Articles 91 - 120 of 174

Full-Text Articles in Other Engineering

Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan Jun 2017

Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan

Fire Protection Engineering: Culminating Experience Project Reports

This report discusses the fire and life safety analysis of the existing fire protection features installed in the Recreation Center building on the California Polytechnic State University. The analysis is conducted using two different approaches, the prescriptive analysis of the building and the performance-based design analysis.

The prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code, such as structural fire protection, water-based suppression system, alarm and detection system, egress system, smoke control, and fire safety management plan. The egress system failed when the old gym area was used as a fixed …


Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein Jun 2017

Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein

Fire Protection Engineering: Culminating Experience Project Reports

The ACME Semiconductor Foundry – Fab Expansion is a new four story addition to an existing four story foundry facility. The Fab Expansion is approximately 154,500 square feet in footprint area that is connected to an existing four-story Fab Building. This report has been prepared to identify the building’s fire protection and life safety features that must be provided in accordance with the applicable codes and standards. The ACME Semiconductor Fab Expansion will contain multiple separated uses and will be required to be constructed with Type I-B construction. Building Construction Documents are provided in Appendix A showing compliance with the …


Woodward Willis Building- Fire And Life Safety Evaluation, Jordan Nerat Jun 2017

Woodward Willis Building- Fire And Life Safety Evaluation, Jordan Nerat

Fire Protection Engineering: Culminating Experience Project Reports

This project report is an academic exercise, completed as part of the MS Fire Protection Engineering program at California Polytechnic State University. This project is a culminating report with regards to life safety analysis of the Woodward Willis Building located in Detroit Michigan, which utilizes the fundamental and applied courses of the fire protection engineering program.

The analysis is based on a prescriptive analysis of the building and its features, and also a performance analysis which entails the life safety aspect of the building. The analysis of the building is performed in accordance with NFPA 101 Life Safety Code 2015 …


Lax Continental Grand- Fire Protection And Life Safety Analysis, Aden Malek Stepanians Jun 2017

Lax Continental Grand- Fire Protection And Life Safety Analysis, Aden Malek Stepanians

Fire Protection Engineering: Culminating Experience Project Reports

A prescriptive analysis of the project building was conducted using the 2016 California Building & Fire Code along with current codes and standards pertaining to specific elements. Encompassed in this analysis is a review of the project building’s structural fire protection, water-based suppression systems, fire detection and alarm systems, smoke control and occupant egress.

Void of construction documentation, the analysis of the structural fire protection of the building was determined by evaluating the current design and use. The restricting factor that determine the construction type was the assembly use on the 6th floor. Other than Type I construction, assembly use …


Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen Mar 2017

Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen

Fire Protection Engineering: Culminating Experience Project Reports

The Robert E. Kennedy Library is located on Cal Poly Campus. The Library is a five-story building with different occupancies which consists of library areas, offices, mechanical equipment and storage areas. The building has a total area of 178 702 ft². The original code of construction for the Library was the 1976 Uniform Building code (UBC). However, the fire and life safety analysis of the building in this report is performed using: Egress: NFPA 101 LSC 2015, Water based suppression: NFPA 13, Structural fire protection: 2015 IBC, Fire detection, alarm and communication systems: NFPA 72, Performance based design: NFPA 101 …


Building- Fire Protection Analysis Report, Chris Schwendiman Mar 2017

Building- Fire Protection Analysis Report, Chris Schwendiman

Fire Protection Engineering: Culminating Experience Project Reports

The building in XXX was constructed in XXX. It was designed using the International Building Code (IBC). This fire protection analysis report will be reviewing the building based on the 2015 edition of the IBC including several performance based fire scenarios involving the smoke exhaust system.

