Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

11,440 Full-Text Articles 22,480 Authors 5,680,319 Downloads 211 Institutions

All Articles in Biomedical Engineering and Bioengineering

Faceted Search

11,440 full-text articles. Page 412 of 470.

Piezoelectric Probes And Their Capacity To Monitor Time Varying Viscosity, Eman Ahmed 2012 Virginia Commonwealth University

Piezoelectric Probes And Their Capacity To Monitor Time Varying Viscosity, Eman Ahmed

Theses and Dissertations

Real-time, bedside observation of patient clotting is essential in various surgeries in the operating room (OR), but specifically during cardiac surgeries. The objective of this thesis is to design and test a new piezoelectric device that can be used for viscoelasticity measurement with time as a Point of Care (POC) test. Slow turnaround times (TAT) of current methods to monitor blood viscoelastic changes in patients have led to excessive bleeding and the need for blood transfusions in many situations (Despotis et al, 1997). This study shows that the phase shift produced by a resonator sensor can be related to the …


A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen 2012 Dartmouth College

A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen

Dartmouth Scholarship

A Near Infrared Spectral Tomography (NIRST) system has been developed and integrated into a commercial Digital Breast Tomosynthesis (DBT) scanner to allow structural and functional imaging of breast in vivo. The NIRST instrument uses an 8-wavelength continuous wave (CW) laser-based scanning source assembly and a 75-element silicon photodiode solid-state detector panel to produce dense spectral and spatial projection data from which spectrally constrained 3D tomographic images of tissue chromophores are produced. Integration of the optical imaging system into the DBT scanner allows direct co-registration of the optical and DBT images, while also facilitating the synergistic use of x-ray contrast as …


Integrated Fiber Electrospinning: Creating Spatially Complex Electrospun Scaffolds With Minimal Delamination, Casey Grey 2012 Virginia Commonwealth University

Integrated Fiber Electrospinning: Creating Spatially Complex Electrospun Scaffolds With Minimal Delamination, Casey Grey

Theses and Dissertations

Tissue engineering scaffolds come in many shapes and sizes, however, due to difficulty manufacturing the microstructure architecture required in tissue engineering, most scaffolds are architecturally non-dynamic in nature. Because the microstructural architecture of all biological tissues is inherently complicated, non-dynamic tissue engineering scaffolds tend to be a poor platform for tissue regeneration. The current method for manufacturing dynamic tissue engineering scaffolds involves electrospinning successive layers of different fibers, an approach that exhibits no fiber transition between layers and subsequent delamination problems. In this study we aim to address the design challenges of tissue engineering scaffolds through our novel integrated fiber …


Preparation And Characterization Of A Self-Crimp Side-By-Side Bicomponent Electrospun Material, Yang Han 2012 Virginia Commonwealth University

Preparation And Characterization Of A Self-Crimp Side-By-Side Bicomponent Electrospun Material, Yang Han

Theses and Dissertations

Bicomponent composite fibers have been widely used in the textile industry and are gaining increasing attention on biomedical applications. In this research, polycaprolactone/poly (lactic acid) side-by-side bicomponent fibers were created for the application of a biodegradable scaffold. The side-by-side structure endowed the fiber with self-crimps when it was processed under certain conditions. This material was produced by electrospinning and collected on a high speed rotating mandrel to get highly oriented fibers. A mechanical stretch at the same direction was done followed by a wet heat treatment for polymer retraction. Crimped fibers were demonstrated by scanning electron microscopy. The quantitative porosity …


Nitric Oxide Releasing Polymers For Vascular Graft Applications, Ifeanyi U. Onyejekwe 2012 Syracuse University

Nitric Oxide Releasing Polymers For Vascular Graft Applications, Ifeanyi U. Onyejekwe

