Open Access. Powered by Scholars. Published by Universities.®

Biomedical Devices and Instrumentation Commons™

Open Access. Powered by Scholars. Published by Universities.®

1,153 Full-Text Articles 2,226 Authors 606,459 Downloads 124 Institutions

All Articles in Biomedical Devices and Instrumentation

Faceted Search

1,153 full-text articles. Page 54 of 54.

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle 2010 Technological University Dublin

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


Influence Of Morphology And Processing On Xps Characterisation Of Sro-Ca-Zno-Sio2 Glass, F. R. Laffir, A. W. Wren, Mark R. Towler 2010 Missouri University of Science and Technology

Influence Of Morphology And Processing On Xps Characterisation Of Sro-Ca-Zno-Sio2 Glass, F. R. Laffir, A. W. Wren, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

A study was conducted to demonstrate the influence of morphology and processing on X-ray photoelectron spectroscopic (XPS) characterization SrO-Ca-ZnO-SiO2 glass. The glass formulation being investigated was originally synthesized for developing a novel glass polyalkenoate cement (GPC). High resolution photoelectron spectra of Zn 2p, Ca 2p, Sr 3d, Si 2p, O 1s, and C 1s were recorded for the different forms of glass. It was observed that there was preferential enrichment of Zn2+ with an increase in the proportion of NBO for the investigated BT101 glass. The relative atomic concentration of Zn in BT101 glass was high and resulted …


Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick 2010 California Polytechnic State University, San Luis Obispo

Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick

Master's Theses

Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.

Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …


Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe 2010 California Polytechnic State University, San Luis Obispo

Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe

Master's Theses

Although highly underutilized by the medical device industry, Finite Element Analysis (FEA) in the development of new technologies is gaining popularity as regulatory bodies such as the Food and Drug Administration (FDA) begin to require additional proof of safety through scientific methods. Non-linear FEA allows engineers to realistically simulate the mechanical behavior of implants as seen in the in-vitro, or in some cases, the in-vivo configurations. The work presented in this report investigates how computational methods can be used to simulate the interaction of a St. Jude Medical silicone soft-tip as it passes through a Peel-Away Sheath (i.e. introducer). In …


Biomechanical Comparison Of Wire Circlage And Rigid Plate Fixation For Median Sternotomy Closure In Human Cadaver Specimens, Mark Steven Wong 2010 California Polytechnic State University, San Luis Obispo

Biomechanical Comparison Of Wire Circlage And Rigid Plate Fixation For Median Sternotomy Closure In Human Cadaver Specimens, Mark Steven Wong

Master's Theses

Background:

Over 700,000 patients per year undergo open-heart surgery. Healing complication rates can be up to 5% of patients who undergo this procedure, with a morbidity rate of 50% if mediastinitis supervenes. A secure and rigid fixation of surgically divided sternum is critical to avoid healing complications. The purpose of this study was to compare the yield load, construct stiffness, ultimate load, displacement at ultimate load, and post-yield behavior of three sternotomy closure methods (Peristernal wires or Sternalock titanium plates) when stressed in each of three directions: lateral distraction, rostro-caudal (longitudinal) shear distraction, and anterior-posterior (transverse) shear in a cadaveric …


Mechanical Properties Of Hydroxyapatite-Zirconia Compacts Sintered By Two Different Sintering Methods, Declan J. Curran, Thomas J. Fleming, Mark R. Towler, Stuart Hampshire 2010 Missouri University of Science and Technology

Mechanical Properties Of Hydroxyapatite-Zirconia Compacts Sintered By Two Different Sintering Methods, Declan J. Curran, Thomas J. Fleming, Mark R. Towler, Stuart Hampshire

Chemical and Biochemical Engineering Faculty Research & Creative Works

Microwave sintering is traditionally employed to reduce the sintering temperature required to densify powder compacts. The effect of microwave heating on hydroxyapatite (HA)-zirconia (ZrO2) green bodies has been investigated in order to understand how microwave energy may affect the physical and mechanical properties of the resultant densified composites. Laboratory synthesised nano-sized HA and a commercial nano-sized ZrO2 powder have been ball milled to create mixtures containing 0-5 wt% ZrO2 loadings. Compacts were microwave sintered at either 700, 1000 or 1200°C with a 1 h hold time. Comparative firings were also performed in a resistive element furnace …


Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi 2010 Old Dominion University

Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi

Electrical & Computer Engineering Theses & Dissertations

This thesis presents a three-step method to predict prostate cancer (PCa) regions on biopsy tissue samples based on high confident, low resolution PCa regions marked by a pathologist. First, a prediction model is designed to predict PCa regions using matrix-assisted laser desorption mass spectrometry (MALDI-MS) tissue imaging data from one prostate tissue slice. Second, a texture analysis technique is applied to a high magnification optical image for the same purpose from an adjacent tissue slice. Finally, those two results are fused to obtain the PCa regions that will assist MALDI imaging biomarker analysis. Experiments show that the texture analysis based …


Merlin.Net Automation Of External Reports Verification Process, Gabriel John Wettlaufer 2010 California Polytechnic State University, San Luis Obispo

Merlin.Net Automation Of External Reports Verification Process, Gabriel John Wettlaufer

Master's Theses

Merlin.net Patient Care Network is a St. Jude Medical product that is used for remote patient management. The basic concept of Merlin.net is to allow the physician to view patient device follow-up information as well as general patient and device information on a web application. The Merlin.net system also interfaces with the patient and will send them notification if they miss a follow-up. All device information will be collected automatically while the patient is sleeping. This information is sent through a telephone line to a Merlin.net server to process a report package and display the collected information on the Merlin.net …


Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam 2010 Purdue University - Main Campus

Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam

Birck and NCN Publications

Modern label-free biosensors are generally far more sensitive and require orders of magnitude less incubation time compared to their classical counterparts. However, a more important characteristic regarding the viability of this technology for applications in Genomics/Proteomics is defined by the ‘Selectivity’, i.e., the ability to concurrently and uniquely detect multiple target biomolecules in the presence of interfering species. Currently, there is no theory of Selectivity that allows optimization of competing factors and there are few experiments to probe this problem systematically. In this article, we use the elementary considerations of surface exclusion, diffusion limited transport, and void distribution function to …


Evaluation Of Two Novel Aluminum-Free, Zinc-Based Glass Polyalkenoate Cements As Alternatives To Pmma Bone Cement For Use In Vertebroplasty And Balloon Kyphoplasty, Gladius Lewis, Mark R. Towler, Daniel Boyd, Matthew J. German, Anthony W. Wren, Owen M. Clarkin, Andrew Yates 2010 Missouri University of Science and Technology

Evaluation Of Two Novel Aluminum-Free, Zinc-Based Glass Polyalkenoate Cements As Alternatives To Pmma Bone Cement For Use In Vertebroplasty And Balloon Kyphoplasty, Gladius Lewis, Mark R. Towler, Daniel Boyd, Matthew J. German, Anthony W. Wren, Owen M. Clarkin, Andrew Yates

Chemical and Biochemical Engineering Faculty Research & Creative Works

Vertebroplasty (VP) and balloon kyphoplasty (BKP) are now widely used for treating patients in whom the pain due to vertebral compression fractures is severe and has proved to be refractory to conservative treatment. These procedures involve percutaneous delivery of a bolus of an injectable bone cement either directly to the fractured vertebral body, VB (VP) or to a void created in it by an inflatable bone tamp (BKP). Thus, the cement is a vital component of both procedures. In the vast majority of VPs and BKPs, a poly(methyl methacrylate) (PMMA) bone cement is used. This material has many shortcomings, notably …


Composition-Structure-Property Relationships In Multicomponent Bioactive Glasses, Sharon Murphy 2010 Medical Engineering Design and Innovation Centre, Department of Manufacturing, Biomedical and Facilities Engineering, Cork Institute of Technology, Cork, Ireland.

Composition-Structure-Property Relationships In Multicomponent Bioactive Glasses, Sharon Murphy

Theses

Silicate glasses function effectively as bone grafts by stimulating bone regeneration through gene activation. However these materials offer little therapeutic potential for the regeneration of healthy bone in those suffering from metabolic bone diseases such as osteoporosis. Examining the composition-structure-property relationships arising from the incorporation of therapeutic ions such as strontium (Sr) and zinc (Zn) into such glasses in order to allow for healthy bone regeneration and antibacterial efficacy, as well as sodium (Na) to allow for controlled ion release was the objective of this work. Eight calcium-strontium-sodium-zinc-silicate glass compositions were produced, based on incremental additions of Sr and Na. …


Digital Commons powered by bepress