Effects Of A Passive Dynamic Lower-Leg Exoskeleton During Walking,
2019
University of Nebraska at Omaha
Effects Of A Passive Dynamic Lower-Leg Exoskeleton During Walking, Blake Beier
UNO Student Research and Creative Activity Fair
The ankle joint is one of the most important joints during walking. If the muscles surrounding the ankle are weak, there are reductions in the ability to generate appropriate torques and powers at the ankle. This leads to slower self-selected walking speeds, which correlate with poor physical functioning, more disabilities, increased hospitalization visits and costs, and even mortality. Because of this, many orthotic and exoskeletal devices have been created to restore proper ankle function by promoting ankle plantar flexion. Utilizing 3D printing and an extension spring, we created an easily accessible, reproducible, and modifiable exoskeleton that has the potential to …
The Time Of Slip Onset During Stance Influences The Characteristics Of The Unconstrained Perturbation,
2019
University of Nebraska at Omaha
The Time Of Slip Onset During Stance Influences The Characteristics Of The Unconstrained Perturbation, Corbin Rasmussen, Nathaniel Hunt
UNO Student Research and Creative Activity Fair
Falls pose a significant health hazard, resulting in devastating injuries like broken wrists, fractured hips, and traumatic brain injuries that exceed $50 billion in U.S. medical costs. To address these risks, biomechanists have subjected individuals to simulated slips in order to study the factors that lead to falls. These studies have focused on slips that happen immediately after heel-strike and are unnaturally restricted by the methods used to cause the slip. Therefore, the effects of unconstrained slips that occur throughout stance phase are unknown. To address this knowledge gap, we examined the relationship between the timing of slip onset and …
Humeral Guide For Intraosseous Vascular Access,
2019
Thayer School of Engineering
Humeral Guide For Intraosseous Vascular Access, Alexa Lewis, Colin Minor, Josephine Kalshoven, Ellie Ng, Gabriela Lowry, Alana Tucker
ENGS 89/90 Reports
Intraosseous (IO) infusion is a procedure performed in emergency situations, in order to rapidly infuse fluid or medications into a patient’s vascular system via bone marrow in the humerus or tibia. Unfortunately, the current method for identifying the humeral insertion site (palpation) can be impossible in heavily muscled or obese patients, which may result in needle misplacement, the leading cause of complications. To overcome these difficulties, this project, sponsored by IOMETRY, Inc., focused on the development of an insertion site guide, which is compatible with current IO access equipment and allows rapid and accurate identification of the humeral insertion site.
Rethinking Solutions For Male Incontinence,
2019
Dartmouth College
Rethinking Solutions For Male Incontinence, Martin S. Gross, Jayanth V. Batchu, Douglas R. Beahm, Rebecca J. Conway, Aamuktha Porika, Noura Srour
ENGS 89/90 Reports
Following a radical prostatectomy, the main surgical treatment for prostate cancer, a majority of men will experience some level of urinary incontinence. When severe, this incontinence creates social isolation, leads to risk of infection from dried urine, and prevents men from participating in activities they love. The most common treatment in the US is a surgically placed AMS 800, produced by Boston Scientific. The AMS 800 surgery is highly invasive with a lengthy recovery time. Also, the device requires manual activation using a pump in the scrotum and erodes the urethra over time by constant compression.
Our group’s design is …
Heat Stress Identification,
2019
California Polytechnic State University, San Luis Obispo
Heat Stress Identification, Nathanial Nyberg, Christina Santini, Zachary Miller
Biomedical Engineering
This document contains all information pertinent to the creation of the desired product and how the desired product fulfills the problem statement. This document clearly defines the customer requirements and how they relate to engineering specifications, metrics that will define the boundaries that the desired product must lie within. This document will then reveal all concepts that were considered during the design phase of this project and how those concepts were compared. This includes all quantitative parameters that provided a clear front-runner concept and the rationale for those parameters and the values and weight assigned to them.
