Open Access. Powered by Scholars. Published by Universities.®
Other Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Angioplasty balloon (1)
- Biological image processing (1)
- Brain stress (1)
- Concussion (1)
- Coronary artery (1)
-
- Coronary heart disease (1)
- Finite element analysis (1)
- Finite element simulation (1)
- Fluoroscopy (1)
- Gene expression (1)
- Head impacts (1)
- Head injury (1)
- Live cell imaging (1)
- Materials testing (1)
- Mechanical testing (1)
- Mechanotransduction (1)
- Mixed martial arts (1)
- Mouthguard (1)
- Restenosis (1)
- Stent (1)
- Tissue Engineering (1)
- Unhelmeted sport (1)
Articles 1 - 4 of 4
Full-Text Articles in Other Biomedical Engineering and Bioengineering
Finite Element Simulation Of Head Impacts In Mixed Martial Arts, Stephen Tiernan, Aidan Meagher, David O'Sullivan Dr, Eoin O'Kelly Dr
Finite Element Simulation Of Head Impacts In Mixed Martial Arts, Stephen Tiernan, Aidan Meagher, David O'Sullivan Dr, Eoin O'Kelly Dr
Articles
This study determined brain stress and strain in an unhelmeted sport and correlated this with concussive injuries. Thirteen MMA athletes were fitted with the MiG2.0 Stanford instrumented mouthguard. The mouthguard records linear acceleration and angular velocity in 6 degrees of freedom. Angular acceleration was calculated by differentiation. All events were video recorded, time stamped and reported impacts confirmed. 298 impacts above 10g were recorded during sparring sessions and 153 impacts in competitive events. The competitive events resulted in five concussions which were diagnosed by a medical doctor. The impact with the highest angular acceleration from each sparring session and competitive …
Mattrack: A Matlab-Based Quantitative Image Analysis Platform For Investigating Real-Time Photo-Converted Fluorescent Signals In Live Cells, Jane Courtney, Elena Woods, Dimitri Scholz, William Hall, Virginie Gautier
Mattrack: A Matlab-Based Quantitative Image Analysis Platform For Investigating Real-Time Photo-Converted Fluorescent Signals In Live Cells, Jane Courtney, Elena Woods, Dimitri Scholz, William Hall, Virginie Gautier
Articles
We introduce here MATtrack, an open source MATLAB-based computational platform developed to process multi-Tiff files produced by a photo-conversion time lapse protocol for live cell fluorescent microscopy. MATtrack automatically performs a series of steps required for image processing, including extraction and import of numerical values from Multi-Tiff files, red/green image classification using gating parameters, noise filtering, background extraction, contrast stretching and temporal smoothing. MATtrack also integrates a series of algorithms for quantitative image analysis enabling the construction of mean and standard deviation images, clustering and classification of subcellular regions and injection point approximation. In addition, MATtrack features a simple user …
Finite Element Analysis Of Balloon-Expandable Coronary Stent Deployment: Influence Of Angioplasty Balloon Configuration, David Martin, Fergal Boyle
Finite Element Analysis Of Balloon-Expandable Coronary Stent Deployment: Influence Of Angioplasty Balloon Configuration, David Martin, Fergal Boyle
Articles
Today, the majority of coronary stents are balloon-expandable and are deployed using a balloon-tipped catheter. To improve deliverability, the membrane of the angioplasty balloon is typically folded about the catheter in a pleated configuration. As such, the deployment of the angioplasty balloon is governed by the material properties of the balloon membrane, its folded configuration and its attachment to the catheter. Despite this observation, however, an optimum strategy for modelling the configuration of the angioplasty balloon in finite element studies of coronary stent deployment has not been identified, and idealised models of the angioplasty balloon are commonly employed in the …
The Effect Of Physiological Cyclic Stretch On The Cell Morphology, Cell Orientation And Protein Expression Of Endothelial Cells, V. Barron, Claire Brougham, K. Coghlan, C. Stenson-Cox, D. O'Mahoney, P.E. Mchugh
The Effect Of Physiological Cyclic Stretch On The Cell Morphology, Cell Orientation And Protein Expression Of Endothelial Cells, V. Barron, Claire Brougham, K. Coghlan, C. Stenson-Cox, D. O'Mahoney, P.E. Mchugh
Articles
In vivo, endothelial cells are constantly exposed to pulsatile shear and tensile stresses. The main aim of this study was to design and build a physiological simulator, which reproduced homogenous strain profiles of the tensile strain experienced in vivo, and to investigate the effect of this cyclic tensile strain on the cell morphology, cell orientation and protein expression of endothelial cells. The biological response of human umbilical vein endothelial cells to a uniaxial cyclic stretch, in this newly developed simulator, was examined experimentally using immunohistostaining and confocal imaging and it was
found that the cells elongated and oriented at 58.9± …