Time Dependent Fixation And Implantation Forces For A Femoral Knee Component: An In Vitro Study,
2010
University of Wisconsin-Madison
Time Dependent Fixation And Implantation Forces For A Femoral Knee Component: An In Vitro Study, Travis A. Burgers, Jim Mason, Matthew Squire, Heidi-Lynn Ploeg
Mechanical Engineering Faculty Publications
Implant survival rate is a primary concern for individuals receiving a primary total knee arthroplasty. Loosening is the primary reason for revision surgery and was therefore the focus of the current study. To better understand the mechanics of implant fixation, the time-dependent fixation of a femoral knee component was measured in vitro on three cadaveric femurs. The fixation of each femoral knee component was measured with strain gauged implants for at least 10 minutes on each femoral component. Additionally, impaction forces were measured during the implantation of each component. These forces were 2–6 times less than previously reported. The implantation …
Development Of A Physical Windkessel Module To Re-Create In Vivo Vascular Flow Impedance For In Vitro Experiments,
2010
Stanford University
Development Of A Physical Windkessel Module To Re-Create In Vivo Vascular Flow Impedance For In Vitro Experiments, Ethan Kung, Charles A. Taylor
Publications
To create and characterize a physical Windkessel module that can provide realistic and predictable vascular impedances for in vitro flow experiments used for computational fluid dynamics validation, and other investigations of the cardiovascular system and medical devices. We developed practical design and manufacturing methods for constructing flow resistance and capacitance units. Using these units we assembled a Windkessel impedance module and defined its corresponding analytical model incorporating an inductance to account for fluid momentum. We tested various resistance units and Windkessel modules using a flow system, and compared experimental measurements to analytical predictions of pressure, flow, and impedance. The resistance …
Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units,
2010
Case Western Reserve University
Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo
Mechanical Engineering Faculty Publications
In this paper, a personal micronavigation system that uses high-resolution gait-corrected inertial measurement units is presented. The goal of this paper is to develop a navigation system that uses secondary inertial variables, such as velocity, to enable long-term precise navigation in the absence of Global Positioning System (GPS) and beacon signals. In this scheme, measured zerovelocity duration from the ground reaction sensors is used to reset the accumulated integration errors from accelerometers and gyroscopes in position calculation. With the described system, an average position error of 4 m is achieved at the end of half-hour walks.
Production Of Anatomical Models From Ct Scan Data,
2010
Technological University Dublin
Production Of Anatomical Models From Ct Scan Data, John Brennan
Other resources
Rapid Prototyping (RP) technology was conceived in the mid 1980s as a method of manufacturing models, particularly to support the design of new motor vehicles. However as early as 1995 the potential to take data from medical scanners and generate models of patient anatomy to assist clinicians plan complex surgical procedures had been recognised, albeit by researchers rather than the mainstream medical industry. Over the last 15 years the production of preoperative planning models has increased dramatically and moreover, the potential to produce customised implants recognised.
Although RP technology is now established in the medical field work is still on …
Distribution Of Capillary Transit Times In Isolated Lungs Of Oxygen-Tolerant Rats,
2010
Marquette University
Distribution Of Capillary Transit Times In Isolated Lungs Of Oxygen-Tolerant Rats, Madhavi Ramakrishna, Zhuohui Gan, Anne V. Clough, Robert C. Molthen, David L. Roerig, Said H. Audi
Biomedical Engineering Faculty Research and Publications
Rats pre-exposed to 85% O2 for 5–7 days tolerate the otherwise lethal effects of 100% O2. The objective was to evaluate the effect of rat exposure to 85% O2 for 7 days on lung capillary mean transit time (t¯c) and distribution of capillary transit times (h c(t)). This information is important for subsequent evaluation of the effect of this hyperoxia model on the redox metabolic functions of the pulmonary capillary endothelium. The venous concentration vs. time outflow curves of fluorescein isothiocyanate labeled dextran (FITC-dex), an intravascular indicator, and coenzyme Q1 hydroquinone …
Removal Of Low Density Sediments By Vegetative Filters,
2010
University of Nebraska-Lincoln
Removal Of Low Density Sediments By Vegetative Filters, Brent M. Hall
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
The use of vegetative filter strips (VFS) is a longstanding best management practice for the removal of sediment and other pollutants from overland flow. Many attempts have been made to model the effectiveness of a VFS based upon soil, vegetation, and sediment properties, and also upon flow conditions, but little work has been done to investigate the reliability of the existing models when considering sediments, such as microbial pathogens, that have a lower density than the mineral sediments used for development of the models. The objectives of this study were to: 1) quantify the ability of a VFS to remove …
Can Spr Be Used To Interrogate The Double Layer Of Nacl,
2010
California Polytechnic State University, San Luis Obispo
Can Spr Be Used To Interrogate The Double Layer Of Nacl, Brandon Kawula
Biomedical Engineering
Solutions of reagent grade salt .1, .01, .001, .0001, .00001M were run through a SPR to see if SPR had enough resolution to detect the formation of the electric double layer. We found that NaCl did in fact return a detectable signal. The signal shape seems to depend on concentration. While more study may need to be done to get definite information it looks like SPR can interrogate the double layer.
