Thin-Film Sol-Gel As Controlled Delivery Platform For Neural Microelectrodes,
2014
Robert Morris University
Thin-Film Sol-Gel As Controlled Delivery Platform For Neural Microelectrodes, Margaret A. Harden, Matthew D. Mcdermott, Kevin J. Otto
The Summer Undergraduate Research Fellowship (SURF) Symposium
Long-term efficacy of neural implantation devices is a persisting challenge in neural engineering and rehabilitation. Upon implantation of a neural device, the foreign body response (FBR) is triggered and glial cells form a sheath around the electrode array. This sheath isolates the array from the rest of the brain both mechanically and electrically. Tetramethyl orthosilicate (TMOS), a thin-film polymer, has been shown to not negatively impact the impedance and charge-carrying capacity, as well as offer a controlled delivery method to deliver pharmaceuticals to mitigate inflammation without significant effect to device design. Using an in vitro protein delivery model to analyze …
Tissue Engineering: Applications In Developmental Toxicology,
2014
Purdue University
Tissue Engineering: Applications In Developmental Toxicology, Stephanie N. Thiede, Nimisha Bajaj, Kevin Buno, Sherry L. Voytik-Harbin
The Summer Undergraduate Research Fellowship (SURF) Symposium
In vivo toxicology assays are expensive, low-throughput, and often not predictive of a human response. Three-dimensional in vitro human cell-based tissue systems incorporating cell-cell and cell-matrix interactions have promise to provide high-throughput, physiologically-relevant information on the mechanism of the toxin and a more accurate assessment of the toxicity of a chemical before progression to human trials. Quantification of the disruption of vasculogenesis, the de novo formation of blood vessels from endothelial progenitor cells, can serve as an appropriate indicator of developmental toxicity since vasculogenesis is critical to the early development of the circulatory system. The current routinely used in vitro …
Multi-Channel Analysis For Gradient Artifact Removal From Concurrent Eeg-Fmri Studies,
2014
Purdue University
Multi-Channel Analysis For Gradient Artifact Removal From Concurrent Eeg-Fmri Studies, Miguel R. Castellanos, Zhongming Liu
The Summer Undergraduate Research Fellowship (SURF) Symposium
Concurrent electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) recordings are susceptible to large amounts of noise due to the static and dynamic magnetic fields present inside the MR scanner. EEG-fMRI studies are conducted to provide better spatial and temporal resolution for each recording, respectively, but the artifacts found in the EEG render the data impossible to interpret. Past studies have focused on signal post-processing techniques which are able to effectively remove noise upon the completion of a study, but there are no techniques able to process the data in real-time without extensive calibration. This research addresses this issue by …
Medical Applications Of Mrc,
2014
Purdue University
Medical Applications Of Mrc, Kyle Thackston, Henry Mei, Pedro Irazoqui
The Summer Undergraduate Research Fellowship (SURF) Symposium
Consistent powering is a limiting reagent for many medical implants and sensors. Powering in-vivo devices in animal studies requires either transcutaneous wiring (limiting mobility and increasing the chance of infection) or an implanted battery (limited lifetime and limits size of device). Wireless power transfer (WPT) would be able to overcome these challenges and permit the use of more advanced implantable devices in a research setting. Magnetic resonance coupling (MRC), an advanced form of inductive charging, allows good transfer efficiencies over significant air gaps, but works best a specific location and frequency, limiting mobility in animal studies. Using band-pass filter theory, …
Three Dimensional Quantification Of Angiotensin Ii-Induced Murine Abdominal Aortic Aneurysms Using High Frequency Ultrasound,
2014
Purdue University
Three Dimensional Quantification Of Angiotensin Ii-Induced Murine Abdominal Aortic Aneurysms Using High Frequency Ultrasound, Amelia R. Adelsperger, Alexa A. Yrineo, Hilary D. Schroeder, Ashley Nicole Blaize, Katherine E. Wilson, Evan H. Phillips, Frederick W. Damen, Craig J. Goergen
The Summer Undergraduate Research Fellowship (SURF) Symposium
Abdominal aortic aneurysms (AAAs), a localized dilation of the vessel wall of 50% or more above normal, claims approximately 14,000 U.S. lives yearly due to aortic rupture. This commonly asymptomatic disease can only be treated by endovascular stent grafts or invasive surgery, usually after the AAA diameter reaches 5 cm. Because these treatment methods carry serious risk, stem cell therapy is being explored in order to provide a low risk option for managing smaller AAAs. To determine if stem cell therapy, once administered, could stabilize or reduce AAA growth, baseline 3D ultrasound measurements in a control group were first needed. …
