Open Access. Powered by Scholars. Published by Universities.®

Biomedical Devices and Instrumentation Commons™

Open Access. Powered by Scholars. Published by Universities.®

1,150 Full-Text Articles 2,223 Authors 594,801 Downloads 124 Institutions

All Articles in Biomedical Devices and Instrumentation

Faceted Search

1,150 full-text articles. Page 35 of 54.

Co-Modulation Masking Release Begins In The Auditory Periphery, Kareem R. Hussein, Agudemu Borjigan, Mark Sayles 2017 Purdue University

Co-Modulation Masking Release Begins In The Auditory Periphery, Kareem R. Hussein, Agudemu Borjigan, Mark Sayles

The Summer Undergraduate Research Fellowship (SURF) Symposium

Understanding speech in noisy environments can be difficult, especially for people with hearing loss. The background noise can cover up the sounds of interest. Normally, the auditory system works to alleviate this problem by tagging and then cancelling the noise. Our experiments are aimed at understanding the mechanism of this noise cancellation process. We hypothesize that non-linear signal processing in the mammalian cochlea (the most peripheral part of the auditory system) is the basis of noise cancellation. To test this hypothesis, we measured the responses of auditory-nerve fibers (ANFs) to sounds embedded in background noise with different statistical properties. ANFs …


Pathogenic Dna Detection Using Dna Hairpins: A Non-Linear Hybridization Chain Reaction Platform, Lance Novak, Tamara L. Kinzer-Ursem 2017 Purdue University

Pathogenic Dna Detection Using Dna Hairpins: A Non-Linear Hybridization Chain Reaction Platform, Lance Novak, Tamara L. Kinzer-Ursem

The Summer Undergraduate Research Fellowship (SURF) Symposium

Currently, 3.2 billion people are at risk of being infected with malaria, with 1.2 billion of those being at high risk (>1 in 1000 chance of getting malaria in a year). Thus, there is a need for a biosensor that is highly sensitive, cost effective, and simple to use for point-of-care diagnosis. The biosensing platform, PathVis, has achieved this by measuring changes in fluid properties after a loop-mediated isothermal amplification (LAMP). LAMP is a DNA amplification system that requires enzymes and a temperature of 65degrees C. LAMP currently limits PathVis by being costly, requiring refrigeration, and difficult to design. …


A Chronically Implanted, Continuous Ph Monitoring System For Rats, Ryan B. Budde, Pedro P. Irazoqui 2017 Purdue University

A Chronically Implanted, Continuous Ph Monitoring System For Rats, Ryan B. Budde, Pedro P. Irazoqui

The Summer Undergraduate Research Fellowship (SURF) Symposium

Many body systems operate within a strict pH range, and any deviation can cause harm. pH measurement systems are used in many biomedical research fields. Measurement systems have been able to continuously record pH for a short period of time wirelessly, or over a long period of time with wires, but no system is currently capable of long term, wireless, continuous pH recording. This paper proposes a new pH measurement system that is capable of such measurement. The system is composed of inexpensive, micro-scale, and easy to manufacture pH sensitive and reference electrodes and a data acquisition and transmission module …


Localized Blood Occlusion Generation In An In-Vitro Circulatory Catheter System, Ryan D. Harris, Qi Yang, Hyowon Lee 2017 Purdue University

Localized Blood Occlusion Generation In An In-Vitro Circulatory Catheter System, Ryan D. Harris, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a debilitating neurological disorder that involves the accumulation of cerebrospinal fluid in a ventricle of the brain. The implantation of a catheter commonly treats hydrocephalus with drainage. These catheters have a short lifespan due to obstruction from biological materials. Shunt systems have an extremely high failure rate of more than 40% failed within 1 year and up to 85% failed within 10 years. Previously, polymer-based flexible implantable magnetic micro-actuators were developed to clean up the catheter by mechanical vibration. We have demonstrated clearing of bacteria attachment and are proceeding to examine clearing effects on larger clotting materials, such …


The Influence Of The Electrode Dimension On The Detection Sensitivity Of Electric Cell–Substrate Impedance Sensing (Ecis) And Its Mathematical Modeling, Xudong Zhang, William Wang, Anis Nurashikin Nordin, Fang Li, Sunghoon Jang, ioana Voiculescu 2017 CUNY Graduate Center