Plasma Mediated Molecular Delivery,
2010
University of South Florida
Plasma Mediated Molecular Delivery, Richard J. Connolly
USF Tampa Graduate Theses and Dissertations
Non-viral delivery of plasmid DNA has traditionally relied upon physical forces applied directly to target tissues. These physical methods typically involve contact between an applicator and the target tissue and often cause transient patient discomfort. To overcome the contact-dependent limitations of such delivery methodologies, an atmospheric direct current plasma source was developed to deposit ionized gas molecules onto localized treatment sites. The deposition of charged species onto a treatment site can lead to the establishment of an electric field with strengths similar to those used for traditional electroporation. In vitro experiments proved that this technology could transiently permeabilize cell membranes …
Individual Muscle Contributions To The Axial Knee Joint Contact Force During Normal Walking,
2010
Boise State University
Individual Muscle Contributions To The Axial Knee Joint Contact Force During Normal Walking, Kotaro Sasaki, Richard R. Neptune
Mechanical and Biomedical Engineering Faculty Publications and Presentations
Muscles are significant contributors to the high joint forces developed in the knee during human walking. Not only do muscles contribute to the knee joint forces by acting to compress the joint, but they also develop joint forces indirectly through their contributions to the ground reaction forces via dynamic coupling. Thus, muscles can have significant contributions to forces at joints they do not span. However, few studies have investigated how the major lower-limb muscles contribute to the knee joint contact forces during walking. The goal of this study was to use a muscle-actuated forward dynamics simulation of walking to identify …
Deletion Of The Cel48s Cellulase From Clostridium Thermocellum,
2010
Dartmouth College
Deletion Of The Cel48s Cellulase From Clostridium Thermocellum, Daniel G. Olson, Shital A. Tripathi, Richard J. Giannone, Jonathan Lo, Nicky C. Caiazza, David A. Hogsett, Robert L. Hettich, Adam M. Guss, Genia Dubrovsky, Lee R. Lynd
Dartmouth Scholarship
Clostridium thermocellum is a thermophilic anaerobic bacterium that rapidly solubilizes cellulose with the aid of a multienzyme cellulosome complex. Creation of knockout mutants for Cel48S (also known as CelS, S(S), and S8), the most abundant cellulosome subunit, was undertaken to gain insight into its role in enzymatic and microbial cellulose solubilization. Cultures of the Cel48S deletion mutant (S mutant) were able to completely solubilize 10 g/L crystalline cellulose. The cellulose hydrolysis rate of the S mutant strain was 60% lower than the parent strain, with the S mutant strain also exhibiting a 40% reduction in cell yield. The cellulosome produced …
The Virtual Hip: An Anatomically Accurate Finite Element Model Based On The Visible Human Dataset,
2010
University of South Florida
The Virtual Hip: An Anatomically Accurate Finite Element Model Based On The Visible Human Dataset, Jonathan M. Ford
USF Tampa Graduate Theses and Dissertations
The purpose of this study is to determine if element decimation of a 3-D anatomical model affects the results of Finite Element Analysis (FEA). FEA has been increasingly applied to the biological and medical sciences. In order for an anatomical model to successfully run in FEA, the 3-D model’s complex geometry must be simplified, resulting in a loss of anatomical detail. The process of decimation reduces the number of elements within the structure and creates a simpler approximation of the model. Using the National Library of Medicine’s Visible Human Male dataset, a virtual 3-D representation of several structures of the …
Surface Morphology Of Platelet Adhesion Influenced By Activators, Inhibitors And Shear Stress,
2010
Louisiana Tech University
Surface Morphology Of Platelet Adhesion Influenced By Activators, Inhibitors And Shear Stress, Melanie Groan Watson
Doctoral Dissertations
Platelet activation involves multiple events, one of which is the generation and release of nitric oxide (NO), a platelet aggregation inhibitor. Platelets simultaneously send and receive various agents that promote a positive and negative feedback control system during hemostasis. Although the purpose of platelet-derived NO is not fully understood, NO is known to inhibit platelet recruitment. NO's relatively large diffusion coefficient allows it to diffuse more rapidly than platelet agonists. It may thus be able to inhibit recruitment of platelets near the periphery of a growing thrombus before agonists have substantially accumulated in those regions.
Results from two studies in …
Selective Biochlorination Of Hydroxyquinolines By A Flavin-Dependent Halogenase,
2010
Utah State University
Selective Biochlorination Of Hydroxyquinolines By A Flavin-Dependent Halogenase, Fuchao Xu, Amanda Merkley, Dayu Yu, Jixun Zhan
Biological Engineering Faculty Publications
Rdc2 is a flavin-dependent halogenase from Pochonia chlamydosporia. Through the introduction of a His6-tag to both the N- and C-termini, the isolation yield of Rdc2 from Escherichia coli using Ni-NTA affinity chromatography was increased by three-fold. In vitro reaction of Rdc2 and a flavin reductase (Fre) with seven different hydroxyquinolines revealed that 3-hydroxyquinoline (3), 5-hydroxyquinoline (5), 6-hydroxyquinoline (6), and 7-hydroxyquinoline (7) can be specifically halogenated. These products were prepared by incubating the corresponding substrates with IPTG-induced E. coli BL21(DE3)/Rdc2. They were respectively characterized as 3-hydroxy-4-chloroquinoline (3a), 5-hydroxy-6-chloroquinoline (5a), 5-chloro-6-hydroxyquinoline (6a), and 7-hydroxy-8-chloroquinoline (7a) by NMR and MS …
Detrimental Thoracoabdominal Interaction With Lateral Airbag Restraints,
2010
Marquette University
Detrimental Thoracoabdominal Interaction With Lateral Airbag Restraints, Jason John Hallman
Dissertations (1934 -)
Side impact motor vehicle crashes pose unique challenges for occupant protection, particularly with regard to torso injury mitigation. The minimal crush distance between the vehicle exterior and the occupant torso has necessitated advanced passive safety technologies in response to tightened regulatory requirements and increased public awareness of safety issues. In particular, lateral airbag restraints (side airbags) have undergone a rapid and unregulated introduction in recent years, with US availability increasing to over 90% of new vehicles in 2010. As with frontal airbag restraints, the prdissertationsity for injury to occupants in close proximity to side airbag deployment remains a concern. Test …
An Analytical Model For Rotator Cuff Repairs,
2010
Cleveland Clinic
An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, A.J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin
Chemical & Biomedical Engineering Faculty Publications
Background: Currently, natural and synthetic scaffolds are being explored as augmentation devices for rotator cuff repair. When used in this manner, these devices are believed to offer some degree of load sharing; however, no studies have quantified this effect. Furthermore, the manner in which loads on an augmented rotator cuff repair are distributed among the various components of the repair is not known, nor is the relative biomechanical importance of each component. The objectives of this study are to (1) develop quasi-static analytical models of simplified rotator cuff repairs, (2) validate the models, and (3) predict the degree of …
Classification Of Emg Signals To Control A Prosthetic Hand Using Time-Frequesncy Representations And Support Vector Machines,
2010
Louisiana Tech University
Classification Of Emg Signals To Control A Prosthetic Hand Using Time-Frequesncy Representations And Support Vector Machines, Juan Manuel Fontana
Doctoral Dissertations
Myoelectric signals (MES) are viable control signals for externally-powered prosthetic devices. They may improve both the functionality and the cosmetic appearance of these devices. Conventional controllers, based on the signal's amplitude features in the control strategy, lack a large number of controllable states because signals from independent muscles are required for each degree of freedom (DoF) of the device. Myoelectric pattern recognition systems can overcome this problem by discriminating different residual muscle movements instead of contraction levels of individual muscles. However, the lack of long-term robustness in these systems and the design of counter-intuitive control/command interfaces have resulted in low …
Nonlinear Control Strategy For A Cost Effective Myoelectric Prosthetic Hand,
2010
Louisiana Tech University
Nonlinear Control Strategy For A Cost Effective Myoelectric Prosthetic Hand, Cristian Federico Pasluosta
Doctoral Dissertations
The loss of a limb tremendously impacts the life of the affected individual. In the past decades, researchers have been developing artificial limbs that may return some of the missing functions and cosmetics. However, the development of dexterous mechanisms capable of mimicking the function of the human hand is a complex venture. Even though myoelectric prostheses have advanced, several issues remain to be solved before an artificial limb may be comparable to its human counterpart. Moreover, the high cost of advanced limbs prevents their widespread use among the low-income population.