Estimating Fluid Local Velocity Within A Novel 3d Collagen Matrix Perfusion System,
2014
University of Kansas
Estimating Fluid Local Velocity Within A Novel 3d Collagen Matrix Perfusion System, Ana M. Villanueva, Sherry L. Voytik, Kevin P. Buno
The Summer Undergraduate Research Fellowship (SURF) Symposium
Traditional cell culture, performed on flat surfaces under static conditions, does not accurately represent physiologic conditions. As an alternative, groups have applied interstitial fluid flow (0.1-2.0 µm/s) through a 3D cell-embedded extracellular matrix (ECM). Cells sense the flow via mechanotransduction, a process by which cells sense mechanical forces and resultantly respond with biochemical signaling. Previous work demonstrates enhanced cell morphogenesis under interstitial flow conditions. However, fluid flow is poorly described within these systems, stressing the need for a well-characterized 3D interstitial flow system. Understanding fluid mechanics within a perfusion system will help elucidate cellular response to flow-induced mechanical forces.
The …
Tumor-Microenvironment-On-Chip To Mimic Tumor Heterogeneity,
2014
Purdue University
Tumor-Microenvironment-On-Chip To Mimic Tumor Heterogeneity, Victoria Noe-Kim, Altug Ozcelikkale, Bumsoo Han
The Summer Undergraduate Research Fellowship (SURF) Symposium
Ductal Carcinoma In Situ (DCIS) is a non-invasive cancer that forms around breast milk ducts that can potentially progress into invasive breast cancer if untreated. Lack of models to study its diverse pathophysiology and differential response to treatments poses a challenge to develop standard treatment modalities with improved therapeutic outcomes. The traditional in vitro models such as cell monolayer are convenient but insufficient to represent the physiological characteristics of DCIS tumor microenvironment and often fail to predict clinical outcomes. The animal models effectively simulate the in vivo environment but also lack the ability to control the environmental parameters to match …
Quantification Of Lps Eluate From Coated Microelectrode Devices,
2014
Columbia University
Quantification Of Lps Eluate From Coated Microelectrode Devices, Jahrane A. Dale, Janak Gaire, Kevin J. Otto
The Summer Undergraduate Research Fellowship (SURF) Symposium
Penetrating microelectrode arrays have a great potential to be used as control and communication interfaces for neuroprosthetics. A persistent obstacle in the clinical implementation of microelectrode arrays is the chronic degradation of these devices, putatively due to the foreign body response. Though researchers have studied the progression of the foreign body response and the effect of anti-inflammatory drugs on the efficacy of the implant, the exact biological mechanisms of implant degradation are not fully understood. To more closely investigate the effect of the foreign body response on device degradation, neuroinflammation can be exacerbated by coating dummy electrodes implanted into mice …
Nonlinear Optical Microscopy Of Murine Abdominal Aortic Aneurysm,
2014
University of Arkansas
Nonlinear Optical Microscopy Of Murine Abdominal Aortic Aneurysm, Katherine E. Wilson, Alexa A. Yrineo, Amelia J. Adelsperger, Hilary D. Schroeder, Delong Zhang, Jesse Zhang, Chien-Sheng Liao, Frederick W. Damen, Ji-Xin Cheng, Evan H. Phillips, Craig J. Goergen
The Summer Undergraduate Research Fellowship (SURF) Symposium
Abdominal aortic aneurysm (AAA) is a cardiovascular disease characterized by dilation and weakening of the vessel wall. AAA rupture is responsible for approximately 14,000 deaths annually in the United States [1]. Nonlinear optical (NLO) microscopy presents new possibilities for analyzing AAA tissue samples from murine models. Common NLO techniques are two-photon excitation fluorescence (TPEF), which detects the intrinsic autofluorescent properties of elastin, and second-harmonic generation (SHG), which is specific for collagen fibrils. Elastin and collagen, two major extracellular matrix components, help the aortic wall withstand internal pressure. Murine AAAs were created through 1) subcutaneous continuous systemic infusion of angiotensin II …
Chronic Brain Stimulation Using Micro-Ecog Devices,
2014
Purdue University
Chronic Brain Stimulation Using Micro-Ecog Devices, Hayden C. Carney, Roy Lycke, Kevin J. Otto, Amelia A. Schendel, Justin Williams
