Reducing Uncertainty In Head And Neck Radiotherapy With Plastic Robotics,
2018
Virginia Commonwealth University
Reducing Uncertainty In Head And Neck Radiotherapy With Plastic Robotics, Mark R. Ostyn
Theses and Dissertations
One of the greatest challenges in achieving accurate positioning in head and neck radiotherapy is that the anatomy at and above the cervical spine does not act as a single, mechanically rigid body. Current immobilization techniques contain residual uncertainties that are especially present in the lower neck that cannot be reduced by setting up to any single landmark. The work presented describes the development of a radiotherapy friendly mostly-plastic 6D robotic platform for positioning independent landmarks, (i.e., allowing remote, independent positioning of the skull relative to landmarks in the thorax), including analysis of kinematics, stress, radiographic compatibility, trajectory planning, physical …
Review Of Emerging Approaches In Non- Or Minimally Invasive Glucose Monitoring And Their Application To Physiological Human Body Fluids,
2018
CUNY New York City College of Technology
Review Of Emerging Approaches In Non- Or Minimally Invasive Glucose Monitoring And Their Application To Physiological Human Body Fluids, Sunghoon Jang, Chen Xu
Publications and Research
The frequent blood glucose monitoring by the diabetics and physicians is a very essential step in the management of the diabetes because this devastating disease can lead the patients to blindness, kidney disease, nervous & circulatory system disease, limb amputations, stroke and cardiovascular disease (CVD). There have been numerous attempts to develop viable painless non- or minimally invasive blood glucose monitoring techniques over the last five decades in order to replace all existing methods of home blood glucose monitoring require drawing a blood sample by piercing the skin. This review describes the principles of two main emerging general technologies such …
A Novel Approach To Assess Minimally Invasive Surgical Device Failure Utilizing Adverse Event Outcome Severity And Design Complexity.,
2017
University of Louisville
A Novel Approach To Assess Minimally Invasive Surgical Device Failure Utilizing Adverse Event Outcome Severity And Design Complexity., Marie K. Riggs
Electronic Theses and Dissertations
Medical device failure and misuse have the potential to cause serious injury and death. Given the intricate nature of the instruments utilized specifically in minimally invasive surgery (MIS), users and manufacturers of surgical devices share a responsibility in preventing user error and device failure. A novel approach was presented for the evaluation of minimally invasive device failures, which involved assessing the severity of adverse event outcomes associated with the failures modes and investigating aspects of the devices’ design that may contribute to failure. The goals of this research were to 1) characterize the design attributes, failure modes, and adverse events …
Eeg Characterization During Motor Tasks That Are Difficult For Movement Disorder Patients,
2017
California Polytechnic State University, San Luis Obispo
Eeg Characterization During Motor Tasks That Are Difficult For Movement Disorder Patients, Adam Joshua Aslam
Master's Theses
Movement disorders are a group of syndromes that often arise due to neurological abnormalities. Approximately 40 million Americans are affected by some form of movement disorder, significantly impacting patients’ quality of life and their ability to live independently. Deep brain stimulation (DBS) is one treatment that has shown promising results in the past couple decades, however, the currently used open-loop system has several drawbacks. By implementing a closed-loop or adaptive DBS (aDBS) system, the need for expensive parameter reprogramming sessions would be reduced, side-effects may be relieved, and habituation could be avoided. Several biomarkers, for example signals or activity derived …
Design, Development, And Characterization Of Breathforce : A Respiratory Training System For Patients With Spinal Cord Injuries.,
2017
University of Louisville
Design, Development, And Characterization Of Breathforce : A Respiratory Training System For Patients With Spinal Cord Injuries., Kevin L Tran
Electronic Theses and Dissertations
Pulmonary and cardiovascular dysfunction are consistently reported as the leading causes of morbidity and mortality among the 1,275,000 people who are living with chronic spinal cord injury (SCI) in the United States. Respiratory-cardiovascular complications from neurological disorders (primarily COPD and sleep apnea) are currently the number one cause of death and disability in the US.
The main goal of this project is to develop an inspiratory-expiratory training device for use in the rehabilitation of patients with respiratory motor and cardiovascular deficits that incorporates existing technologies and promotes successful training methodologies performed at the clinic and at home.
