Open Access. Powered by Scholars. Published by Universities.®
Other Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (122)
- Biomedical Devices and Instrumentation (101)
- Life Sciences (81)
- Mechanical Engineering (60)
- Biological Engineering (59)
-
- Biomaterials (55)
- Biomechanics and Biotransport (54)
- Chemical Engineering (52)
- Molecular, Cellular, and Tissue Engineering (49)
- Electrical and Computer Engineering (48)
- Physical Sciences and Mathematics (44)
- Bioimaging and Biomedical Optics (43)
- Biochemical and Biomolecular Engineering (39)
- Biomechanical Engineering (37)
- Medical Sciences (36)
- Biomedical (34)
- Bioelectrical and Neuroengineering (30)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (29)
- Materials Science and Engineering (26)
- Diseases (23)
- Medical Specialties (22)
- Systems and Integrative Engineering (22)
- Biochemistry, Biophysics, and Structural Biology (19)
- Cell and Developmental Biology (19)
- Nanoscience and Nanotechnology (19)
- Chemicals and Drugs (17)
- Biotechnology (16)
- Institution
-
- California Polytechnic State University, San Luis Obispo (110)
- University of Arkansas, Fayetteville (49)
- University of Nebraska - Lincoln (32)
- Virginia Commonwealth University (25)
- Chapman University (24)
-
- Clemson University (16)
- University of Louisville (16)
- University of New Mexico (16)
- University of Kentucky (14)
- City University of New York (CUNY) (13)
- Louisiana Tech University (12)
- Purdue University (11)
- University of Connecticut (10)
- Washington University in St. Louis (9)
- West Virginia University (9)
- Technological University Dublin (8)
- Brigham Young University (7)
- Michigan Technological University (7)
- University of Mississippi (7)
- Air Force Institute of Technology (5)
- Louisiana State University (5)
- Old Dominion University (5)
- Syracuse University (5)
- The University of Akron (5)
- University of Nebraska at Omaha (5)
- University of South Alabama (5)
- The British University in Egypt (4)
- The Texas Medical Center Library (4)
- University of Denver (4)
- University of Texas at Arlington (4)
- Keyword
-
- Microfluidics (11)
- Arteriogenesis (9)
- Machine learning (9)
- Applied sciences (8)
- Ischemia (8)
-
- Biomedical engineering (7)
- Biomedical Engineering (6)
- Mouse (6)
- Angiogenesis (5)
- Biomechanics (5)
- Bioreactor (5)
- Machine Learning (5)
- Nanotechnology (5)
- Ultrasound (5)
- Aptamer (4)
- Bioinformatics (4)
- Biomedical (4)
- Bone (4)
- Daniel Felix Ritchie School of Engineering and Computer Science (4)
- Deep Learning (4)
- Device (4)
- Diabetes (4)
- Diagnostics (4)
- EMG (4)
- Electrocardiogram (4)
- Endothelial Dysfunction (4)
- Mechanotransduction (4)
- Nanoparticles (4)
- Osteoporosis (4)
- Vasodilation (4)
- Publication Year
- Publication
-
- Master's Theses (66)
- Biomedical Engineering Undergraduate Honors Theses (46)
- Biomedical Engineering (38)
- Theses and Dissertations (30)
- Electronic Theses and Dissertations (21)
-
- Engineering Faculty Articles and Research (17)
- Dissertations and Theses (12)
- Doctoral Dissertations (12)
- Theses and Dissertations--Biomedical Engineering (12)
- All Dissertations (9)
- Biomedical Engineering ETDs (9)
- Honors Theses (9)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (9)
- All Theses (7)
- Biomedical Engineering Western Regional Conference (7)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (7)
- Dissertations, Master's Theses and Master's Reports (7)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (7)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (7)
- Department of Mechanical and Materials Engineering: Faculty Publications (5)
- Honors Scholar Theses (5)
- Mechanical Engineering (5)
- Renée Crown University Honors Thesis Projects - All (5)
- UNO Student Research and Creative Activity Fair (5)
- Williams Honors College, Honors Research Projects (5)
- Articles (4)
- Chemical and Materials Engineering Faculty Publications (4)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (4)
- Dissertations and Theses (Open Access) (4)
- LSU Doctoral Dissertations (4)
- Publication Type
- File Type
Articles 241 - 270 of 519
Full-Text Articles in Other Biomedical Engineering and Bioengineering
The Effect Of Radial Head Hemiarthroplasty Stem Fit On Radiocapitellar Contact Mechanics: Is Loose Fit Better Than Rigidly Fixed?, Jakub Szmit, Graham J.W. King, James A. Johnson, G. Daniel G. Langohr
The Effect Of Radial Head Hemiarthroplasty Stem Fit On Radiocapitellar Contact Mechanics: Is Loose Fit Better Than Rigidly Fixed?, Jakub Szmit, Graham J.W. King, James A. Johnson, G. Daniel G. Langohr
Western Research Forum
Background/Methods: Radial head hemiarthroplasty is commonly employed to manage comminuted displaced fractures. With regards to implant fixation, current designs vary with some prostheses aiming to achieve a tight 'fixed' fit, and others utilizing a smooth stem with an over reamed 'loose' fit. The purpose of the present study was to evaluate the effect of radial head hemiarthroplasty stem fit on radiocapitellar contact using a finite element model which simulated both fixed (size-for-size) and loose (1, 2 & 3mm over reamed) stem fits.