Biomedical and Chemical Engineering - Dissertations

Nitric oxide [NO] is an endogenous gas involved in a multitude of physiological functions, ranging from vasodilatation, inflammatory response to inhibition of platelet aggregation. Significant interest exists for therapeutic application of exogenous NO, particularly for the improvement of foreign-body responses of biomaterials. One challenge amongst several others that must be taken into consideration is NO's short half-life, ranging from 2-3 s, in physiological systems. Researchers have worked on synthesizing materials, formally referred to as NO donors/NONOates capable of preserving NO and spontaneous gas release upon contact with blood under physiological conditions. Two groups of these commercially available NO donors known …


The Role Of Fluorescence And Human Factors In Quantitative Transdermal Blood And Tissue Analysis Using Nir Raman Spectroscopy, Bin Deng 2012 Syracuse University

The Role Of Fluorescence And Human Factors In Quantitative Transdermal Blood And Tissue Analysis Using Nir Raman Spectroscopy, Bin Deng

Biomedical and Chemical Engineering - Dissertations

This research is part of an ongoing project aimed at the application of combined near infrared (NIR) Raman and fluorescence spectroscopy to noninvasive in vivo blood analysis including but not limited to glucose monitoring. Coping with practicalities of human factors and exploring ways to obtain and use knowledge gained about autofluorescence to improve algorithms for blood and tissue analysis are the general goals of this research. Firstly, the study investigated the various sources of human factors pertinent to our concerns, such as fingerprints, turgor, skin hydration and pigmentation. We then introduced specialized in vivo apparatus including means for precise and …


Auto-Fluorescence Lifetime And Light Reflectance Spectroscopy For Breast Cancer Diagnosis: Potential Tools For Intraoperative Margin Detection, Vikrant Sharma, Shivaranjani Shivalingaiah, Yan Peng, David Euhus, Zygmunt Gryczynski, Hanli Liu 2012 University of Texas at Arlington

Auto-Fluorescence Lifetime And Light Reflectance Spectroscopy For Breast Cancer Diagnosis: Potential Tools For Intraoperative Margin Detection, Vikrant Sharma, Shivaranjani Shivalingaiah, Yan Peng, David Euhus, Zygmunt Gryczynski, Hanli Liu

Bioengineering Faculty Publications - Archive

This study investigates the use of two spectroscopic techniques, auto-fluorescence lifetime measurement (AFLM) and light reflectance spectroscopy (LRS), for detecting invasive ductal carcinoma (IDC) in human ex vivo breast specimens. AFLM used excitation at 447 nm with multiple emission wavelengths (532, 562, 632, and 644 nm), at which autofluorescence lifetimes and their weight factors were analyzed using a double exponent model. LRS measured reflectance spectra in the range of 500-840 nm and analyzed the spectral slopes empirically at several distinct spectral regions. Our preliminary results based on 93 measured locations (i.e., 34 IDC, 31 benign fibrous, 28 adipose) from 6 …


Effects Of Physiological Dynamic Compression Loading On Gold Nanoparticle Permeation Of Articular Cartilage, Britton McCaskill 2012 Clemson University

Effects Of Physiological Dynamic Compression Loading On Gold Nanoparticle Permeation Of Articular Cartilage, Britton Mccaskill

All Theses

Articular cartilage is essential part of the human body that aids in support and locomotion. It has unique biochemical and biomechanical properties that allow it to act as a shock absorber to disperse and distribute loading of the joints. However, it has a limited capacity to repair itself because it is not vascularized and must receive its nutrients from the surrounding synovial fluid. Articular cartilage damage can lead to many pathological conditions, including osteoarthritis. Currently, there are many surgical treatment methods that repair some of the damage if it is localized, but for widespread degradation seen in osteoarthritis, there are …


Gallium Containing Glass Polyalkenoate Anti-Cancerous Bone Cements: Glass Characterization And Physical Properties, A. W. Wren, A. Coughlan, L. Placek, Mark R. Towler 2012 Missouri University of Science and Technology