The passive system section highlights the physical construction of the building. The building is a business occupancy with three separate stories including a penthouse which is included in the third story. The building has adequate fire ratings for a Type II-B construction except for heavy timber columns within the commons of the building. It …


Orfalea College Of Business Fire Safety Analysis, Garth Ornelas Mar 2017

Orfalea College Of Business Fire Safety Analysis, Garth Ornelas

Fire Protection Engineering: Culminating Experience Project Reports

The following report discusses the fire and life safety factors for the Orfalea College of Business Building located on the main campus of California Polytechnic State University in San Luis Obispo. The building functions are primarily administrative and academic in nature, with various lecture halls, offices, and labs located throughout the building. The Business Building was constructed in 1989 following the 1985 Uniform Building Code (UBC). For the purposes of this report, the building will be evaluated using the 2015 International Building Code, NFPA Life Safety Code Handbook (Thirteenth Edition), SFPE Handbook (4th and 5th Editions), and the NFPA handbooks …


Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves Mar 2017

Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves

Fire Protection Engineering: Culminating Experience Project Reports

This report covers the fire protection features of the Warren J. Baker Center for Science and Mathematics located on Cal Poly Campus San Luis Obispo California. The prescriptive analysis of the building will focus on the structural fire protection, egress, fire suppression, fire alarm and detection systems to determine if the meet current codes and standards. The performance based analysis will discuss certain methods and design fire scenarios that can be present within the building and the buildings ability to protect occupants until they can exit safely.

The purpose of this report is to determine if the selected building is …


Wistron Greentech, Mckinney, Tx- Life Safety Evaluation, Charles R. Cates Mar 2017

Wistron Greentech, Mckinney, Tx- Life Safety Evaluation, Charles R. Cates

Fire Protection Engineering: Culminating Experience Project Reports

A fire protection and life safety review of the Wistron GreenTech facility in McKinney, TX is performed. The facility was reviewed from both a prescriptive (building code) and performance based design per the codes summarized in the report. The prescriptive fire and life safety systems analyzed where the following: Building Code Analysis Including but not limited to: Occupancy classifications, Occupancy separations, Building height and areas, Type of construction, Fire resistive construction, Means of egress, Fire Alarm and Detection Systems, Automatic Fire Sprinklers & Water Supply, Special Hazards, Emergency Planning and Preparedness The prescriptive requirements in general where met, the exceptions …


Fire And Life Safety Evaluation Of Christopher Cohan Center, Mishuk Datta Mar 2017

Fire And Life Safety Evaluation Of Christopher Cohan Center, Mishuk Datta

Fire Protection Engineering: Culminating Experience Project Reports

A prescriptive and performance-based fire and life safety evaluation for Christopher Cohan Center is performed. The results and findings of the evaluations are conveyed in this report. Christopher Cohan Center was built in accordance with California Building Code (1992 Edition) and California Fire Code (1992 Edition). The current version (2015) of International Building Code is consulted for prescriptive evaluation. The protection requirements set forth in IBC are intended to limit the threat from stage fires to an audience, to reduce the likelihood of a large fire in the stage area and to reduce the possibility of irrational mass response. These …


Fire And Life Safety Report Orfalea College Of Business, Sulaiman Almohammadi Mar 2017

Fire And Life Safety Report Orfalea College Of Business, Sulaiman Almohammadi

Fire Protection Engineering: Culminating Experience Project Reports

A comprehensive fire and life safety analysis was performed on the Orfalea College of Business. The report covers the prescriptive analysis of the building and the performance-based design analysis. The prescriptive analysis includes assessment of the relevant codes for egress system, water-based suppression system, alarm and detection system, and structural fire protection. The egress analysis under the Life Safety Code 2015 found the building meets the requirements of occupant load to exceed exit capacity, number of exits and its location, travel distances. Four rooms on the second floor that have not met the common path of travel distances limits were …


Fire And Life Safety Evaluation Of The Christopher Cohan Center, Joakim Midtun Larsen Mar 2017

Fire And Life Safety Evaluation Of The Christopher Cohan Center, Joakim Midtun Larsen

Fire Protection Engineering: Culminating Experience Project Reports

This project is an academic exercise, as part of the MS Fire Protection Engineering program of California Polytechnic State University. The project is a culminating report with regards to life safety analysis of the Christopher Cohan Center of Cal Poly, which builds on the fundamental and applied courses of the program. The analysis is twofold, where the first part is a Prescriptive Analysis of the building and its features, followed by a Performance Based Life Safety Analysis. Both parts are performed in accordance with NFPA 101 Life Safety Code 2015 edition, Codes/Standards references within NFPA 101, and supplemented by methods …


Office Building- Fire Protection Systems Evaluation, Christine Newton Jun 2016

Office Building- Fire Protection Systems Evaluation, Christine Newton

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Life Safety Code (LSC) and fire protection systems evaluation of an office building located in Colorado. This report covers the prescriptive analysis of the building, as well as the performance‐based aspect of the evaluation.