Then this document …
Automated Microscope Stage,
2019
California Polytechnic State University, San Luis Obispo
Automated Microscope Stage, Corin Nishimoto, Alison Flesch, Theo Anastos
Biomedical Engineering
This document seeks to describe the background information, customer requirements, design specifications, indications for use, selected materials, proposed budget, prototypes, final design, manufacturing processes, and testing methods regarding the CellOptimizer automated microscope stage product.
Esophageal Mapping And Temperature Regulation For Catheter Ablation,
2019
California Polytechnic State University, San Luis Obispo
Esophageal Mapping And Temperature Regulation For Catheter Ablation, Madison J. Keith, Morgan A. Jawitz, Sarah L. Sanders
Biomedical Engineering
The purpose of this document is to provide a development summary for a proposed esophageal temperature mapping device used during catheter ablation. Catheter ablation therapy is performed in the left atria with hot or cold materials to create scar tissue to treat atrial fibrillation. However, utilized temperatures and absorbed energies from the catheter can cause undesired esophageal damage. Therefore, this medical device is designed to monitor esophageal temperature and map its location during catheter ablation. If dangerous temperatures are reached, the device will alarm the surgeon.
This document provides an in-depth overview of the esophageal temperaturemapping device’s development and contains …
Slit Lamp Ophthalmoscope Redesign,
2019
California Polytechnic State University, San Luis Obispo
Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer
Biomedical Engineering
The slit lamp ophthalmoscope is used by ophthalmologists for diagnosis of pathologies in the eye. The device is used for identifying ocular diseases or indications of other possible systemic diseases to treat them before the diseases progress. Redesign of the ergonomics and adjustment mechanisms of the slit lamp ophthalmoscope will attempt to improve the compatibility of the device across a greater variety of patients. The wider headrest tower of 12.75 inches, the wider table cutout of 12 inches, and the 12 inches of extension of the headrest tower creates a better ergonomic fit for the patient and doctor. The wider …
Fluid Delivery System For A Cell Culture On A Microfluidic Chip,
2019
California Polytechnic State University, San Luis Obispo
Fluid Delivery System For A Cell Culture On A Microfluidic Chip, Austin J. Roeder, Colleen A. Richards, Emily A. Matteson
Biomedical Engineering
This project report provides a description of the progress made in the development of a fluid delivery system for a microfluidic cell culture on a chip. The system is intended to be used in a humidified incubator in a university laboratory and the fluid delivery system is required to exist and operate within that incubator for extended periods of time. Therefore, the system will be gravity-driven and contain no electronic components. The key specification of the system is to provide fluid flow at a constant velocity.
After manufacturing and testing the device, all specifications were met except for the fluid …
Pressure Cylinder Controlled Release Valve,
2019
California Polytechnic State University, San Luis Obispo
Pressure Cylinder Controlled Release Valve, Alexa Dominique Balbuena
Biomedical Engineering
This project aims to integrate an automatic gas release system in a pre-existing scaffold fabrication process for tissue engineering applications.
To form the proper scaffold structure, the fabrication process is heavily influenced by the change in its surrounding pressure. The current production involves a pressure transducer and electric valve that is managed manually to create a suitable pressure environment for the scaffold. This method, although functional, proves to be ineffective when creating several batches; the user needs to constantly monitor the developing pressure profile and alter voltage parameters accordingly to create a linear gas release under a predetermined slope.
