Annuloplasty Mti: Improved Tooling For Annuloplasty Ring Manufacturing,
2018
California Polytechnic State University, San Luis Obispo
Annuloplasty Mti: Improved Tooling For Annuloplasty Ring Manufacturing, Justin David Smith, Spencer Lee Combs, Luke Edward Maly
Mechanical Engineering
The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.
Identification System For Heart Valve Manufacturing,
2018
California Polytechnic State University, San Luis Obispo
Identification System For Heart Valve Manufacturing, Nicholas Robert Jensen, Edgar Davis Nix, Judith Evelyn Gonzalez, Albert Austin Liddicoat
Mechanical Engineering
Abstract withheld due to NDA constraints
Transcatheter Heart Valve Leaflet Assembly Tooling Improvement Final Design Report,
2018
California Polytechnic State University, San Luis Obispo
Transcatheter Heart Valve Leaflet Assembly Tooling Improvement Final Design Report, James Craig Sherman, Zachary Robert Dicks, Luke Edward Williams
Mechanical Engineering
Statement of Confidentiality: The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.
Dynamic Model For Simulating Motion Of The Right Ventricle,
2018
California Polytechnic State University, San Luis Obispo
Dynamic Model For Simulating Motion Of The Right Ventricle, Brian Michael Larsen, Sam Koopman Porter, John Francis D'Ambrosio
Mechanical Engineering
This report documents all the research, ideation, and mockups used to determine right ventricle motion and develop a system capable of reproducing that motion on a tissue sample. The model is intended for evaluating anchoring systems being developed by Edwards Lifesciences for use with tricuspid valve therapies. Several design solutions were considered for the primary functions of recreating motion of the right ventricle and attaching tissue to the device. From these ideas a primary means of producing motion and attaching tissue was selected. These ideas were then developed over the course of a school year to become the final system …
Extended-Use Ecg Monitor,
2018
California Polytechnic State University, San Luis Obispo
Extended-Use Ecg Monitor, Daniel Aaron Soski
Master's Theses
In this thesis, a prototype ECG monitor was developed that is integrated into an elastic shirt and takes a 3-lead ECG for over 5 days. The high-quality measurements can be used to identify markers indicative of various detrimental heart conditions. Measurements recorded by the device are encrypted and stored onto a micro-SD card. Current Holter monitors are expensive and have functional lives less than 48 hours; however, extended duration monitoring has been proven more useful in diagnosis. The device designed demonstrates that ECG measurements can be taken over longer durations without sacrificing quality, comfort, or device cost.
Chemotherapeutic Drug Cytotoxicity Measurement With A 3d Biomimetic Microfluidic Device And Computational Fluid Dynamics Model,
2018
Virginia Polytechnic Institute and State University
Chemotherapeutic Drug Cytotoxicity Measurement With A 3d Biomimetic Microfluidic Device And Computational Fluid Dynamics Model, Maryam Moarefian, Caroline Jones, Luke Achenie, Danesh Tafti
Biology and Medicine Through Mathematics Conference
No abstract provided.
Design Of A Distributed Real-Time E-Health Cyber Ecosystem With Collective Actions: Diagnosis, Dynamic Queueing, And Decision Making,
2018
University of Nebraska-Lincoln
Design Of A Distributed Real-Time E-Health Cyber Ecosystem With Collective Actions: Diagnosis, Dynamic Queueing, And Decision Making, Yanlin Zhou
Department of Electrical and Computer Engineering: Dissertations, Theses, and Student Research
In this thesis, we develop a framework for E-health Cyber Ecosystems, and look into different involved actors. The three interested parties in the ecosystem including patients, doctors, and healthcare providers are discussed in 3 different phases. In Phase 1, machine-learning based modeling and simulation analysis is performed to remotely predict a patient's risk level of having heart diseases in real time. In Phase 2, an online dynamic queueing model is devised to pair doctors with patients having high risk levels (diagnosed in Phase 1) to confirm the risk, and provide help. In Phase 3, a decision making paradigm is proposed …
Design & Delivery Of Automated Winston-Lutz Test For Isocentric & Off-Axis Delivery Stability Utilizing Truebeam Developer Mode & Electronic Portal Imaging Device,
2018
University of Nevada, Las Vegas
Design & Delivery Of Automated Winston-Lutz Test For Isocentric & Off-Axis Delivery Stability Utilizing Truebeam Developer Mode & Electronic Portal Imaging Device, Mahmoud Mohammad Yaqoub
UNLV Theses, Dissertations, Professional Papers, and Capstones
The uncertainties in treatment delivery cannot be ignored in radiation therapy. Thus, the quality assurance QA tests are very important task of the medical physicist in clinical practice. Assuring the coincidence between the mechanical isocenter of the Linear Accelerator (LINAC) and its radiation beams isocenter is one of the most important qualities need to be tested, and the Winston Lust (WL) test is the
most popular technique to perform this task, especially for the treatment modalities which need high precision in beam delivery such as the stereotactic radiosurgery/stereotactic body radiotherapy (SRS/SBRT). The linear accelerator-based SRS/SBRT is a well-established method in …
Design Of A Homeopathic Solution For Chronic Cough,
2018