An embedded microprocessor …
Development Of In-Vitro And In-Vivo Devices To Study The Mechanobiology Of Ligament Healing,
2017
Boise State University
Development Of In-Vitro And In-Vivo Devices To Study The Mechanobiology Of Ligament Healing, John Bayard Everingham
Boise State University Theses and Dissertations
Ligament injuries are the most common sports injury in the United States. The current clinical practice for treating ligament injuries leaves many patients with significant pain and joint laxity for years following the initial injury. Controlled mechanical stimulation of the tissue after injury is necessary for robust healing, but the optimal mechanical environment for ligament healing is not fully understood. Alternative therapies, such as instrument assisted soft tissue mobilization (IASTM), offer a form of mechanical stimulation that is non-invasive and has shown promising clinical outcomes but the optimal dosage for IASTM treatments is unknown. The objective of this study was …
Development Of Biomimetic Membrane Assemblies On Microspheres For High-Throughput And Multiplexable Studies,
2017
University of New Mexico
Development Of Biomimetic Membrane Assemblies On Microspheres For High-Throughput And Multiplexable Studies, Nadiezda P. Fernandez Oropeza
Biomedical Engineering ETDs
Membranes and membrane-associated components are the target of approximately 60% of the current drugs, of synthetic materials, such as polymers, which are used for drug delivery purposes and of other biomolecules, such as endotoxins, which gain entry into the cell by disrupting the membrane. Therefore, the development of biomimetic membrane assemblies allows the study of different biological processes in which cell membranes play an important role, and the characterization and screening of drug delivery tools and other membrane-bound components.
Since its development, membrane assemblies on planar silica surfaces have been the method of choice to study membrane-associated and membrane-bound components. …
Titanium Addition Influences Antibacterial Activity Of Bioactive Glass Coatings On Metallic Implants,
2017
Missouri University of Science and Technology
Titanium Addition Influences Antibacterial Activity Of Bioactive Glass Coatings On Metallic Implants, Omar Rodriguez, Wendy Stone, Emil H. Schemitsch, Paul Zalzal, Stephen Waldman, Marcello Papini, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
In an attempt to combat the possibility of bacterial infection and insufficient bone growth around metallic, surgical implants, bioactive glasses may be employed as coatings. In this work, silica-based and borate-based glass series were synthesized for this purpose and subsequently characterized in terms of antibacterial behavior, solubility and cytotoxicity. Borate-based glasses were found to exhibit significantly superior antibacterial properties and increased solubility compared to their silica-based counterparts, with BRT0 and BRT3 (borate-based glasses with 0 and 15 mol% of titanium dioxide incorporated, respectively) outperforming the remainder of the glasses, both borate and silicate based, in these respects. Atomic Absorption Spectroscopy …
Collapsible Silicone Tubes: An In Vitro Model For Tracheal Traction,
2017
Marquette University
Collapsible Silicone Tubes: An In Vitro Model For Tracheal Traction, Kevin D. Garman
Master's Theses (2009 -)
Obstructive sleep apnea (OSA) is characterized by recurrent episodes of airway collapse and airflow limitation during sleep. Fragmented sleep and reductions in blood oxygen saturation lead to several comorbidities, including hypertension, cardiovascular disease, and cerebrovascular disease. Longitudinal forces (tracheal traction) acting on the soft tissues surrounding the upper airway have been proposed to play a significant role in stabilizing the airway and preventing collapse. However, the relative contribution of longitudinal forces as compared to other factors that affect airway stability (airway geometry, tissue properties, muscle activity) remains unclear. This in-vitro study aimed to investigate to what extent longitudinal forces can …
Effects Of Random Oscillations On Balance Control In Healthy Young Adults,
2017
Marquette University
Effects Of Random Oscillations On Balance Control In Healthy Young Adults, Jacob Van Dehy
Master's Theses (2009 -)
In human walking, balance control is managed through proactive changes in spatio-temporal parameters of stepping [1]. It has been suggested that continuous disruptions to healthy young adult balance cause greater changes to overall variability of these parameters than a shift in the mean stepping parameters [2]. This suggests that walking may be occurring in a more reactive manner, modulating to maintain balance without increasing the mean significantly. Work using continuous oscillations to treadmill walking suggest there is an interplay between the predictability of a signal used to disrupt subject balance and the degree to which compensation occurs [3]. To determine …
