Optimization Of Microfluidic Chip Fabrication Via Femtosecond Laser Ablation, Kenneth Aycock 2018 University of South Carolina

Optimization Of Microfluidic Chip Fabrication Via Femtosecond Laser Ablation, Kenneth Aycock

Senior Theses

Microfluidic devices have become staple tools in biomedical research and have a promising future as low cost, point-of-care (POC) diagnostic devices. Despite the advancements in microfluidic device technology, the manipulation and fabrication of these systems can be tedious and expensive. Repeatable techniques in which computer-aided designs are translated into microfluidic systems in a matter of minutes are highly desirable both for researchers and manufacturers. Laser ablation of tape substrates has shown promise in producing cost-effective, rapidly manipulable devices, but the work done thus far has utilized continuous wave lasers that perform suboptimally due to the relatively short wavelengths used and …


Design And Development Of A Multifunctional Surgical Device For Ground And Space-Based Surgical Applications., Brooke Elaine Barrow 2018 University of Louisville

Design And Development Of A Multifunctional Surgical Device For Ground And Space-Based Surgical Applications., Brooke Elaine Barrow

Electronic Theses and Dissertations

With the possibility of longer ventures into space, NASA will face many new medical challenges. The ability to surgically treat trauma and other disorders in reduced gravity requires reliable wound access, containment, and visualization. In collaboration with Carnegie Mellon University, the University of Louisville is currently developing the AISS (Aqueous Immersion Surgical System) to increase efficiency and control of the operative field in space-based surgeries. Reliable wound access and containment is achieved by placing a transparent wound-isolation dome securely over the wound-site and pressurizing it with a saline solution. Leak-free trocars provide access ports for various surgical instruments. This system …


A Strategic Audit Of Medtronic Plc, Jozzy Carter 2018 University of Nebraska-Lincoln

A Strategic Audit Of Medtronic Plc, Jozzy Carter

Honors Program: Senior Projects (Public)

Humans will always have a need for healthcare, and as the world continues to innovate in the tech space, consumers will demand advances in medicine and medical devices. Medtronic is at the forefront of this innovation but faces intense competition in the medical technologies industry. This poses the question: what can Medtronic do to continue its growth and stay competitive in this space? This paper offers an analysis of Medtronic as a medical device company by offering insight to its competitive advantage, financials, business mix, and value chain. It also analyzes the forces that affect Medtronic using SWOT, PEST, and …


Development Of A Novel Bioactive Glass Suitable For Osteosarcoma-Related Bone Grafts, Alireza Rahimnejad Yazdi, Lawrence Torkan, Stephen D. Waldman, Mark R. Towler 2018 Missouri University of Science and Technology

Development Of A Novel Bioactive Glass Suitable For Osteosarcoma-Related Bone Grafts, Alireza Rahimnejad Yazdi, Lawrence Torkan, Stephen D. Waldman, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

In this study, zinc borate-based glasses with increasing gallium content (0, 2.5, 5, 10, and 15 wt % Ga) were synthesized and their effect on the viability and proliferation of preosteoblasts and osteosarcoma cancer cells were investigated. Methyl thiazolyl tetrazolium (MTT) cell viability assays using glass degradation extracts revealed that the extracts from glasses with lower Ga contents could enhance the viability of preosteoblasts, while extracts from the glass composition with 15 wt % Ga caused statistically significant reduction of their viability. MTT cell viability assays using the extracts and osteosarcoma cells showed that only extracts from the glass composition …


Investigation Of The Effects Of Prosthetic Knee Condition On Novice Transfemoral Amputee Runners, Natalie Nelson 2018 Marquette University

Investigation Of The Effects Of Prosthetic Knee Condition On Novice Transfemoral Amputee Runners, Natalie Nelson

Master's Theses (2009 -)

Some unilateral transfemoral amputees (TFAs) run in a prosthesis with an articulating prosthetic knee, others choose to run without a knee (prosthetic socket and foot are linked via a straight, non-articulating pylon) to increase stability. Research regarding unilateral TFA running with an unlocked versus locked prosthetic knee (approximately equivalent to the no-knee condition) with respect to energy cost and temporal metrics is limited; no studies have investigated the impact of knee condition on kinematic metrics. The purpose of this study was to investigate whether the prosthetic knee of a running-specific prosthesis (RSP) should be unlocked or locked for unilateral TFAs …


