia specimens were prepared, air abraded with 50 μm aluminium oxide particles and divided into 12 groups (n  = 10), according to the cement thickness (50, 100, 150, and 200 μm) and SAC (RelyXTM U200, PANAVIATM SA LUTING Multi, MaxcemTM Elite Chroma). The specimens were cemented to resin composite blocks with SAC, stored in water at 37°C for 24 hours and subjected to the SBS test. Mode of …


Effect Of Chairside Silicone Polishing Systems On The Surface Roughness Of Cad/Cam Milled And Conventional Denture Base Materials, Sarita Apiromwijit Jan 2024

Effect Of Chairside Silicone Polishing Systems On The Surface Roughness Of Cad/Cam Milled And Conventional Denture Base Materials, Sarita Apiromwijit

Chulalongkorn University Theses and Dissertations (Chula ETD)

Purpose: The objective of this study was to evaluate the effect of two commercial chairside polishing systems compared with conventional laboratory polishing on the surface roughness of two types of denture base materials. Methods: Square-shaped specimens (8x8x5 mm) were fabricated from CAD/CAM milled and heat-polymerized denture base materials. Each specimen was ground with tungsten carbide and then divided into three groups according to polishing techniques(n=8): Exa technique, AcryPoint, and conventional laboratory polishing. The roughness (Ra) values were measured using a non-contact profilometer after finishing with tungsten carbide bur, every 30 seconds with each subsequent polisher (rough, medium, and fine) of …


The Study On Surface Roughness And Corrosion Resistance Of Electropolished Laser Powder Bed Fusion Ti-6al-4v Eli Alloy, Venus Chatpaiboonwat Jan 2024

The Study On Surface Roughness And Corrosion Resistance Of Electropolished Laser Powder Bed Fusion Ti-6al-4v Eli Alloy, Venus Chatpaiboonwat

Chulalongkorn University Theses and Dissertations (Chula ETD)

The Ti6Al4V ELI alloy produced via Laser Powder Bed Fusion (L-PBF) has drawn interest for usage in dental applications. However, surface finishing is an important property that can be managed by various methods. The purpose of this study was to investigate the effects of electropolishing (EP) on the surface roughness and corrosion resistance of L-PBF Ti6Al4V ELI alloy. The present study explored the influence of current density, voltage, and distance on the surface quality and corrosion behavior. The results showed that EP significantly reduced the surface roughness and enhanced corrosion resistance of printed Ti6Al4V ELI alloy with the best result …


การศึกษาการสึกระหว่างโคบอลต์โครเมียมและวัสดุเซรามิกที่ใช้ในงานทันตกรรมดิจิตอล, มรกต ไทยรัตน์ Jan 2024

การศึกษาการสึกระหว่างโคบอลต์โครเมียมและวัสดุเซรามิกที่ใช้ในงานทันตกรรมดิจิตอล, มรกต ไทยรัตน์

Chulalongkorn University Theses and Dissertations (Chula ETD)

วัตถุประสงค์: ทำการศึกษาสภาวะจำลองเพื่อวัดการสูญเสียปริมาตรจากการสึกหลังจากจำลองการขัดถู 250,000 รอบของโลหะผสมโคบอลต์โครเมียม (CoCr) กับวัสดุที่ใช้ทำการบูรณะฟันหลักห้าชนิด วัสดุและวิธีการ: เตรียมตัวอย่างทดสอบตัดเป็นสี่เหลี่ยมจำนวนชนิดละ 8 ชิ้น (5 x 5 x 2 มิลลิเมตร) จากโลหะผสมที่ไม่มีทองผสม (NP), ลิเธียมไดซิลิเกต (EM) เธียมไดซิลิเกตเสริมความแข็งแรง (TR) เซรามิคที่มีเรซินเป็นฐาน (CM) และเซอร์โคเนีย (ZR) ตัวอย่าง EM TR และ ZR ได้รับการเผาตามคำแนะนำของผู้ผลิต แท่งโลหะผสมโคบอลต์โครเมียมสร้างขึ้นโดยการหล่อโลหะแบบไล่ขี้ผึ้ง จำลองการสึกแบบสององค์ประกอบด้วยเครื่องจำลองการสึกจากการขัดถู จำนวน 250,000 รอบ วัดการสูญเสียปริมาตรของชิ้นงานทดสอบโดยใช้เครื่องวัดความหยาบพื้นผิว การสูญเสียปริมาตรของแท่งโลหะผสมคำนวณโดยการความยาวที่ลดลงและรัศมีของพื้นที่ที่เกิดบริเวณที่สึก วิเคราะห์ข้อมูลทางสถิติโดยใช้ MANOVA (pNP>ZR) การสูญเสียปริมาตรของแท่งโลหะหลังการสึกในกลุ่ม CM น้อยกว่าในกลุ่ม EM และ NP ในขณะที่กลุ่มอื่น ๆ ไม่มีความแตกต่างกันอย่างมีนัยสำคัญ


Effect Of Chromium Metal Alloy Fabrication Techniques On Enamel Wear, Pattrapond Eopsirisuk Jan 2023

Effect Of Chromium Metal Alloy Fabrication Techniques On Enamel Wear, Pattrapond Eopsirisuk

Chulalongkorn University Theses and Dissertations (Chula ETD)

This in vitro study aimed to investigate the effect of different chromium metal alloys on enamel wear through longitudinal observation across various simulated chewing cycles. Four groups of alloys were studied (n=10 per group): casting Ni-Cr alloys (NC), casting Co-Cr alloys (CC), SLM Co-Cr alloys (CS), and heat-treated SLM Co-Cr alloys (CS-H). The test simulated chewing of enamel cusps against the alloys in distilled water under specific conditions (49 N load, 0.7 mm sliding movement, and 1.6 Hz frequency). Enamel wear was measured at 60,000, 120,000, and 240,000 cycles by using intraoral scanner matching with open-source 3D software. Enamel wear …


ผลของการปรับสภาพพื้นผิวต่อกำลังแรงยึดเฉือนระหว่างวัสดุครอบฟันชั่วคราวกับแบร็กเกตจัดฟันโลหะ, มนนภัส เลาหะอัญญา Jan 2023

ผลของการปรับสภาพพื้นผิวต่อกำลังแรงยึดเฉือนระหว่างวัสดุครอบฟันชั่วคราวกับแบร็กเกตจัดฟันโลหะ, มนนภัส เลาหะอัญญา

Chulalongkorn University Theses and Dissertations (Chula ETD)

งานวิจัยมีวัตถุประสงค์เพื่อเปรียบเทียบกําลังแรงยึดเฉือนระหว่างแบร็กเกตจัดฟันโลหะกับครอบฟันชั่วคราวชนิดต่าง ๆ ที่ใช้การปรับสภาพพื้นผิวที่แตกต่างกัน เตรียมวัสดุบูรณะครอบฟันชั่วคราว 3 ชนิด ได้แก่ พอลิเมทิลเมทาคริเลตชนิดบ่มด้วยตัวเอง (Unifast™ Trad) พอลิเมทิลเมทาคริเลตชนิดแคดแคม (CADCAM VIPI Block) และเรซินคอมโพสิตชนิดบิสเอคริล (Protemp™ 4) จำนวน 4 กลุ่ม กลุ่มละ 11 ชิ้น นำวัสดุปรับสภาพพื้นผิวด้วยการทามอนอเมอร์เมทิลเมทาคริเลต การเป่าผงอะลูมินัมออกไซด์ การใช้เข็มกรอกากเพชร และกลุ่มที่ไม่ได้ถูกปรับสภาพพื้นผิวเป็นกลุ่มควบคุม นำชิ้นงานตรวจความหยาบของพื้นผิวและส่องด้วยกล้องจุลทรรศน์อิเล็กตรอนแบบส่องกราด ทำการยึดติดแบร็กเกตจัดฟันโลหะด้วยเรซินแอดฮีซีฟทรานสบอนด์ เอ็กซ์ที นำไปทดสอบค่ากำลังแรงยึดเฉือนด้วยเครื่องทดสอบอเนกประสงค์โดยใช้ความเร็วในการทดสอบที่ 1 มิลลิเมตรต่อนาที ศึกษาดัชนีส่วนเหลือของสารยึดติดด้วยกล้องจุลทรรศน์ชนิดสเตอริโอ วิเคราะห์ด้วยสถิติการวิเคราะห์ความแปรปรวนแบบสองทางที่ระดับนัยสําคัญ 0.05 และเปรียบเทียบแต่ละกลุ่มโดยใช้สถิติ Games-Howell test ผลการศึกษาพบว่าวัสดุบิสเอคริลการเป่าผงอะลูมินัมออกไซด์มีค่ากำลังแรงยึดเฉือนสูงที่สุด ตามมาด้วยการใช้เข็มกรอกากเพชร และการทามอนอเมอร์ ตามลำดับ วัสดุพอลิเมทิลเมทาคริเลตชนิดแคดแคมการเป่าผงอะลูมินัมออกไซด์มีค่ากำลังแรงยึดเฉือนสูงที่สุด ตามด้วยการทามอนอเมอร์ และการใช้เข็มกรอกากเพชร ตามลำดับ และวัสดุพอลิเมทิลเมทาคริเลตชนิดบ่มด้วยตัวเองการทามอนอเมอร์และการเป่าผงอะลูมินัมออกไซด์ มีค่ากำลังแรงยึดเฉือนสูงที่สุดโดยไม่แตกต่างกันอย่างมีนัยสำคัญทางสถิติ ตามด้วยการใช้เข็มกรอกากเพชร ดังนั้นการปรับสภาพพื้นผิวด้วยการเป่าผงอะลูมินัมออกไซด์มีประสิทธิภาพในการเพิ่มแรงยึดติดแบร็กเกตจัดฟันมากที่สุด ในพอลิเมทิลเมทาคริเลตชนิดบ่มด้วยตัวเองควรทามอนอเมอร์เมทิลเมทาคริเลตเพิ่มเติม และวัสดุบิสเอคริลมีแรงยึดติดกับแบร็กเกตจัดฟันมากที่สุดหลังปรับสภาพพื้นผิวเชิงกล


Effect Of Aprotic Solvents On The Microtensile Bond Strength Of Composite Core And Fiber-Reinforced Composite Posts, Wisarut Prawatvatchara Jan 2023

Effect Of Aprotic Solvents On The Microtensile Bond Strength Of Composite Core And Fiber-Reinforced Composite Posts, Wisarut Prawatvatchara

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective: The purpose of this study was to examine the effect of aprotic solvents, which were tetrahydrofuran, pyridine, and morpholine, compared to hydrogen peroxide on surface roughness of fiber-reinforced composite post and microtensile bond strength between fiber-reinforced composite post surfaces and the composite core. Material and methods: A total of 75 FRC posts plus, and 75 D.T. light posts were divided into 3 groups (non-thermocycling, 5,000-cycle and 10,000cycle thermocycling groups). Each group was divided into five subgroups according to the post-surface treatment: C: non-treatment group; H2O2: immersing with 35% hydrogen peroxide; THF: immersing with tetrahydrofuran; PY: immersing with pyridine; MP: …


The Effect Of Different Functional Monomer Of Zirconia Primer And Universal Adhesive On Shear Bond Strength Of Zirconia To Composite Resin Using Resin Cement, Pimchanok Pitakassawakul Jan 2023

The Effect Of Different Functional Monomer Of Zirconia Primer And Universal Adhesive On Shear Bond Strength Of Zirconia To Composite Resin Using Resin Cement, Pimchanok Pitakassawakul

Chulalongkorn University Theses and Dissertations (Chula ETD)

Zirconia has been increasing used due to its good mechanical properties but the study about the ability to bond to zirconia ceramic is still limited. The purpose of this study is to evaluate the bond strength of zirconia using MDP-containing zirconia primer and GPDM-containing universal adhesive. Twenty-one super-high translucent zirconia discs (Ceramil zolid fx White; AMANN GIRRBACH, Austria), 8.5 mm in diameter and 3.2 mm in thickness, were prepared. The specimens were divided into 3 groups (n=7) according to primer application, Group I: no primer application (control group), Group II: Z-Prime plus® (Bisco, Schaumburg, Illinois, USA) and Group III: Optibond …


Analysis Of Gene Expression And Histology Of Bone Regeneration Using Mrna Encoding Bone Morphogenetic Protein-2 In Rat Femur, Duangporn Yongyosrungrueng Jan 2023

Analysis Of Gene Expression And Histology Of Bone Regeneration Using Mrna Encoding Bone Morphogenetic Protein-2 In Rat Femur, Duangporn Yongyosrungrueng

Chulalongkorn University Theses and Dissertations (Chula ETD)

The quality of bone healing is an important factor in dental implant treatment. Currently, there is only limited research on using mRNA encoding BMP-2 to improve the quality and quantity of bone. This study aimed to evaluate the effectiveness of bone healing in rat femur defect after delivery of dPBS, rhBMP-2 and mRNA-encoding BMP-2 (BMP-2 mRNA-LNP). Histology approach was used to measure the quantity of newly formed bone. RT-qPCR was used to study gene expression levels of BMP-2, OCN, BSP and TNF-α. Subsequently, RNA-Seq analysis was performed at six weeks post-operation. Histological study revealed that BMP-2 mRNA-LNP group had significantly …


The Effect Of Different Self-Adhesive Resin Cements On Shear Bond Strength Of Hybrid Ceramic And Dentin, Rattawich Hoonsuwan Jan 2023

The Effect Of Different Self-Adhesive Resin Cements On Shear Bond Strength Of Hybrid Ceramic And Dentin, Rattawich Hoonsuwan

Chulalongkorn University Theses and Dissertations (Chula ETD)

ActivaTM bioactive is the first developed of dual cured, self-adhesive resin cement. For this in vitro study was to compare and evaluate the three differentsshear bond strength among ActivaTM bioactive, Maxcem EliteTM and RelyXTMU200 cement, when used as adhesive between CAD-CAM hybrid ceramic; Vita EnamicTM and dentin surface. The Vita EnamicTM block was designed and fabricated into forty-two discs shaped with CAD software. Forty-two extracted third maxillary molars was also collected. The all teeth were free of dental caries, restoration and cracked line were mounted vertically in the epoxy resin with exposedthe occlusal surface. Dentin surfaces were flatted surface by …


Micro-Computed Tomography And Mechanical Test Of Bone Regeneration Using Mrna Encoding Bone Morphogenetic Protein-2 With Implant Placement In Rat Femur, Kanoksiri Jriyasetapong Jan 2023