The Influence Of The Electrode Dimension On The Detection Sensitivity Of Electric Cell–Substrate Impedance Sensing (Ecis) And Its Mathematical Modeling, Xudong Zhang, William Wang, Anis Nurashikin Nordin, Fang Li, Sunghoon Jang, Ioana Voiculescu

Publications and Research

Detection sensitivity is a crucial criterion in the design and application of ECIS sensors. The influence of sensing electrode dimension on detection sensitivity is investigated in this paper. Eight types of ECIS sensors were fabricated, and their experimental results reveal that smaller-radius working electrodes generate more sensitive impedance shift to cell density change. Also, the smaller radius of working electrodes yield higher impedance values, which improves signal-to-noise ratio. In a range from 1.0 mm to 3.5 mm, the distance between the working and counter electrodes does not affect impedance measurements. However, the distance should be large enough to prevent the …


Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris 2017 University of Nevada, Las Vegas

Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris

UNLV Theses, Dissertations, Professional Papers, and Capstones

It has been demonstrated that although many varieties of upper limb prosthetics exist, commercially available prosthetics are outdated and unsatisfactory. Ineffectiveness and limitations have led to some prosthesis wearers having to own multiple devices, whereas others have given up on them entirely. Even though ample research has been conducted to design and test new hand designs, the industry appears to rest in an overall stagnated state.

It was proposed here, that one problem with prosthetic research is an excess of variables involved in testing, and therefore the improper application of the scientific method. It seems that each time a research …


Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne 2017 University of Louisville

Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne

Electronic Theses and Dissertations

Based on the principles of cutting edge bone remodeling research, a unique therapeutic exercise device was designed specifically to improve bone quality at the most critical location of the proximal femur prone to fracture: the superior-lateral femoral neck where the fracture first initiates during a fall. The exercise/device is intended to work by inducing enough strain in the bone to stimulate the body’s natural bone remodeling mechanisms to increase bone density in the proximal femur and consequently prevent a fracture from arising if a fall to the side does occur.

In order to test the proposed exercise, experiments simulating the …


Markerless Kinematics Of Pediatric Manual Wheelchair Mobility, Jacob Robert Rammer 2017 Marquette University

Markerless Kinematics Of Pediatric Manual Wheelchair Mobility, Jacob Robert Rammer

Dissertations (1934 -)

Pediatric manual wheelchair users face substantial risk of orthopaedic injury to the upper extremities, particularly the shoulders, during transition to wheelchair use and during growth and development. Propulsion strategy can influence mobility efficiency, activity participation, and quality of life. The current forefront of wheelchair biomechanics research includes translating findings from adult to pediatric populations, improving the quality and efficiency of care under constrained clinical funding, and understanding injury mechanisms and risk factors. Typically, clinicians evaluate wheelchair mobility using marker-based motion capture and instrumentation systems that are precise and accurate but also time-consuming, inconvenient, and expensive for repeated assessments. There is …


Skin Tone Tracking Device (Chromaband), Ziyang Bian 2017 California Polytechnic State University, San Luis Obispo

Skin Tone Tracking Device (Chromaband), Ziyang Bian

Computer Engineering

It’s long been said that your skin is a window into your health and with many illnesses the first signs of trouble actually show up in your skin. So if we have this natural warning system, then why isn’t anyone able to effectively use it to predict changes in our health? The problem is that currently there is no reliable way to accurately measure the change in skin tone and how these changes may or may not change with variations in health. This project’s aim is to design and develop a device that will record the changes in a user’s …


Poly Drop, Zachary T. Scott, Lilly J. Paul 2017 California Polytechnic State University, San Luis Obispo

Poly Drop, Zachary T. Scott, Lilly J. Paul

Computer Engineering

Poly Drop is a software interface to control an Open Drop digital micro-fluidics system. We obtained a hardware system from Gaudi labs. Our task was to create a Graphical User Interface that made the control of the device easier and more automated for better testing. We created software that had 3 parts: a control GUI, arduino code to control the hardware, and Image Analysis that gives the user information such as location and color of liquid drops as they move across the electrode grid of the Open Drop system. The GUI was developed using Java Swing. The communication between the …