To …
Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications,
2019
California Polytechnic State University, San Luis Obispo
Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler
Master's Theses
Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …
The Effect Of Calcination Rate On The Structure Of Mesoporous Bioactive Glasses,
2019
Missouri University of Science and Technology
The Effect Of Calcination Rate On The Structure Of Mesoporous Bioactive Glasses, Saidur Rahman, Andrew Mendonca, Adel Alhalawani, Deanna Polintan, Owen M. Clarkin, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Mesoporous bioactive glasses (MBGs) are designed to have high specific surface area. They are formulated by a sol–gel process to formulate the glass followed by calcination. This study evaluates how calcination heating rate influences the porous architecture, and thereby the specific surface area, of MBGs. MBGs of molar ratio 80:15:5 for SiO2 :CaO:P2 O 5 were calcined using both low (1 °C/min) and high (20 °C/min) heating rates, termed as L-MBG and H-MBG, respectively. The results obtained from small-angle X-ray diffraction (SAXRD) confirm that the MBGs possess 2D hexagonal (P6mm) spacing groups and wide-angle XRD confirms the amorphicity …
Raman Spectroscopy As A Predictive Tool For Monitoring Osteoporosis Therapy In A Rat Model Of Postmenopausal Osteoporosis,
2019
Missouri University of Science and Technology
Raman Spectroscopy As A Predictive Tool For Monitoring Osteoporosis Therapy In A Rat Model Of Postmenopausal Osteoporosis, J. Renwick Beattie, Antonia Sophocleous, M. Clare Caraher, Olive O'Driscoll, Niamh M. Cummins, Steven E.J. Bell, Mark R. Towler, Alireza Rahimnejad Yazdi, Stuart H. Ralston, Aymen I. Idris
Chemical and Biochemical Engineering Faculty Research & Creative Works
Pharmacological therapy of osteoporosis reduces bone loss and risk of fracture in patients. Modulation of bone mineral density cannot explain all effects. Other aspects of bone quality affecting fragility and ways to monitor them need to be better understood. Keratinous tissue acts as surrogate marker for bone protein deterioration caused by oestrogen deficiency in rats. Ovariectomised rats were treated with alendronate (ALN), parathyroid hormone (PTH) or estrogen (E2). MicroCT assessed macro structural changes. Raman spectroscopy assessed biochemical changes. Micro CT confirmed that all treatments prevented ovariectomy-induced macro structural bone loss in rats. PTH induced macro structural changes unrelated to ovariectomy. …
Communication Of Deaf People Based On Myoware Muscle Sensor,
2019
Wayne State University
Communication Of Deaf People Based On Myoware Muscle Sensor, Mohamad Ataya
Research Opportunities for Engineering Undergraduates (ROEU) Program 2018-19
The current project aims to create a product that enhances communication of deaf people. The developed product has the following features:
• a muscle sensor that transcribes sign language into actual letters
• a voice detector that translates speech into actual words
• the ability to receive and send emergency alerts.
The Impact Of Extreme Virtual Elevation Above Grade On Construction Workers' Physiological Responses, Physical Responses, And Task Performance,
2019
University of Nebraska-Lincoln
The Impact Of Extreme Virtual Elevation Above Grade On Construction Workers' Physiological Responses, Physical Responses, And Task Performance, Mahmoud Habibnezhad
Department of Construction Engineering and Management: Dissertations, Theses, and Student Research
On average, in every two work hours, one person dies from work-related injuries at construction sites. Most incidents are due to falling from elevated surfaces. Slips, trips, and loss of balance are the main causes. Studies suggest that instigating visual mismatch and physiological changes are among the most important reasons behind falling from narrow elevated surfaces. By using advanced virtual reality models, this dissertation aims to highlight some of the possible effects of a destabilizing environment (i.e., elevation above grade) on workers’ physiological responses and task performance. More specifically, this dissertation strives to find potential effects of elevation above grade …
Development Of An Eye Movement Based Predictive Model For Discrimination Of Parkinson's Disease From Other Parkinsonisms And Controls,
2019
Virginia Commonwealth University
Development Of An Eye Movement Based Predictive Model For Discrimination Of Parkinson's Disease From Other Parkinsonisms And Controls, Mary Anisa Kannan
Theses and Dissertations