This dissertation presents a strategy for the low-level of control …
The Effect Of Ionic Dissolution Products Of Ca-Sr-Na-Zn-Si Bioactive Glass On In Vitro Cytocompatibility,
2010
Missouri University of Science and Technology
The Effect Of Ionic Dissolution Products Of Ca-Sr-Na-Zn-Si Bioactive Glass On In Vitro Cytocompatibility, S. Murphy, A. W. Wren, Mark R. Towler, D. Boyd
Chemical and Biochemical Engineering Faculty Research & Creative Works
Many commercial bone grafts cannot regenerate healthy bone in place of diseased bone. Bioactive glasses have received much attention in this regard due to the ability of their ionic dissolution products to promote cell proliferation, cell differentiation and activate gene expression. Through the incorporation of certain ions, bioactive glasses can become therapeutic for specific pathological situations. Calcium-strontium-sodium-zinc-silicate glass bone grafts have been shown to release therapeutic levels of zinc and strontium, however the in vitro compatibility of these materials is yet to be reported. In this study, the in vitro cytocompatibility of three different calcium-strontium-sodium-zinc-silicate glasses was examined as a …
Comparison Of Antibacterial Properties Of Commercial Bone Cements And Fillers With A Zinc-Based Glass Polyalkenoate Cement,
2010
Missouri University of Science and Technology
Comparison Of Antibacterial Properties Of Commercial Bone Cements And Fillers With A Zinc-Based Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Postoperative infection following invasive surgical procedures is a significant cause for concern, particularly in spinal reconstructive surgery. The objective of this study is to compare the antibacterial efficacy of a novel zinc-based glass polyalkenoate cement (Zn-GPC) based on 0.04SrO-0.12CaO-0.36ZnO- 0.48SiO2 glass, to a number of commercially available bone cements and fillers including Simplex P + Tobramycin (STob), Spineplex (Spine) and Novabone Putty (NPut). The agar diffusion test was performed on each material against Escherichia coli, Staphlococcus epidermidis, Pseudomonas aeruginosa and Staphlococcus Aureus. STob was found to produce large inhibition zones in each …
Ankle Strength And Functional Limitations In Children And Adolescents With Type I Osteogenesis Imperfecta,
2010
Medical College of Wisconsin
Ankle Strength And Functional Limitations In Children And Adolescents With Type I Osteogenesis Imperfecta, Angela Caudill, Ann Flanagan, Sahar Hassani, Adam Graf, Ruta Bajorunaite, Gerald F. Harris, Peter A. Smith
Biomedical Engineering Faculty Research and Publications
Purpose: To determine whether children with type I osteogenesis imperfecta (OI) exhibit ankle plantar flexor weakness and whether this correlates with physical function.
Methods: Twenty children and adolescents with type I OI and 20 age-matched controls (age 6-18 years) participated in a single evaluation session. Data included strength assessment, Gillette Functional Assessment Questionnaire, Pediatric Outcome Data Collection Instrument (PODCI), and Faces Pain Scale—Revised.
Results: Ankle plantar flexor weakness was evident in the OI group compared with the control group. Heel-rise strength correlated with ankle isometric plantar flexion strength. Limitations in PODCI subscales—sports and physical function and pain/comfort—are present in the …