Redesign Of The Medtronic Kyphon Bone Cement Mixer For Vertebral Compression Fractures, Mollie Benson, Sarah Freesemann, AJ Konnath, Benjamin Murray 2017 California Polytechnic State University, San Luis Obispo

Redesign Of The Medtronic Kyphon Bone Cement Mixer For Vertebral Compression Fractures, Mollie Benson, Sarah Freesemann, Aj Konnath, Benjamin Murray

Biomedical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Optimizing Hybrid Plate Fixation With A Locked, Oblique End Screw In Osteoporotic Fractures, Patrick Atkinson, Aaron Wynkoop, Osy Ndubaku, Paul M. Charpentier, Jeffrey B. Peck, Norman E. Walter 2017 Kettering University

Optimizing Hybrid Plate Fixation With A Locked, Oblique End Screw In Osteoporotic Fractures, Patrick Atkinson, Aaron Wynkoop, Osy Ndubaku, Paul M. Charpentier, Jeffrey B. Peck, Norman E. Walter

Mechanical Engineering Publications

Background

The end screw in a fracture plate creates the greatest resistance to bending. For osteoporotic fractures treated with plates, there is some question as to the optimal screw insertion technique for the screw farthest from the fracture. A locked, oblique end screw was previously shown to increase resistance to periprosthetic fracture. It is unknown, however, how this end screw configuration would resist pullout when subjected to bending.

Methods

Narrow, low contact 3.5 mm locking compression plates with 6 and 12 holes were anchored to simulated bone material with material properties representing osteoporotic bone. Four configurations were evaluated for the …


Raman Spectral Variation For Human Fingernails Of Postmenopausal Women Is Dependent On Fracture Risk And Osteoporosis Status, J. R. Beattie, M. C. Caraher, N. M. Cummins, O. M. O'Driscoll, R. Eastell, S. H. Ralston, Mark R. Towler 2017 Missouri University of Science and Technology

Raman Spectral Variation For Human Fingernails Of Postmenopausal Women Is Dependent On Fracture Risk And Osteoporosis Status, J. R. Beattie, M. C. Caraher, N. M. Cummins, O. M. O'Driscoll, R. Eastell, S. H. Ralston, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Patients diagnosed with osteoporosis have reported loss of fingernail resilience as the disease progresses. Keratin is the predominant protein in human nail tissue, and its structure has been postulated to be different in fingernails clipped from subjects who have sustained fragility fractures and those who have not, which may offer a window into the donor's bone health. This study was designed to qualify these differences, which may lead to the development of a novel screening tool for fracture risk. Raman spectroscopy was used to measure the fingernails of 633 postmenopausal women who presented at six fracture clinics located across the …


A Deterministic Model Of The Effect Of Electric Field On Chemotherapeutics Delivery Into A Tumor, Maryam Moarefian, Luke Achenie 2017 Virginia Polytechnic Institute and State University

A Deterministic Model Of The Effect Of Electric Field On Chemotherapeutics Delivery Into A Tumor, Maryam Moarefian, Luke Achenie

Biology and Medicine Through Mathematics Conference

No abstract provided.


Detection Of Leukocytes Stained With Acridine Orange Using Unique Spectral Features Acquired From An Image-Based Spectrometer, Courtney J. Hunter 2017 University of Arkansas, Fayetteville

Detection Of Leukocytes Stained With Acridine Orange Using Unique Spectral Features Acquired From An Image-Based Spectrometer, Courtney J. Hunter

Biomedical Engineering Undergraduate Honors Theses

A leukocyte differential count can be used to diagnosis a myriad blood disorders, such as infections, allergies, and efficacy of disease treatments. In recent years, attention has been focused on developing point-of-care (POC) systems to provide this test in global health settings. Acridine orange (AO) is an amphipathic, vital dye that intercalates leukocyte nucleic acids and acidic vesicles. It has been utilized by POC systems to identify the three main leukocyte subtypes: granulocytes, monocytes, and lymphocytes. Subtypes of leukocytes can be characterized using a fluorescence microscope, where the AO has a 450 nm excitation wavelength and has two peak emission …


Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron 2017 University of Louisville

Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron

Electronic Theses and Dissertations

Piezo-active composites have been implemented for sensing and transduction for decades. The 0-3 ceramic/polymer composite is one of the most common composite types used for sensing applications, owing to their tailorable properties of the two-phase composition, consisting of a three-dimensionally connected polymer/rubber matrix (inactive phase) with a dispersion of isolated piezo-ceramic particles (active phase). This thesis describes a method to develop novel biocompatible perivascular band comprised of a two-phase piezo-active composite to be fabricated using simple manufacturing processes. Biomaterials such as tissue scaffolds comprised of silk fibroin (SF) and chitosan (CS), and biocompatible soft rubbers will be implemented as the …


Development Of A Directional Bone Reaming System., Richard J Ackermann 2017 University of Louisville

Development Of A Directional Bone Reaming System., Richard J Ackermann

Electronic Theses and Dissertations

Preparation of long bones such as the femur or tibia for placement of intramedullary devices for the treatment of fractures usually involves reaming with a series of central cutters driven by a drill-like device with a flexible shaft over a guide wire. The reamers sequentially enlarge the intramedullary canal into a tunnel of circular cross-section and a diameter appropriate for the procedure. The current technology is concentric, meaning that the system is self-centering within the original intramedullary canal and the expansion is symmetric with respect to the original centerline. A novel system for laterally deflecting the head of a 12mm …


Development Of Peritoneal Microbubble Oxygenation As An Extrapulmonary Treatment For Hypoxia, Nathan Legband 2017 University of Nebraska-Lincoln

Development Of Peritoneal Microbubble Oxygenation As An Extrapulmonary Treatment For Hypoxia, Nathan Legband

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Patients affected by a respiratory disease or injury experience a substantially impaired respiratory system and as a consequence are unable to obtain a sufficient amount of oxygen. Hypoxia can quickly result in developing permanent tissue damage or death. Currently, the medical methods of treating hypoxia are mechanical ventilation or extracorporeal membrane oxygenation. However, these treatments are ineffective in certain cases and possess significant additional risks including barotrauma, infection, hemorrhage, and thrombosis.

The extrapulmonary method of peritoneal oxygenation has been investigated by other research groups as a potential alternative to providing supplemental oxygen in hypoxic animals. In peritoneal oxygenation, the peritoneum, …


Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie 2017 University of Nebraska-Lincoln

Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The invention of capsule endoscopy (CE) made the non-invasive monitoring of the entire small bowel possible and became the primary means for diagnosing small bowel pathology. In the last decade, capsule robots have been transformed from diagnostic devices into a widely studied biomedical platform with the potential for active locomotion, drug delivery and therapeutic capabilities. To perform accurate on-site drug release and therapy, it is necessary for a capsule robot to be able to attach to the intestinal tissue and maintain its position long-term. Design challenges derive from the task of long-term mucosal adhesion which requires firm, quick-response attachment without …


Sensitivity Of Diffuse Reflectance Spectroscopy To Dose- And Depth-Dependent Changes In Tumor Oxygenation After Radiation Therapy, Daria Semeniak 2017 University of Arkansas, Fayetteville

Sensitivity Of Diffuse Reflectance Spectroscopy To Dose- And Depth-Dependent Changes In Tumor Oxygenation After Radiation Therapy, Daria Semeniak

Graduate Theses and Dissertations

Along with chemotherapy, immunotherapy, and surgery, radiotherapy is one of the most common treatments used against cancer. Around 50% of all cancer patients undergo radiation therapy. While for some patients radiotherapy works efficiently and lead to a complete cancer disappearance, for others treatment outcome may be less favorable due to radioresistance processes happening within a tumor on the molecular level. Radioresistance remains a big challenge for modern oncology. The ability to identify radioresistance at the early stage of radiotherapy would help physicians to improve therapy efficiency. At the current moment, despite the rapid progress in cancer understanding and diagnostic modalities, …


Digital Commons powered by bepress