Functional Comparison Of Conventional Afos With The Dynamic Response Afo,
2016
Marquette University
Functional Comparison Of Conventional Afos With The Dynamic Response Afo, Mitchell Ruble
Master's Theses (2009 -)
Ankle foot orthoses (AFOs) are commonly prescribed to provide stability and foot clearance for patients with weakened or injured musculature. The Dynamic Response AFO (DRAFO) was designed to improve proprioception at heel strike. The design includes a rigid outer shell with a cut out heel and a soft inner lining; it is typically aligned in plantarflexion and may incorporate external heel wedges. The objective of this study was to investigate the effects of the DRAFO design features and contrast its biomechanical function with that of conventional locked and articulating AFOs. The research hypotheses were: 1) DRAFO-assisted gait parameters (e.g. ankle …
Hydrothermal Synthesis And Characterisation Of Bioactive Glass-Ceramic Nanorods,
2016
Missouri University of Science and Technology
Hydrothermal Synthesis And Characterisation Of Bioactive Glass-Ceramic Nanorods, Ehsan Zeimaran, Sara Pourshahrestani, Seyed Farid Seyed Shirazi, Belinda Pingguan-Murphy, Nahrizul Adib Kadri, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
In this study fabrication of rod-like bioactive glass-ceramics (BGCs) using hydrothermal treatment based on a sol-gel precursor is reported for the first time. BGCs with composition 58 wt% SiO2, 33 wt% CaO and 9 wt% P2O5 were synthesized in different thermal conditions (200 and 220 °C) and characterised with regard to morphology, chemical composition and crystallinity. The bioactivity of the materials was assessed by immersion in simulated body fluid for up to 7 days. The results revealed that as the reaction temperature increased from 200 to 220 °C, the diameter of rods was reduced from …
Modification Of Offset Hip Impactor,
2016
KTH, Stockholm, Sweden
Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor
Mechanical Engineering
More than 300,000 total hip replacement surgeries are performed in the US each year. Minimally invasive total hip replacement surgery requires modified tools to access the smaller incision. An offset hip impactor was redesigned to improve tool lifetime, ease of use, and manufacturing cost. The redesigned tool had an increased lifetime and a significant reduction in the number of parts. The report contains detail drawings, a manufacturing plan, and physical testing results.
Prosthetic Socket Cooling System,
2016
California Polytechnic State University – San Luis Obispo
Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai
Mechanical Engineering
A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …
Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves,
2016
California Polytechnic State University, San Luis Obispo
Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang
Mechanical Engineering
Confidential
Prosthetic Leg Kit For Deployment In Developing Countries,
2016
California Polytechnic State University, San Luis Obispo
Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo
Biomedical Engineering
The World Health Organization estimates that over 30 million people require some sort of prosthetic technology. However, traditional prosthetic fitting practices take a lot of time and cost a lot of money, making them inaccessible to millions of people around the world. StandUP Worldwide is an interdisciplinary project team devoted to creating low-cost prosthetic technologies for use around the world, especially in resource poor areas. They are currently developing a low cost, below-the-knee prosthetic kit that can be easily deployed in a resource-poor area. The following presents their solution for a below-the-knee prosthetic socket, foot, and leg.
Raman Spectroscopic Analysis Of Fingernail Clippings Can Help Differentiate Between Postmenopausal Women Who Have And Have Not Suffered A Fracture,
2016
Missouri University of Science and Technology
Raman Spectroscopic Analysis Of Fingernail Clippings Can Help Differentiate Between Postmenopausal Women Who Have And Have Not Suffered A Fracture, James R. Beattie, Niamh M. Cummins, Clare Caraher, Olive M. O'Driscoll, Aruna T. Bansal, Richard Eastell, Stuart H. Ralston, Michael D. Stone, Gill Pearson, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Raman spectroscopy was applied to nail clippings from 633 postmenopausal British and Irish women, from six clinical sites, of whom 42% had experienced a fragility fracture. The objective was to build a prediction algorithm for fracture using data from four sites (known as the calibration set) and test its performance using data from the other two sites (known as the validation set). Results from the validation set showed that a novel algorithm, combining spectroscopy data with clinical data, provided area under the curve (AUC) of 74% compared to an AUC of 60% from a reduced QFracture score (a clinically accepted …
Localized Immunotherapy Delivery Using Injectable In Situ Forming Chitosan Hydrogel,
2016
University of Arkansas, Fayetteville
Localized Immunotherapy Delivery Using Injectable In Situ Forming Chitosan Hydrogel, Seth Washispack
Biomedical Engineering Undergraduate Honors Theses
Cytokine-based cancer immunotherapies stimulate a host’s immune system to fight cancer. In particular, interleukin-12 (IL-12), a potent pro-inflammatory cytokine, has demonstrated the ability to eliminate tumors in a number of preclinical models. Toxicities associated with the systemic delivery of IL-12 have precluded its use in the clinic. We are developing a novel chitosan-based hydrogel to maintain high local concentrations of cytokines, such as IL-12, in the tumor while minimizing its systemic dissemination. This hydrogel was found to form spontaneously within ten seconds of mixing two proprietary components. To increase the usefulness of the hydrogel, an efficient mixing and delivery system …
Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications,
2016
University of Arkansas, Fayetteville
Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson
Graduate Theses and Dissertations
There exists a need for research of optical methods capable of image cytometry suitable for point-of-care technology. To propose am optical approach with no moving parts for simplification of mechanical components for the further development of the technology to the poin-of-care, a linear sensor with push broom translation method. Push broom translation is a method of moving objects by the sensor for an extended field of view. A polydimethylsiloxane (PDMS) microfluidic chamber with a syringe pump was used to deliver objects by the sensor. The volumetric rate of the pump was correlated to the integration time of the sensor to …
Design Of A 3d-Printed Device For Diffuse Reflectance Spectroscopy Calibration As A Step Towards Clinical Translation,
2016
University of Arkansas, Fayetteville
Design Of A 3d-Printed Device For Diffuse Reflectance Spectroscopy Calibration As A Step Towards Clinical Translation, Nontapoth Vongkittiargorn
Biomedical Engineering Undergraduate Honors Theses
The diffusive reflectance and spectroscopic microendoscopy (DRSME) is a multimodal imaging system that harnesses its usefulness from different light sources. One of the modalities, diffuse reflectance spectroscopy (DRS), has been used in our lab to investigate optical properties of epithelial tissues using a broadband white light as the main source. Calibration of DRS is required as it can obtain the maximum intensity and convert it to absolute reflectance. Current manual-adjusted calibration can be lengthy and often lead to inconsistent results. Therefore, a new method of calibration is introduced where additive manufacturing (or 3D printing) technology is fully utilized.
The instrumentation …
Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures,
2016
University of Nevada, Las Vegas
Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li
UNLV Theses, Dissertations, Professional Papers, and Capstones
An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …
Intravital Microscopy Of Tumor Oxygenation And Glycolytic Demand,
2016
University of Arkansas, Fayetteville
Intravital Microscopy Of Tumor Oxygenation And Glycolytic Demand, Jesse D. Ivers
Biomedical Engineering Undergraduate Honors Theses
There is growing concern about the over treatment of cancer because treatments are based primarily on tumor anatomy. In this study, we aim to begin the process of addressing that issue by developing an intravital technique for optically analyzing tumor biology. Two traits were identified as having significant importance in the aggression of a tumor, vascular oxygenation (SO2) and glycolytic demand. Dorsal skin flap window chambers were implanted and 4T1 and 67NR cancer cells were injected to provide a tumor model for the development of this intravital quantification technique. This study provides a detailed protocol from instrumentation setup to surgical …
Design Of Exercise Equipment For Wheelchair Users: A Case Study In Accessibility Standards,
2016
University of Connecticut
Design Of Exercise Equipment For Wheelchair Users: A Case Study In Accessibility Standards, Kate Craddock Rescsanszky
Honors Scholar Theses
Engineers must consider a number of aspects of every project they work on. Accessibility is one aspect that presents a unique challenge. Rather than being based on absolute material parameters, accessibility is based on how people interact with technology and their built environment. Since 1990, the Americans with Disabilities Act has been the predominant standard in accessibility because of its wide reach and legal mandate. In addition to the ADA, the ASTM and the Institute for Universal Design offer helpful guidelines for designing for accessibility. However, in addition to standards, guidelines, and recommendations, it is important to consult the intended …
Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation,
2016
University of Nebraska-Lincoln
Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Acute respiratory distress syndrome (ARDS) is a pulmonary disease that causes hypoxemia and respiratory failure. The mortality rate for ARDS ranges between 27% and 45%. Current treatments including mechanical ventilation and extracorporeal membrane oxygenation (ECMO) are often associated with high risk complications including barotrauma, infection, thrombosis, and hemorrhage. Alternative pulmonary support techniques are needed to improve the survival rate of patients suffering from ARDS. Previous studies introducing pure O2 gas, perfluorocarbons and red blood cells into the intraperitoneal (IP) cavity have reported no effect or only a mild increase in oxygenation. Here we report peritoneal membrane oxygenation (PMO) using …
Design Of Medical Devices For Diagnostics In The Gastrointestinal System,
2016
University of Nebraska-Lincoln
Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
This thesis presents the design, controls, and testing of two systems: a novel colonoscope locomotion design for diagnostics, and a biosensor capsule that implants a sensor in the small intestine. Each system requires special design considerations for use in the gastrointestinal system.