Injectable Glass Polyalkenoate Cements: Evaluation Of Their Rheological And Mechanical Properties With And Without The Incorporation Of Lidocaine Hydrochloride, P. Niranjan, A. Alhalawani, S. Phull, I. Beniluz, B. Krishnan, P. Zalzal, Mark R. Towler 2018 Missouri University of Science and Technology

Injectable Glass Polyalkenoate Cements: Evaluation Of Their Rheological And Mechanical Properties With And Without The Incorporation Of Lidocaine Hydrochloride, P. Niranjan, A. Alhalawani, S. Phull, I. Beniluz, B. Krishnan, P. Zalzal, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Lidocaine hydrochloride is used as an anesthetic in many clinical applications. This short communication investigates the effect of complete substitution of lidocaine hydrochloride for deionized (DI) water on the physico-chemical properties of two novel glass polyalkenoate cements. Substituting DI water with lidocaine hydrochloride resulted in cements with shorter working times but comparable setting times and mechanical properties. Fourier transform infrared spectroscopy confirmed that the setting reaction in cements containing DI water and lidocaine hydrochloride was completed within 24 h, post cement preparation and maturation. Further, it was explained that lidocaine hydrochloride binds to poly(acrylic) acid (PAA) due to electrostatic forces …


Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro 2018 California Polytechnic State University, San Luis Obispo

Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro

Biomedical Engineering

The virtual stethoscope/otoscope duo is a medical device intended to allow patients to be seen by their medical provider via internet consultations from the comfort of their own home. This device allows patients to substitute in-person doctor visits by checking a patient’s cardiovascular, respiratory, and auditory health. This document is the statement of work for the virtual stethoscope/otoscope duo and contains information on similar products, patents, and relevant literatures containing virtual technologies that assist in patient diagnosis. Product specifications and other details for the device such as performance evaluation review techniques can also be found within this document outlining the …


The Effect Of Mg²⁺ Incorporation Into The Glass Phase Of Zinc-Based Glass Polyalkenoate Cements, Basel A. Khader, Omar Rodriguez, Mark R. Towler 2018 Missouri University of Science and Technology

The Effect Of Mg²⁺ Incorporation Into The Glass Phase Of Zinc-Based Glass Polyalkenoate Cements, Basel A. Khader, Omar Rodriguez, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

The suitability of glass polyalkenoate cements (GPCs) as injectable adhesives in orthopedics have been compromised by the presence of aluminum (Al), a component in the glass phase of all commercial GPCs. There has been considerable work on the development of Al-free GPCs which can be formulated based on calcium (Ca) zinc (Zn) silicate (Si) glasses. These materials, in terms of biocompatibility and mechanical properties, have potential for orthopedics. However, many of these experimental Al-free GPCs have setting times shorter than 60 s, restricting clinical applications. Here, the authors incorporate Magnesium (Mg) into the glass phase of Al-free GPCs in an …


Microfluidic Technology And Application In Urinal Analysis, Jiwen Xiang 2018 Louisiana State University and Agricultural and Mechanical College

Microfluidic Technology And Application In Urinal Analysis, Jiwen Xiang

LSU Doctoral Dissertations

Microfluidic technology offers numerous advantages in minimizing and integrating the traditional assays. However, the lack of efficient control components of the microfluidic systems has been hindering the widely commercialization of the technology. The research work in this dissertation focused on the development of effective control components for microfluidic applications.

A linear peristaltic pump was firstly designed, fabricated, and tested for conventional microfluidics by synchronously compressing the microfluidic channel with a miniature cam-follower system in Chapter 2. The miniature cam-follower system and microfluidic chip was prototyped using three-dimensional (3D) printing technology and soft lithography technology. Results from experimental test showed that …


Raman Spectroscopy Predicts The Link Between Claw Keratin And Bone Collagen Structure In A Rodent Model Of Oestrogen Deficiency, M. Clare Caraher, Antonia Sophocleous, J. Renwick Beattie, Olive O'Driscoll, Niamh M. Cummins, Orlaith Brennan, Fergal J. O'Brien, Stuart H. Ralston, Steven E.J. Bell, Mark R. Towler, Aymen I. Idris 2018 Missouri University of Science and Technology

Raman Spectroscopy Predicts The Link Between Claw Keratin And Bone Collagen Structure In A Rodent Model Of Oestrogen Deficiency, M. Clare Caraher, Antonia Sophocleous, J. Renwick Beattie, Olive O'Driscoll, Niamh M. Cummins, Orlaith Brennan, Fergal J. O'Brien, Stuart H. Ralston, Steven E.J. Bell, Mark R. Towler, Aymen I. Idris