The prescriptive analysis of this report includes assessment of the building code for structural design, means of egress, detection and notification systems, smoke control system, and the water‐ based fire suppression system for this building. The 2012 International Building Code (IBC) and the National Fire Protection Agency (NFPA) 101 LSC were used for the prescriptive based evaluation and the building was determined …


Sheraton Hotel- Life Safety Report, Raul M. Farfan Jun 2016

Sheraton Hotel- Life Safety Report, Raul M. Farfan

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the prescriptive life safety requirements for levels one (1) through four (4) of the Sheraton Hotel in downtown Phoenix. In addition, this report discusses two fire scenarios that evaluate the tenability during egress the in pre-function area on level two (2) and in the main ballroom on level three (3) of the hotel.

The prescriptive standards/codes used to evaluate the hotel are the International Building Code (IBC), International Fire Code (IFC), and applicable standards from the National Fire Protection Association (NFPA). Performance based analysis were conducted using Pathfinder, CFast, and Fire Dynamic Simulator (FDS). Two fire scenarios …


3-Bay Aircraft General Maintenance Hangar- United States Air Force, Zach Ataiyan Jun 2016

3-Bay Aircraft General Maintenance Hangar- United States Air Force, Zach Ataiyan

Fire Protection Engineering: Culminating Experience Project Reports

This report contains a prescriptive design analysis and a performance based design analysis for a newly constructed United States Air Force 3-Bay Aircraft General Maintenance Hangar and support spaces.

The prescriptive design analysis reviews the code requirements for fire suppression, fire alarm, life safety, and structural fire protection. Additionally, the hydraulic demands of the fire suppression system, and the voltage drop and power supply requirements of the fire alarm systems were calculated. The results of the analysis portray a compliant prescriptive design of the fire protection systems.

The performance based design analysis evaluates the hazards in the 3-bay facility for …


Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett Jun 2016

Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett

Fire Protection Engineering: Culminating Experience Project Reports

The fire protection and life safety systems for Building X were evaluated for compliance in accordance with applicable nuclear power plant non-power block regulatory requirements, NEIL, INPO, IBC, and NFPA design requirements, codes, and standards. Building X is a one-story building with two internal balconies with 10 occupants per balcony, which is made of non-combustible materials that also has a partial basement with concrete walls (is normally unoccupied), which houses potable water pumps and piping for the facility. Building X falls under the definition of mixed occupancy per the International Building Code (IBC) and the Life Safety Code (LSC). Since …


Regional Office Building- Fire And Life Safety Analysis, Peter Dwan Jun 2016

Regional Office Building- Fire And Life Safety Analysis, Peter Dwan

Fire Protection Engineering: Culminating Experience Project Reports

This report has two objectives: 1. To confirm that the Fire and Life Safety Systems of a project building satisfy applicable prescriptive code requirements, and 2. To evaluate how the Fire and Life Safety Systems perform when challenged by a credible fire scenario.

The three‐story, 31,430 sq. ft. project building is the regional office for an oil and gas company operating in Western Canada. The building includes an atrium which extends from the ground level, main floor to the third floor.

The Fire and Life Safety Systems within the scope of this study, include:

Fire Detection and Alarms Systems (FDAS) …


Orange Grove Library- Prescriptive And Performance-Based Fire And Life Safety Evaluation, David A. Boackle Jun 2016

Orange Grove Library- Prescriptive And Performance-Based Fire And Life Safety Evaluation, David A. Boackle

Fire Protection Engineering: Culminating Experience Project Reports

This report describes the analysis of the Orange Grove Library in Gulfport, Mississippi, using prescriptive and performance-based techniques to evaluate fire and life safety. The prescriptive analysis is broken down into four components: alarm, egress, structural and suppression. Prescriptive codes are written by consensus, such that adhering to these codes will produce a reasonable balance between cost, function and safety. The performance-based design analysis uses analytical tools to predict how this particular building would perform under specific fire conditions, chosen based on the actual building in place. Life safety is the primary goal of this analysis. Achievement of this goal …