The Summer Undergraduate Research Fellowship (SURF) Symposium
Recording and stimulating brain activity has had great success both as a research tool and as a clinical technique. Neural prosthetics can replace limbs, restore hearing, and treat disorders like Parkinson’s and epilepsy, but are relatively crude. Current neural prosthetic systems use penetrating electrodes to achieve high precision, but the invasive nature of these devices provoke a strong immune response that limits chronic use. (Polikov et al) In our study we evaluate micro-electrocortiographic (micro-ECoG) devices which sit under the skull and on the surface of the brain for stimulation over chronic timescales. We anticipate these devices with their less invasive …
Characterization Of Swelling Ratio And Water Content Of Hydrogels For Cartilage Engineering Applications,
2014
Purdue University
Characterization Of Swelling Ratio And Water Content Of Hydrogels For Cartilage Engineering Applications, Emily E. Gill, Renay S.-C. Su, Julie C. Liu
The Summer Undergraduate Research Fellowship (SURF) Symposium
Due to the high prevalence of arthritis and cartilage-related injuries, tissue engineers are studying ways to grow cartilage tissue replacements. Resilin, an elastomeric protein found in insect cuticles, is known for its extraordinary resilience and elasticity. In previous studies, recombinant resilin-based hydrogels, or cross-linked protein networks, exhibited potential for use in cartilage tissue scaffolds. Our lab successfully developed resilin-based proteins with a sequence based on the mosquito gene and showed that resilin-based hydrogels possess mechanical properties of the same order of magnitude as native articular cartilage. In addition, these mechanical properties can be controlled by changing the protein concentration. To …
Design And Fabrication Of A Novel Electrospinning System For Musculoskeletal Tissue Regeneration,
2014
Purdue University
Design And Fabrication Of A Novel Electrospinning System For Musculoskeletal Tissue Regeneration, Carter L. Chain, Maggie R. Del Ponte, Meng Deng, Feng Yue, Shihuan Kuang
The Summer Undergraduate Research Fellowship (SURF) Symposium
Disease and injury to human tissue, especially musculoskeletal tissue, is a prevalent concern to the public, affecting millions of people each year. Current treatment options involving autografts and allografts are hindered by limited availability and risk of immunogenicity, respectively. In order to overcome these limitations, a transdisiplinary regenerative engineering strategy has emerged with a focus on the development of biomimetic scaffolds that closely mimic the properties of the native tissues. For example, the structure of muscle tissue is characterized by oriented muscle fibers. However, fabrication of aligned nanofiber structures that mimic the anisotropic organization of muscle presents significant engineering challenges. …
Wirelessly Powered And Transmitting Current Sensing Device,
2014
Purdue University
Wirelessly Powered And Transmitting Current Sensing Device, Christopher Quinkert, Steven Lee, Pedro Irazoqui
The Summer Undergraduate Research Fellowship (SURF) Symposium
As the rate of incidence of diabetes increases in the modern world, more accurate and reliable methods of glucose detection must be developed for patients with diabetes. Currently, 25.8 million people have diabetes in the United States alone and account for $174 billion in healthcare costs annually [1]. Devices that can be used without the need for as much patient interaction, regular replacement, or great patient expenses would be a large step forward in the ability of doctors and patients to effectively manage diabetes. To measure glucose concentrations in vivo, a biosensor is used to transduce glucose to an electrical …
The Role Of Metal Oxide Layers In The Sensitivity Of Lactate Biosensors Subjected To Oxygen-Limited Conditions,
2014
Purdue University
The Role Of Metal Oxide Layers In The Sensitivity Of Lactate Biosensors Subjected To Oxygen-Limited Conditions, Elizabeth Andreasen, Lia Stanciu, Aytekin Uzunoglu
The Summer Undergraduate Research Fellowship (SURF) Symposium
Amperometric lactate biosensors are used to detect lactate concentration in blood and tissues, which is integral in identifying cyanide poisoning, septic shock, and athletic condition. The construction of lactate biosensors with high sensitivity, selectivity, and stability is imperative to diagnose and determine these medical conditions. Lactate detection is currently limited to oxygen-rich environments due to the fact that oxygen is a limiting factor in the lactate reaction. To circumvent this problem, researchers have developed mediators or alternate, oxygen-free enzymes to improve sensitivity. In our study, ceria (CeO2) with high oxygen storage capacity (OSC) was introduced to the enzyme …