Hypothesis: It was hypothesized that a loose stem fit would improve radiocapitellar contact mechanics, with increased contact area …
Fibrinogen, Factor Xiii And Fibronectin: A Biophysical And Kinetic Characterization Of Their Interactions, Frank Fabian
Fibrinogen, Factor Xiii And Fibronectin: A Biophysical And Kinetic Characterization Of Their Interactions, Frank Fabian
Department of Chemical and Biomolecular Engineering: Dissertations, Theses, and Student Research
The development of recombinant-based liquid fibrin tissue sealants having enhanced hemostatic and wound healing properties will involve understanding as yet not well characterized interactions between fibrinogen, fibrin (Fbn) factor XIII, thrombin and fibronectin. We study these phenomena in the context of comparing plasma derived fibrinogen to recombinant fibrinogen (rFI) produced in the milk of transgenic cows. An abundance of purified γγ and γγ’ FI subspecies enables detailed study of γγ or γγ’ biomonomer and their respective Fbn biopolymer formation as having different substrate behaviors of activated plasma derived factor XIII (pFXIIIa2b2). High pressure size exclusion (HPSEC) …
Cooking Hand Multi-Tool, Amanda D. Meares, Amy H. Wilson, Ethan G. Littlejohn, Duania A. Evans
Cooking Hand Multi-Tool, Amanda D. Meares, Amy H. Wilson, Ethan G. Littlejohn, Duania A. Evans
Biomedical Engineering
The purpose of this project was to devise a solution for Jorge Segura, a US Marine who was wounded in Afghanistan and had to have his non-dominant arm amputated above the elbow. His current prosthetic attachments are not suited to cooking tasks, so he needed a way to cook more effectively with either prosthetic attachments or accessibility devices. The main tasks that he needed help with was holding down food on cutting boards and stabilizing pots, pans, and bowls especially when stirring. After background research, exploring commercially available devices, and talking with our challenger, our solution was to design three …
A 3-Dimensional In Silico Test Bed For Radiofrequency Ablation Catheter Design Evaluation And Optimization, Carolyn Teng
A 3-Dimensional In Silico Test Bed For Radiofrequency Ablation Catheter Design Evaluation And Optimization, Carolyn Teng
Master's Theses
Atrial fibrillation (AF) is the disordered activation of the atrial myocardium, which is a major cause of stroke. Currently, the most effective, minimally traumatic treatment for AF is percutaneous catheter ablation to isolate arrhythmogenic areas from the rest of the atrium. The standard in vitro evaluation of ablation catheters through lesion studies is a resource intensive effort due to tissue variability and visual measurement methods, necessitating large sample sizes and multiple prototype builds. A computational test bed for ablation catheter evaluation was built in SolidWorks® using the morphology and dimensions of the left atrium adjacent structures. From this geometry, the …
Age Dependent Regulation Of Cardiac Sodium Channel Gain Of Function, Madison Nowak, David Ryan King, Steven Poelzing, Seth Weinberg
Age Dependent Regulation Of Cardiac Sodium Channel Gain Of Function, Madison Nowak, David Ryan King, Steven Poelzing, Seth Weinberg
Biology and Medicine Through Mathematics Conference
No abstract provided.
Identification And Analysis Of Behavioral Phenotypes In Autism Spectrum Disorder Via Unsupervised Machine Learning, Elizabeth Stevens, Dennis R. Dixon, Marlena N. Novack, Doreen Granpeesheh, Tristram Smith, Erik Linstead
Identification And Analysis Of Behavioral Phenotypes In Autism Spectrum Disorder Via Unsupervised Machine Learning, Elizabeth Stevens, Dennis R. Dixon, Marlena N. Novack, Doreen Granpeesheh, Tristram Smith, Erik Linstead
Engineering Faculty Articles and Research
Background and objective: Autism spectrum disorder (ASD) is a heterogeneous disorder. Research has explored potential ASD subgroups with preliminary evidence supporting the existence of behaviorally and genetically distinct subgroups; however, research has yet to leverage machine learning to identify phenotypes on a scale large enough to robustly examine treatment response across such subgroups. The purpose of the present study was to apply Gaussian Mixture Models and Hierarchical Clustering to identify behavioral phenotypes of ASD and examine treatment response across the learned phenotypes.
Materials and methods: The present study included a sample of children with ASD (N = 2400), …
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi S. Patel
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi S. Patel
University Scholar Projects
Background: Reconstruction of bone fractures and defects remains a big challenge in orthopedic surgery. While regenerative engineering has advanced the field greatly using a combination of biomaterial scaffolds and stem cells, one matter of difficulty is inducing osteogenesis in these cells. Recent works have shown electricity’s ability to promote osteogenesis in stem cell lines when seeded in bone scaffolds; however, typical electrical stimulators are either (a) externally housed and require overcomplex percutaneous wires be connected to the implanted scaffold or (b) implanted non-degradable devices which contain toxic batteries and require invasive removal surgeries.
Objective: Here, we establish a biodegradable, piezoelectric …
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi Patel
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi Patel
Honors Scholar Theses
Background: Reconstruction of bone fractures and defects remains a big challenge in orthopedic surgery. While regenerative engineering has advanced the field greatly using a combination of biomaterial scaffolds and stem cells, one matter of difficulty is inducing osteogenesis in these cells. Recent works have shown electricity’s ability to promote osteogenesis in stem cell lines when seeded in bone scaffolds; however, typical electrical stimulators are either (a) externally housed and require overcomplex percutaneous wires be connected to the implanted scaffold or (b) implanted non-degradable devices which contain toxic batteries and require invasive removal surgeries.
Objective: Here, we establish a biodegradable, piezoelectric …
Vector Flow Imaging In Pediatric Cardiology - Extracting And Validating Data, Mason Belue
Vector Flow Imaging In Pediatric Cardiology - Extracting And Validating Data, Mason Belue
Biomedical Engineering Undergraduate Honors Theses
In the field of bedside cardiac diagnostic imaging, Doppler Ultrasound (DU) is the gold standard for diagnosing heart conditions. The largest benefit of DU is its ability to noninvasively image cardiac flow and allow the estimation of blood velocity and quantification of anatomical disease. However, to get correct velocity estimation, the position of the transducer in relation to the flow field needs to be known. This is the problem of angle/direction dependency and limits DUs accuracy when imaging in areas where perfect alignment or exact position of the transducer in relation to flow field is not possible or known, such …
Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre
Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre
Honors Scholar Theses
Abnormal ocular motility is a common manifestation of many underlying pathologies particularly those that are neurological. Dynamics of saccades, when the eye rapidly changes its point of fixation, have been characterized for many neurological disorders including concussions, traumatic brain injuries (TBI), and Parkinson’s disease. However, widespread saccade analysis for diagnostic and research purposes requires the recognition of certain eye movement parameters. Key information such as velocity and duration must be determined from data based on a wide set of patients’ characteristics that may range in eye shapes and iris, hair and skin pigmentation [36]. Previous work on saccade analysis has …
Comparing The Effects Of Fibroblast Growth Factors On Growth Rate Of Human Fibroblast Cell Lines, Tasha Repella
Comparing The Effects Of Fibroblast Growth Factors On Growth Rate Of Human Fibroblast Cell Lines, Tasha Repella
Biomedical Engineering Undergraduate Honors Theses
Numerous studies have demonstrated the usefulness of growth factors in medium formulations to promote proliferation and viability of human fibroblasts in laboratory settings. However, due to the differences in the source and age of fibroblasts, the ability of growth factors like hFGF1 to promote proliferation varies. Equally difficult is the ability of hFGF1 to promote proliferation of diseased fibroblasts due to complexities associated with specific mitochondrial diseases. In this context, we decided to evaluate the potential for novel hyper stable growth factors super hFGF and hFGF1 (shFGF and hFGF1 respectively), to contribute to proliferation of different normal and diseased fibroblasts. …
Methods To Remotely Eliminate Biofilm From Medical Implants Using 2.4 Ghz Microwaves, Brett Glenn
Methods To Remotely Eliminate Biofilm From Medical Implants Using 2.4 Ghz Microwaves, Brett Glenn
Mechanical Engineering Undergraduate Honors Theses
Infections associated with biofilm growth are usually challenging to eradicate due to their high tolerance toward antibiotics [11, 12]. Biofilms often form on the inert surfaces of medically implanted devices [13]. No matter the sophistication, microbial infections can develop on all medical devices and tissue engineering constructs [12]. Related infections lead to 2 million cases annually in the U.S., costing the healthcare system over $5 billion in additional healthcare expenses [12].