Pitkin Charter School, Scott Decker Jun 2016

Pitkin Charter School, Scott Decker

Fire Protection Engineering: Culminating Experience Project Reports

The Loew’s Pitkin building is a renovation of a movie/stage theater built in 1929. Over the next three decades the neighborhood declined and the theater closed in the Nineteen Sixties. The building was then a church for a while and then retail space with the theater auditorium empty. The building was finally abandoned in the Seventies and deteriorated until the early part of the next century. The School board of New York City took possession of the vacant structure and turned it into PS 159. It is a grade school serving grades from kindergarten to fifth grade and special education. …


Analysis Of The Seattle Customer Delivery Center, Cynthia Wernet Jun 2016

Analysis Of The Seattle Customer Delivery Center, Cynthia Wernet

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this analysis is to assess how the Customer Delivery Center (CDC) satisfies prescriptive design requirements of the 2012 International Building Code (IBC) for fire exiting, structural design, smoke detection, alarm notification and communication and water-based fire suppression. A performance-based analysis is then performed using hand calculations and computer-based models to determine if the available safe egress time exceeds the required safe egress time from the building. In order to complete this analysis, the issued-for-construction design and the contractor submittals were made accessible by the owner’s fire protection engineer and the project management group overseeing construction. These documents …


Henderson Engineers Building- Fire Protection, Life Safety Code Compliance, And Key Issues Report, Alex Ataiyan Jun 2016

Henderson Engineers Building- Fire Protection, Life Safety Code Compliance, And Key Issues Report, Alex Ataiyan

Fire Protection Engineering: Culminating Experience Project Reports

A fire protection and life safety analysis of the Henderson Engineers, Inc. (HEI) building in Lenexa, KS (Kansas City) is performed. Both prescriptive and performance-based methods have been used to evaluate the building against the codes and standards of the 2012 International Building Code (IBC).

The following prescriptive fire protection and life safety systems were analyzed: Occupancy Classification, Building Construction Type, Fire Protection Features, Structural Fire Protection, Fire Barriers, Automatic Fire Sprinkler System, Fire Alarm System, and Means of Egress

During the prescriptive approach, the following deficiencies were identified: 1) As-builts indicate a horizontal assembly fire-resistance rating of only 1-hour, …


Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza Jun 2016

Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza

Fire Protection Engineering: Culminating Experience Project Reports

This project developed the traditional prescriptive-based design analysis of the fire protection features of an existing office high rise building in the city of Sao Paulo, in Brazil. The analysis was then complemented by performance-based analysis of the building. The building is a high rise office located in a metropolitan area, provided also with underground car parking garages and a small theater. The fire protection analysis was conducted based on the local Sao Paulo state fire codes, mainly the Sao Paulo State enactment (Decreto Nº56.819/2011) and Sao Paulo Fire Department Technical Instructions; and, in addition to the local codes, the …


New Burke Museum- Fire And Life Safety Overview And Atrium Design Analysis, Justin Schmidt Jun 2016

New Burke Museum- Fire And Life Safety Overview And Atrium Design Analysis, Justin Schmidt

Fire Protection Engineering: Culminating Experience Project Reports

This paper compares two design approaches for a 4-story atrium. The subject is the New Burke Museum building that is currently under construction in Seattle, WA. Under normal conditions, this building has four levels that are connected by different horizontal and vertical openings. The building design utilizes a series of vertical and horizontal acting fire doors to create separation and eliminate the atrium condition. The building’s alternate design is compared to a traditional atrium design meeting the requirements of section 404 of the IBC with an active smoke control system designed using NFPA 92B. In order to complete the analysis …


Analysis Of Costco, San Francisco, Ian Levine Jun 2016

Analysis Of Costco, San Francisco, Ian Levine

Fire Protection Engineering: Culminating Experience Project Reports

This report provides an in-depth analysis of the fire safety systems and design considerations of the Costco store located at 450 10th Street in San Francisco, California, satisfying the requirements for completion of the FPE 596 – Culminating Experience in Fire Protection Engineering academic series. The building is introduced, followed by an analysis of the building structure, alarm and detection, egress, and sprinkler systems are designed based on prescriptive code. These systems are then analyzed from a performance based perspective to gain understanding of how the systems will respond to a challenging design fire. Their response is used to determine …