Thermally Assisted Pulsed Electric Field Ablation For Cancer Therapy,
2017
Old Dominion University
Thermally Assisted Pulsed Electric Field Ablation For Cancer Therapy, James Michael Hornef
Biomedical Engineering Theses & Dissertations
Pulsed Electric Fields (PEF) have promised improved treatment results in a variety of cancer types including melanoma, pancreatic and lung squamous cancer. Recent studies show that PEF-based cancer therapy may be improved further with the assistance of moderate heating of the target. Experiments were performed to design, calibrate and implement a feedback-looped infrared laser irradiation system that could maintain specified temperatures during the treatment. The exact treatment area, penetration depth and thermal distribution of a 980-nm laser fiber were quantified using several methods, including the knife-edge technique and a tissue optical property study. In vivo and in vitro experiments using …
Potency And Cytotoxicity Of A Novel Gallium-Containing Mesoporous Bioactive Glass/Chitosan Composite Scaffold As Hemostatic Agents,
2017
Missouri University of Science and Technology
Potency And Cytotoxicity Of A Novel Gallium-Containing Mesoporous Bioactive Glass/Chitosan Composite Scaffold As Hemostatic Agents, Sara Pourshahrestani, Ehsan Zeimaran, Nahrizul Adib Kadri, Nicola Gargiulo, Hassan Mahmood Jindal, Sangeetha Vasudevaraj Naveen, Shamala Devi Sekaran, Tunku Kamarul, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Chitosan-based hemostats are promising candidates for immediate hemorrhage control. However, they have some disadvantages and require further improvement to achieve the desired hemostatic efficiency. Here, a series of 1% Ga2O3-containing mesoporous bioactive glass-chitosan composite scaffolds (Ga-MBG/CHT) were constructed by the lyophilization process and the effect of various concentrations of Ga-MBG (10, 30, and 50 wt %) on the hemostatic function of the CHT scaffold was assessed as compared to that of Celox Rapid gauze (CXR), a current commercially available chitosan-coated hemostatic gauze. The prepared scaffolds exhibited >79% porosity and showed increased water uptake compared to that in CXR. The results …
Gui For Mri-Compatible Neural Stimulator And Recorder,
2017
Purdue University
Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu
The Summer Undergraduate Research Fellowship (SURF) Symposium
Functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) are useful tools to analyze brain activities given active stimulation. However, the electromagnetic noise from the MRI distorts the brain signal recording and damages the subject with excessive heat generated on the electrodes attached to the skin. MRI-compatible recording and stimulation systems previously developed at LIBI lab were capable of removing the electromagnetic noise during the imaging process. Previously, the hardware systems had required the integrative software that could control both circuits simultaneously and enable users to easily change recording and stimulation parameters. Graphical user interface (GUI) programmed with computer language informed …
Low Power, Low Noise Circuit For Biological Signal Recording,
2017
Purdue University
Low Power, Low Noise Circuit For Biological Signal Recording, Rachael A. Swenson, Daniel J. Pederson, Pedro Irazoqui
The Summer Undergraduate Research Fellowship (SURF) Symposium
Implantable devices are ideal for recording biological signals in animal models as they have minimal effect on the animal’s normal behavior during observation. The creation of the circuitry for an implantable device has several restrictions including size, power consumption, and noise reduction. These factors compete against each other, making it necessary to carefully optimize circuit components for a given application. This study evaluates the design of a four-channel analog front end circuit board to record cardiac, neural, and respiratory biological signals. Through a critical analysis of component specifications for the circuit’s components and an evaluation of the circuits’ power and …
Co-Modulation Masking Release Begins In The Auditory Periphery,
2017
Purdue University
Co-Modulation Masking Release Begins In The Auditory Periphery, Kareem R. Hussein, Agudemu Borjigan, Mark Sayles
The Summer Undergraduate Research Fellowship (SURF) Symposium