Gallium Containing Glass Polyalkenoate Anti-Cancerous Bone Cements: Glass Characterization And Physical Properties, A. W. Wren, A. Coughlan, L. Placek, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

A gallium (Ga) glass series (0.48SiO2-0.40ZnO-0.12CaO, with 0.08 mol% substitution for ZnO) was developed to formulate a Ga-containing Glass Polyalkenoate Cement (GPC) series. Network connectivity (NC) and X-ray Photoelectron Spectroscopy (XPS) was employed to investigate the role of Ga3+ in the glass, where it is assumed to act as a network modifier. Ga-GPC series was formulated with E9 and E11 polyacrylic acid (PAA) at 50, 55 and 60 wt% additions. E11 working times (Tw) ranged from 68 to 96 s (Lcon.) and 106 s for the Ga-GPCs (LGa-1 and LGa-2). Setting times (Ts) …


Experimental Composite Guidance Conduits For Peripheral Nerve Repair: An Evaluation Of Ion Release, X. F. Zhang, A. Coughlan, H. O'Shea, Mark R. Towler, S. Kehoe, D. Boyd 2012 Missouri University of Science and technology

Experimental Composite Guidance Conduits For Peripheral Nerve Repair: An Evaluation Of Ion Release, X. F. Zhang, A. Coughlan, H. O'Shea, Mark R. Towler, S. Kehoe, D. Boyd

Chemical and Biochemical Engineering Faculty Research & Creative Works

Poly (lactide-co-glycolide) (PLGA) - Pluronic F127 - glass composites have demonstrated excellent potential, from the perspective of controlled mechanical properties and cytocompatibility, for peripheral nerve regeneration. In addition to controlling the mechanical properties and cytotoxicity for such composite devices, the glass component may mediate specific responses upon implantation via degradation in the physiological environment and release of constituent elements. However, research focused on quantifying the release levels of such therapeutic ions from these experimental medical devices has been limited. To redress the balance, this paper explores the ion release profiles for Si4+, Ca2+, Na+, …


A Novel Haptic Simulator For Evaluating And Training Salient Force-Based Skills For Laparoscopic Surgery, Ravikiran Singapogu 2012 Clemson University

A Novel Haptic Simulator For Evaluating And Training Salient Force-Based Skills For Laparoscopic Surgery, Ravikiran Singapogu

All Dissertations

Laparoscopic surgery has evolved from an 'alternative' surgical technique to currently being considered as a mainstream surgical technique. However, learning this complex technique holds unique challenges to novice surgeons due to their 'distance' from the surgical site. One of the main challenges in acquiring laparoscopic skills is the acquisition of force-based or haptic skills. The neglect of popular training methods (e.g., the Fundamentals of Laparoscopic Surgery, i.e. FLS, curriculum) in addressing this aspect of skills training has led many medical skills professionals to research new, efficient methods for haptic skills training.
The overarching goal of this research was to demonstrate …


Ultrastable Synergistic Tetravalent Rna Nanoparticles For Targeting To Cancers, Farzin Haque, Dan Shu, Yi Shu, Luda S. Shlyakhtenko, Piotr G. Rychahou, B. Mark Evers, Peixuan Guo 2012 University of Kentucky

Ultrastable Synergistic Tetravalent Rna Nanoparticles For Targeting To Cancers, Farzin Haque, Dan Shu, Yi Shu, Luda S. Shlyakhtenko, Piotr G. Rychahou, B. Mark Evers, Peixuan Guo

Pharmaceutical Sciences Faculty Publications

One of the advantages of nanotechnology is the feasibility to construct therapeutic particles carrying multiple therapeutics with defined structure and stoichiometry. The field of RNA nanotechnology is emerging. However, controlled assembly of stable RNA nanoparticles with multiple functionalities which retain their original role is challenging due to refolding after fusion. Herein, we report the construction of thermodynamically stable X-shaped RNA nanoparticles to carry four therapeutic RNA motifs by self-assembly of reengineered small RNA fragments. We proved that each arm of the four helices in the X-motif can harbor one siRNA, ribozyme, or aptamer without affecting the folding of the central …