Purpose: Due to the neurological aspects of Parkinson’s Disease (PD) and the sensitivity of eye movements to neurological issues, eye tracking has the potential to be an objective biomarker with higher accuracy in diagnosis than current clinical standards. Currently when PD is diagnosed clinically, there is an accuracy of 74% when diagnosed by a general practitioner and 82% when diagnosed by a movement disorder specialist. This study was designed to: 1. Assess eye movements as a potential biomarker for Parkinson’s Disease. 2. Determine if eye movements can distinguish between Parkinson’s Disease and commonly confounded movement disorders with parkinsonian symptoms. 3. …
A Smart Implantable Bone Fixation Plate Providing Actuation And Load Monitoring For Orthopedic Fracture Healing,
2019
Michigan Technological University
A Smart Implantable Bone Fixation Plate Providing Actuation And Load Monitoring For Orthopedic Fracture Healing, Brad Nelson
Dissertations, Master's Theses and Master's Reports
Fracture non-union occurs in roughly 5-10% of all fracture cases, and current interventions are both time-consuming and costly. There is therefore significant incentive to develop new tools to improve fracture healing outcomes. Several studies have shown that low-magnitude, high-frequency (LMHF) mechanical loading can promote faster healing and reduce the risk of refracture in critical-size long bone fractures. This is typically done using whole-body vibration, which may result in undesirable systemic effects on the rest of the body. This work discusses an implantable piezoelectric fixation plate that can both apply LMHF loading directly to the fracture site using flexible scheduling and …
Well-Ordered Mesoporous Silica And Bioactive Glasses: Promise For Improved Hemostasis,
2019
Missouri University of Science and Technology
Well-Ordered Mesoporous Silica And Bioactive Glasses: Promise For Improved Hemostasis, Sara Pourshahrestani, Nahrizul Adib Kadri, Ehsan Zeimaran, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Immediate control of uncontrolled bleeding and infection are essential for saving lives in both combat and civilian arenas. Inorganic well-ordered mesoporous silica and bioactive glasses have recently shown great promise for accelerating hemostasis and infection control. However, to date, there has been no comprehensive report assessing their specific mechanism of action in accelerating the hemostasis process and exerting an antibacterial effect. After providing a brief overview of the hemostasis process, this review presents a critical overview of the recently developed inorganic mesoporous silica and bioactive glass-based materials proposed for hemostatic clinical applications and specifically investigates their unique characteristics that render …
Relaxed Mental State Detection Using The Emotiv Epoc And Adaptive Threshold Algorithms,
2019
Eastern Washington University
Relaxed Mental State Detection Using The Emotiv Epoc And Adaptive Threshold Algorithms, Olin L. Anderson
EWU Masters Thesis Collection
The electroencephalogram (EEG) has proven to be useful in a wide variety of applications, including: diagnosis of mental disorders, psychological research, neurofeedback, and brain-computer interfacing. Most such applications of the EEG benefit from an ability to automatically detect when the subject is in a relaxed state. Recently, inexpensive and relatively easy to use EEG systems, with multiple electrodes, have become available at prices comparable to cellular phones or game machines. This project’s purpose is to investigate the feasibility of real-time classification of a subject's relaxation state using one such consumer-grade EEG system, the Emotiv Epoc. The subject's state is classified …
A Brain-Computer Interface For Closed-Loop Sensory Stimulation During Motor Training In Patients With Tetraplegia,
2019
University of Kentucky
A Brain-Computer Interface For Closed-Loop Sensory Stimulation During Motor Training In Patients With Tetraplegia, Sarah Helen Thomas
Theses and Dissertations--Biomedical Engineering
Normal movement execution requires proper coupling of motor and sensory activation. An increasing body of literature supports the idea that incorporation of sensory stimulation into motor rehabilitation practices increases its effectiveness. Paired associative stimulation (PAS) studies, in which afferent and efferent pathways are activated in tandem, have brought attention to the importance of well-timed stimulation rather than non-associative (i.e., open-loop) activation. In patients with tetraplegia resulting from spinal cord injury (SCI), varying degrees of upper limb function may remain and could be harnessed for rehabilitation. Incorporating associative sensory stimulation coupled with self-paced motor training would be a means for supplementing …