Monticello Office Building- Fire And Life Safety Analysis, Mark James Masciarelli Jun 2016

Monticello Office Building- Fire And Life Safety Analysis, Mark James Masciarelli

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety analysis was performed on the existing Monticello Office Building located in Delaware, USA. The Monticello Office Building is a mixed use building that contains office space to support a population of 700 people, dining facilities to accommodate approximately 400 people, and a conference area for up to 125 people. The building is composed of two major components; a five (5) story office wing and a one (1) and two (2) story amenities wing that mainly houses the food service, dining, kitchen, retail and conference areas. A prescriptive analysis of this building was performed to determine …


Centennial Station- Evaluation, Brandon Huffman Jun 2016

Centennial Station- Evaluation, Brandon Huffman

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this analysis is for completion of FPE 596 Culminating Experience in Fire Protection Engineering course in the Fire Protection Engineering Program at California Polytechnic State University. This analysis has been compiled using previous design courses evaluating the egress analysis, suppression design, alarm and detection design, smoke control system design, and structural fire protection. The context of the courses studied both prescriptive and performance based design approaches.

The building chosen for the analysis is Centennial Station located approximately 15 miles south of Denver, Colorado at 12154 East Easter Avenue, Englewood, CO 80112. The facility was designed specifically for …


Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman Jun 2016

Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection & Life Safety Analysis was conducted in order to fulfill the requirements for the degree of Master of Science in Fire Protection Engineering. The Fire Protection & Life Safety Analysis consisted of a prescriptive and performance-based analysis of the Eric Rood Administration Center (Rood Center).

The prescriptive based analysis was conducted to determine if the Rood Center adhered to the applicable codes and standards. It utilized the 2013 California Building and Fire Codes and the 2012 Life Safety Code (NFPA 101). Other NFPA codes that were referenced included the 2013 edition of NFPA 13, Standard for the …


Mayo Clinic Specialties Building- Fire And Life Safety Report, Taylor Bateman Jun 2016

Mayo Clinic Specialties Building- Fire And Life Safety Report, Taylor Bateman

Fire Protection Engineering: Culminating Experience Project Reports

The MCS Building is a medical clinic facility located in Phoenix, Arizona. It is a four-story building with roughly 40,000 square feet of occupied floor area per story. The MCS Building is connected to an adjoining hospital on all four occupied stories, and is not considered a separate building from the hospital in accordance with the 2012 International Building Code (IBC). However, for the academic purposes of this report, only the fire and life safety features of the MCS Building are discussed, as if it is a separate building. It consists primarily of medical offices and outpatient clinics, and is …


University Of Southern California Heritage Hall- Fire Protection And Life Safety Analysis, Ivan Popilyanu Jun 2016

University Of Southern California Heritage Hall- Fire Protection And Life Safety Analysis, Ivan Popilyanu

Fire Protection Engineering: Culminating Experience Project Reports

This fire protection and life safety analysis is submitted in partial fulfillment of the requirements for the Master of Science Degree from California Polytechnic State University, San Luis Obispo. The study was performed on the University of Southern California’s Heritage Hall, which includes both a code-determined prescriptive examination and a performance-based analysis. The purpose of this review is to evaluate the Heritage Hall address based on compliance with all applicable codes and standards, as well as the determined occupant tenability criteria. The prescriptive examination of Heritage Hall consisted of the evaluation of all structural fire protection, egress analysis and design, …


Micro-Mechanics: Fire And Life Safety Evaluation, Michael Beam Mar 2016

Micro-Mechanics: Fire And Life Safety Evaluation, Michael Beam

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to perform a fire and life safety evaluation of an existing building, Micro-Mechanics. The current codes and standards are used to evaluate the following prescriptive fire protection systems including: Occupancy and Hazard Classification, Structural Fire Protection, Egress Analysis, Fire Detection, Alarm and Communication Systems, and Fire Suppression Systems. An evaluation of possible special hazards is discussed to determine if any extra precautions need to be taken to prevent uncontrollable fire or explosions. A performance based analysis is used to evaluate the effectiveness of the prescriptive building systems. Using a combination of computer models including …