Novel solutions to biofilm’s microbial colonization span the spectrum of engineering and science disciplines. Yet a practical solution still does not exist. The research presented here will explore a …
The Role Of Gene Expression Noise In Mammalian Cell Survival, Kevin Farquhar
The Role Of Gene Expression Noise In Mammalian Cell Survival, Kevin Farquhar
Dissertations and Theses (Open Access)
Drug resistance and metastasis remain obstacles to effective cancer treatment. A major challenge contributing to this problem is cellular heterogeneity. Even in the same environment, cells with identical genomes can display cell-to-cell differences in gene expression, also known as gene expression noise. Gene expression noise can vary in magnitude in a population or in fluctuation time scales, which is influenced by gene regulatory networks.
Currently, it is unclear how gene expression noise from gene regulatory networks contributes to drug survival outcomes in mammalian cells. An isogenic cell line with a noise-modulating genetic system tuned to the same mean is required. …
Deswelling Induced Morphological Changes In Dual Ph And Temperature Responsive Ultra-Low Crosslinked Poly (N-Isopropyl Acrylamide)-Co-Acrylic Acid Microgels, Molla R. Islam, Maddie Tumbarello, L. Andrew Lyon
Deswelling Induced Morphological Changes In Dual Ph And Temperature Responsive Ultra-Low Crosslinked Poly (N-Isopropyl Acrylamide)-Co-Acrylic Acid Microgels, Molla R. Islam, Maddie Tumbarello, L. Andrew Lyon
Engineering Faculty Articles and Research
Poly(N-isopropylacrylamide) microgels prepared without exogenous cross-linker are extremely “soft” as a result of their very low cross-linking density, with network connectivity arising only from the self-crosslinking of pNIPAm chains. As a result of this extreme softness, our group and others have taken interest in using these materials in a variety of bioengineering applications, while also pursuing studies of their fundamental properties. Here, we report deswelling triggered structural changes in poly(N-isopropylacrylamide-co-acrylic acid) (ULC10AAc) microgels prepared by precipitation polymerization. Dynamic light scattering suggests that the deswelling of these particles not only depends on the collapse of …
Analysis Of The Effect Of Corrosion On The Surface Chemistry Of Mild Steel Exposed To Biofuel, Timothy D. Plourde
Analysis Of The Effect Of Corrosion On The Surface Chemistry Of Mild Steel Exposed To Biofuel, Timothy D. Plourde
Theses and Dissertations
The use of biofuels in society is steadily becoming more prevalent. Through this proliferation a concern regarding the role of the fungus Byssochlamys nivea in microbially induced corrosion has surfaced. Through the use of X-ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscope (SEM) technology, this thesis focused on attempting to determine what effect, if any, Byssochlamys nivea has on the corrosion of mild steel. For this analysis, samples were placed in environments that simulated the conditions of fuel tanks containing the biofuel B20, water, and spores of Byssochlamys nivea for varying lengths of time. However, due to a variety of …
Mobility-Based Models For Advancing Diagnostic/Predictive Healthcare, Elham Rastegari
Mobility-Based Models For Advancing Diagnostic/Predictive Healthcare, Elham Rastegari
UNO Student Research and Creative Activity Fair
Functional ability has been always considered as one of the important determining factors of individuals’ health and quality of life. Traditional movement analysis systems require expensive facilities and frequent visits for patients to specialized laboratories. Portability and affordability of wearable sensors along with their improved accuracy and capability of monitoring movement during daily activities make them a potential alternative for analyzing mobility patterns for clinical and health assessment purposes. Wearable-based movement data, when combined with other relevant clinical or laboratory data, could enhance evidence-based healthcare and data-driven Clinical Decision Support Systems (CDSS). Utilizing the data from wearable devices, many researchers …
Concussion Indication Device, Taylor O'Donoghue, Isabel Jellen, Eric Shechter
Concussion Indication Device, Taylor O'Donoghue, Isabel Jellen, Eric Shechter
Biomedical Engineering
In this document we summarize our intent to design and manufacture a device that will be used in conjunction with a football helmet, will detect impact forces to the head, and notify the user to seek out further medical attention when subjected to forces large enough to cause concussions. We describe the large market including all levels of football players and the need for improved technology that will not only be effective in elucidating risks but encouraging players to use the device over the alternatives. To design the device, we have researched the problem of concussions in football and have …
Accelerated Wear Reactor Testing, Tristan Frisella, Daniel Alanis, Kian Ashoubi
Accelerated Wear Reactor Testing, Tristan Frisella, Daniel Alanis, Kian Ashoubi
Biomedical Engineering