The Biomechanical Role Of Scaffolds In Augmented Rotator Cuff Tendon Repairs, Amit Aurora, Jesse A. McCarron, Antonie J. van den Bogert, Jorge E. Gatica, Joseph P. Iannotti, Kathleen A. Derwin 2012 Cleveland Clinic

The Biomechanical Role Of Scaffolds In Augmented Rotator Cuff Tendon Repairs, Amit Aurora, Jesse A. Mccarron, Antonie J. Van Den Bogert, Jorge E. Gatica, Joseph P. Iannotti, Kathleen A. Derwin

Mechanical Engineering Faculty Publications

Background

Scaffolds continue to be developed and used for rotator cuff repair augmentation; however, the appropriate scaffold material properties and/or surgical application techniques for achieving optimal biomechanical performance remains unknown. The objectives of the study were to simulate a previously validated spring-network model for clinically relevant scenarios to predict: (1) the manner in which changes to components of the repair influence the biomechanical performance of the repair and (2) the percent load carried by the scaffold augmentation component.

Materials and methods

The models were parametrically varied to simulate clinically relevant scenarios, namely, changes in tendon quality, altered surgical technique(s), and …


A Novel Method For Determining Acetabular Orientation, Sean Higgins 2012 Virginia Commonwealth University

A Novel Method For Determining Acetabular Orientation, Sean Higgins

Theses and Dissertations

Enhanced knowledge of the acetabulum is of paramount importance in the diagnostic, planning, and execution stages of procedures and treatments targeting the hip joint. The convoluted and highly variable morphology of the structures comprising the bony pelvis make ascertaining measures of the acetabulum challenging. Furthermore, current methods for determining acetabular orientation assume symmetry between the separate halves of the pelvis by utilizing a coordinate system based on bilateral landmarks. The purpose of this study was to determine the three-dimensional orientation of the entire acetabulum. For this research, an improved programmatic method was developed for determining acetabular orientation using three-dimensional data. …


Changes In In Vivo Knee Contact Forces Through Gait Modification, Allison Kinney, Thor F. Besier, Amy Slider, Scott L. Delp, Darryl D. D'Lima, Benjamin J. Fregly 2012 University of Dayton

Changes In In Vivo Knee Contact Forces Through Gait Modification, Allison Kinney, Thor F. Besier, Amy Slider, Scott L. Delp, Darryl D. D'Lima, Benjamin J. Fregly

Mechanical and Aerospace Engineering Faculty Publications

Gait modification represents a non-invasive method for reducing knee joint loading in patients with knee osteoarthritis. Previous studies have shown that a variety of gait modifications are effective in reducing the external knee adduction moment. The external knee adduction moment is often used as a surrogate measure of medial compartment force. However, a recent study showed that reductions in the external knee adduction moment do not guarantee reductions in medial compartment loads. Therefore, direct measurement of changes in knee contact force is important for determining the effectiveness of gait modifications. A previous study found that medial thrust gait and walking …


Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence On Scan Direction And Velocity, Tiantian Xu 2012 University of Nebraska-Lincoln

Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence On Scan Direction And Velocity, Tiantian Xu

Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research

Cardiovascular disease is the leading cause death in the United States. Although emergency surgery and medicine can be used for cardiovascular disease treatment, the survivors will suffer for it afterwards. Ultrasound blood flow measurement provides a noninvasive way for cardiovascular diseases diagnosis. In this dissertation, three algorithms for blood flow velocity measurements were investigated and optimized. Feature tracking has been previously proposed for vector velocity measurement. In Chapter 3, the optimal amplitude and time thresholds for feature extraction were investigated to minimize flow estimate variance while providing sufficient spatial and temporal coverage of flow area. A new method of lateral …