Chemical and Biochemical Engineering Faculty Research & Creative Works

Osteoporosis is a common disease characterized by reduced bone mass and an increased risk of fragility fractures. Low bone mineral density is known to significantly increase the risk of osteoporotic fractures; however, the majority of non-traumatic fractures occur in individuals with a bone mineral density too high to be classified as osteoporotic. Therefore, there is an urgent need to investigate aspects of bone health, other than bone mass, that can predict the risk of fracture. Here, we successfully predicted association between bone collagen and nail keratin in relation to bone loss due to oestrogen deficiency using Raman spectroscopy. Raman signal …


Low Cost Waist Line Circumference Health Management Belt, Raghav Talreja 2018 Wayne State University

Low Cost Waist Line Circumference Health Management Belt, Raghav Talreja

Research Opportunities for Engineering Undergraduates (ROEU) Program 2017-18

One third of the American population is obese or near obese, and $150 billion is spent in weight management. Current devices to monitor weight are expensive, and niche products are designed for health enthusiasts. This project investigates user needs, development and commercialization steps for a low cost health management belt.


Preparation For The Study Of Gene Expression Aboard The International Space Station, Amber Paturzo 2018 STAR Program

Preparation For The Study Of Gene Expression Aboard The International Space Station, Amber Paturzo

STAR Program Research Presentations

WetLab-2 performs quantitative polymerase chain reaction (qPCR) aboard the micro-gravity environment of the International Space Station in order to research how the stress of micro-gravity affects an organism’s RNA production and gene expression. This on-station qPCR allows researchers to gather information earlier and thereby allow them to modify experiments in a matter of hours rather than wait until the next flight opportunity. After a successful validation flight on SpaceX-8 and follow-up investigation on SpaceX-9, system components must now be adjusted for a new type of biological sample. Specifically, the WetLab-2 facility includes a commercial qPCR instrument (RNA SmartCycler), a sample …


Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan 2018 University of Denver

Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan

Electronic Theses and Dissertations

EPR is a powerful biophysical tool that can be used to measure tumor physiology. With the addition of magnetic field gradients, the spectral properties of paramagnetic species can be mapped. To facilitate EPR imaging, methods and instrumentation at frequencies between 250 MHz and 1 GHz were developed.

At low spin concentrations, the rapid scan background signal is often many times larger than the EPR signal of interest. To help remove the background contribution, a data acquisition procedure that takes advantage of a cross-loop resonator and bipolar power supplies was developed at 250 MHz. In this procedure, two scans are collected. …


The Effect Of Cognitive Limb Embodiment On Vascular Physiological Response, Hala Elsir mustafa Osman 2018 Cleveland State University

The Effect Of Cognitive Limb Embodiment On Vascular Physiological Response, Hala Elsir Mustafa Osman

ETD Archive

The rubber hand illusion (RHI) is a visual-tactile perceptual illusion commonly used to study body ownership. In this paradigm, a rubber hand is positioned in front of a participant, and the person’s real hand is hidden from sight behind a barrier. When the real hand and the rubber hand are stroked synchronously, individuals perceive the rubber hand as if it were their own; it becomes “embodied.” This illusory experience of body ownership is associated with multimodal integration of touch and vision. From these visual-tactile-cognitive mechanisms, we establish that our hands belong to us when what we see matches what we …


Stabilization Of Hypoxia Inducible Factor By Cobalt Chloride Can Alter Renal Transepithelial, Subhra Sankar Nag 2018 Cleveland State University

Stabilization Of Hypoxia Inducible Factor By Cobalt Chloride Can Alter Renal Transepithelial, Subhra Sankar Nag

ETD Archive

Kidney cyst expansion, stagnant fluid accumulation, and insufficient vascular supply can result in localized chronic ischemia-hypoxia in kidney cysts, as well as in normal renal epithelia adjacent to a cyst. We hypothesize that in normal epithelia near a cyst, the stabilization of Hypoxia Inducible Factor 1a (HIF1a), a major regulator of cellular response to hypoxia, can cause altered paracellular and transcellular transport, transforming a normal absorptive phenotype to a secretory and paracellularly leaky phenotype, leading to cyst expansion. Using 100 µmol/L cobalt chloride (CoCl2), HIF1a was stabilized in cellular nucleus of a mouse cortical collecting duct cell line (mCCD 1296 …