Carbon dioxide accounts for a large amount of global greenhouse gases released into the environment. Because plastic degradation emits carbon dioxide, there has been interest to investigate how much carbon dioxide various plastics generate as they degrade. We have been tasked to create a dehumidifier and carbon dioxide sensor assembly for an accelerated wear testing apparatus that degrades plastic. Several products and literature currently exist that share similarity with our assembly but have not been manufactured to achieve the same combination of measurements we are expecting of our accelerated wear testing device. The following report shall introduce these products and …
Foot Support Taping Device For Off-Loading Wounds, Andres Fojaco Gomez, Mikaela Williams, Josh Pelegrin
Foot Support Taping Device For Off-Loading Wounds, Andres Fojaco Gomez, Mikaela Williams, Josh Pelegrin
Biomedical Engineering
No abstract provided.
Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer
Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer
Biomedical Engineering
The slit lamp ophthalmoscope is used by ophthalmologists for diagnosis of pathologies in the eye. The device is used for identifying ocular diseases or indications of other possible systemic diseases to treat them before the diseases progress. Redesign of the ergonomics and adjustment mechanisms of the slit lamp ophthalmoscope will attempt to improve the compatibility of the device across a greater variety of patients. The wider headrest tower of 12.75 inches, the wider table cutout of 12 inches, and the 12 inches of extension of the headrest tower creates a better ergonomic fit for the patient and doctor. The wider …
Ideomotion Gait Training Thigh Prompt, Kristin Schmidt, Elizabeth Peterson, Dalton Jennings
Ideomotion Gait Training Thigh Prompt, Kristin Schmidt, Elizabeth Peterson, Dalton Jennings
Biomedical Engineering
This document serves as our project report at its completion for developing thigh prompts to be used with the LiftWalker. In this document we outline our project from its beginning to end. We describe our process from understanding the background and our customer requirements, transforming these customer requirements into engineering specifications, performing the stage gate process, developing and evolving the design, testing the design, and finally drawing conclusions and making recommendations for the future.
Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler
Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler
Master's Theses
Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …
Development Of An Astrocyte/Glioma Co-Culture System For Measuring Cellular Dynamics, Urna Kansakar
Development Of An Astrocyte/Glioma Co-Culture System For Measuring Cellular Dynamics, Urna Kansakar
Doctoral Dissertations
Gliomas are brain tumors that primarily arise from glial cells. Gliomas account for 70% of the brain tumors and they are more prevalent in older adults. About 60% of the people with gliomas experience at least one seizure. Brain tumors can grow and metastasize to neighboring areas, thereby destroying normal brain cells. In a brain tumor microenvironment, both malignant cancer cells and healthy brain cells are present. Studies have shown that astrocytes may have a role in tumor growth in the brain. Monocultures cannot evaluate interactions between two cell types and does not accurately represent in vivo conditions. Thus, a …
Development Of A Counter-Flow Thermal Gradient Microfluidic Device, Shayan Davani
Development Of A Counter-Flow Thermal Gradient Microfluidic Device, Shayan Davani
Doctoral Dissertations
This work presents a novel counter-flow design for thermal stabilization of microfluidic thermal reactors. In these reactors, precise control of temperature of the liquid sample is achieved by moving the liquid sample through the thermal zones established ideally through the conduction in the solid material of the device. The goal here is to establish a linear thermal distribution when there is no flow and to minimize the temperature change at flow condition. External convection as well as internal flowinduced effects influence the prescribed thermal distribution. The counter-flow thermal gradient device developed in this study is capable of both stabilizing the …
Aptamer Functionalized Zinc Oxide Field Effect Transistors For Odor Detection, Michael D. Aldridge
Aptamer Functionalized Zinc Oxide Field Effect Transistors For Odor Detection, Michael D. Aldridge
Graduate Theses, Dissertations, and Problem Reports (ETD)
Odor detection and identification are complex processes, and tasks that currently only animals do well. There is a pressing need for an electronic nose, or eNose, with good sensitivity, selectivity, and speed that mimics that ability. Food quality control operations, environmental sensing, occupational safety, and the defense sectors all require systems that can rapidly and reliably detect trace levels of volatile organic compounds. The goal of this work is to create a biologically inspired device which can accurately detect and identify odors at concentrations consistent with the most sensitive biological systems.