Understanding speech in noisy environments can be difficult, especially for people with hearing loss. The background noise can cover up the sounds of interest. Normally, the auditory system works to alleviate this problem by tagging and then cancelling the noise. Our experiments are aimed at understanding the mechanism of this noise cancellation process. We hypothesize that non-linear signal processing in the mammalian cochlea (the most peripheral part of the auditory system) is the basis of noise cancellation. To test this hypothesis, we measured the responses of auditory-nerve fibers (ANFs) to sounds embedded in background noise with different statistical properties. ANFs …
Pathogenic Dna Detection Using Dna Hairpins: A Non-Linear Hybridization Chain Reaction Platform,
2017
Purdue University
Pathogenic Dna Detection Using Dna Hairpins: A Non-Linear Hybridization Chain Reaction Platform, Lance Novak, Tamara L. Kinzer-Ursem
The Summer Undergraduate Research Fellowship (SURF) Symposium
Currently, 3.2 billion people are at risk of being infected with malaria, with 1.2 billion of those being at high risk (>1 in 1000 chance of getting malaria in a year). Thus, there is a need for a biosensor that is highly sensitive, cost effective, and simple to use for point-of-care diagnosis. The biosensing platform, PathVis, has achieved this by measuring changes in fluid properties after a loop-mediated isothermal amplification (LAMP). LAMP is a DNA amplification system that requires enzymes and a temperature of 65degrees C. LAMP currently limits PathVis by being costly, requiring refrigeration, and difficult to design. …
A Chronically Implanted, Continuous Ph Monitoring System For Rats,
2017
Purdue University
A Chronically Implanted, Continuous Ph Monitoring System For Rats, Ryan B. Budde, Pedro P. Irazoqui
The Summer Undergraduate Research Fellowship (SURF) Symposium
Many body systems operate within a strict pH range, and any deviation can cause harm. pH measurement systems are used in many biomedical research fields. Measurement systems have been able to continuously record pH for a short period of time wirelessly, or over a long period of time with wires, but no system is currently capable of long term, wireless, continuous pH recording. This paper proposes a new pH measurement system that is capable of such measurement. The system is composed of inexpensive, micro-scale, and easy to manufacture pH sensitive and reference electrodes and a data acquisition and transmission module …
Localized Blood Occlusion Generation In An In-Vitro Circulatory Catheter System,
2017
Purdue University
Localized Blood Occlusion Generation In An In-Vitro Circulatory Catheter System, Ryan D. Harris, Qi Yang, Hyowon Lee
The Summer Undergraduate Research Fellowship (SURF) Symposium
Hydrocephalus is a debilitating neurological disorder that involves the accumulation of cerebrospinal fluid in a ventricle of the brain. The implantation of a catheter commonly treats hydrocephalus with drainage. These catheters have a short lifespan due to obstruction from biological materials. Shunt systems have an extremely high failure rate of more than 40% failed within 1 year and up to 85% failed within 10 years. Previously, polymer-based flexible implantable magnetic micro-actuators were developed to clean up the catheter by mechanical vibration. We have demonstrated clearing of bacteria attachment and are proceeding to examine clearing effects on larger clotting materials, such …
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur.,
2017
University of Louisville
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Electronic Theses and Dissertations
Based on the principles of cutting edge bone remodeling research, a unique therapeutic exercise device was designed specifically to improve bone quality at the most critical location of the proximal femur prone to fracture: the superior-lateral femoral neck where the fracture first initiates during a fall. The exercise/device is intended to work by inducing enough strain in the bone to stimulate the body’s natural bone remodeling mechanisms to increase bone density in the proximal femur and consequently prevent a fracture from arising if a fall to the side does occur.
In order to test the proposed exercise, experiments simulating the …
Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility,
2017
University of Nevada, Las Vegas
Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris
UNLV Theses, Dissertations, Professional Papers, and Capstones
It has been demonstrated that although many varieties of upper limb prosthetics exist, commercially available prosthetics are outdated and unsatisfactory. Ineffectiveness and limitations have led to some prosthesis wearers having to own multiple devices, whereas others have given up on them entirely. Even though ample research has been conducted to design and test new hand designs, the industry appears to rest in an overall stagnated state.
It was proposed here, that one problem with prosthetic research is an excess of variables involved in testing, and therefore the improper application of the scientific method. It seems that each time a research …