A Machine Learning Approach To Assess The Separation Of Seismocardiographic Signals By Respiration, Brian Solar 2018 University of Central Florida

A Machine Learning Approach To Assess The Separation Of Seismocardiographic Signals By Respiration, Brian Solar

Honors Undergraduate Theses

The clinical usage of Seismocardiography (SCG) is increasing as it is being shown to be an effective non-invasive measurement for heart monitoring. SCG measures the vibrational activity at the chest surface and applications include non-invasive assessment of myocardial contractility and systolic time intervals. Respiratory activity can also affect the SCG signal by changing the hemodynamic characteristics of cardiac activity and displacing the position of the heart. Other clinically significant information, such as systolic time intervals, can thus manifest themselves differently in an SCG signal during inspiration and expiration. Grouping SCG signals into their respective respiratory cycle can mitigate this issue. …


Electrochemical And Spectroscopic Study Of Peptide-Template Melanins, Daniel Courter, Olivia Rossi, Zhen Tian 2018 University of New Hampshire, Durham

Electrochemical And Spectroscopic Study Of Peptide-Template Melanins, Daniel Courter, Olivia Rossi, Zhen Tian

Honors Theses and Capstones

Melanins are organic polymers made up of 5,6-dihydroxyindole carboxylic acid (DHICA) and 5,6-dihydroxyindole (DHI). Biochemical systems synthesize melanins through a complex reaction pathway. Previous research exhibited that naturally-occurring melanins (NatMel) and their synthetic analogues (SynMel) can potentially serve as electrode materials for aqueous charge storage devices. Small surface area creates technical challenges for these melanins as charge storage materials. This research herein demonstrates that the structure of melanins can affect the charge storage capacities of monovalent Na+cations and divalent Mg2+ cations. 2-D sheet-like peptide melanins (PepMel) were synthesized into tripeptides consisting of aspartic acid (D), phenylalanine (F), …


Power Mobility Sensor Data Collection Verified Through Standardized Pediatric Assessments, Ayshka Elise Rodriguez-Velez 2018 University of North Florida

Power Mobility Sensor Data Collection Verified Through Standardized Pediatric Assessments, Ayshka Elise Rodriguez-Velez

UNF Graduate Theses and Dissertations

The collaboration between the School of Engineering and the Department of Physical Therapy at the University of North Florida has introduced the possibility of creating a new environment for pediatric physical therapy assessments. There are currently no methods for remotely monitoring children with impairments. However, with embedded sensor technology in the form of power mobility and accepted therapy assessment tools, remote monitoring can become a possibility. As a part of this work, a ride-on toy car was developed as a remote monitoring device and a case study with a child with a mobility impairment was used as a proof of …


Multimodal Noncontact Diffuse Optical Reflectance Imaging Of Blood Flow And Fluorescence Contrasts, Daniel Irwin 2018 University of Kentucky

Multimodal Noncontact Diffuse Optical Reflectance Imaging Of Blood Flow And Fluorescence Contrasts, Daniel Irwin

Theses and Dissertations--Biomedical Engineering

In this study we design a succession of three increasingly adept diffuse optical devices towards the simultaneous 3D imaging of blood flow and fluorescence contrasts in relatively deep tissues. These metrics together can provide future insights into the relationship between blood flow distributions and fluorescent or fluorescently tagged agents. A noncontact diffuse correlation tomography (ncDCT) device was firstly developed to recover flow by mechanically scanning a lens-based apparatus across the sample. The novel flow reconstruction technique and measuring boundary curvature were advanced in tandem. The establishment of CCD camera detection with a high sampling density and flow recovery by speckle …


Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson 2018 University of Kentucky

Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson

Theses and Dissertations--Mechanical and Aerospace Engineering

This thesis proposes an algorithm that determine the geometry of 3D-printed, custom-designed spring element bands made of thermoplastic elastomer (TPE) for use in a wearable orthotic device to aid in the physical therapy of a human hand exhibiting spasticity after stroke. Each finger of the hand is modeled as a mechanical system consisting of a triple-rod pendulum with nonlinear stiffness at each joint and forces applied at the attachment point of each flexor muscle. The system is assumed quasi-static, which leads to a torque balance between the flexor tendons in the hand, joint stiffness and the design force applied to …