Micro-Computed Tomography And Mechanical Test Of Bone Regeneration Using Mrna Encoding Bone Morphogenetic Protein-2 With Implant Placement In Rat Femur, Kanoksiri Jriyasetapong

Chulalongkorn University Theses and Dissertations (Chula ETD)

This research evaluates the effectiveness of a modified mRNA encoding bone morphogenetic protein-2 (m1Ψ-BMP-2 mRNA) with N1-methylpseudouridine modifications on bone regeneration and integration after implantation into rat femur defects. In the study, twelve femurs from six Sprague-Dawley rats underwent titanium wire insertation. These femur defects were then filled with either 5 μg of m1Ψ-BMP-2 mRNA, 15 μg of m1Ψ-BMP-2 mRNA, or Dulbecco's phosphate-buffered saline (dPBS) in a randomized manner (N=4 each group) Six weeks post-implantation, the rats were euthanized for evaluation using micro-computed tomography and a mechanical push-out test. The Micro-CT analysis focused on several parameters including total bone volume, …


Effect Of Different Implant Angulations And Insertion-Removal Cycles On The Retentive Force Of Locator And Locator R-Tx Attachments, Jidapha Tangtrongmit Jan 2023

Effect Of Different Implant Angulations And Insertion-Removal Cycles On The Retentive Force Of Locator And Locator R-Tx Attachments, Jidapha Tangtrongmit

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study aims to assess the implant of varying angulations and insertion-removal cycles on the retentive force of 2 denture attachments. The blocks were produced via 3D printing and divided into 2 groups: the LOCATOR attachment with orange retentive inserts and the LOCATOR R-Tx attachment with pink retentive inserts. Each group was divided into 3 subgroups based on implant angulation at 0-, 15-, and 30-degree implant angulation. The insertion-removal cycles were performed in 37 ±1°C deionized water using an INSTRON E1000 machine. Retentive force tests were conducted using a universal testing machine at baseline, after 270, 540, 810, 1080, 2160, …


Gene Expression Of Soft Tissue Covering Bone Grafted With Xenograft In Human, Atithan Termworasin Jan 2023

Gene Expression Of Soft Tissue Covering Bone Grafted With Xenograft In Human, Atithan Termworasin

Chulalongkorn University Theses and Dissertations (Chula ETD)

Soft tissue is one of many factors that influence the esthetic success of dental implants. This study explores soft tissue reaction between soft tissue covering bone grafted with xenograft and soft tissue in normal healing by analyzing the levels of inflammatory cytokine including TNF-α, IL-6, IL-8 and NF-kB1. Soft tissues are collected after 4 to 6 months of healing and analyzed by reverse transcription quantitative polymerase chain reaction (RT-qPCR). The result shows that the relative gene expression of TNF-α, IL-6, IL-8, and NF-kB1 are not significantly different in soft tissue covering xenograft compared to the ones in soft tissue covering …


The Effect Of Surface Treatment And Types Of Translucent Monolithic Zirconia On The Shear Bond Strength Of Porcelain Repaired To Zirconia, Karnkanith Hansomwong Jan 2023

The Effect Of Surface Treatment And Types Of Translucent Monolithic Zirconia On The Shear Bond Strength Of Porcelain Repaired To Zirconia, Karnkanith Hansomwong

Chulalongkorn University Theses and Dissertations (Chula ETD)

In the event of proximal contact loss in a zirconia crown on an implant, the zirconia crown can be modified by adding porcelain to recreate the proximal contact. This study investigated the shear bond strength between translucent zirconia (4Y-PSZ) and veneering porcelain compared to conventional zirconia (3Y-TZP). Zirconia substructures were treated with airborne-particle abrasion with Al2O3. The results of the shear bond strength test were analyzed by One-way ANOVA and post-hoc comparisons with Tukey’s honest significant difference (HSD) test. The shear bond strengthranged from 21.87 and 27.79 MPa. The failure mode was mixed failure in all groups. From the results, …


Geriatric Esthetics: A Comparison Of Prosthodontists, General Practitioners, And Laypeople's Perception, Rawinun Puangkaew Jan 2023

Geriatric Esthetics: A Comparison Of Prosthodontists, General Practitioners, And Laypeople's Perception, Rawinun Puangkaew

Chulalongkorn University Theses and Dissertations (Chula ETD)

In this study, we evaluated the esthetic perceptions of prosthodontists, general practitioners, and laypeople in elderly smile, using varying the exposure of the maxillary incisors in rest position and a full smile, size of buccal corridor and gingival display of maxillary posterior teeth. The picture of elderly smile was modified and shown with randomized sequence. Participants are asked to rate each image by using a numerical visual analog scale (0-10 scale). A total of 150 participants consisted of 50 Thai prosthodontists, 50 general practitioners, and 50 laypeople. Some pictures exhibited statistically significant differences (p0.05). All variation of incisal display were …