Colonoscopy procedures are recommended as a screening for colon cancer and related conditions after the age of 50. The need for an improved colonoscope that reduces the colonoscopy time and patient discomfort is apparent. The semi-autonomous device presented here could likely reduce the colonoscopy procedure time by allowing the physician to focus more on the diagnosis and less …
Under The Needle: Ergonomic Issues With Lethal Injection Protocols,
2016
University of Central Florida
Under The Needle: Ergonomic Issues With Lethal Injection Protocols, Gabriella Hancock
Human Factors and Applied Psychology Student Conference
The institution of capital punishment represents one of the most contentious issues affecting societies today; and while the practice is only implemented in 58 countries, the controversy affects the world at large as over 60% of the human population lives in nations that condone the death penalty (Hali, 2015). In the United States, people who support capital punishment believe the practice to be an effective crime deterrent for potential criminals and therefore a prospective protective measure for law abiding citizens. Moreover, advocates defend their position by forwarding the argument that executions are ‘humane’; that use of lethal injection ensures that …
Circle Of Willis Model For Transcranial Doppler Ultrasound Training,
2016
University of Nebraska-Lincoln
Circle Of Willis Model For Transcranial Doppler Ultrasound Training, Conner J. Beyersdorf, Ben Hage, Greg Bashford
UCARE: Research Products
Transcranial Doppler (TCD) ultrasound is a technique involving the use of high frequency transmitters to measure intracranial blood flow. The brain is supplied by blood in an arterial anastomosis called the Circle of Willis. Using TCD ultrasound on the circle is difficult and requires practice and teaching. A functional model of the Circle of Willis could prove to be a valuable teaching tool. Through the use of AutoCAD and 3D printing software, an anatomically accurate model was created and set in gelatin phantom inside of a plastic skull. Milk was pumped through the model with a peristaltic pump to simulate …
Structural-Functional Brain Connectivity Underlying Integrative Sensorimotor Function After Stroke,
2016
Marquette University
Structural-Functional Brain Connectivity Underlying Integrative Sensorimotor Function After Stroke, Benjamin Thomas Kalinosky
Dissertations (1934 -)
In this dissertation research project, we demonstrated the relationship between the structural and functional connections across the brain in stroke survivors. We used this information to predict arm function in stroke survivors, suggesting that the tools developed through this research will be useful for prescribing individualized rehabilitation strategies in people after stroke. Current clinical methods for rehabilitating sensorimotor function after stroke are not based on the locus of injury in the brain. Instead, therapies are generalized, treating symptoms such as weakness and spasticity. This results in outcomes that are highly variable, with severity of impairment immediately following stroke as the …
The Role Of Poly(Acrylic Acid) In Conventional Glass Polyalkenoate Cements,
2016
Missouri University of Science and Technology
The Role Of Poly(Acrylic Acid) In Conventional Glass Polyalkenoate Cements, Adel M.F. Alhalawani, Declan J. Curran, Daniel Boyd, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glass polyalkenoate cements (GPCs) have been used in dentistry for over 40 years. These novel bioactive materials are the result of a reaction between a finely ground glass (base) and a polymer (acid), usually poly (acrylic acid) (PAA), in the presence of water. This article reviews the types of PAA used as reagents (including how they vary by molar mass, molecular weight, concentration, polydispersity and content) and the way that they control the properties of the conventional GPCs (CGPCs) formulated from them. The article also considers the effect of PAA on the clinical performance of CGPCs, including biocompatibility, rheological and …
Design And Validation Of A Fall Detection Application For Ios,
2016
California Polytechnic State University, San Luis Obispo
Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley
Master's Theses
Despite significant preventative efforts, falls continue to be a major source of morbidity and mortality among the elderly. Additionally, the fear of falling can be a major obstacle to independent living for otherwise self-sufficient individuals. This fear is significantly heightened in individuals who have sustained a fall and often results in self-imposed restrictions on mobility and exercise, causing weakening in these individuals and further exacerbating the danger. Much time has been spent developing alert systems in an attempt to mitigate these problems. Unfortunately these systems typically involve dedicated monitoring centers and therefore often come with substantial upfront and recurring costs. …