In order to mimic a natural olfactory system, we …
Special Issue On Low Temperature Plasma Jets, Mounir Laroussi
Special Issue On Low Temperature Plasma Jets, Mounir Laroussi
Electrical & Computer Engineering Faculty Publications
[Introduction] Low temperature plasma jets are unique plasma sources capable of delivering plasma outside of the confinement of electrodes and away from gas enclosures/chambers. With these jets plasma can be easily delivered to a target located at some distance from the plasma generation region [1].
Effects Of Micro-Features On Cell Detachment From Poly(N-Isopropylacrylamide) Coated Polydimethylsiloxane Membranes, Luke Webel
Williams Honors College, Honors Research Projects
The tested hypothesis was that features on polydimethylsiloxane (PDMS) surfaces coated with a poly(N-isopropylacrylamide)/aminopropyltriethoxysilane or pNIPAAM/APTES thin film would accelerate cell detachment than the film coated on a unfeatured surface. This project tested samples with features generated by molds, wrinkling, and sandpaper roughened substrates. Surface feature generation methods were limited to mechanical means, and characterized by microscopy and strain rates. 50/50 mixtures of 1.5 wt.% pNIPAAM/ APTES were used to coat thin films (30-40 nm) on PDMS membranes by spin-coating, and the coated membranes were thermally annealed to chemically graft pNIPAAm/APTES on the membrane and their thermo-responsive property was assessed …
Ergoscopetm – Ergonomic Endoscope, Drew Drum, John D'Egidio, Bethany Scarpitti, Ceara Stack, Sara Kerestman
Ergoscopetm – Ergonomic Endoscope, Drew Drum, John D'Egidio, Bethany Scarpitti, Ceara Stack, Sara Kerestman
Williams Honors College, Honors Research Projects
Medical endoscopy is a growing industry, with a trend of chronic hand pain for gastroenterologists and flexible endoscope users. In order to address the lack of ergonomics in traditional gastrointestinal (GI) flexible endoscopes, the design team collaborated with a GI professional to design a more ergonomic endoscope interface, focusing on the more problematic controls. Two prototypes, as well as a mock-up were fabricated, which underwent verification and a user evaluation to assess the design’s benefits. As the number of endoscopies each year increase, the Ergoscope, offers an alternative to the traditional angulation controls and muchneeded relief for the issues that …
Cell Type And Substrate Dependence Of Fibronectin Properties And Mechanotransduction, Navpreet S. Saini
Cell Type And Substrate Dependence Of Fibronectin Properties And Mechanotransduction, Navpreet S. Saini
Theses and Dissertations
Fibronectin is an important protein that is able to bind to other fibronectin molecules and to cell surface receptors. In doing so, the interactions fibronectin can perform is important for the processes of cell migration and tissue formation. Understanding the properties of fibronectin and fibril assembly is useful for areas such as wound healing, where fibronectin molecules are assembled to protect the tissue and to perform other tasks. Because of these reasons, it is important to understand how fibronectin is assembled and how its properties affect the fibril assembly, which in return affects the way the cell matrix operates. Previously …
Design And Testing Of An Agonist-Antagonist Position-Impedance Controlled Myoelectric Prosthesis, Christopher Aymonin
Design And Testing Of An Agonist-Antagonist Position-Impedance Controlled Myoelectric Prosthesis, Christopher Aymonin
Theses and Dissertations
Intuitive prosthetic control is limited by the inability to easily convey intention and perceive physical requirements of the task. Rather than providing haptic feedback and allowing users to consciously control every component of manipulation, relegating some aspects of control to the device may simplify operation. This study focuses on the development and testing of a control scheme able to identify object stiffness and regulate impedance. The system includes an algorithm to detect the apparent stiffness of an object, a proportional nonlinear EMG control algorithm for interpreting a user’s desired grasp aperture, and an antagonistically acting impedance controller. Performance of a …