การปิดสีโดยใช้ชนิดเรซินคอมโพสิตและความหนาที่แตกต่างกัน, กชรัตน์ นันทเสน Jan 2023

การปิดสีโดยใช้ชนิดเรซินคอมโพสิตและความหนาที่แตกต่างกัน, กชรัตน์ นันทเสน

Chulalongkorn University Theses and Dissertations (Chula ETD)

ความสวยงามในเรื่องสีของฟันเป็นสิ่งหนึ่งที่ผู้ป่วยให้ความสำคัญเมื่อมารับการรักษาทางทันตกรรม โดยการเปลี่ยนสีฟันด้วยสิ่งบูรณะฟันโดยตรง ซึ่งเป็นการบูรณะฟันโดยตรงในช่องปากโดยใช้เรซินคอมโพสิต เป็นทางเลือกในการรักษาที่มีความนิยมมากขึ้น เนื่องจากมีการทำอันตรายต่อฟันน้อยที่สุด แต่ความสามารถในการปิดสีของเรซินคอมโพสิตอาจมีความแตกต่างกันไปตามแต่ละชนิด ถ้าสามารถเลือกชนิดของเรซินคอมโพสิตที่ปิดสีได้ดีในความหนาที่น้อย ก็จะช่วยลดการสูญเสียโครงสร้างฟันได้ งานวิจัยนี้จึงมีวัตถุประสงค์เพื่อเปรียบเทียบสีภายหลังการบูรณะด้วยชนิดของเรซินคอมโพสิตที่แตกต่างกัน โดยการนำเรซินคอมโพสิต 3 ชนิด ได้แก่ เคลียร์ฟิลเอพีเอ็กซ์, เมต้าฟิลซีเอ็กซ์ และฟิลเท็คซีทูไฟว์ซีโร่ ที่มีความหนา 4 ระดับ ได้แก่ 0.5, 1, 1.5 และ 2 มิลลิเมตร มาเปรียบเทียบความสามารถในการปิดสี โดยวัดด้วยตามนุษย์และเครื่องสเปกโทรโฟโตมิเตอร์ และประเมินความแตกต่างโดยใช้การทดสอบแบบครัสคัล-วอลลิสและการวิเคราะห์ความแปรปรวนทางเดียว ผลการศึกษาพบความแตกต่างอย่างมีนัยสำคัญทางสถิติที่ระดับความเชื่อมั่นร้อยละ 95 ระหว่างกลุ่มเรซินคอมโพสิตและความหนาที่ต่างกัน กล่าวโดยสรุป เรซินคอมโพสิตชนิดเมต้าฟิลซีเอ็กซ์มีความสามารถในการปิดสีเข้มสุด A6 ได้ดีกว่าเรซินคอมโพสิตชนิดเคลียร์ฟิลเอพีเอ็กซ์และฟิลเท็คซีทูไฟว์ซีโร่ในทุกระดับความหนา โดยเรซินคอมโพสิตชนิดเมต้าฟิลซีเอ็กซ์ที่ความหนาประมาณ 1.5 – 2 มิลลิเมตร สามารถบูรณะฟันสี A6 ให้ได้สีฟันที่ระดับ A1


Evaluation Of Tensile Bond Strength Of Various Denture Relining Materials To Conventional And Cad/Cam Manufactured Denture Base Polymers, Pilipda Janyaprasert Jan 2023

Evaluation Of Tensile Bond Strength Of Various Denture Relining Materials To Conventional And Cad/Cam Manufactured Denture Base Polymers, Pilipda Janyaprasert

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study was to investigate the tensile bond strength (TBS) of autopolymerized, heat-polymerized, milled, and 3D printed denture base materials bonded to 2 acrylic-based and 2 silicone-based denture liners, both before and after thermocycling. Four different denture base materials (Palapress (PL), Vertex Rapid Simplified (VR), Smile CAM total prosthesis (SC), and NextDent denture 3D+ (ND)) bonded to 2 acrylic-based (GC Soft-Liner (GC) and Tokuyama Rebase II (RB)) and 2 silicone-based (Ufi Gel P (UP) and Sofreliner Tough M (ST)) denture liners were tested. Specimens (n=8) were divided into non-thermocycling and thermocycling groups. Data were analyzed using 2-way ANOVA and Tukey …


Oral And Dental Prostheses Status In Mild And Moderate Dementia Patients, Tunyatorn Ratanawatanasin Jan 2023

Oral And Dental Prostheses Status In Mild And Moderate Dementia Patients, Tunyatorn Ratanawatanasin

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study focused on understanding the oral health and dental prostheses status of patients with mild to moderate dementia at King Chulalongkorn Memorial Hospital. A total of 88 patients participated in this cross-sectional study, which utilized the Oral Health Assessment Tool (OHAT) and modified CDA score to evaluate the oral health of patients with a dementia diagnosis. The study revealed significant oral health issues among participants, particularly in terms of gum and oral tissue problems, and oral cleanliness. Although 45.5% of participants had at least 20 functional teeth, a high prevalence of dental decay was observed. Many of the fixed …