James Madison University
Design Of A Homeopathic Solution For Chronic Cough, Jacob Ziemke
Senior Honors Projects, 2010-2019
Chronic cough is most commonly defined as a cough that persists for more than eight weeks and is estimated to affect more than 30 million people in the United States at any given time. Diseases contributing to the onset of chronic cough include asthma, pulmonary fibrosis, lung cancer, postnasal drip, gastroesophageal reflux disease (GERD), and bronchitis, and may include lifestyle choices such as smoking. For those who seek medical advice, pharmaceuticals and speech therapy are two common methods of combating chronic cough but serve to mask the symptoms rather than treat the problem; frequently, chronic cough is misdiagnosed or cannot …
Extraction And Analysis Of Vector Flow Imaging Data In A Pediatric Population,
2018
University of Arkansas, Fayetteville
Extraction And Analysis Of Vector Flow Imaging Data In A Pediatric Population, Bailey Stinnett
Biomedical Engineering Undergraduate Honors Theses
Vector flow imaging (VFI) is a new ultrasound technology that provides real time, angle-independent visualization of flow velocities in the heart and great vessels. Thus far, VFI has been used for superficial applications due to the limited penetration depth of available transducer probes; however, this depth in smaller pediatric patients enables adequate aortic views. In this project, VFI was used to study pediatric aortic stenosis (PAS)—a congenital heart defect that results in the narrowing of the aorta and/or aortic valve. The decision to refer PAS patients for surgical or catheter-based intervention is initially based on Doppler ultrasound. VFI is potentially …
Pressure Acquisition System For In Vitro Mitral Valve Analysis,
2018
University of Arkansas, Fayetteville
Pressure Acquisition System For In Vitro Mitral Valve Analysis, Laura Peck
Biomedical Engineering Undergraduate Honors Theses
In vitro testing of the mitral valve chordae tendineae is utilized to aid in the understanding of the stresses that occur in vivo and improve upon surgical solutions that exist for mitral valve repair. This project aimed to design the water control system for a left heart simulation chamber, as well as the pressure acquisition inside the chamber. A solenoid valve was utilized to control the water supply to the tank and was powered utilizing National Instruments software. National Instruments hardware and software was also used with the pressure transducer in order to obtain pressure readings from the chamber. The …
Computational Fluid Dynamics Model For Air Velocity Through A Poultry Transport Trailer In A Holding Shed,
2018
University of Arkansas, Fayetteville
Computational Fluid Dynamics Model For Air Velocity Through A Poultry Transport Trailer In A Holding Shed, Christian Heymsfield
Graduate Theses and Dissertations
Broiler production in Arkansas was valued at over $3.6 billion in 2013 (University of Arkansas Division of Agriculture Cooperative Extension Service). Consequently, improvement in any phase of the production process can have significant economic impact and animal welfare implications. One area of concern for the poultry industry is thermal stress experienced by the birds after arrival at the processing plant and before they are taken in to be processed, during which time they are left to wait in holding sheds. Various cooling strategies exist to mitigate heat stress in holding sheds, but in most cases it is unlikely that they …
Ring And Peg Simulation For Minimally Invasive Surgical Robot,
2018
University of Nebraska-Lincoln
Ring And Peg Simulation For Minimally Invasive Surgical Robot, Evan Brown
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Surgical procedures utilizing minimally invasive laparoscopic techniques have shown less complications, better cosmetic results, and less time in the hospital than conventional surgery. These advantages are partially offset by inherent difficulties of the procedures which include an inverted control scheme, instrument clashing, and loss of triangulation. Surgical robots have been designed to overcome the limitations, the Da Vinci being the most widely used. A dexterous in vivo, two-armed robot, designed to enter an insufflated abdomen with a limited insertion profile and expand to perform a variety of operations, has been created as a less expensive, versatile alternative to the Da …
Development Of A Novel Bioactive Glass Suitable For Osteosarcoma-Related Bone Grafts,
2018
Missouri University of Science and Technology
Development Of A Novel Bioactive Glass Suitable For Osteosarcoma-Related Bone Grafts, Alireza Rahimnejad Yazdi, Lawrence Torkan, Stephen D. Waldman, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
In this study, zinc borate-based glasses with increasing gallium content (0, 2.5, 5, 10, and 15 wt % Ga) were synthesized and their effect on the viability and proliferation of preosteoblasts and osteosarcoma cancer cells were investigated. Methyl thiazolyl tetrazolium (MTT) cell viability assays using glass degradation extracts revealed that the extracts from glasses with lower Ga contents could enhance the viability of preosteoblasts, while extracts from the glass composition with 15 wt % Ga caused statistically significant reduction of their viability. MTT cell viability assays using the extracts and osteosarcoma cells showed that only extracts from the glass composition …
A Strategic Audit Of Medtronic Plc,