Upper Extremity Biomechanical Model For Evaluation Of Pediatric Joint Demands During Wheelchair Mobility, Alyssa J. Paul, Brooke A. Slavens, Adam Graf, Joseph Krzak, Lawrence Vogel, Gerald F. Harris 2012 Marquette University

Upper Extremity Biomechanical Model For Evaluation Of Pediatric Joint Demands During Wheelchair Mobility, Alyssa J. Paul, Brooke A. Slavens, Adam Graf, Joseph Krzak, Lawrence Vogel, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

Current methods for evaluating upper extremity (UE) dynamics during pediatric wheelchair use are limited. We propose a new model to characterize UE joint kinematics and kinetics during pediatric wheelchair mobility. The bilateral model is comprised of the thorax, clavicle, scapula, upper arm, forearm, and hand segments. The modeled joints include: sternoclavicular, acromioclavicular, glenohumeral, elbow and wrist. The model is complete and is currently undergoing pilot studies for clinical application. Results may provide considerable quantitative insight into pediatric UE joint dynamics to improve wheelchair prescription, training and long term care of children with orthopaedic disabilities.


Storage And Loss Moduli Of Bone In Osteogenesis Imperfecta (Oi), Carolyne Albert, John Jameson, Jeffrey Toth, Peter A. Smith, Gerald F. Harris 2012 Marquette University

Storage And Loss Moduli Of Bone In Osteogenesis Imperfecta (Oi), Carolyne Albert, John Jameson, Jeffrey Toth, Peter A. Smith, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

No abstract provided.


Understanding The In Vivo Uptake Kinetics Of A Phosphatidylethanolamine-Binding Agent 99mTc-Duramycin, Said H. Audi, Zhixin Li, Joseph Capacete, Yu Liu, Wei Fang, Laura G. Shu, Ming Zhao 2012 Marquette University

Understanding The In Vivo Uptake Kinetics Of A Phosphatidylethanolamine-Binding Agent 99mTc-Duramycin, Said H. Audi, Zhixin Li, Joseph Capacete, Yu Liu, Wei Fang, Laura G. Shu, Ming Zhao

Biomedical Engineering Faculty Research and Publications

Introduction

99mTc-Duramycin is a peptide-based molecular probe that binds specifically to phosphatidylethanolamine (PE). The goal was to characterize the kinetics of molecular interactions between 99mTc-Duramycin and the target tissue.

Methods

High level of accessible PE is induced in cardiac tissues by myocardial ischemia (30 min) and reperfusion (120 min) in Sprague–Dawley rats. Target binding and biodistribution of 99mTc-duramycin were captured using SPECT/CT. To quantify the binding kinetics, the presence of radioactivity in ischemic versus normal cardiac tissues was measured by gamma counting at 3, 10, 20, 60 and 180 min after injection. A partially inactivated form of …


Measurement Of The Oxidation State Of Mitochondrial Cytochrome C From The Neocortex Of The Mammalian Brain, Y. Sakata, M. Abajian, M. O. Ripple, R. Springett 2012 Dartmouth College

Measurement Of The Oxidation State Of Mitochondrial Cytochrome C From The Neocortex Of The Mammalian Brain, Y. Sakata, M. Abajian, M. O. Ripple, R. Springett

Dartmouth Scholarship

Diffuse optical remission spectra from the mammalian neocortex at visible wavelengths contain spectral features originating from the mitochondria. A new algorithm is presented, based on analytically relating the first differential of the attenuation spectrum to the first differential of the chromophore spectra, that can separate and calculate the oxidation state of cytochrome c as well as the absolute concentration and saturation of hemoglobin. The algorithm is validated in phantoms and then tested on the neocortex of the rat during an anoxic challenge. Implementation of the algorithm will provide detailed information of mitochondrial oxygenation and mitochondrial function in physiological studies of …


Digital Commons powered by bepress