การเปลี่ยนแปลงคุณภาพชีวิตในมิติสุขภาพช่องปากและในมิติสุขภาพในผู้ป่วยที่ได้รับการรักษาทางทันตกรรมประดิษฐ์, ปิยอนงค์ วรรณขาว Jan 2023

การเปลี่ยนแปลงคุณภาพชีวิตในมิติสุขภาพช่องปากและในมิติสุขภาพในผู้ป่วยที่ได้รับการรักษาทางทันตกรรมประดิษฐ์, ปิยอนงค์ วรรณขาว

Chulalongkorn University Theses and Dissertations (Chula ETD)

การศึกษานี้เป็นการศึกษาไปข้างหน้าจากเหตุไปหาผลในผู้ป่วยเข้ารับการรักษารับการรักษาทางทันตกรรรมประดิษฐ์จำนวน 87 คน ผลลัพธ์ของการศึกษาคือคุณภาพชีวิตในมิติสุขภาพช่องปากและคุณภาพชีวิตในมิติสุขภาพ โดยใช้ดัชนีประเมินผลกระทบของสุขภาพช่องปากต่อสมรรถภาพในชีวิตประจำวันและเครื่องมือวัดคุณภาพชีวิตขององค์การอนามัยโลกฉบับย่อ ตามลำดับ ตัวแปรร่วม ได้แก่ ลักษณะทั่วไป สภาวะสุขภาพและสภาวะสุขภาพช่องปาก เก็บข้อมูลโดยการสัมภาษณ์ การตรวจในช่องปากและการศึกษาจากแฟ้มประวัติ หลังการแก้ไขฟันเทียมครั้งสุดท้าย 1 เดือน เก็บข้อมูลคุณภาพชีวิตในมิติสุขภาพช่องปากและคุณภาพชีวิตในมิติสุขภาพโดยการสัมภาษณ์ทางโทรศัพท์ ใช้การทดสอบของการทดสอบวิลคอกซันวิเคราะห์การเปลี่ยนแปลงของคะเเนน OIDP และ WHOQOL-BREF เวลาก่อนและหลังการรักษา ข้อมูลทั้งหมดวิเคราะห์ที่ระดับนัยสำคัญร้อยละ 5 ผลการศึกษาแสดงว่าหลังการรักษาผู้เข้าร่วมการศึกษามีคะแนน OIDP รวมลดลงอย่างมีนัยสำคัญทางสถิติ และคะแนน WHOQOL-BREF รวมเพิ่มขึ้นอย่างมีนัยสำคัญทางสถิติ โดยที่เวลาก่อนการรักษาปัจจัยที่ส่งผลต่อคะแนน OIDP รวมคือจำนวนฟันธรรมชาติและจำนวนคู่สบฟันหลัง ในขณะที่ปัจจัยที่ส่งผลต่อคะแนน WHOQOL-BREF รวมคือสถานภาพสมรสและความเพียงพอของรายได้ จึงสรุปได้ว่าภายหลังการรักษาทางทันตกรรมประดิษฐ์ผู้ป่วยมีคุณภาพชีวิตในมิติสุขภาพช่องปากและคุณภาพชีวิตในมิติสุขภาพดีขึ้น


Effect Of Implant Coronal Wall Thickness With Similar Abutment Connection On Retaining Screw After Eccentric Loading, Tanittha Sintunon Jan 2022

Effect Of Implant Coronal Wall Thickness With Similar Abutment Connection On Retaining Screw After Eccentric Loading, Tanittha Sintunon

Chulalongkorn University Theses and Dissertations (Chula ETD)

The objectives of this study were to investigate the effect of different implant coronal wall thicknesses with similar abutment connection on the percentage of removal torque loss and tensile removal force after eccentric cyclic loading, and to compare the percentage of removal torque loss before and after eccentric cyclic loading in each implant group. Twenty-four implants with internal conical connection system were divided into three groups (n=8) with diameters of 3.75-, 4.3-, and 6.0-mm (0.375-, 0.65-, and 1.5-mm coronal wall thickness groups) x 10-mm length, and their prosthetic abutments. The implants were subjected to cyclic loading (1x106 cycles, 15 Hz) …


พฤติกรรมสุขอนามัยฟันเทียมของผู้ป่วยฟันเทียมทั้งปากถอดได้และประสิทธิผลของวิธีการให้สุขอนามัยฟันเทียมต่อความสะอาดของฟันเทียมทั้งปากถอดได้, ปวิชญา พึ่งชื่น Jan 2022

พฤติกรรมสุขอนามัยฟันเทียมของผู้ป่วยฟันเทียมทั้งปากถอดได้และประสิทธิผลของวิธีการให้สุขอนามัยฟันเทียมต่อความสะอาดของฟันเทียมทั้งปากถอดได้, ปวิชญา พึ่งชื่น

Chulalongkorn University Theses and Dissertations (Chula ETD)

จากการศึกษาที่ผ่านมาพบว่า ผู้ที่ใส่ฟันเทียมถอดได้มีพฤติกรรมสุขอนามัยฟันเทียมที่ไม่เหมาะสมและมีค่าความสะอาดฟันเทียมไม่ดีซึ่งส่งผลต่อสุขอนามัยช่องปากและการใช้งานของฟันเทียม การศึกษานี้จึงมีวัตถุประสงค์เพื่อศึกษาพฤติกรรมสุขอนามัยฟันเทียมของผู้ป่วยและผลของการให้สุขอนามัยฟันเทียมด้วยวิธีที่แตกต่างกันต่อค่าความสะอาดของฟันเทียมทั้งปากถอดได้ โดยทำการสัมภาษณ์ข้อมูลทั่วไปและพฤติกรรมสุขอนามัยฟันเทียมผู้ป่วยทั้งหมด 53 คนที่เข้ามารับการรักษาโดยการทำฟันเทียมทั้งปากถอดได้ที่คณะทันตแพทยศาสตร์จุฬาลงกรณ์มหาวิทยาลัย หลังจากนั้นผู้ป่วยจะถูกสุ่มแบ่งเป็น 2 กลุ่มตามวิธีการได้รับสุขอนามัยฟันเทียมดังนี้ กลุ่มที่ได้รับสุขอนามัยฟันเทียมโดยวิธีบอกปากเปล่าและกลุ่มที่ได้รับสุขอนามัยฟันเทียมโดยวิธีสาธิต ตรวจค่าความสะอาดฟันเทียม (ทั้งหมดจำนวน 64 ชิ้น) 2 ครั้งในขั้นตอนการติดตามและแก้ไขและขั้นตอนการตรวจตามระยะ 6 เดือน โดยย้อมสีฟันเทียมด้านเนื่อเยื่อด้วย 6% อีรีโทรซินเพื่อให้เห็นคราบจุลลินทรีย์ชัดเจนและประเมินความสะอาดฟันเทียมโดยใช้เกณฑ์ของ Schubert and Schubert ใช้สถิติทดสอบทีอิสระในการเปรียบเทียบวิธีการให้สุขอนามัยฟันเทียมที่แตกต่างกันกับค่าความสะอาดฟันเทียมที่เปลี่ยนแปลงไป ผลการศึกษาพบว่า ผู้ป่วยส่วนใหญ่แปรงฟันเทียมด้วยแปรงสีฟันและยาสีฟัน มีเพียงบางส่วนใช้เม็ดฟู่ทำความสะอาดฟันเทียม ส่วนใหญ่ไม่ได้ใส่ฟันเทียมนอนและไม่ตระหนักถึงความสำคัญของการมาตรวจสภาพฟันเทียมเป็นประจำ วิธีการให้สุขอนามัยโดยวิธีสาธิตมีค่าความสะอาดฟันเทียมที่เปลี่ยนแปลงไปน้อยกว่ากลุ่มบอกปากเปล่าแต่ไม่พบนัยสำคัญทางสถิติและพบว่าบางตำแหน่งของฟันเทียมมีการติดสีมากกว่าที่อื่น จากผลการศึกษา ผู้ป่วยยังมีความเข้าใจผิดในเรื่องสุขอนามัยฟันเทียมและมักไม่ได้ตระหนักถึงความสำคัญ ดังนั้นทันตแพทย์ควรจะให้ความสำคัญในการให้สุขอนามัยฟันเทียมและเลือกวิธีให้สุขอนามัยฟันเทียมให้เหมาะสมกับผู้ป่วยเพื่อให้ผู้ป่วยเข้าใจและสามารถดูแลฟันเทียมของตัวเองได้ตลอดการใช้งาน


ความสัมพันธ์ระหว่างการประเมินคุณภาพฟันเทียมบางส่วนถอดได้โดยทันตแพทย์ และการประเมินผลการรักษาด้วยตนเองของผู้ป่วย, มนุญญา อัจฉริยพันธุ์ Jan 2022

ความสัมพันธ์ระหว่างการประเมินคุณภาพฟันเทียมบางส่วนถอดได้โดยทันตแพทย์ และการประเมินผลการรักษาด้วยตนเองของผู้ป่วย, มนุญญา อัจฉริยพันธุ์

Chulalongkorn University Theses and Dissertations (Chula ETD)

ความสำเร็จของงานฟันเทียมบางส่วนถอดได้ประเมินได้จากการตรวจทางคลินิกโดยทันตแพทย์และการประเมินผลการรักษาโดยผู้ป่วย การศึกษานี้มีวัตถุประสงค์เพื่อศึกษาปัจจัยของการตรวจประเมินคุณภาพฟันเทียมบางส่วนถอดได้ ที่มีความสัมพันธ์กับผลการรักษาที่ประเมินโดยผู้ป่วย โดยศึกษาในผู้ป่วยฟันเทียมบางส่วนถอดได้จำนวน 140 คน ด้วยการสัมภาษณ์ข้อมูลสังคมประชากร ทำแบบประเมินผลกระทบของสุขภาพช่องปากต่อชีวิตประจำวัน (OIDP) และแบบสอบถามการบริโภคอาหาร ตรวจสภาวะช่องปาก ประเมินคุณภาพฟันเทียมและทดสอบสมรรถนะการบดเคี้ยวของผู้ป่วย วิเคราะห์ความแตกต่างของคะแนน OIDP คะแนนแบบสอบถามการบริโภคอาหารและคะแนนสมรรถนะการบดเคี้ยวของแต่ละปัจจัยด้วยสถิติทดสอบแมน-วิทนีย์ยูหรือครัสคาล-วัลลิส พบความสัมพันธ์ระหว่างปัจจัยและคะแนนแบบประเมิน OIDP ที่ต่ำกว่าได้แก่จำนวนฟันเหลือมากกว่า 20 ซี่ จำนวนคู่สบมากกว่า 4 คู่ โครงโลหะที่คุณภาพดี ซี่ฟันเทียมไม่สึก ฟันเทียมมีเสถียรภาพและการยึดอยู่ดี พบความสัมพันธ์ระหว่างปัจจัยและคะแนนแบบแบบสอบถามการบริโภคอาหารที่สูงกว่าได้แก่ฟันเทียมชนิดรองรับด้วยฟัน จำนวนฟันเหลือมากกว่า 20 ซี่ จำนวนคู่สบมากกว่า 4 คู่ สภาวะปริทันต์ของฟันหลักปกติ ซี่ฟันเทียมไม่สึก ฟันเทียมมีเสถียรภาพและการยึดอยู่ดี พบความสัมพันธ์ระหว่างปัจจัยและคะแนนสมรรถนะการบดเคี้ยวที่สูงกว่าได้แก่เพศชาย อายุน้อยกว่า 60 ปี มีการประกอบอาชีพ ไม่มีโรคประจำตัว มีประสบการณ์ใส่ฟันเทียม มีฟันเทียมชนิดรองรับด้วยฟัน จำนวนฟันเหลือมากกว่า 20 ซี่ จำนวนคู่สบมากกว่า 4 คู่และสภาวะปริทันต์ของฟันหลักปกติ มีโครงโลหะที่ดี ซี่ฟันเทียมไม่สึก ฟันเทียมมีเสถียรภาพและการยึดอยู่ดี จะเห็นได้ว่ามีปัจจัยทั้งในส่วนของตัวผู้ป่วย สภาวะช่องปากและคุณภาพฟันเทียมที่มีความสัมพันธ์กับการรายงานผลของผู้ป่วย ดังนั้นการตรวจสภาวะช่องปากและคุณภาพฟันเทียมไม่ควรตรวจเพียงทางคลินิกเพียงอย่างเดียว ควรประเมินการรายงานผลของผู้ป่วยร่วมด้วย


Comparison Of Compressive Strength Between Two Mini Implants :An In Vitro Study, Anchisa Weerasubpong Jan 2022

Comparison Of Compressive Strength Between Two Mini Implants :An In Vitro Study, Anchisa Weerasubpong

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective: To observe and evaluate the difference in static and dynamic loadings between two mini-implant systems (RetenDent and MS denture® system, OSSTEM). Materials and Methods: Fifty mini-implant from two companies were included in the study. The compressive force was applied to the mini-implants at 30 degrees from its vertical axis. Ten specimens from each group were subjected to static load tests. Subsequently, five cyclic loadings were calculated from static compressive strength. These loads include 320N, 275N, 230N, 185N, and 140N. Three specimens from each group were randomly selected and tested at each loading condition. The Independent T- test was utilized …


Influence Of Cad/Cam Materials On Damping Behavior Of Implant-Supported Crown, Charnikan Sukkasam Jan 2022

Influence Of Cad/Cam Materials On Damping Behavior Of Implant-Supported Crown, Charnikan Sukkasam

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study was to investigate the damping capacity of implant-supported crowns made from various computer-aided design and computer-aided manufacturing (CAD-CAM) restorative materials. A titanium implant fixture was embedded in epoxy resin. Crown specimens were divided into three groups: Zirconia (Z), Lithium disilicate (E), and Polymethyl methacrylate (P). Each crown was subdivided into Uncement (Un) and Adhesive resin cement (RC) subgroups (n=5). Specimens were loaded (0-200N). Strain gauges were attached to measure microstrains at crestal and apical levels. Damping capacity was determined based on load-time curves, microstrain-time curves, and time required to reach the maximum load. A two-way ANOVA with Tukey …