2018
University of Nebraska-Lincoln
A Strategic Audit Of Medtronic Plc, Jozzy Carter
Honors Program: Senior Projects (Public)
Humans will always have a need for healthcare, and as the world continues to innovate in the tech space, consumers will demand advances in medicine and medical devices. Medtronic is at the forefront of this innovation but faces intense competition in the medical technologies industry. This poses the question: what can Medtronic do to continue its growth and stay competitive in this space? This paper offers an analysis of Medtronic as a medical device company by offering insight to its competitive advantage, financials, business mix, and value chain. It also analyzes the forces that affect Medtronic using SWOT, PEST, and …
Investigation Of The Effects Of Prosthetic Knee Condition On Novice Transfemoral Amputee Runners,
2018
Marquette University
Investigation Of The Effects Of Prosthetic Knee Condition On Novice Transfemoral Amputee Runners, Natalie Nelson
Master's Theses (2009 -)
Some unilateral transfemoral amputees (TFAs) run in a prosthesis with an articulating prosthetic knee, others choose to run without a knee (prosthetic socket and foot are linked via a straight, non-articulating pylon) to increase stability. Research regarding unilateral TFA running with an unlocked versus locked prosthetic knee (approximately equivalent to the no-knee condition) with respect to energy cost and temporal metrics is limited; no studies have investigated the impact of knee condition on kinematic metrics. The purpose of this study was to investigate whether the prosthetic knee of a running-specific prosthesis (RSP) should be unlocked or locked for unilateral TFAs …
Design And Development Of A Multifunctional Surgical Device For Ground And Space-Based Surgical Applications.,
2018
University of Louisville
Design And Development Of A Multifunctional Surgical Device For Ground And Space-Based Surgical Applications., Brooke Elaine Barrow
Electronic Theses and Dissertations
With the possibility of longer ventures into space, NASA will face many new medical challenges. The ability to surgically treat trauma and other disorders in reduced gravity requires reliable wound access, containment, and visualization. In collaboration with Carnegie Mellon University, the University of Louisville is currently developing the AISS (Aqueous Immersion Surgical System) to increase efficiency and control of the operative field in space-based surgeries. Reliable wound access and containment is achieved by placing a transparent wound-isolation dome securely over the wound-site and pressurizing it with a saline solution. Leak-free trocars provide access ports for various surgical instruments. This system …
Optimization Of Microfluidic Chip Fabrication Via Femtosecond Laser Ablation,
2018
University of South Carolina
Optimization Of Microfluidic Chip Fabrication Via Femtosecond Laser Ablation, Kenneth Aycock
Senior Theses
Microfluidic devices have become staple tools in biomedical research and have a promising future as low cost, point-of-care (POC) diagnostic devices. Despite the advancements in microfluidic device technology, the manipulation and fabrication of these systems can be tedious and expensive. Repeatable techniques in which computer-aided designs are translated into microfluidic systems in a matter of minutes are highly desirable both for researchers and manufacturers. Laser ablation of tape substrates has shown promise in producing cost-effective, rapidly manipulable devices, but the work done thus far has utilized continuous wave lasers that perform suboptimally due to the relatively short wavelengths used and …
Development Of Rule-Based Recognition Systems For Continuous Monitorization Of Pulse Oximetry,
2018
University of South Carolina - Columbia
Development Of Rule-Based Recognition Systems For Continuous Monitorization Of Pulse Oximetry, Brian Delehanty
Senior Theses
Pulse Oximeters provide a convenient, non-invasive method to quickly gather information about a patient's pulse rate (PR) and arterial blood oxygen saturation (SpO2). Many pulse oximeters lack alert systems that notify caregivers if a patient's readings go outside the healthy range, and pulse oximeters that have these mechanisms are significantly more expensive. This project set out to write a program using LabVIEW that collects pulse oximeter data via Bluetooth and generates an alert when readings persist in the abnormal range for more than fifteen seconds. Due to privacy laws that allow pulse oximeter manufacturers to not disclose the …
Virtual Stethoscope/Otoscope Duo,
2018
California Polytechnic State University, San Luis Obispo
Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro
Biomedical Engineering
The virtual stethoscope/otoscope duo is a medical device intended to allow patients to be seen by their medical provider via internet consultations from the comfort of their own home. This device allows patients to substitute in-person doctor visits by checking a patient’s cardiovascular, respiratory, and auditory health. This document is the statement of work for the virtual stethoscope/otoscope duo and contains information on similar products, patents, and relevant literatures containing virtual technologies that assist in patient diagnosis. Product specifications and other details for the device such as performance evaluation review techniques can also be found within this document outlining the …