Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi S. Patel May 2019

Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi S. Patel

University Scholar Projects

Background: Reconstruction of bone fractures and defects remains a big challenge in orthopedic surgery. While regenerative engineering has advanced the field greatly using a combination of biomaterial scaffolds and stem cells, one matter of difficulty is inducing osteogenesis in these cells. Recent works have shown electricity’s ability to promote osteogenesis in stem cell lines when seeded in bone scaffolds; however, typical electrical stimulators are either (a) externally housed and require overcomplex percutaneous wires be connected to the implanted scaffold or (b) implanted non-degradable devices which contain toxic batteries and require invasive removal surgeries.

Objective: Here, we establish a biodegradable, piezoelectric …


Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi Patel May 2019

Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi Patel

Honors Scholar Theses

Background: Reconstruction of bone fractures and defects remains a big challenge in orthopedic surgery. While regenerative engineering has advanced the field greatly using a combination of biomaterial scaffolds and stem cells, one matter of difficulty is inducing osteogenesis in these cells. Recent works have shown electricity’s ability to promote osteogenesis in stem cell lines when seeded in bone scaffolds; however, typical electrical stimulators are either (a) externally housed and require overcomplex percutaneous wires be connected to the implanted scaffold or (b) implanted non-degradable devices which contain toxic batteries and require invasive removal surgeries.

Objective: Here, we establish a biodegradable, piezoelectric …


Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre May 2019

Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre

Honors Scholar Theses

Abnormal ocular motility is a common manifestation of many underlying pathologies particularly those that are neurological. Dynamics of saccades, when the eye rapidly changes its point of fixation, have been characterized for many neurological disorders including concussions, traumatic brain injuries (TBI), and Parkinson’s disease. However, widespread saccade analysis for diagnostic and research purposes requires the recognition of certain eye movement parameters. Key information such as velocity and duration must be determined from data based on a wide set of patients’ characteristics that may range in eye shapes and iris, hair and skin pigmentation [36]. Previous work on saccade analysis has …


Distribution And Localization Of Novel Iodine Nanoparticles In The Human Glioma 1242 Growing In The Brains Of Mice, Benjamin Billings Jun 2018

Distribution And Localization Of Novel Iodine Nanoparticles In The Human Glioma 1242 Growing In The Brains Of Mice, Benjamin Billings

Honors Scholar Theses

Observing and designing the in vivo distribution and localization of therapeutic nanoparticles is an essential aspect of developing and understanding novel nanoparticle- based medical treatments. This study investigates novel PEGylated Iodine-based nanoparticles (INPs), an alternate composition to the more widely researched gold nanoparticles (AuNPs), which may help avoid adverse effects associated with AuNPs, such as potential toxicity and skin discoloration, when used in similar applications. Determining the localization of the novel INPs within murine brains containing human glioma U-1242MG cells is critical in assisting the development of radiation dose enhancement therapy for this aggressive cancer. Radiation dose enhancement utilizes the …


The Agile Approach In Pharmaceutical Software Development, Priyal Bhargava Apr 2017

The Agile Approach In Pharmaceutical Software Development, Priyal Bhargava

Honors Scholar Theses

The Agile development model is increasingly being adopted by the pharmaceutical industry for software development. Currently, there are several software projects under development by pharmaceutical companies that are using the Agile process. Other methodologies such as the Waterfall process, a traditional approach to project management, have evolved over time and been compared against the Agile method. Also there are conflicts of interest which should be taken into consideration when in a pharmaceutical setting such as abiding by FDA regulations. In addition, Agile’s sub-divisional approaches add to the versatility of how this iterative approach is applied in the pharmaceutical industry. The …


Design Of Exercise Equipment For Wheelchair Users: A Case Study In Accessibility Standards, Kate Craddock Rescsanszky May 2016

Design Of Exercise Equipment For Wheelchair Users: A Case Study In Accessibility Standards, Kate Craddock Rescsanszky

Honors Scholar Theses

Engineers must consider a number of aspects of every project they work on. Accessibility is one aspect that presents a unique challenge. Rather than being based on absolute material parameters, accessibility is based on how people interact with technology and their built environment. Since 1990, the Americans with Disabilities Act has been the predominant standard in accessibility because of its wide reach and legal mandate. In addition to the ADA, the ASTM and the Institute for Universal Design offer helpful guidelines for designing for accessibility. However, in addition to standards, guidelines, and recommendations, it is important to consult the intended …


A Depolymerization Based Model Of Neuron Growth Cone Shape And Motility, Neerajha Nagarajan Dec 2012

A Depolymerization Based Model Of Neuron Growth Cone Shape And Motility, Neerajha Nagarajan

Master's Theses

Cell migration is a ubiquitous process underlying critical biological mechanisms like wound healing, cancer metastasis and even neuron growth cone motility. It is a critical process for the living organisms as it ensures proper functioning of the system, for example, crawling fibroblasts endure closure of wounds during wound healing. Here we focus our interest on neuron growth cones, a sensory and motile organelle present at the tip of extending neurites, like the axons, in neurons. These are responsible for neuron pathfinding onto specific targets and synapses, in responses to various guidance cues. Interestingly, the motility of the growth cones is …


Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio May 2012

Development And Application Of A Portable System To Reliably Measure Grip Forces Using Thin-Film Force Sensors, Shane Vincent Tornifoglio

Master's Theses

Accurate tracking of hand grip force is an important consideration needed for a robust understanding in the study of human biomechanics. One aspect where it proves useful is in hand-arm vibration, such as from gripping a power tool. Depending on how firmly the user is gripping the tool, they may change their exposure levels to the tool vibration, which can lead to potential disorders such as Hand-Arm Vibration Syndrome (HAVS).

A small, battery powered portable force unit has been developed to supply power to, and condition, the signals from eight thin-film force sensors. This gives a better understanding of the …


Glucose Biosensor Using Electrospun Mn2o3-Ag Nanofibers, Shan Huang Aug 2011

Glucose Biosensor Using Electrospun Mn2o3-Ag Nanofibers, Shan Huang

Master's Theses

The highly porous Mn2O3-Ag nanofibers were fabricated by a facile two-step procedure (electrospinning and calcination) and then employed as the immobilization matrix for glucose oxidase (GOD) to construct an amperometric glucose biosensor. A notable enhancement of direct electron transfer between GOD and the electrode is observed at the Mn2O3-Ag-GOD modified electrode with a fast electron transfer rate constant. The biosensor also shows fast response to glucose, high sensitivity (40.60 μA×mM-1×cm-2), low detection limit (1.73 µM at S/N=3), low Km,app value and excellent selectivity. These results indicate that …


A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman May 2011

A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman

Master's Theses

Hemoglobin can be measured on a variety of devices using different principles of operation. Noninvasive pulse CO-oximetry represents the latest development in hemoglobin measuring technology. The technology uses principles similar to pulse oximetry to measure total hemoglobin, oxyhemoglobin, reduced oxyhemoglobin, carboxyhemoglobin and methemoglobin. Similar to the introduction of pulse oximetry to the medical field, pulse CO-oximetry has been met with skepticism. Since the technology is noninvasive and provides continuous monitoring in comparison to invasive and discrete techniques used in other methods, CO-oximetry purportedly provides an advantage in patient care. The purpose of this research is threefold: (a) to review the …