Real-Time Bio Sensing Using Micro-Channel Encapsulated Mems Resonators,
2014
University of Denver
Real-Time Bio Sensing Using Micro-Channel Encapsulated Mems Resonators, Ayesha Iqbal
Electronic Theses and Dissertations
This work presents a label-free bio-molecular detection technique based on realtime monitoring of the resonant frequency of micromechanical thermal-piezoresistive rotational mode disk resonators encapsulated in microfluidic channels. Mass loading via adsorption of molecular layers on the surface of such devices results in a frequency shift. In order to provide a reliable platform for sample-resonator interactions and to protect the resonators from contaminants, the resonators were encapsulated in PDMS-based microfluidic channels. Micro-channel encapsulation also allows insulation of electrical signals from the analyte solution. To characterize the performance of such devices as real-time label-free bio-molecular detectors, the strong non-covalent binding of Avidin …
Nerve Fiber Diameter Measurements Using Hematoxylin And Eosin Staining And Brightfield Microscopy To Assess The Novel Method Of Characterizing Peripheral Nerve Fiber Distributions By Group Delay,
2014
California Polytechnic State University, San Luis Obispo
Nerve Fiber Diameter Measurements Using Hematoxylin And Eosin Staining And Brightfield Microscopy To Assess The Novel Method Of Characterizing Peripheral Nerve Fiber Distributions By Group Delay, Jorge Arturo Vazquez
Master's Theses
Peripheral neuropathies are a set of common diseases that affect the peripheral nervous system, causing damage to vital connections between various parts of the body and the brain and spinal cord. Different clinical conditions are known to selectively impact various size nerve fibers, which often makes it difficult to diagnose which peripheral neuropathy a patient might have. The nerve conduction velocity diagnostic test provides clinically useful information in the diagnosis of some peripheral neuropathies. This method is advantageous because it tends to be minimally invasive yet it provides valuable diagnostic information. However, this test does not determine characteristics of peripheral …
Investigating Hemodynamic Responses To Electrical Neurostimulation,
2014
California Polytechnic State University, San Luis Obispo
Investigating Hemodynamic Responses To Electrical Neurostimulation, Sean Youra
Master's Theses
Since the 1900s, the number of deaths attributable to cardiovascular disease has steadily risen. With the advent of antihypertensive drugs and non-invasive surgical procedures, such as intravascular stenting, these numbers have begun to level off. Despite this trend, the number of patients diagnosed with some form of cardiovascular disease has only increased. By 2030, prevalence of coronary heart disease is expected to increase approximately by 18% in the United States. By 2050, prevalence of peripheral arterial occlusive disease is expected to increase approximately by 98% in the U.S. No single drug or surgical intervention offers a complete solution to these …
A Rubric For Electrochemical Testing Of Metallic Biomaterials,
2014
California Polytechnic State University, San Luis Obispo
A Rubric For Electrochemical Testing Of Metallic Biomaterials, Frederick G. De La Fuente
Master's Theses
Corrosion is a major factor for the failure of metallic medical implants. Testing a metal’s suseptability to corrosion prior to implantation is key to a successful implantation. Electrochemical processes were used in this study to evaluate the characteristics of corrosion of both AISI 316 stainless steel and titanium alloy Ti6Al4V, welded and non-welded. Linear, potentiodynamic, and cyclic polarization curves were produced by the PARC 2273 potentiostat showing the corrosion tendencies of the metals in four unique solutions 3.5% NaCl, 0.35% NaCl, phosphate buffered saline solution (PBS), and Butterfield phosphate buffered solution (BPS). The concentration of chloride ions in solutions affected …
Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus,
2014
California Polytechnic State University, San Luis Obispo
Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong
Master's Theses
For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …
Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis),
2014
University of Nebraska-Lincoln
Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.
Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …